Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-37561112

RESUMEN

OBJECTIVE: To compare 4 point-of-care (POC) techniques to assess nasogastric (NG) tube placement versus radiographs as a reference standard. POC methods included air inflation with auscultation, fluid aspiration with pH measurement, ultrasonography, and capnography. DESIGN: Prospective observational study in hospitalized dogs between 2020 and 2021. SETTING: University teaching hospital. ANIMALS: Fifty-one dogs requiring NG tube placement as part of their normal care. INTERVENTIONS: After standard blind NG tube placement, each POC method was performed following standardized instructions. All POC methods were scored as to whether the investigator believed the tube to be in the gastrointestinal tract (as indicated by positive auscultation of borborygmus during insufflation, positive fluid aspiration with pH ≤5, presence of hyperechoic shadow in the esophagus, or absence of capnographic waveform). Subsequently, radiographs were taken to determine NG tube position as a gold standard. The sensitivity, specificity, and accuracy of each test as compared to 2-view thoracic radiographs were determined. MEASUREMENTS AND MAIN RESULTS: Sensitivity, specificity, and accuracy for each POC technique were as follows: air auscultation (84.4%, 50.5%, and 80.4%, respectively), neck ultrasound (95.6%, 83.3%, and 94.1%, respectively), capnography (91.1%, 33.3%, and 84.3%, respectively), and fluid aspiration with pH measurement (22.2%, 100%, and 31.4%, respectively). CONCLUSIONS: Among the 4 techniques evaluated, neck ultrasound had the best overall performance for assessing NG tube placement. Fluid aspiration with pH measurement might also have potential due to perfect specificity, but its clinical utility may be limited by low sensitivity and accuracy. Nonetheless, 2-view thoracic radiography should still be considered the standard method for confirmation of NG tube placement as none of the 4 POC techniques investigated showed both high sensitivity and perfect specificity.


Asunto(s)
Intubación Gastrointestinal , Sistemas de Atención de Punto , Humanos , Perros , Animales , Intubación Gastrointestinal/veterinaria , Intubación Gastrointestinal/métodos , Auscultación , Esófago , Capnografía/veterinaria , Capnografía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...