Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Vet Res ; 18(1): 422, 2022 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-36463174

RESUMEN

BACKGROUND: The On-Off, or long flash, full field electroretinogram (ERG) separates retinal responses to flash onset and offset. Depending on degree of dark-adaptation and stimulus strength the On and Off ERG can be shaped by rod and cone photoreceptors and postreceptoral cells, including ON and OFF bipolar cells. Interspecies differences have been shown, with predominantly positive Off-response in humans and other primates and a negative Off-response in rodents and dogs. However, the rod signaling pathways that contribute to these differential responses have not been characterized. In this study, we designed a long flash protocol in the dog that varied in background luminance and stimulus strength allowing for some rod components to be present to better characterize how rod pathways vary from scotopic to mesopic conditions. RESULTS: With low background light the rod a-wave remains while the b-wave is significantly reduced resulting in a predominantly negative waveform in mesopic conditions. Through modeling and subtraction of the rod-driven response, we show that rod bipolar cells saturate with dimmer backgrounds than rod photoreceptors, resulting in rod hyperpolarization contributing to a large underlying negativity with mesopic backgrounds. CONCLUSIONS: Reduction in rod bipolar cell responses in mesopic conditions prior to suppression of rod photoreceptor responses may reflect the changes in signaling pathway of rod-driven responses needed to extend the range of lighting conditions over which the retina functions.


Asunto(s)
Retina , Transducción de Señal , Humanos , Perros , Animales
2.
Vet Ophthalmol ; 25(5): 385-397, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35713167

RESUMEN

OBJECTIVES: To assess an inherited abnormal negative response electroretinogram (NRE) that originated in a family of Papillon dogs. ANIMALS STUDIED: Thirty-eight dogs (Papillons, or Papillon cross Beagles or Beagles). PROCEDURES: Dogs underwent routine ophthalmic examination and a detailed dark-adapted, light-adapted and On-Off electroretinographic study. Vision was assessed using a four-choice exit device. Spectral-domain optical coherence tomography (SD-OCT) was performed on a subset of dogs. Two affected males were outcrossed to investigate the mode of inheritance of the phenotype. RESULTS: The affected dogs had an increased underlying negative component to the ERG. This was most pronounced in the light-adapted ERG, resulting in a reduced b-wave and an exaggerated photopic negative response (PhNR). Changes were more pronounced with stronger flashes. Similarly, the On-response of the On-Off ERG had a reduced b-wave and a large post-b-wave negative component. The dark-adapted ERG had a significant increase in the scotopic threshold response (STR) and a significant reduction in the b:a-wave ratio. Significant changes could be detected at 2 months of age but became more pronounced with age. Vision testing using a four-choice device showed affected dogs had reduced visual performance under the brightest light condition. There was no evidence of a degenerative process in the affected dogs up to 8.5 years of age. Test breeding results suggested the NRE phenotype had an autosomal dominant mode of inheritance. CONCLUSIONS: We describe an inherited ERG phenotype in Papillon dogs characterized by an underlying negative component affecting both dark- and light-adapted ERG responses.


Asunto(s)
Enfermedades de los Perros , Enfermedades de la Retina , Animales , Enfermedades de los Perros/genética , Perros , Electrorretinografía/métodos , Electrorretinografía/veterinaria , Masculino , Retina/fisiología , Enfermedades de la Retina/veterinaria , Tomografía de Coherencia Óptica/veterinaria
3.
Doc Ophthalmol ; 144(2): 81-97, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35247111

RESUMEN

PURPOSE: In this study, we assessed several extended electroretinographic protocols using nonstandard stimuli. Our aim was to separate and quantify the contributions of different populations of retinal cells to the overall response, both to assess normal function and characterize dogs with inherited retinal disease. METHODS: We investigated three different protocols for measuring the full-field flash electroretinogram-(1) chromatic dark-adapted red and blue flashes, (2) increasing luminance blue-background, (3) flicker with fixed frequency and increasing luminance, and flicker with increasing frequency at a fixed luminance-to assess rod and cone contributions to electroretinograms recorded in phenotypically normal control dogs and dogs lacking rod function. RESULTS: Temporal separation of the rod- and cone-driven responses is possible in the fully dark-adapted eye using dim red flashes. A- and b-wave amplitudes decrease at different rates with increasing background luminance in control dogs. Flicker responses elicited with extended flicker protocols are well fit with mathematical models in control dogs. Dogs lacking rod function demonstrated larger amplitude dark-adapted compared to light-adapted flicker responses. CONCLUSIONS: Using extended protocols of the full-field electroretinogram provides additional characterization of the health and function of different populations of cells in the normal retina and enables quantifiable comparison between phenotypically normal dogs and those with retinal disease.


Asunto(s)
Electrorretinografía , Enfermedades de la Retina , Animales , Adaptación a la Oscuridad , Perros , Electrorretinografía/métodos , Estimulación Luminosa , Células Fotorreceptoras Retinianas Conos/fisiología
4.
Doc Ophthalmol ; 143(2): 171-184, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33818677

RESUMEN

PURPOSE: To analyze ERG responses from two dog models of retinitis pigmentosa, one due to a PDE6A mutation and the other a CNGB1 mutation, both to assess the effect of these mutations on retinal function and the ability of gene augmentation therapy to restore normal function. METHODS: Scotopic and photopic ERGs from young affected and normal control dogs and affected dogs following AAV-mediated gene augmentation therapy were analyzed. Parameters reflecting rod and cone function were collected by modeling the descending slope of the a-wave to measure receptor response and sensitivity. Rod-driven responses were further assessed by Naka-Rushton fitting of the first limb of the scotopic b-wave luminance-response plot. RESULTS: PDE6A-/- dogs showed a dramatic decrease in rod-driven responses with very reduced rod maximal responses and sensitivity. There was a minor reduction in the amplitude of maximal cone responses. In contrast, CNGB1-/- dogs had some residual rod responses with reduced amplitude and sensitivity and normal cone responses. Following gene augmentation therapy, rod parameters were substantially improved in both models with restoration of sensitivity parameters log S and log K and a large increase in log Rmax in keeping with rescue of normal rod phototransduction in the treated retinal regions. CONCLUSIONS: Modeling of rod and cone a-waves and the luminance-response function of the scotopic b-wave characterized the loss of rod photoreceptor function in two dog models of retinitis pigmentosa and showed the effectiveness of gene augmentation therapy in restoring normal functional parameters.


Asunto(s)
Visión de Colores , Retinitis Pigmentosa , Animales , Perros , Electrorretinografía , Retina , Células Fotorreceptoras Retinianas Conos , Retinitis Pigmentosa/genética , Retinitis Pigmentosa/terapia
5.
BMC Vet Res ; 16(1): 225, 2020 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-32605619

RESUMEN

BACKGROUND: Retinal diseases are common in dogs. Some hereditary retinal dystrophies in dogs are important not only because they lead to vision loss but also because they show strong similarities to the orthologous human conditions. Advances in in vivo non-invasive retinal imaging allow the capture of retinal cross-section images that parallel low power microscopic examination of histological sections. Spectral domain - optical coherence tomography (SD-OCT) allows the measurement of retinal layer thicknesses and gives the opportunity for repeat examination to investigate changes in thicknesses in health (such as changes with maturation and age) and disease (following the course of retinal degenerative conditions). The purpose of this study was to use SD-OCT to measure retinal layer thicknesses in the dog during retinal maturation and over the first year of life. SD-OCT was performed on normal beagle cross dogs from 4 weeks of age to 52 weeks of age. To assess changes in layer thickness with age, measurements were taken from fixed regions in each of the 4 quadrants and the area centralis (the region important for most detailed vision). Additionally, changes in retinal layer thickness along vertical and horizontal planes passing through the optic nerve head were assessed. RESULTS: In the four quadrants an initial thinning of retinal layers occurred over the first 12 to 15 weeks of life after which there was little change in thickness. However, in the area centralis there was a thickening of the photoreceptor layer over this time period which was mostly due to a lengthening of the photoreceptor inner/outer segment layer. The retina thinned with greater distances from the optic nerve head in both vertical and horizontal planes with the dorsal retina being thicker than the ventral retina. Most of the change in thickness with distance from the optic nerve head was due to difference in thickness of the inner retinal layers. The outer retinal layers remained more constant in thickness, particularly in the horizontal plane and dorsal to the optic nerve head. CONCLUSIONS: These measurements will provide normative data for future studies.


Asunto(s)
Perros/anatomía & histología , Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/veterinaria , Animales , Femenino , Masculino , Retina/crecimiento & desarrollo , Tomografía de Coherencia Óptica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...