Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Acta Radiol ; : 2841851241253936, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38778748

RESUMEN

BACKGROUND: Post-treatment evaluation of patients with rectal cancer (RC) using magnetic resonance imaging (MRI) burdens medical resources, necessitating an exploration of abbreviated protocols. PURPOSE: To evaluate the diagnostic performance of abbreviated MRI (A-MRI) for the post-treatment evaluation of RC patients. MATERIAL AND METHODS: This retrospective study included RC patients who underwent non-contrast rectal MRI and standard liver MRI, as well as abdominal contrast-enhanced computed tomography (CECT) for post-treatment evaluation. A-MRI comprised diffusion-weighted imaging (DWI) and T2-weighted imaging of the upper abdomen and the pelvic cavity. Three radiologists independently reviewed A-MRI, CECT, and standard liver MRI in the detection of viable disease. The diagnostic performances were compared using a reference standard considering all available information, including pathology, FDG-PET, endoscopic results, and clinical follow-up. RESULTS: We included 78 patients (50 men, 28 women; mean age=60.9 ± 10.2 years) and observed viable disease in 34 (43.6%). On a per-patient-basis analysis, A-MRI showed significantly higher sensitivity (95% vs. 81%, P = 0.04) and higher accuracy (93% vs. 82%, P < 0.01), compared to those of CECT, while A-MRI showed comparable sensitivity (91% vs. 91%, P = 0.42) and accuracy (97% vs. 98%, P = 0.06) to that of standard liver MRI. On a per-lesion-based analysis, A-MRI exhibited significantly superior lesion detectability than that of CECT (figure of merit 0.91 vs. 0.77, P < 0.01) and comparable to that of standard liver MRI (figure of merit 0.91 vs. 0.92, P = 0.75). CONCLUSION: A-MRI exhibited higher sensitivity and diagnostic accuracy than those of CECT in the post-treatment evaluation of RC, while it showed comparable performances with standard liver MRI. A-MRI provides diagnostic added value in the follow-up of RC patients.

2.
Diagnostics (Basel) ; 14(8)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38667435

RESUMEN

The accurate measurement of splenic size is essential for the diagnosis and management of various gastrointestinal and hematological conditions. While ultrasound (US) and computed tomography (CT) are widely used imaging modalities for assessing splenic size, discrepancies between their measurements have been observed in clinical practice. This study aimed to analyze the measurement differences between US and CT and identify factors influencing these differences. A retrospective analysis of 598 asymptomatic patients who underwent both abdominal US and CT was conducted. Measurements of splenic size obtained from US, axial CT, and coronal CT scans were compared, and various factors such as patient demographics, operator experience, and imaging parameters were evaluated to elucidate their impact on the measurement discrepancies. The results revealed that US consistently underestimated splenic size compared to CT. The magnitude of the discrepancy was influenced by factors such as patient age, body mass index (BMI), depth of the spleen from skin on US and that on CT, visibility of the splenic hilum on US, sonic window quality, and operator experience. This study underscores the importance of considering these factors when interpreting splenic measurements obtained from different imaging modalities in clinical practice.

3.
Medicina (Kaunas) ; 60(3)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38541143

RESUMEN

Background and Objectives: Peripherally inserted central catheter (PICC) placement plays an important role in clinical practice. This study aimed to provide an equation for the proper estimation of catheter length in cases of PICC placement without imaging guidance in relation to patient height, weight, sex, and age. Materials and Methods: For 1137 PICC placement cases in both arm veins of 954 patients at a single center, the elbow crease to the cavoatrial junction length (ECL) was calculated as follows: ECL = (PICC length) + (distance from the elbow crease to the puncture site). We analyzed the relationship between ECL and patient characteristics and suggested a new equation for ECL based on height, weight, sex, and age. Results: The average ECL was 48.0 ± 2.4 cm in the right side and 51.0 ± 3.0 cm in the left side. ECL in the right arm was significantly correlated with patient height, sex, and age, whereas the ECL in the left arm was additionally significantly correlated with patient weight. The ECL (cm) prediction model was as follows: right ECL = 26.32 + 1.33 × (female = 1, male = 2) - 0.02 × age (years) + 0.13 × height (cm); left ECL = 22.09 + 1.28 × (female = 1, male = 2) + 0.02 × age (years) + 0.14 × height (cm) + 0.042 × weight (kg). Conclusions: The appropriate PICC length was predicted based on the patient's height, weight, sex, and age. The equations in our study can help predict the optimal catheter length and can be automatically calculated using computerized patient information for bedside procedures in PICC.


Asunto(s)
Cateterismo Venoso Central , Cateterismo Periférico , Humanos , Masculino , Femenino , Cateterismo Venoso Central/métodos , Cateterismo Periférico/métodos , Catéteres , Estudios Retrospectivos
4.
Eye (Lond) ; 38(2): 284-291, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37537389

RESUMEN

OBJECTIVE: The study attempted to identify clinical characteristics associated with structural progression in open-angle glaucoma (OAG) in the presence of MvD in different locations. METHODS: A total of 181 consecutive OAG eyes (follow-up 7.3 ± 4.0 years), which demonstrated peripapillary choroidal MvD (defined as a focal capillary loss with no visible microvascular network in choroidal layer) on optical coherence tomography (OCT) angiography (OCTA), were divided based on the location of MvD. Structural progression was determined using trend-based analysis of the Guided Progression Analysis software of Cirrus OCT. RESULTS: MvD was identified in the temporal quadrant in 110 eyes (temporal MvD; 60.5 ± 12.6 years), and in the inferior quadrant in 71 eyes (inferior MvD; 60.3 ± 11.1 years). After adjusting for age, average intraocular pressure (IOP) and baseline retinal nerve fibre layer (RNFL) thickness and visual field mean deviation, inferior MvD eyes showed faster rates of thinning in the inferior RNFL (mean (95% CI); -0.833 (-1.298 to -0.367)) compared to temporal MvD eyes (-0.144 (-0.496 to 0.207)) when long-term IOP fluctuation was larger than the median value (1.7 mmHg; P = 0.022). Long-term IOP fluctuations were independently associated with inferior RNFL thinning in eyes with inferior MvD (P = 0.002) but not in eyes with temporal MvD. CONCLUSIONS: In OAG eyes, the rates of RNFL and GCIPL thinning were comparable regardless of MvD locations. However, inferior MvD is associated with faster RNFL and GCIPL thinning in the same quadrant when long-term IOP fluctuation is present. Structural progression in the presence of temporal MvD was less associated with IOP fluctuation.


Asunto(s)
Glaucoma de Ángulo Abierto , Disco Óptico , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Células Ganglionares de la Retina , Disco Óptico/irrigación sanguínea , Presión Intraocular , Tomografía de Coherencia Óptica/métodos , Microvasos
6.
Eur Radiol ; 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38114846

RESUMEN

OBJECTIVES: To identify MRI features for differentiating type 2 from type 1 intraductal papillary neoplasms of bile duct (IPNB) and assessing malignant potential of IPNB. METHODS: This retrospective study included 60 patients with surgically proven IPNB who had undergone preoperative MRI between January 2007 and December 2020. All surgical specimens were reviewed retrospectively to classify types 1 and 2 IPNBs and assess tumor grade. Significant MRI features for differentiating type 2 (n = 40) from type 1 IPNB (n = 20); and for IPNB with an associated invasive carcinoma (n = 43) from intraepithelial neoplasia (n = 17) were determined using logistic regression analysis. RESULTS: An associated invasive carcinoma was more frequently found in type 2 than in type 1 IPNB (85.0% [34/40] vs. 45.0% [9/20], p = 0.003). At univariable analysis, MRI features including extrahepatic location, no dilatation of tumor-bearing segment of bile duct, isolated upstream bile duct dilatation, and single lesion were associated with type 2 IPNB (all p ≤ 0.012). At multivariable analysis, significant MRI findings for differentiating type 2 from type 1 IPNB were extrahepatic location and no dilatation of tumor-bearing segment of bile duct (odds ratio [OR], 7.24 and 46.40, respectively). At univariable and multivariable analysis, tumor size ≥ 2.5 cm (OR, 8.45), bile duct wall thickening (OR, 4.82), and irregular polypoid or nodular tumor shape (OR, 6.44) were significant MRI features for differentiating IPNB with an associated invasive carcinoma from IPNB with intraepithelial neoplasia. CONCLUSION: MRI with MR cholangiopancreatography may be helpful in differentiating type 2 IPNB from type 1 IPNB and assessing malignant potential of IPNB. CLINICAL RELEVANCE STATEMENT: Preoperative MRI with MR cholangiopancreatography may be helpful in differentiating type 2 intraductal papillary neoplasms of bile duct (IPNB) from type 1 IPNB and assessing malignant potential of IPNB. KEY POINTS: • In terms of tumor grade, the incidence of invasive carcinoma was significantly higher in type 2 intraductal papillary neoplasm of the bile duct (IPNB) than in type 1 IPNB. • At MRI, extrahepatic location and no dilatation of tumor-bearing segment are significant features for differentiating type 2 IPNBs from type 1 IPNBs. • At MRI, large tumor size, bile duct wall thickening, and irregular polypoid or nodular tumor shape are significant features for differentiating IPNB with an associated invasive carcinoma from IPNB with intraepithelial neoplasia.

7.
Medicina (Kaunas) ; 59(11)2023 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-38004087

RESUMEN

A pseudoaneurysm of the subclavian artery following central venous catheter placement is a rare but potentially fatal complication that often requires surgical intervention. However, surgical repair of the subclavian artery remains challenging. Herein, we report the case of a male patient undergoing hemodialysis who developed a pseudoaneurysm of the subclavian artery after a bedside central vein catheter placement. Hemostasis was successfully achieved by selecting the pseudoaneurysm using a microcatheter. At the 10-month follow-up, the pseudoaneurysm was completely excluded, and the patient was in a stable condition. The patient underwent native arteriovenous fistula creation and hemodialysis. Endovascular treatment could be an effective nonsurgical treatment for subclavian artery pseudoaneurysms and has been attempted as a first-line treatment option.


Asunto(s)
Aneurisma Falso , Cateterismo Venoso Central , Humanos , Masculino , Arteria Subclavia , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Diálisis Renal/efectos adversos , Cateterismo Venoso Central/efectos adversos , Catéteres/efectos adversos
8.
Adv Mater ; 35(52): e2307165, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37945054

RESUMEN

Unlike pigment-based colors, which are determined by their molecular structure, diverse colors can be expressed by a regular arrangement of nanomaterials. However, existing techniques for constructing such nanostructures have struggled to combine high precision and speed, resulting in a narrow gamut, and prolonged color fabrication time. Here, this work reports a phototunable mono ink that can generate a wide range of colors by controlling regularly arranged nanostructure. Core-shell growth controlled by polymerization time precisely regulates the distance between arranged particles at a nanometer-scale, enabling the generation of various colors. Moreover, the wide and thin arrangement induces constrained out-of-plane growth, thus facilitating the intricate color generation at the desired location via photopolymerization. Upon terminating polymerization by oxygen gas, the generated colors are readily fixed and kept stable. Utilizing programmed ultraviolet illumination, large-scale and high-resolution (≈1 µm) full-color printings are demonstrated at high speed (100 mm2 s-1 ).

9.
Medicina (Kaunas) ; 59(11)2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-38003939

RESUMEN

Background: Acute mesenteric ischemia (AMI) is a life-threatening condition, and in 50% of patients, AMI is caused by acute superior mesenteric artery (SMA) embolism. Endovascular treatment is increasingly being considered the primary modality in selected cases. Many studies have reported that percutaneous aspiration embolectomy using a guiding catheter and thrombolysis with recombinant tissue plasminogen activator (rtPA) are effective in treating SMA embolism. However, no reports on treating SMA embolism using rtPA administered via a microcatheter exist. Case presentation: A 64-year-old man with underlying atrial fibrillation presented with acute SMA embolism revealed using computed tomography (CT). rtPA (total 3 mg) was carefully administered into the occluded SMA through a microcatheter. No complications occurred, and complete revascularization of the SMA was revealed on follow-up CT. Conclusions: Compared with previous reports, this case report reveals that successful revascularization can be achieved using rtPA administered via a microcatheter, with a low dose of rtPA and a short duration of thrombolysis.


Asunto(s)
Embolia , Enfermedades Gastrointestinales , Isquemia Mesentérica , Oclusión Vascular Mesentérica , Masculino , Humanos , Persona de Mediana Edad , Activador de Tejido Plasminógeno/uso terapéutico , Arteria Mesentérica Superior , Resultado del Tratamiento , Oclusión Vascular Mesentérica/etiología , Oclusión Vascular Mesentérica/terapia , Embolia/complicaciones , Embolia/tratamiento farmacológico , Isquemia Mesentérica/complicaciones , Isquemia Mesentérica/terapia , Terapia Trombolítica/métodos , Enfermedades Gastrointestinales/complicaciones
10.
ACS Appl Mater Interfaces ; 15(40): 46849-46860, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37773933

RESUMEN

A crystalline silicon (c-Si) solar cell with a polycrystalline silicon/SiOx (poly-Si/SiOx) structure, incorporating both electron and hole contacts, is an attractive choice for achieving ideal carrier selectivity and serving as a fundamental component in high-efficiency perovskite/Si tandem and interdigitated back-contact solar cells. However, our understanding of the carrier transport mechanism of hole contacts remains limited owing to insufficient studies dedicated to its investigation. There is also a lack of comparative studies on the poly-Si/SiOx electron and hole contacts for ideal carrier-selective solar cells. Therefore, this study aims to address these knowledge gaps by exploring the relationship among microstructural evolution, dopant in-diffusion, and the resulting carrier transport mechanism in both the electron and hole contacts of poly-Si/SiOx solar cells. Electron (n+ poly-Si/SiOx/substrate)- and hole (p+ poly-Si/SiOx/substrate)-selective passivating contacts are subjected to thermal annealing. Changes in the passivation properties and carrier transport mechanisms of these contacts are investigated during thermal annealing at various temperatures. Notably, the results demonstrate that the passivation properties and carrier transport mechanisms are strongly influenced by the microstructural evolution of the poly-Si/SiOx layer stack and dopant in-diffusion. Furthermore, electron and hole contacts exhibit common behaviors regarding microstructural evolution and dopant in-diffusion. However, the hole contacts exhibit relatively inferior electrical properties overall, mainly because both the SiOx interface and the p+ poly-Si are found to be highly defective. Moreover, boron in the hole contacts diffuses deeper than phosphorus in the electron contacts, resulting in deteriorated carrier collection. The experimental results are also supported by device simulation. Based on these findings, design rules are suggested for both electron and hole contacts, such as using thicker SiOx and/or annealing the solar cell at a temperature not exceeding the critical annealing temperature of the hole contacts.

11.
Healthcare (Basel) ; 11(16)2023 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-37628469

RESUMEN

BACKGROUND: Perceived stress has a significant effect on metabolic diseases, including obesity and hypertension. However, the association between stress levels, obesity, and hypertension according to age and sex is not fully understood. Therefore, this study investigated the relationship between stress levels and obesity and hypertension in Korean adults and older adults. METHODS: We analyzed data from the 2015 survey of the Korea National Physical Fitness Project conducted by the Korea Institute of Sports Science and the Korea Ministry of Culture, Sports, and Tourism. Of the 3457 participants, 2829 were adults (20-64 years old) and 628 were older adults (≥65 years old). The correlation between obesity and hypertension according to the degree of perceived stress (low, medium, and high) was analyzed using the chi-square test. Binary logistic regression analysis was used to investigate the influence of perceived stress levels on obesity and hypertension. Age, body mass index (BMI), blood pressure, exercise frequency, smoking, breakfast, and sleeping hours were included as covariates. RESULTS: In adult males, perceived stress levels, age, and diastolic blood pressure were found to have a significant impact on obesity rates, whereas age and breakfast had a significant effect on hypertension rates. In adult females, age and systolic blood pressure were found to significantly influence obesity rates, whereas age, BMI, and exercise frequency had a significant impact on hypertension rates. In older adult females, perceived stress levels and systolic blood pressure were found to significantly impact obesity rates, and sleep duration influenced the rates of hypertension. The effect of perceived stress level on obesity and hypertension rates was less pronounced in the elderly population than in the adult population. CONCLUSIONS: This study revealed age and sex differences in the relationship between perceived stress, obesity, and hypertension among Koreans. These findings contribute to a better understanding of the complex relationship between perceived stress and metabolic disorders and emphasize the need for a deeper understanding of the specific factors involved in the prevention and management of metabolic diseases.

12.
Ultrasound Med Biol ; 49(10): 2256-2263, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37495497

RESUMEN

OBJECTIVE: The aim of the work described here was to evaluate the diagnostic performance of perfluorobutane (PFB)-enhanced ultrasound in differentiating hepatocellular carcinoma (HCC) from non-HCC malignancies and other benign lesions using different acquisition methods. METHODS: This prospective study included 69 patients with solid liver lesions larger than 1 cm who were scheduled for biopsy or radiofrequency ablation between September 2020 and March 2021. Lesion diagnosis was designated by three blinded radiologists after reviewing three different sets of acquired images selected according to the following presumed acquisition methods: (i) method A, acquisition up to 5 min after contrast injection; (ii) method B, acquisition up to 1 min after contrast injection with additional Kupffer phase; and (iii) method C, acquisition up to 5 min after contrast injection with additional Kupffer phase. RESULTS: After excluding 7 technical failures, 62 patients with liver lesions (mean size: 24.2 ± 14.8 mm), which consisted of 7 benign lesions, 37 non-HCC malignancies and 18 HCCs. For the HCC diagnosis, method C had the highest sensitivity (75.9%), followed by method B (72.2%) and method A (68.5%), but failed to exhibit statistical significance (p = 0.12). There was no significant difference with respect to the pooled specificity between the three methods (p = 0.28). Diagnostic accuracy was the highest with method C (87.1%) but failed to exhibit statistical significance (p = 0.24). CONCLUSION: Image acquisition up to 5 min after contrast injection with additional Kupffer phase could potentially result in high accuracy and sensitivity without loss of specificity in diagnosing HCC with PFB-enhanced ultrasound.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Estudios Prospectivos , Medios de Contraste , Ultrasonografía/métodos , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Estudios Retrospectivos
13.
Medicina (Kaunas) ; 59(7)2023 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-37512083

RESUMEN

Background and Objectives: Biliary cast syndrome, which was first reported in 1975, is a rare disease that occurs after liver transplantation. The incidence is even lower in patients who have not undergone liver transplantation. This study reports a rare case of biliary cast syndrome with cholangiocarcinoma-like lesions in a patient who did not undergo liver transplantation. Case Report: Herein, we report a case of a 69-year-old man with right upper quadrant pain and elevated levels of alkaline phosphatase and gamma-glutamyl transferase, who had a history of total gastrectomy for gastric cancer and laparoscopic cholecystectomy for acute cholecystitis. Computed tomography (CT) revealed longitudinal bile stones in the extrahepatic and intrahepatic bile ducts and abrupt narrowing of the left main bile duct accompanied by a narrowing of the upstream bile duct in the left lobe of the liver. Based on the CT findings, the removal of the bile stones in the bile duct and additional examinations of the suspected cholangiocarcinoma were performed. The patient's symptoms improved, and examinations for suspected cholangiocarcinoma showed no abnormal findings, and he was discharged one month later. Conclusions: The purpose of this case report is to share a rare case of Biliary Cast Syndrome (BCS) occurring without liver transplantation. Additionally, the report aims to share image findings that mimic cancer in BCS, with the goal of reducing unnecessary repetitive biopsies, minimizing patient discomfort, and decreasing unnecessary costs by aiding in the diagnosis of BCS.


Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Síndrome de la Arteria Mesentérica Superior , Masculino , Humanos , Anciano , Síndrome de la Arteria Mesentérica Superior/patología , Colangiocarcinoma/complicaciones , Conductos Biliares Intrahepáticos , Dolor Abdominal , Neoplasias de los Conductos Biliares/complicaciones , Neoplasias de los Conductos Biliares/cirugía
14.
Medicina (Kaunas) ; 59(6)2023 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-37374325

RESUMEN

Background and Objectives: This study aimed to evaluate the added value of cone-beam computed tomography (CBCT) for detecting hepatocellular carcinomas (HCC) and feeding arteries during transcatheter arterial chemoembolization (TACE). Material and methods: Seventy-six patients underwent TACE and CBCT. We subcategorized patients into groups I (61 patients: possible superselection of tumor/feeding arteries) and II (15 patients: limited superselection of tumor/feeding arteries). We evaluated fluoroscopy time and radiation dose during TACE. Two blinded radiologists independently performed an interval reading based on digital subtraction angiography (DSA) imaging only and DSA combined with CBCT in group I. Result: The mean total fluoroscopy time was 1456.3 ± 605.6 s. The mean dose-area product (DAP), mean DAP of CBCT, and mean ratio of DAP of CBCT to total DAP was 137.1 ± 69.2 Gy cm2, 18.3 ± 7.1 Gy cm2, and 13.3%, respectively. The sensitivity for detecting HCC increased after the additional CBCT reading, from 69.6% to 97.3% and 69.6% to 96.4% for readers 1 and 2, respectively. The sensitivity for detecting feeding arteries increased from 60.3% to 96.6% and 63.8% to 97.4% for readers 1 and 2, respectively. Conclusions: CBCT can increase sensitivity for detecting HCCs and feeding arteries without significantly increasing the radiation exposure.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Exposición a la Radiación , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Arterias/patología , Tomografía Computarizada de Haz Cónico/métodos , Estudios Retrospectivos
15.
Adv Mater ; 35(45): e2302474, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37225649

RESUMEN

Liquid crystals (LCs) technology have a well-established history of applications in visible light, particularly in the display industry. However, with the rapid growth in communication technology, LCs have become a topic of current interest for high-frequency microwave (MW) and millimeter-wave (mmWave) applications due to promising characteristics such as tunability, continuous tuning, low losses, and price compatibility. To improve the performance of future communication technology using LCs, it is not sufficient only with the perspective of radio-frequency (RF) technology. Therefore, it is imperative to understand not only the novel structural designs and optimization of MW engineering but also the perspective of materials engineering when implementing advanced RF devices with maximum performance for next-generation satellite and terrestrial communication. Herein, based on advanced nematic LCs, polymer-modified LCs, dual-frequency LCs, and photo-reactive LCs, this article summarizes and examines the modulation principles and key research directions for the design strategies of LCs for advanced smart RF devices with improved driving performance and novel functionality. Furthermore, the challenges in development of state-of-the-art smart RF devices that use LCs are discussed.

16.
PLoS One ; 18(4): e0285017, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37104301

RESUMEN

PURPOSE: To identify peripapillary choroidal microvasculature dropout (MvD) in eyes with optic neuritis and its association with longitudinal changes in retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GCIP) thicknesses following diagnosis. METHODS: A total of 48 eyes with optic neuritis was evaluated to identify the presence of peripapillary choroidal MvD, defined as a focal capillary loss with no visible microvascular network in choroidal layer, using optical coherence tomography (OCT) angiography (OCTA). Patients were divided based on the presence of MvD. OCT and standard automated perimetry (SAP) conducted at 1, 3 and 6 months follow-up were analyzed. RESULTS: MvD was identified in 20 of 48 eyes (41.7%) with optic neuritis. MvD was most commonly found in the temporal quadrant (85.0%), and peripapillary retinal vessel density in the temporal quadrant was significantly lower in eyes with MvD (P = 0.012). At 6 months follow-up, optic neuritis eyes with MvD showed significantly thinner GCIP in superior, superotemporal, inferior and inferotemporal sectors (P<0.05). No significant difference was noted in SAP parameters. The presence of MvD was significantly associated with thinner global GCIP thickness at 6 months follow-up (OR 0.909, 95% CI 0.833-0.992, P = 0.032). CONCLUSION: Optic neuritis showed peripapillary choroidal microvascular impairment in the form of MvD. MvD was associated with structural deterioration at macular GCIP. Further studies are necessary to identify the causal relationship between microvascular impairment and retinal nerve fiber layer damage in optic neuritis.


Asunto(s)
Disco Óptico , Neuritis Óptica , Enfermedades de la Retina , Humanos , Disco Óptico/diagnóstico por imagen , Disco Óptico/irrigación sanguínea , Campos Visuales , Células Ganglionares de la Retina , Fibras Nerviosas , Tomografía de Coherencia Óptica/métodos , Neuritis Óptica/diagnóstico por imagen , Microvasos/diagnóstico por imagen , Pronóstico
17.
Diagnostics (Basel) ; 13(6)2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36980314

RESUMEN

It is challenging to overcome motion artifacts in diffusion-weighted imaging (DWI) of the abdomen. This study aimed to evaluate the image quality of motion-corrected DWI of the liver using non-rigid registration in comparison with conventional DWI (c-DWI) in patients with liver diseases. Eighty-nine patients who underwent 3-T magnetic resonance imaging (MRI) of the liver were retrospectively included. DWI was performed using c-DWI and non-rigid motion-corrected (moco) DWI was performed in addition to c-DWI. The image quality and conspicuity of hepatic focal lesions were scored using a five-point scale by two radiologists and compared between the two DWI image sets. The apparent diffusion coefficient (ADC) was measured in three regions of the liver parenchyma and in hepatic focal lesions, and compared between the two DWI image sets. Moco-DWI achieved higher scores in image quality compared to c-DWI in terms of liver edge sharpness and hepatic vessel margin delineation. The conspicuity scores of hepatic focal lesions were higher in moco-DWI. The standard deviation values of ADC of the liver parenchyma were lower in the moco-DWI than in the c-DWI. Moco-DWI using non-rigid registration showed improved overall image quality and provided more reliable ADC measurement, with an equivalent scan time, compared with c-DWI.

18.
Diagnostics (Basel) ; 13(3)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36766584

RESUMEN

Preoperative diagnosis of borderline ovarian tumors (BOTs) is of increasing concern. This study aimed to determine computed tomography (CT) features in differentiating stage 1 BOTs from stage I malignant epithelial ovarian tumors (MEOTs). A total of 170 ovarian masses (97 BOTs and 73 MEOTs) from 141 consecutive patients who underwent preoperative CT imaging were retrospectively analyzed. Two readers independently and retrospectively reviewed quantitative and qualitative CT features. Multivariate logistic analysis demonstrated that a larger tumor size (p = 0.0284 for reader 1, p = 0.0391 for reader 2) and a smaller solid component (p = 0.0007 for reader 1, p = 0.0003 for reader 2) were significantly associated with BOTs compared with MEOTs. In the subanalysis of cases with a solid component, smaller (p = 0.0092 for reader 1, p = 0.0014 for reader 2) and ill-defined (p = 0.0016 for reader 1, p = 0.0414 for reader 2) solid component was significantly associated with BOTs compared with MEOTs. Tumor size and the size and margin of the solid component were useful for differentiating stage 1 BOTs from stage 1 MEOTs on CT images.

20.
Mar Pollut Bull ; 188: 114612, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36682303

RESUMEN

In this study, we investigated the influence of fish-farm activities on the inventory of trace elements (Mn, Fe, Co, Ni, and Cu) in the coastal waters off the fish-farm plants on Jeju Island, Korea. NH4+ and rare earth elements (REEs) were used as tracers to examine the production and removal processes. Relatively higher concentrations of trace elements were observed in the coastal waters and significantly correlated with NH4+. Our results suggest that the excess dissolved trace elements in the coastal waters could be mainly produced inside fish farms, together with the production of NH4+ and light-REEs (La to Nd). Although dissolved trace elements were found to be partially scavenged onto particles in the fish-farm rearing waters, indicated by the significant removal of particle-reactive Ce, these particles would be eventually discharged into the coastal ocean and release the dissolved trace elements back into the water columns.


Asunto(s)
Metales de Tierras Raras , Oligoelementos , Oligoelementos/análisis , Amoníaco , Explotaciones Pesqueras , Monitoreo del Ambiente/métodos , Metales de Tierras Raras/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...