Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Geriatr Gerontol Int ; 24(2): 204-210, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38199969

RESUMEN

The prognostic implication of cognitive frailty assessment in patients undergoing left ventricular assist device (LVAD) implantation remains unclear. We conducted a systematic review to evaluate assessment strategies and their significance for patients undergoing LVAD implantation. A comprehensive search of PubMed, Embase, and the Cumulative Index to Nursing and Allied Health Literature from inception until September 2022 and a review of meeting proceedings were performed following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies that investigated the prognostic value of cognitive frailty or any related cognition-based assessment in patients undergoing LVAD implantation were included. Study characteristics, patient demographics, and type of cognitive assessment were extracted. Primary outcomes included length of stay, readmissions, and all-cause mortality. Of 664 records retrieved, 12 (4 prospective, 8 retrospective) involving 16 737 subjects (mean age, 56.9 years; 78.3% men) met inclusion criteria; 67% of studies used the Montreal Cognitive Assessment to assess cognitive frailty. Outcomes reported were highly variable, with 42% reporting readmission, 33% reporting LOS, and 83% reporting mortality data; only two studies provided data on all three. Cognitive frailty was associated with prolonged length of stay in 75% of studies reporting this outcome. Only 40% and 60% of studies that reported readmissions and mortality outcomes, respectively, suggested a predictive association. Pre-LVAD cognitive frailty is likely associated with worse outcomes postimplant. However, the heterogenous reporting of outcomes data and lack of consistent definitions in the literature limit its prognostic value. Additional research on markers for cognitive frailty and improved standards of reporting may allow for future analyses and enhance preoperative risk assessment and patient care. Geriatr Gerontol Int 2024; 24: 204-210.


Asunto(s)
Fragilidad , Insuficiencia Cardíaca , Corazón Auxiliar , Masculino , Humanos , Femenino , Fragilidad/diagnóstico , Estudios Retrospectivos , Estudios Prospectivos , Selección de Paciente , Insuficiencia Cardíaca/terapia
2.
ASAIO J ; 70(1): 14-21, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37788482

RESUMEN

Minorities are less likely to receive a left ventricular assist device (LVAD). This, however, is based on total implant data. By examining rates of LVAD implant among patients admitted with heart failure complicated by cardiogenic shock, we sought to further elucidate LVAD utilization rates and racial disparities. Utilizing the National Inpatient Sample from 2013 to 2019, all patients admitted with a primary diagnosis of heart failure complicated by cardiogenic shock were included for analysis. Those who then received an LVAD during that hospitalization defined the LVAD utilization which was examined for any racial disparities. Left ventricular assist device utilization was low across all racial groups with no significant difference noted in univariate analysis. Non-Hispanic Blacks had the highest length of stay (LOS), the highest proportion of discharge to home (71.52%), and the lowest inpatient mortality (6.33%). Multivariable modeling confirmed the relationship between race and LOS; however, no differences were noted in mortality. Non-Hispanic Blacks were found to be less likely to receive an LVAD; however, when controlling for payer, median household income, and comorbidities, this relationship was no longer seen. Left ventricular assist devices remain an underutilized therapy in cardiogenic shock. When using a multivariable model, race does not appear to affect LVAD utilization.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Choque Cardiogénico/terapia , Pacientes Internos , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
3.
Innovations (Phila) ; 19(1): 46-53, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38013250

RESUMEN

OBJECTIVE: Impella 5.5 (Abiomed, Danvers, MA, USA) is approved by the US Food and Drug Administration (FDA) for mechanical circulatory support for ≤14 days. It is unknown whether prolonged support is associated with worse outcomes. We sought to review our single-center experience with Impella 5.5 and compare outcomes based on support duration. METHODS: We retrospectively reviewed adult patients (≥18 years old) supported with Impella 5.5 at our institution (May 2020 to April 2023). Patients on prolonged support (>14 days) were compared with those supported for ≤14 days. RESULTS: There were 31 patients supported with Impella 5.5 including 14 (45.2%) supported >14 days. Median support duration for those on prolonged support was 43.5 (interquartile range [IQR] 25 to 63.5) days versus 8 (IQR 6, 13) days for those who were not (P < 0.001). Overall, the device-related complication rate was 9.7% and did not differ between groups (P = 0.08). Overall, 30-day postimplant survival was 71% and did not differ by support duration (P = 0.2). In-hospital mortality was 32% and did not differ between cohorts (P > 0.99). Among those surviving to explant (n = 22), long-term strategy included bridge to durable ventricular assist device (18%, n = 4), cardiac transplant (55%, n = 12), and cardiac recovery (27%, n = 6). CONCLUSIONS: High-risk patients with cardiogenic shock may be supported with Impella 5.5 beyond the FDA-approved duration without increased risk of complications or mortality.


Asunto(s)
Trasplante de Corazón , Corazón Auxiliar , Adulto , Estados Unidos/epidemiología , Humanos , Adolescente , Estudios Retrospectivos , United States Food and Drug Administration , Resultado del Tratamiento , Choque Cardiogénico/etiología , Corazón Auxiliar/efectos adversos
4.
Am J Cardiol ; 210: 85-92, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37852567

RESUMEN

We describe 2 challenging cases of cardiac transthyretin amyloidosis initially treated as cardiac amyloidosis light chain in the setting of active myeloma. Endomyocardial biopsy with mass spectrometry was essential to confirm the appropriate diagnosis to direct the treatment.


Asunto(s)
Neuropatías Amiloides Familiares , Cardiomiopatías , Mieloma Múltiple , Humanos , Mieloma Múltiple/complicaciones , Mieloma Múltiple/diagnóstico , Cardiomiopatías/diagnóstico , Prealbúmina , Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/diagnóstico , Corazón
5.
Am J Cardiol ; 207: 271-279, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37769570

RESUMEN

Recurrence of cardiac sarcoidosis (CS) and giant cell myocarditis (GCM) after heart transplant is rare, with rates of 5% in CS and 8% in GCM. We aim to identify all reported cases of recurrence in the literature and to assess clinical course, treatments, and outcomes to improve understanding of the conditions. A systematic review, utilizing Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines, was conducted by searching MEDLINE/PubMed and Embase of all available literature describing post-transplant recurrent granulomatous myocarditis, CS, or GCM. Data on demographics, transplant, recurrence, management, and outcomes data were collected from each publication. Comparison between the 2 groups were made using standard statistical approaches. Post-transplant GM recurrence was identified in 39 patients in 33 total publications. Reported cases included 24 GCM, 12 CS, and 3 suspected cases. Case reports were the most frequent form of publication. Mean age of patients experiencing recurrence was 42 years for GCM and 48 years for CS and favored males (62%). Time to recurrence ranged from 2 weeks to 9 years post-transplant, occurring earlier in GCM (mean 1.8 vs 3.0 years). Endomyocardial biopsies (89%) were the most utilized diagnostic method over cardiac magnetic resonance and positron emission tomography. Recurrence treatment regimens involved only steroids in 40% of CS, whereas other immunomodulatory regimens were utilized in 70% of GCM. In conclusion, GCM and CS recurrence after cardiac transplantation holds associated risks including concurrent acute cellular rejection, a higher therapeutic demand for GCM recurrence compared with CS, and mortality. New noninvasive screening techniques may help modify post-transplant monitoring regimens to increase both early detection and treatment of recurrence.


Asunto(s)
Cardiomiopatías , Trasplante de Corazón , Miocarditis , Sarcoidosis , Adulto , Humanos , Masculino , Biopsia , Cardiomiopatías/diagnóstico , Cardiomiopatías/etiología , Cardiomiopatías/patología , Células Gigantes/patología , Trasplante de Corazón/efectos adversos , Miocarditis/diagnóstico , Miocarditis/etiología , Miocarditis/terapia , Sarcoidosis/diagnóstico , Sarcoidosis/patología
6.
Eur Heart J Case Rep ; 7(8): ytad394, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37654803

RESUMEN

Background: An intra-aortic balloon pump (IABP) is a mechanical circulatory support platform with a relatively low complication rate. Axillary access is increasingly utilized to allow rehabilitation. Case summary: We present a case of femoral IABP inserted into the femoral artery percutaneously via a sheathless technique that allowed the patient to ambulate and physically rehabilitate over 102 days until cardiac transplantation. The patient was able to progress with the protocolized rehabilitation programme to up to 3500 ft walking distance. The IABP was removed at the time of transplantation without any vascular complications. Discussion: While axillary IABP offers an opportunity to rehabilitate, it has an unacceptably high complication rate, often resulting in vascular injury that adds morbidity to an acutely ill cohort. In this case, we found that sheathless femoral IABP access offered stability for a prolonged time while avoiding pain, bleeding, infection, and vascular injury. We hypothesize that this is due to less indwelling prosthetic material usage and also device flexibility, allowing conformation to the natural course of the femoral artery. We are encouraged by this case to use a sheathless access approach for patients expected to require prolonged IABP support.

7.
J Heart Lung Transplant ; 42(11): 1597-1607, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37307906

RESUMEN

BACKGROUND: Intra-aortic balloon pump (IABP) and Impella device utilization as a bridge to heart transplantation (HTx) have risen exponentially. We aimed to explore the influence of device selection on HTx outcomes, considering regional practice variation. METHODS: A retrospective longitudinal study was performed on a United Network for Organ Sharing (UNOS) registry dataset. We included adult patients listed for HTx between October 2018 and April 2022 as status 2, as justified by requiring IABP or Impella support. The primary end-point was successful bridging to HTx as status 2. RESULTS: Of 32,806 HTx during the study period, 4178 met inclusion criteria (Impella n = 650, IABP n = 3528). Waitlist mortality increased from a nadir of 16 (in 2019) to a peak of 36 (in 2022) per thousand status 2 listed patients. Impella annual use increased from 8% in 2019 to 19% in 2021. Compared to IABP, Impella patients demonstrated higher medical acuity and lower success rate of transplantation as status 2 (92.1% vs 88.9%, p < 0.001). The IABP:Impella utilization ratio varied widely between regions, ranging from 1.77 to 21.31, with high Impella use in Southern and Western states. However, this difference was not justified by medical acuity, regional transplant volume, or waitlist time and did not correlate with waitlist mortality. CONCLUSIONS: The shift in utilizing Impella as opposed to IABP did not improve waitlist outcomes. Our results suggest that clinical practice patterns beyond mere device selection determine successful bridging to HTx. There is a critical need for objective evidence to guide tMCS utilization and a paradigm shift in the UNOS allocation system to achieve equitable HTx practice across the United States.

8.
Am J Med ; 136(8): 745-752, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37148990

RESUMEN

Heart failure carries significant morbidity and mortality and affects a large population of patients cared for predominantly by primary care physicians. The complexity of managing heart failure patients is increasing as new therapies continue to emerge. This review outlines important clinical pearls and proposes strategies for optimization of medical therapy.


Asunto(s)
Insuficiencia Cardíaca , Médicos , Humanos , Volumen Sistólico
9.
Cardiol Rev ; 2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36881614

RESUMEN

Frailty is associated with poor clinical outcomes in heart failure patients. The impact of frailty on outcomes following left ventricular assist device (LVAD) implantation, however, is less clearly defined. We therefore sought to conduct a systematic review to evaluate current frailty assessment strategies and their significance for patients undergoing LVAD implantation. We conducted a comprehensive electronic search of PubMed, Embase, and CINAHL databases from inception until April 2021 for studies examining frailty in patients undergoing LVAD implantation. Study characteristics, patient demographics, type of frailty measurement, and outcomes were extracted. Outcomes were organized into 5 basic categories: implant length of stay (iLOS), 1-year mortality, rehospitalization, adverse events, and quality of life (QOL). Of the 260 records retrieved, 23 studies involving 4935 patients satisfied the inclusion criteria. Approaches to measuring frailty varied, with the 2 most common being sarcopenia determined by computed tomography and Fried's frailty phenotype assessment. Outcomes of interest were also widely variable, with iLOS stay and mortality being the most frequently reported, albeit with differing definitions of both between studies. The heterogeneity among included studies precluded quantitative synthesis. Narrative synthesis showed that frailty by any measure is more likely to be associated with higher mortality, longer iLOS, more adverse events and worse QOL post-LVAD implant. Frailty can be a valuable prognostic indicator in patients undergoing LVAD implantation. Further studies are needed to determine the most sensitive frailty assessment, as well as the ways in which frailty may serve as a modifiable target to improve outcomes following LVAD implantation.

10.
Front Cardiovasc Med ; 10: 1127716, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36910520

RESUMEN

Introduction: Artificial intelligence can recognize complex patterns in large datasets. It is a promising technology to advance heart failure practice, as many decisions rely on expert opinions in the absence of high-quality data-driven evidence. Methods: We searched Embase, Web of Science, and PubMed databases for articles containing "artificial intelligence," "machine learning," or "deep learning" and any of the phrases "heart transplantation," "ventricular assist device," or "cardiogenic shock" from inception until August 2022. We only included original research addressing post heart transplantation (HTx) or mechanical circulatory support (MCS) clinical care. Review and data extraction were performed in accordance with PRISMA-Scr guidelines. Results: Of 584 unique publications detected, 31 met the inclusion criteria. The majority focused on outcome prediction post HTx (n = 13) and post durable MCS (n = 7), as well as post HTx and MCS management (n = 7, n = 3, respectively). One study addressed temporary mechanical circulatory support. Most studies advocated for rapid integration of AI into clinical practice, acknowledging potential improvements in management guidance and reliability of outcomes prediction. There was a notable paucity of external data validation and integration of multiple data modalities. Conclusion: Our review showed mounting innovation in AI application in management of MCS and HTx, with the largest evidence showing improved mortality outcome prediction.

11.
Skin Health Dis ; 3(1): e166, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36751310

RESUMEN

Despite the UK's population rapidly diversifying, the representation of dermatological conditions in skin of colour in education, medical resources, and clinical practice is lagging. Furthermore, resources and advancements created by recent initiatives appear not to be communicated to the general public and are not integrated into medical curricula. In this perspective article, we share our experience from a public-engagement campaign in South West England and propose that student-led initiatives hold the potential to close the existing gap in diversity and racial equity in dermatology by communicating recent efforts within the medical field to the general public. We describe how student-led initiatives allow medical students to advocate for diversity and equity within their institutions while delivering much-needed education to ethnically minoritised communities.

12.
Cureus ; 15(12): e51160, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38283491

RESUMEN

The left ventricular assist device (LVAD) is a mechanical circulatory support device that supports the heart failure patient as a bridge to transplant (BTT) or as a destination therapy for those who have other medical comorbidities or complications that disqualify them from meeting transplant criteria. In patients with severe heart failure, LVAD use has extended survival and improved signs and symptoms of cardiac congestion and low cardiac output, such as dyspnea, fatigue, and exercise intolerance. However, these devices are associated with specific hematologic and thrombotic complications. In this manuscript, we review the common hematologic complications of LVADs.

13.
Chest ; 161(4): e209-e212, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35396053

RESUMEN

CASE PRESENTATION: A 31-year-old man with a medical history of well-controlled asthma presented with a 3-week history of midsternal chest pressure and shortness of breath. His symptoms were associated with malaise, weakness, 40-pound weight loss over several months, and intermittent fever up to 38.3ºC. A week and half earlier, he started experiencing a productive cough with white sputum and arthralgias in his knees. He denied any exacerbating or relieving factors for his symptoms. Additionally, he had a pruritic rash on his thighs for the last year that remained unresolved despite antifungal medication.


Asunto(s)
Asma , Disnea , Adulto , Asma/complicaciones , Asma/diagnóstico , Tos/diagnóstico , Disnea/diagnóstico , Disnea/etiología , Fiebre , Humanos , Masculino
14.
J Cardiovasc Pharmacol ; 79(5): 646-649, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35058410

RESUMEN

ABSTRACT: Left ventricular assist device (LVAD) implantation is increasingly utilized in patients with advanced heart failure and morbid obesity. Laparoscopic sleeve gastrectomy (LSG) can facilitate weight loss in this population and can ultimately change the pharmacokinetics of heart failure therapeutics. In this study, we aimed to explore the changes in cardiovascular pharmacotherapy post LSG intervention. We conducted a retrospective observational cohort study of morbidly obese LVAD patients between 2013 and 2019 at the University of Florida with available pharmacotherapeutic data at 1 and 6 months. Thirteen post-LSG patients and 13 control subjects were included in the final analysis. In the post-LSG group, the mean body mass index decreased significantly (44 ± 5 vs. 34 ± 4.9, P < 0.001), and 7 patients were successfully bridged to cardiac transplantation. Only 3 patients required adjustment of their LVAD speed. Mean return to flow decreased by 8 mm Hg, despite a 45% reduction in the mean number of vasodilators per patient (1.2 vs. 0.7, P = 0.03). Mean weekly warfarin dose decreased by 35% after 6 months (32.9 ± 20.9 vs. 50.7 ± 26.6, P = 0.01). The use of diuretics, vasodilators, and beta-blockers was significantly reduced by 50%, 45%, and 35%, respectively. None of these changes were observed in the control group at 6-month follow-up post LVAD. In this single-center experience, weight loss post LSG is associated with decreased vasodilator, diuretic, and anticoagulant medication requirements in LVAD patients.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Laparoscopía , Obesidad Mórbida , Índice de Masa Corporal , Gastrectomía/efectos adversos , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Laparoscopía/efectos adversos , Obesidad Mórbida/diagnóstico , Obesidad Mórbida/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Vasodilatadores , Pérdida de Peso
15.
J Card Surg ; 37(4): 1063-1065, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35064697

RESUMEN

Temporary mechanical circulatory support (MCS) systems are indicated to stabilize hemodynamically decompensating patients in cardiogenic shock refractory to medical management. These devices are currently used as short-term hemodynamic support to facilitate organ recovery or bridge to definitive therapy with durable MCS or heart transplantation. We present the sequential use of intra-aortic balloon pump, Impella 5.5®, and venoarterial extracorporeal membrane oxygenation as a bridge to heart-liver-kidney transplantation. The patient was supported for 78 days on Impella 5.5 and 95 days total temporary MCS. He had an uncomplicated postoperative course after triple-organ transplantation and was stable with no signs of rejection at 1-, 3-, 6-, and 12-month follow-up.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trasplante de Corazón , Corazón Auxiliar , Humanos , Contrapulsador Intraaórtico , Masculino , Choque Cardiogénico/etiología , Choque Cardiogénico/cirugía
16.
Front Physiol ; 12: 672252, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34539423

RESUMEN

People affected by diabetes are at an increased risk of developing heart failure than their non-diabetic counterparts, attributed in part to a distinct cardiac pathology termed diabetic cardiomyopathy. Mitochondrial dysfunction and excess reactive oxygen species (ROS) have been implicated in a range of diabetic complications and are a common feature of the diabetic heart. In this study, we sought to characterise impairments in mitochondrial structure and function in a recently described experimental mouse model of diabetic cardiomyopathy. Diabetes was induced in 6-week-old male FVB/N mice by the combination of three consecutive-daily injections of low-dose streptozotocin (STZ, each 55 mg/kg i.p.) and high-fat diet (42% fat from lipids) for 26 weeks. At study end, diabetic mice exhibited elevated blood glucose levels and impaired glucose tolerance, together with increases in both body weight gain and fat mass, replicating several aspects of human type 2 diabetes. The myocardial phenotype of diabetic mice included increased myocardial fibrosis and left ventricular (LV) diastolic dysfunction. Elevated LV superoxide levels were also evident. Diabetic mice exhibited a spectrum of LV mitochondrial changes, including decreased mitochondria area, increased levels of mitochondrial complex-III and complex-V protein abundance, and reduced complex-II oxygen consumption. In conclusion, these data suggest that the low-dose STZ-high fat experimental model replicates some of the mitochondrial changes seen in diabetes, and as such, this model may be useful to study treatments that target the mitochondria in diabetes.

17.
BMJ Case Rep ; 14(4)2021 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-33875513

RESUMEN

A middle-aged woman who received heart transplantation for end-stage sarcoid cardiomyopathy developed recurrent cardiac sarcoidosis in the donor heart. She presented 5 years post-transplantation with heart block and systolic dysfunction, without extracardiac involvement. Her disease was unresponsive to corticosteroids. Routine functional imaging may help identify such recurrences.


Asunto(s)
Cardiomiopatías , Trasplante de Corazón , Sarcoidosis , Arritmias Cardíacas , Cardiomiopatías/diagnóstico , Femenino , Humanos , Persona de Mediana Edad , Sarcoidosis/complicaciones , Sarcoidosis/diagnóstico , Sarcoidosis/tratamiento farmacológico , Donantes de Tejidos
18.
Heart Lung Circ ; 30(9): 1389-1396, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33863665

RESUMEN

BACKGROUND: Pulmonary artery proportional pulse pressure (PAPP) was recently shown to have prognostic value in heart failure (HF) with reduced ejection fraction (HFrEF) and pulmonary hypertension. We tested the hypothesis that PAPP would be predictive of adverse outcomes in patients with implantable pulmonary artery pressure monitor (CardioMEMS™ HF System, St. Jude Medical [now Abbott], Atlanta, GA, USA). METHODS: Survival analysis with Cox proportional hazards regression was used to evaluate all-cause deaths and HF hospitalisation (HFH) in CHAMPION trial1 patients who received treatment with the CardioMEMS device based on the PAPP. RESULTS: Among 550 randomised patients, 274 had PAPP ≤ the median value of 0.583 while 276 had PAPP>0.583. Patients with PAPP≤0.583 (versus PAPP>0.583) had an increased risk of HFH (HR 1.40, 95% CI 1.16-1.68, p=0.0004) and experienced a significant 46% reduction in annualised risk of death with CardioMEMS treatment (HR 0.54, 95% CI 0.31-0.92) during 2-3 years of follow-up. This survival benefit was attributable to the treatment benefit in patients with HFrEF and PAPP≤0.583 (HR 0.50, 95% CI 0.28-0.90, p<0.05). Patients with PAPP>0.583 or HF with preserved EF (HFpEF) had no significant survival benefit with treatment (p>0.05). CONCLUSION: Lower PAPP in HFrEF patients with CardioMEMS constitutes a higher mortality risk status. More studies are needed to understand clinical applications of PAPP in implantable pulmonary artery pressure monitors.


Asunto(s)
Insuficiencia Cardíaca , Presión Sanguínea , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Piperazinas , Pronóstico , Arteria Pulmonar , Volumen Sistólico
19.
Heart Fail Rev ; 26(2): 355-361, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32997214

RESUMEN

Intravenous inotropic therapy can be used in patients with advanced heart failure, as palliative therapy or as a bridge to cardiac transplantation or mechanical circulatory support, as well as in cardiogenic shock. Their use is limited to increasing cardiac output in low cardiac output states and reducing ventricular filling pressures to alleviate patient symptoms and improve functional class. Many advanced heart failure patients have sinus tachycardia as a compensatory mechanism to maintain cardiac output. However, excessive sinus tachycardia caused by intravenous inotropes can increase myocardial oxygen consumption, decrease coronary perfusion, and at extreme heart rates decrease ventricular filling and stroke volume. The limited available hemodynamic studies support the hypothesis that adding ivabradine, a rate control agent without negative inotropic effect, may blunt inotrope-induced tachycardia and its associated deleterious effects, while optimizing cardiac output by increasing stroke volume. This review analyzes the intriguing pathophysiology of combined intravenous inotropes and ivabradine to optimize the hemodynamic profile of patients in advanced heart failure. Graphical abstract Illustration of the beneficial and deleterious hemodynamic effects of intravenous inotropes in advanced heart failure, and the positive effects of adding ivabradine.


Asunto(s)
Cardiotónicos , Insuficiencia Cardíaca , Cardiotónicos/farmacología , Insuficiencia Cardíaca/tratamiento farmacológico , Frecuencia Cardíaca , Hemodinámica , Humanos , Ivabradina , Volumen Sistólico
20.
J Card Surg ; 36(4): 1569-1571, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33331047

RESUMEN

Fulminant myocarditis is a rapidly progressive myocardial inflammation that commonly requires advanced circulatory support therapies. We report our management of a 36-year-old gentleman with fulminant myocarditis who we managed with extracorporeal membranous oxygenation (ECMO) and subsequently durable bi-ventricular assist devices as a bridge to heart transplantation. The patient was admitted after a 1-week history of malaise with severe lethargy, jugular venous distension to greater than 10 cm, and troponin elevation to greater than 27 K. He was taken immediately for a heart catheterization which showed no obstructive coronary disease, and hemodynamics consistent with bi-ventricular failure. We proceeded with ECMO for hemodynamic support, utilizing a mini-thoracotomy for cannulation. A Protek Duo Rapid Deployment (LivaNova) was inserted via a modified Seldinger technique through the left ventricular apex, terminating in the ascending aorta. Percutaneous right IJ bicaval via a y-ed Avalon Elite (Getinge) was employed for venous drainage. This case highlights an alternate strategy for central walking veno-arterial ECMO in a patient presenting with fulminant myocarditis with a platform that minimizes upper/lower extremity over/under perfusion complications, while providing sternal sparring antegrade arterial flow with simultaneous ventricular unloading/venting.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Toracotomía , Caminata
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...