Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
J Liver Cancer ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38714358

RESUMEN

Background/Aims: The enhancing "capsule" (EC) in hepatocellular carcinoma (HCC) diagnosis has received varying degrees of recognition across major guidelines. This study aimed to assess the diagnostic utility of EC in HCC detection. Methods: We retrospectively analyzed patients who underwent pre-surgical computed tomography (CT) and hepatobiliary agent-enhanced magnetic resonance imaging (HBA-MRI) between January 2016 and December 2019. A single hepatic tumor was confirmed based on the pathology of each patient. Three radiologists independently reviewed the images according to the Liver Imaging Reporting and Data System (LIRADS) v2018 criteria and reached a consensus. Interobserver agreement for EC before reaching a consensus was quantified using Fleiss κ statistics. The impact of EC on the LI-RADS classification was assessed by comparing the positive predictive values for HCC detection in the presence and absence of EC. Results: In total, 237 patients (median age, 60 years; 184 men) with 237 observations were included. The interobserver agreement for EC detection was notably low for CT (κ=0.169) and HBA-MRI (κ=0.138). The presence of EC did not significantly alter the positive predictive value for HCC detection in LI-RADS category 5 observations on CT (94.1% [80/85] vs. 94.6% [88/93], P=0.886) or HBA-MRI (95.7% [88/92] vs. 90.6% [77/85], P=0.178). Conclusions: The diagnostic value of EC in HCC diagnosis remains questionable, given its poor interobserver agreement and negligible impact on positive predictive values for HCC detection. This study challenges the emphasis on EC in certain diagnostic guidelines and suggests the need to re-evaluate its role in HCC imaging.

2.
Pancreas ; 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38530942

RESUMEN

BACKGROUND: To predict poor overall survival (OS) in pancreatic adenocarcinoma (PAC) who underwent FOLFIRINOX (5-fluorouracil/leucovorin/irinotecan/oxaliplatin) using clinical and computed tomography (CT) findings. METHODS: A total of 189 patients with PAC who received FOLFIRINOX were retrospectively included. Two reviewers assessed CT findings and resectability based on National Comprehensive Cancer Network guidelines. They determined tumor size changes according to Response Evaluation Criteria in Solid Tumors (RECIST 1.1). Delta measurements were performed. Clinical results, such as whether to perform surgery, were also investigated. A Cox proportional hazard model was used to identify significant predictors for OS. A CT-based nomogram was constructed to predict OS. RESULTS: Seventy-four patients (39.2%) underwent surgery. For OS, rim enhancement of PAC on baseline CT (hazard ratio [HR], 1.75; 95% confidence interval [CI], 1.10-2.77; P = 0.018), high delta tumor on baseline CT (HR, 2.46; 95% CI, 1.55-3.91; P < 0.001), progressive disease at follow-up CT (HR, 8.89; 95% CI, 2.94-26.87; P < 0.001), and without surgery (HR, 2.81; 95% CI, 1.49-5.30; P = 0.001) were important features related to poor prognosis. The nomogram showed good predictive ability for the survival. CONCLUSION: Both clinical and CT findings were useful for predicting OS after FOLFIRINOX in PAC.

3.
Curr Med Imaging ; 20: e250523217310, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37231764

RESUMEN

BACKGROUND: Whether deep learning-based CT reconstruction could improve lesion conspicuity on abdominal CT when the radiation dose is reduced is controversial. OBJECTIVES: To determine whether DLIR can provide better image quality and reduce radiation dose in contrast-enhanced abdominal CT compared with the second generation of adaptive statistical iterative reconstruction (ASiR-V). AIMS: This study aims to determine whether deep-learning image reconstruction (DLIR) can improve image quality. METHOD: In this retrospective study, a total of 102 patients were included, who underwent abdominal CT using a DLIR-equipped 256-row scanner and routine CT of the same protocol on the same vendor's 64-row scanner within four months. The CT data from the 256-row scanner were reconstructed into ASiR-V with three blending levels (AV30, AV60, and AV100), and DLIR images with three strength levels (DLIR-L, DLIR-M, and DLIR-H). The routine CT data were reconstructed into AV30, AV60, and AV100. The contrast-to-noise ratio (CNR) of the liver, overall image quality, subjective noise, lesion conspicuity, and plasticity in the portal venous phase (PVP) of ASiR-V from both scanners and DLIR were compared. RESULTS: The mean effective radiation dose of PVP of the 256-row scanner was significantly lower than that of the routine CT (6.3±2.0 mSv vs. 2.4±0.6 mSv; p< 0.001). The mean CNR, image quality, subjective noise, and lesion conspicuity of ASiR-V images of the 256-row scanner were significantly lower than those of ASiR-V images at the same blending factor of routine CT, but significantly improved with DLIR algorithms. DLIR-H showed higher CNR, better image quality, and subjective noise than AV30 from routine CT, whereas plasticity was significantly better for AV30. CONCLUSION: DLIR can be used for improving image quality and reducing radiation dose in abdominal CT, compared with ASIR-V.


Asunto(s)
Aprendizaje Profundo , Humanos , Mejoramiento de la Calidad , Estudios Retrospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador
4.
Cancer Imaging ; 23(1): 126, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38111054

RESUMEN

OBJECTIVES: To assess the resectability of pancreatic ductal adenocarcinoma (PDAC), the evaluation of tumor vascular contact holds paramount significance. This study aimed to compare the image quality and diagnostic performance of high-resolution (HR) pancreas computed tomography (CT) using an 80 kVp tube voltage and a thin slice (1 mm) for assessing PDAC resectability, in comparison with the standard protocol CT using 120 kVp. METHODS: This research constitutes a secondary analysis originating from a multicenter prospective study. All participants underwent both the standard protocol pancreas CT using 120 kVp with 3 mm slice thickness (ST) and HR-CT utilizing an 80 kVp tube voltage and 1 mm ST. The contrast-to-noise ratio (CNR) between parenchyma and tumor, along with the degree of enhancement of the abdominal aorta and main portal vein (MPV), were measured and subsequently compared. Additionally, the likelihood of margin-negative resection (R0) was evaluated using a five-point scale. The diagnostic performance of both CT protocols in predicting R0 resection was assessed through the area under the receiver operating characteristic curve (AUC). RESULTS: A total of 69 patients (37 males and 32 females; median age, 66.5 years) were included in the study. The median CNR of PDAC was 10.4 in HR-CT, which was significantly higher than the 7.1 in the standard CT (P=0.006). Furthermore, HR-CT demonstrated notably higher median attenuation values for both the abdominal aorta (579.5 HU vs. 327.2 HU; P=0.002) and the MPV (263.0 HU vs. 175.6 HU; P=0.004) in comparison with standard CT. Following surgery, R0 resection was achieved in 51 patients. The pooled AUC for HR-CT in predicting R0 resection was 0.727, slightly exceeding the 0.699 of standard CT, albeit lacking a significant statistical distinction (P=0.128). CONCLUSION: While HR pancreas CT using 80 kVp offered a notably greater degree of contrast enhancement in vessels and a higher CNR for PDAC compared to standard CT, its diagnostic performance in predicting R0 resection remained statistically comparable.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Anciano , Femenino , Humanos , Masculino , Carcinoma Ductal Pancreático/diagnóstico por imagen , Carcinoma Ductal Pancreático/cirugía , Medios de Contraste , Páncreas/diagnóstico por imagen , Páncreas/cirugía , Páncreas/patología , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Neoplasias Pancreáticas/patología , Estudios Prospectivos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Estudios Multicéntricos como Asunto
5.
Cancer Imaging ; 23(1): 73, 2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37528480

RESUMEN

BACKGROUND: Loss of muscle mass is the most common complication of end-stage liver disease and negatively affects outcomes for liver transplantation (LT) recipients. We aimed to determine the prognostic value of a fully automated three-dimensional (3D) muscle volume estimation using deep learning algorithms on abdominal CT in patients who underwent liver transplantation (LT). METHODS: This retrospective study included 107 patients who underwent LT from 2014 to 2015. Serial CT scans, including pre-LT and 1- and 2-year follow-ups were performed. From the CT scans, deep learning-based automated body composition segmentation software was used to calculate muscle volumes in 3D. Sarcopenia was calculated by dividing average skeletal muscle area by height squared. Newly developed-(ND) sarcopenia was defined as the onset of sarcopenia 1 or 2 years after LT in patients without a history of sarcopenia before LT. Patients' clinical characteristics, including post-transplant diabetes mellitus (PTDM) and Model for end-stage liver disease score, were compared according to the presence or absence of sarcopenia after LT. A subgroup analysis was performed in the post-LT sarcopenic group. The Kaplan-Meier method was used for overall survival (OS). RESULTS: Patients with ND-sarcopenia had poorer OS than those who did not (P = 0.04, hazard ratio [HR], 3.34; 95% confidence interval [CI] 1.05 - 10.7). In the subgroup analysis for post-LT sarcopenia (n = 94), 34 patients (36.2%) had ND-sarcopenia. Patients with ND-sarcopenia had significantly worse OS (P = 0.002, HR 7.12; 95% CI 2.00 - 25.32) and higher PTDM occurrence rates (P = 0.02, HR 4.93; 95% CI 1.18 - 20.54) than those with sarcopenia prior to LT. CONCLUSION: ND-sarcopenia determined by muscle volume on abdominal CT can predict poor survival outcomes and the occurrence of PTDM for LT recipients.


Asunto(s)
Diabetes Mellitus , Enfermedad Hepática en Estado Terminal , Trasplante de Hígado , Sarcopenia , Humanos , Trasplante de Hígado/efectos adversos , Sarcopenia/complicaciones , Sarcopenia/diagnóstico por imagen , Sarcopenia/epidemiología , Enfermedad Hepática en Estado Terminal/complicaciones , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Diabetes Mellitus/epidemiología , Músculo Esquelético/diagnóstico por imagen , Tomografía Computarizada por Rayos X/efectos adversos
6.
Int J Hyperthermia ; 40(1): 2235102, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37455021

RESUMEN

BACKGROUND: The novel separable clustered electrode system with two adjustable active tips (ICAEs) and a fine multipurpose needle (MPN) for in situ temperature monitoring and adjuvant agent injection was developed and validated in an animal study. The purpose of this study was to evaluate the technical efficacy and complication of the novel electrode system for patients who have small HCC. METHODS: In this prospective, single-center clinical trial, ten participants with 14 small (≤ 2 cm, BCLC 0-A) HCCs referred for RFA were enrolled. A novel electrode system consisting of two ICAEs and one MPN with a thermometer and side holes was used for RFA. The RF energy was delivered using a multichannel RF system combining bipolar and switching monopolar modes. Technical success, efficacy, and complications were evaluated on immediate and one-month follow-up CT. RESULTS: Technical success was achieved in 92.9% (13/14) of tumors. One participant withdrew consent after RFA, and technical efficacy was achieved in 91.7% (11/12) of tumors. None showed thermal injury to nontarget organs. All patients were discharged the day after RFA without major complications. The active electrode lengths were adjusted in 60% (6/10) of patients during the procedure to tailor the ablation zone (83.3%, n = 5) or treat two tumors with different sizes (16.7%, n = 1). MPN was capable of continuous temperature monitoring during all ablations (100%, 14/14). CONCLUSIONS: RFA using a novel electrode system showed acceptable technical efficacy and safety in patients with small HCCs. Further comparative studies are needed for the investigation of the system's potential benefits compared to conventional electrodes.


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Ablación por Radiofrecuencia , Animales , Humanos , Carcinoma Hepatocelular/cirugía , Carcinoma Hepatocelular/patología , Ablación por Catéter/métodos , Electrodos , Estudios de Factibilidad , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/patología , Estudios Prospectivos , Resultado del Tratamiento
7.
J Magn Reson Imaging ; 58(5): 1375-1383, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-36825827

RESUMEN

BACKGROUND: Little is known about the performance of abbreviated MRI (AMRI) for secondary surveillance of recurrent hepatocellular carcinoma (HCC) after curative treatment. PURPOSE: To evaluate the detection performance of AMRI for secondary surveillance of HCC after curative treatment. STUDY TYPE: Retrospective. POPULATION: A total of 243 patients (183 men and 60 women; median age, 65 years) who underwent secondary surveillance for HCC using gadoxetic acid-enhanced MRI after more than 2 year of disease-free period following curative treatment, including surgical resection or radiofrequency ablation (RFA). FIELD STRENGTH/SEQUENCE: A 3.0 T/noncontrast AMRI (NC-AMRI) (T2-weighted fast spin-echo, T1-weighted gradient echo, and diffusion-weighted images), hepatobiliary phase AMRI (HBP-AMRI) (T2-weighted fast spin-echo, diffusion-weighted, and HBP images), and full-sequence MRI ASSESSMENT: Four board-certified radiologists independently reviewed NC-AMRI, HBP-AMRI, and full-sequence MRI sets of each patient for detecting recurrent HCC. STATISTICAL TESTS: Per-lesion sensitivity, per-patient sensitivity and specificity for HCC detection at each set were compared using generalized estimating equation. RESULTS: A total of 42 recurred HCCs were confirmed in the 39 patients. The per-lesion and per-patient sensitivities did not show significant differences among the three image sets for either reviewer (P ≥ 0.358): per-lesion sensitivity: 59.5%-83.3%, 59.5%-85.7%, and 59.5%-83.3%, and per-patient sensitivity: 53.9%-83.3%, 56.4%-85.7%, and 53.9%-83.3% for NC-AMRI, HBP-AMRI, and full-sequence MRI, respectively. Per-lesion pooled sensitivities of NC-AMRI, HBP-AMRI, and full-sequence MRI were 72.6%, 73.2%, and 73.2%, with difference of -0.6% (95% confidence interval: -6.7, 5.5) between NC-AMRI and full-sequence MRI and 0.0% (-6.1, 6.1) between HBP-AMRI and full-sequence MRI. Per-patient specificity was not significantly different among the three image sets for both reviewers (95.6%-97.1%, 95.6%-97.1%, and 97.6%-98.5% for NC-AMRI and HBP-AMRI, respectively; P ≥ 0.117). DATA CONCLUSION: NC-AMRI and HBP-AMRI showed no significant difference in detection performance to that of full-sequence gadoxetic acid-enhanced MRI during secondary surveillance for HCC after more than 2-year disease free interval following curative treatment. Based on its good detection performance, short scan time, and lack of contrast agent-associated risks, NC-AMRI is a promising option for the secondary surveillance of HCC. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Masculino , Humanos , Femenino , Anciano , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Estudios Retrospectivos , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Medios de Contraste , Sensibilidad y Especificidad
8.
Korean J Radiol ; 24(2): 86-94, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36725351

RESUMEN

OBJECTIVE: To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo. MATERIALS AND METHODS: Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60\xe2\x84\x83 in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination. RESULTS: In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm3 vs. 12.5 ± 2.14 cm3, p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group (p < 0.001 for all). CONCLUSION: RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.


Asunto(s)
Ablación por Catéter , Octopodiformes , Porcinos , Animales , Ablación por Catéter/métodos , Diseño de Equipo , Hígado/cirugía , Hígado/patología , Electrodos
9.
Eur Radiol ; 33(1): 545-554, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35907024

RESUMEN

OBJECTIVES: Percutaneous radiofrequency ablation (RFA) is one of the curative treatments for hepatocellular carcinoma (HCC), but local tumor progression (LTP) has been a main limitation of RFA. This study aims to evaluate the LTP of percutaneous no-touch RFA (NtRFA) for HCC ≤ 5 cm and compare with conventional RFA (intratumoral puncture) through a systematic review and meta-analysis. METHODS: MEDLINE, EMBASE, and Cochrane Library were searched for studies on percutaneous NtRFA for HCC ≤ 5 cm. The pooled proportions of the overall and cumulative incidence rates at 1, 2, and 3 years for LTP after NtRFA were assessed using a random-effects model. For studies comparing NtRFA with conventional RFA, relative risks (RR) and hazard ratios (HR) were meta-analytically pooled with LTP as the outcome. RESULTS: Twelve studies with 900 patients were included. The pooled overall rate of LTP after NtRFA was 6% (95% CI, 4-8%). The pooled 1-, 2-, and 3-year cumulative incidence rates of LTP were 3% (95% CI, 2-5%), 5% (95% CI, 3- 9%), and 8% (95% CI, 6-11%), respectively. Compared to conventional RFA, the pooled RR and HR of LTP were 0.26 (95% CI, 0.16-0.41) and 0.28 (95% CI, 0.11-0.70), respectively (both p < 0.01). Subgroup analysis including only randomized controlled studies also showed better local tumor control of NtRFA with HR of 0.13 (95% CI, 0.14-0.42). CONCLUSIONS: Percutaneous NtRFA is an effective treatment for HCC ≤ 5 cm with an overall LTP rate of 6% and provides lower LTP compared with conventional RFA. KEY POINTS: • The pooled 1-, 2-, and 3-year cumulative incidence rates of local tumor progression after no-touch radiofrequency ablation for HCC ≤ 5 cm were 3% (95% CI, 2-5%), 5% (95% CI, 3-9%), and 8% (95% CI, 6-11%). • No-touch radiofrequency ablation had significantly lower rates of local tumor progression compared to conventional radiofrequency ablation (hazard ratio, 0.28; 95% CI, 0.11-0.70; relative risk, 0.26; 95% CI, 0.16-0.41; p < 0.01, respectively).


Asunto(s)
Carcinoma Hepatocelular , Ablación por Catéter , Neoplasias Hepáticas , Ablación por Radiofrecuencia , Humanos , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/patología , Ablación por Catéter/efectos adversos , Resultado del Tratamiento , Recurrencia Local de Neoplasia/cirugía , Estudios Retrospectivos
10.
Liver Transpl ; 29(3): 307-317, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36177604

RESUMEN

This study aimed to classify the anatomical types of biliary strictures, including intrahepatic biliary stricture (IHBS), after living donor liver transplantations (LDLTs) using right liver grafts and evaluate their prognosis. Among 692 adult patients who underwent right liver LDLT, 198 recipients with biliary strictures (28.6%) were retrospectively reviewed. Based on data obtained during the first cholangiography, the patients' biliary strictures were classified into the following three types according to the levels and number of branches involved: Types 1 (anastomosis), 2 (second-order branch [a, one; b, two or more; c, extended to the third-order branch]), and 3 (whole graft [a, multifocal strictures; b, diffuse necrosis]). IHBS was defined as a nonanastomotic stricture. Among the 198 recipients with biliary strictures, the IHBS incidence rates were 38.4% ( n = 76). The most common type of IHBS was 2c ( n = 43, 56.6%), whereas Type 3 ( n = 10, 13.2%) was uncommon. The intervention frequency per year significantly differed among the types (Type 1, 2.3; Type 2a, 2.3; Type 2b, 2.8; Type 2c, 4.3; and Type 3, 7.2; p < 0.001). The intervention-free period for more than 1 year, which was as follows, also differed among the types: Type 1, 84.4%; Type 2a, 87.5%; Type 2b, 86.7%; Type 2c, 72.1%; and Type 3, 50.0% ( p = 0.048). The graft survival rates of Type 3 (80.0%) were significantly lower than those of the other types ( p = 0.001). IHBSs are relatively common in right liver LDLTs. Although Type 3 IHBSs are rare, they require more intensive care and are associated with poorer graft survival rates than anastomosis strictures and Type 2 IHBS.


Asunto(s)
Colestasis , Trasplante de Hígado , Adulto , Humanos , Trasplante de Hígado/efectos adversos , Donadores Vivos , Constricción Patológica/etiología , Estudios Retrospectivos , Colestasis/etiología , Anastomosis Quirúrgica/efectos adversos , Hígado/cirugía , Complicaciones Posoperatorias/etiología
11.
Eur J Cancer ; 174: 165-175, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36029713

RESUMEN

BACKGROUND: Neoadjuvant treatment with either chemotherapy or immunotherapy is gaining momentum in colon cancers (CC). To reduce over-treatment, increasing staging accuracy using computed tomography (CT) is of high importance. PURPOSE: To assess and compare CT imaging features of CC between mismatch repair-proficient (pMMR) and MMR-deficient (dMMR) tumours and identify CT features that can distinguish high-risk (pT3-4, N+) CC according to MMR status. METHODS: Primary staging CTs of 266 patients who underwent primary surgical resection of a colon tumour were retrospectively and independently evaluated by two radiologists. Logistic regression analysis was performed to identify significant associations between imaging features and positive lymph node status. Receiver operating characteristic (ROC) curves of significantly associated features were assessed and validated in an external cohort of 104 patients. RESULTS: Among pT3 tumours only, dMMR CC were significantly larger than pMMR CC in both length and thickness (length 59.39 ± 26.28 mm versus 48.70 ± 23.72, respectively, p = 0.031; thickness 20.54 mm ± 11.17 versus 16.34 ± 8.73, respectively, p = 0.027). For pMMR tumours, nodal internal heterogeneity on CT was significantly associated with a positive lymph node status (odds ratio (OR) = 2.66, p = 0.027), while for dMMR tumours, the largest short diameter of the nodes was associated with lymph node status (OR = 2.01, p = 0.049). The best cut-off value of the largest short diameter of involved nodes was 10.4 mm for dMMR and 7.95 mm for pMMR. In the external validation cohort, AUCs for predicting involved nodes based on the largest short diameter was 0.764 for dMMR tumours using 10 mm size cut-off and 0.624 for pMMR tumours using 7 mm cut-off. CONCLUSION: These data show that CT imaging features of primary CC differ between dMMR and pMMR tumours, suggesting that the assessment of CT-based CC staging should take MMR status into consideration, especially for lymph node status, and thus may help in selecting patients for neoadjuvant treatment.


Asunto(s)
Neoplasias del Colon , Neoplasias Colorrectales , Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/genética , Neoplasias del Colon/patología , Neoplasias Colorrectales/patología , Reparación de la Incompatibilidad de ADN/genética , Humanos , Estadificación de Neoplasias , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
12.
Abdom Radiol (NY) ; 47(8): 2739-2746, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35661244

RESUMEN

PURPOSE: To assess the role of radiomics in detection of high-risk (pT3-4) colon cancer and develop a combined model that combines both radiomics and CT staging of colon cancer. METHODS: We included 292 colon cancer patients who underwent pre-operative CT and primary surgical resection within 2 months. Three-dimensional segmentations and CT staging of primary colon tumors were done. From each 3D segmentation of colon tumor, radiomic features were automatically extracted. Logistic regression analysis was performed to identify associations between radiomic features and high-risk (pT3-4) colon tumors. A combined model that integrated both radiomics and CT staging was developed and their diagnostic performance was compared with that of conventional CT staging. Tenfold cross-validation was used to validate the performance of the model and CT staging. RESULTS: The model that combined radiomic features and CT staging demonstrated a significantly better performance in detection of high-risk colon tumors in training set (AUC = 0.799, 95% CI: 0.720-0.839 for combined model and AUC = 0.697, 95% CI = 0.538-0.756 for CT staging only, p < 0.001 for difference). Cross-validation results also demonstrated significantly better detection performance of combined model (AUC = 0.727, 95% Confidence Interval (CI): 0.621-0.777 for combined model and AUC = 0.628, 95% CI = 0.558-0.689 for CT staging only, Boot CI = 0.099). CONCLUSION: CT radiomic features of primary colon cancer, combined with CT staging, can improve the detection of high-risk colon cancer patients.


Asunto(s)
Neoplasias del Colon , Tomografía Computarizada por Rayos X , Neoplasias del Colon/diagnóstico por imagen , Humanos , Radiólogos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
13.
AJR Am J Roentgenol ; 219(3): 421-432, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35319906

RESUMEN

BACKGROUND. In LI-RADS version 2018, observations showing at least one of five targetoid appearances in different sequences or postcontrast phases are categorized LR-M, indicating likely non-hepatocellular carcinoma (HCC) malignancy. OBJECTIVE. The purpose of this study was to evaluate interobserver agreement for LI-RADS targetoid appearances among a large number of radiologists of varying experience and the diagnostic performance of targetoid appearances for differentiating HCC from non-HCC malignancy. METHODS. This retrospective study included 100 patients (76 men, 24 women; mean age, 58 ± 9 [SD] years) at high risk of HCC who underwent gadoxetic acid-enhanced MRI within 30 days before hepatic tumor resection (25 randomly included patients with non-HCC malignancy [13, intrahepatic cholangiocarcinoma; 12, combined HCC-cholangiocarcinoma]; 75 matched patients with HCC). Eight radiologists (four more experienced [8-15 years]; four less experienced [1-5 years]) from seven institutions independently assessed observations for the five targetoid appearances and LI-RADS categorization. Interobserver agreement and diagnostic performance for non-HCC malignancy were evaluated. RESULTS. Interobserver agreement was poor for peripheral washout (κ = 0.20); moderate for targetoid transitional phase or hepatobiliary phase appearance (κ = 0.33), delayed central enhancement (κ = 0.37), and targetoid restriction (κ = 0.43); and substantial for rim arterial phase hyperenhancement (κ = 0.61). Agreement was fair for at least one targetoid appearance (κ = 0.36) and moderate for at least two, three, or four targetoid appearances (κ = 0.43-0.51). Agreement for individual targetoid appearances was not significantly different between more experienced and less experienced readers other than for targetoid restriction (κ = 0.63 vs 0.43; p = .001). Agreement for at least one targetoid appearance was fair among more experienced (κ = 0.29) and less experienced (κ = 0.37) reviewers. Agreement for at least two, three, or four targetoid appearances was moderate to substantial among more experienced reviewers (κ = 0.45-0.63) and moderate among less experienced reviewers (κ = 0.42-0.56). Existing LR-M criteria of at least one targetoid appearance had median accuracy for non-HCC malignancy of 62%, sensitivity of 84%, and specificity of 54%. For all reviewers, accuracy was highest when at least three (median accuracy, 79%; sensitivity, 68%; specificity, 82%) or four (median accuracy, 80%; sensitivity, 54%; specificity, 88%) targetoid appearances were required. CONCLUSION. Targetoid appearances and LR-M categorization exhibited considerable interobserver variation among both more and less experienced reviewers. CLINICAL IMPACT. Requiring multiple targetoid appearances for LR-M categorization improved interobserver agreement and diagnostic accuracy for non-HCC malignancy.


Asunto(s)
Neoplasias de los Conductos Biliares , Carcinoma Hepatocelular , Colangiocarcinoma , Neoplasias Hepáticas , Anciano , Conductos Biliares Intrahepáticos/patología , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Colangiocarcinoma/diagnóstico por imagen , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Retrospectivos , Sensibilidad y Especificidad
14.
Radiology ; 302(1): 107-115, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34581625

RESUMEN

Background Diagnostic performance of the Liver Imaging Reporting and Data System tumor in vein (LR-TIV) category at CT and/or MRI has not yet been evaluated, to the knowledge of the authors. Purpose To assess the diagnostic performance of the LR-TIV category in detecting macroscopic tumors in veins (TIVs) at CT and hepatobiliary contrast agent-enhanced (HBA) MRI, with pathologic results used as the reference standard. Materials and Methods Between January 2010 and December 2019, consecutive patients with or without macroscopic TIV who underwent both CT and HBA MRI before hepatic resection or liver transplant were retrospectively included. Three radiologists independently assessed the LR-TIV features of enhancing soft tissue in vein and features suggestive of TIV (FSTIV) and reached a consensus. Macroscopic TIV at pathologic examination was the reference standard. Sensitivities and specificities of the LR-TIV category without and with FSTIV were calculated, and the added value of FSTIV was evaluated by using the McNemar test. Results In the 1322 patients with (n = 101) or without (n = 1221) macroscopic TIV (median age, 64 years [interquartile range, 58-70 years]; 1053 men), without consideration of FSTIV, the sensitivity and specificity of enhancing soft tissue in vein for detecting macroscopic TIV at pathologic examination were 64.4% (65 of 101) and 99.8% (1218 of 1221) with CT and 62.4% (63 of 101) and 99.8% (1218 of 1221) with HBA MRI, respectively. With consideration of FSTIV, the sensitivity and specificity of the LR-TIV category became 67.3% (68 of 101 patients) and 99.7% (1217 of 1221 patients) at both CT and HBA MRI. No difference was found between measurements without and with FSTIV (sensitivity, 62% vs 67% for CT [P = .45] and 64% vs 67% for HBA MRI [P = .18]; specificity, 99% for both CT and HBA MRI [P > .99 for both]). Conclusion The Liver Imaging Reporting and Data System tumor in vein category showed moderate sensitivity and high specificity in the detection of macroscopic tumors in veins at both CT and hepatobiliary contrast agent-enhanced MRI, with pathologic examination used as the reference standard. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Morrell in this issue.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sistemas de Información Radiológica , Tomografía Computarizada por Rayos X/métodos , Neoplasias Vasculares/diagnóstico por imagen , Anciano , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Hígado/irrigación sanguínea , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
15.
Eur Radiol ; 32(1): 46-55, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34132875

RESUMEN

OBJECTIVES: To determine the appropriate use of ancillary features (AFs) in upgrading LI-RADS category 3 (LR-3) to category 4 (LR-4) for hepatic nodules on gadoxetic acid-enhanced MRI. METHODS: We retrospectively analyzed MRI features of solid hepatic nodules (≤ 30 mm) categorized as LR-3/4 on gadoxetic acid-enhanced MRI. In LI-RADS diagnostic table-based-LR-3 observations, logistic regression analyses were performed to identify AFs suggestive of hepatocellular carcinomas (HCCs) rather than non-malignant nodules. Using McNemar's test, the sensitivities and specificities of the final-LR-4 category for HCC diagnosis were compared according to the principles of AF application in category adjustment. RESULTS: A total of 336 hepatic nodules (191 HCCs; 145 non-malignant) in 252 patients were evaluated. Based on major HCC features, 248 nodules (123 HCCs) were assigned as table-based-LR-3 and 88 nodules (68 HCCs) as table-based-LR-4. In table-based-LR-3 observations, mild-moderate T2 hyperintensity was identified as an independent predictor of HCC as opposed to non-malignant nodules (odds ratio = 3.01, p = 0.002). For HCC diagnosis, different criteria of final-LR-4: only table-based-LR-4, allowing category upgrade using only T2 hyperintensity, or using any AFs favoring malignancy resulted in sensitivities of 35.6% (68/191), 53.9% (103/191), and 88.5% (169/191), and specificities of 86.2% (125/145), 75.9% (110/145), and 21.4% (31/145), respectively, which differed from each other (all p < 0.001). CONCLUSIONS: While the application of MRI AF in LI-RADS category adjustment increases the sensitivity of LR-4 category for HCC diagnosis, it is accompanied by a significant decrease in specificity. Mild-moderate T2 hyperintensity, a significant AF indicative of HCC, may be more appropriate for upgrading LR-3 to LR-4. KEY POINTS: • When upgrading from LR-3 to LR-4 using any MRI ancillary features favoring malignancy, LR-4 sensitivity increases but specificity decreased for HCC diagnosis. • By upgrading LR-3 to LR-4 based on MRI ancillary features found to suggest HCC rather than non-malignant nodules in multivariate analysis (i.e., mild-moderate T2 hyperintensity), LR-4 demonstrated a more balanced sensitivity and specificity for HCC diagnosis (53.9% and 75.9%, respectively).


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Gadolinio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Probabilidad , Estudios Retrospectivos , Sensibilidad y Especificidad
16.
Liver Transpl ; : 307-317, 2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-37160060

RESUMEN

ABSTRACT: This study aimed to classify the anatomical types of biliary strictures, including intrahepatic biliary stricture (IHBS), after living donor liver transplantations (LDLTs) using right liver grafts and evaluate their prognosis. Among 692 adult patients who underwent right liver LDLT, 198 recipients with biliary strictures (28.6%) were retrospectively reviewed. Based on data obtained during the first cholangiography, the patients' biliary strictures were classified into the following three types according to the levels and number of branches involved: Types 1 (anastomosis), 2 (second-order branch [a, one; b, two or more; c, extended to the third-order branch]), and 3 (whole graft [a, multifocal strictures; b, diffuse necrosis]). IHBS was defined as a nonanastomotic stricture. Among the 198 recipients with biliary strictures, the IHBS incidence rates were 38.4% ( n  = 76). The most common type of IHBS was 2c ( n  = 43, 56.6%), whereas Type 3 ( n  = 10, 13.2%) was uncommon. The intervention frequency per year significantly differed among the types (Type 1, 2.3; Type 2a, 2.3; Type 2b, 2.8; Type 2c, 4.3; and Type 3, 7.2; p < 0.001). The intervention-free period for more than 1 year, which was as follows, also differed among the types: Type 1, 84.4%; Type 2a, 87.5%; Type 2b, 86.7%; Type 2c, 72.1%; and Type 3, 50.0% ( p  = 0.048). The graft survival rates of Type 3 (80.0%) were significantly lower than those of the other types ( p  = 0.001). IHBSs are relatively common in right liver LDLTs. Although Type 3 IHBSs are rare, they require more intensive care and are associated with poorer graft survival rates than anastomosis strictures and Type 2 IHBS.

17.
Abdom Radiol (NY) ; 46(10): 4765-4778, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34085090

RESUMEN

PURPOSE: We aimed to evaluate the predictive factors of conversion surgery in pancreatic adenocarcinoma (PAC) after neoadjuvant or palliative FOLFIRINOX using baseline and follow-up CT. METHODS: We retrospectively included 189 patients who had undergone more than 4 cycles of FOLFIRINOX. We reviewed baseline CT (B-CT), 1st follow-up CT (1st-CT), and the preoperative or last follow-up CT (L-CT) and determined tumor size changes according to the Response Evaluation Criteria in Solid Tumors (RECIST 1.1). Extra-pancreatic perineural invasion (EPNI) and resectability using NCCN 2019 guideline were evaluated. Subgroup analysis by baseline resectability was performed. RESULTS: B-CT included resectable (n = 25, 23.2%), borderline (n = 55, 29.1%), locally advanced (n = 44, 23.3%), and metastatic (n = 65, 34.4%) PAC. Seventy-four patients had undergone surgery (39.2%) with an 83.8% (62/74) R0 resection. For operability, resectable status at L-CT (hazard ratio (HR) 65.5; 95% confidence interval (CI) 5.0-865; P = 0.002), RECIST (partial response) at 1st-CT (HR 3.6; 95% CI 1.1-11.7; P = 0.032), and baseline borderline resectability (HR 8.6; 95% CI 1.6-46.4; P = 0.013) were important predictors. Based on a size reduction cut-off of 22.2%, the area under the receiver operating characteristic (ROC) curve (Az) was 0.761 (sensitivity = 70.3%, specificity = 74.8%). In subgroup analysis, RECIST (partial response) at 1st-CT was a significant predictor of locally advanced PAC (HR 32; 95% CI 4.5-227, P 0.001), and the optimal cut-off was 22.2% (Az = 0.914; sensitivity = 100%, specificity = 75%). Baseline tumor size ([Formula: see text] 4 cm) (HR 5.6, 95% CI 1.3-24.3, P = 0.022) and unresectable status at 1st-CT (HR 4.8, 95% CI 1.1-20.6, P = 0.035) were significantly associated with margin-positive resection. CONCLUSION: Both baseline and follow-up CT findings are useful to predict conversion surgery for PAC after FOLFIRINOX.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/tratamiento farmacológico , Adenocarcinoma/cirugía , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Fluorouracilo , Estudios de Seguimiento , Humanos , Irinotecán , Leucovorina , Terapia Neoadyuvante , Estadificación de Neoplasias , Oxaliplatino , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/cirugía , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
18.
Abdom Radiol (NY) ; 46(9): 4096-4105, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33904991

RESUMEN

PURPOSE: To evaluate the diagnostic accuracy of imaging features to predict lymph node status of colon cancer using CT. METHODS: This was a retrospective study from 2 tertiary hospitals in South Korea and Netherlands. 317 Colon cancer patients who underwent primary surgical treatment were included. Number of lymph nodes according to the anatomical location, size, cluster, degree of attenuation, shape, presence of internal heterogeneity and ill-defined margin of the lymph node were assessed and compared according to histological lymph node status. RESULTS: The largest short diameter of lymph node and presence of internal heterogeneity of lymph node showed significant association with malignant lymph node status (P < 0.001 and P = 0.041, respectively). The ROC curve analysis revealed AUC of 0.703 for the largest short diameter of lymph node (P < 0.001), and AUC of the presence of internal heterogeneity was 0.630 (P < 0.001). In addition, our study showed that a total number of lymph nodes, regardless of size, (P = 0.022) and number of lymph nodes in peritumoral area (P < 0.001) and along the mesenteric vessels (P < 0.001) on CT demonstrated significant association with malignant status of lymph nodes in colon cancer. CONCLUSIONS: There were significant associations between lymph node status and imaging features of lymph nodes on CT in colon cancer patients. The largest short diameter of lymph node and presence of internal heterogeneity can be used to predict the malignant status of lymph node in colon cancer patients. Also, the number of lymph nodes near the colonic tumor should be considered in assessment of colon cancer lymph node involvement on CT.


Asunto(s)
Neoplasias del Colon , Ganglios Linfáticos , Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/patología , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Metástasis Linfática/diagnóstico por imagen , Estadificación de Neoplasias , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
19.
Eur J Radiol ; 139: 109687, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33836335

RESUMEN

PURPOSE: This study aimed to investigate the correlation of attenuation between virtual noncontrast (VNC) and true noncontrast (TNC) CT images and compare the diagnostic performance for hepatic steatosis using MR spectroscopy (MRS) as the reference standard. METHODS: A total of 131 consecutive hepatic donor candidates who underwent dual-source dual-energy CT and MRS within one month from January 2018 to April 2019 were included. An MRS value > 5.8 % was regarded as substantial hepatic steatosis. The correlation of attenuation between TNC and VNC in the liver and spleen, and liver attenuation index (LAI), defined as hepatic minus splenic attenuation, was evaluated using Spearman's rank correlation. The diagnostic performance of the LAI for hepatic steatosis was compared using receiver operating characteristic analyses. RESULTS: Twenty-three candidates (17.6 %) had substantial hepatic steatosis. The median liver attenuation (66.7 [IQR, 63.5-70.9] vs. 63.5 [IQR, 60.3-66.9], p < .001) and LAI (12.9 [9.3-16.7] vs. 7.4 [3.9-11.9], p < .001) in the VNC were higher than those in the TNC. Hepatic attenuation (r = 0.93, p < .001), splenic attenuation (r = 0.55, p < .001), and LAI (r = 0.87, p < .001) were significantly correlated between TNC and VNC. Area under the curve of LAI in TNC and VNC were 0.88 (cutoff, LAI < 3.1) and 0.84 (cutoff, LAI < 10.1), respectively, indicating no statistically significant difference (p = 0.11). CONCLUSION: The LAI of VNC is significantly correlated with that of TNC and might be feasible for diagnosing substantial hepatic steatosis in living liver donor candidates using different cutoff values of LAI.


Asunto(s)
Hígado Graso , Trasplante de Hígado , Hígado Graso/diagnóstico por imagen , Humanos , Donadores Vivos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
20.
Korean J Radiol ; 22(7): 1077-1086, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33739636

RESUMEN

OBJECTIVE: To investigate the diagnostic performance of quantitative ultrasound (US) parameters for the assessment of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD) using magnetic resonance imaging proton density fat fraction (MRI-PDFF) as the reference standard. MATERIALS AND METHODS: In this single-center prospective study, 120 patients with clinically suspected NAFLD were enrolled between March 2019 and January 2020. The participants underwent US examination for radiofrequency (RF) data acquisition and chemical shift-encoded liver MRI for PDFF measurement. Using the RF data analysis, the attenuation coefficient (AC) based on tissue attenuation imaging (TAI) (AC-TAI) and scatter-distribution coefficient (SC) based on tissue scatter-distribution imaging (TSI) (SC-TSI) were measured. The correlations between the quantitative US parameters (AC and SC) and MRI-PDFF were evaluated using Pearson correlation coefficients. The diagnostic performance of AC-TAI and SC-TSI for detecting hepatic fat contents of ≥ 5% (MRI-PDFF ≥ 5%) and ≥ 10% (MRI-PDFF ≥ 10%) were assessed using receiver operating characteristic (ROC) analysis. The significant clinical or imaging factors associated with AC and SC were analyzed using linear regression analysis. RESULTS: The participants were classified based on MRI-PDFF: < 5% (n = 38), 5-10% (n = 23), and ≥ 10% (n = 59). AC-TAI and SC-TSI were significantly correlated with MRI-PDFF (r = 0.659 and 0.727, p < 0.001 for both). For detecting hepatic fat contents of ≥ 5% and ≥ 10%, the areas under the ROC curves of AC-TAI were 0.861 (95% confidence interval [CI]: 0.786-0.918) and 0.835 (95% CI: 0.757-0.897), and those of SC-TSI were 0.964 (95% CI: 0.913-0.989) and 0.935 (95% CI: 0.875-0.972), respectively. Multivariable linear regression analysis showed that MRI-PDFF was an independent determinant of AC-TAI and SC-TSI. CONCLUSION: AC-TAI and SC-TSI derived from quantitative US RF data analysis yielded a good correlation with MRI-PDFF and provided good performance for detecting hepatic steatosis and assessing its severity in NAFLD.


Asunto(s)
Enfermedad del Hígado Graso no Alcohólico , Análisis de Datos , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Estudios Prospectivos , Protones , Estándares de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...