1.
Rev Sci Instrum ; 93(8): 081101, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-36050050

RESUMEN

Giant negative ion sources for neutral beam injectors deliver huge negative ion currents, thanks to their multi-beamlet configuration. As the single-beamlet optics defines the transmission losses along the beamline, the extraction of a similar current for all beamlets is extremely desirable, in order to facilitate the beam source operation (i.e., around perveance match). This Review investigates the correlation between the vertical profile of beam intensity and the vertical profiles of plasma properties at the extraction region of the source, focusing on the influence of increasing cesium injection. Only by the combined use of all available source diagnostics, described in this Review, can beam features on the scale of the non-uniformities be investigated with a sufficient space resolution. At RF power of 50 kW/driver, with intermediate bias currents and a filter field of 2.4 mT, it is found that the central part of the four vertical beam segments exhibits comparable plasma density and beamlet currents; at the edges of the central segments, both the beam and electron density appear to decrease (probably maintaining fixed electron-to-ion ratio); at the bottom of the source, an increase of cesium injection can compensate for the vertical drifts that cause a much higher presence of electrons and a lower amount of negative ions.

2.
Rev Sci Instrum ; 92(7): 073001, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34340429

RESUMEN

A novel method for the path combination of two lasers with very similar wavelengths has been implemented to enable the evaluation of a dual-laser calibration Thomson scattering (TS) technique. The first experimental test of this TS technique has been performed in a RFX-mod plasma device, where, due to experimental constraints, the combination of a Nd:YAG (λ = 1064 nm) and a Nd:YLF (λ = 1053 nm) laser system was the only viable choice available. The method requires that the beam path of both lasers be combined into a single path with the same polarization. This presents a unique challenge due to the small difference between the two laser wavelengths. In this paper, we describe two methods for beam combination: first via a prism, eventually dismissed as unpractical, and second via a polarizing beam splitter in reverse with a dual-wavelength waveplate. We detail the optical setup, waveplate design, and successful implementation of this second method.

3.
Rev Sci Instrum ; 92(4): 043556, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243487

RESUMEN

An incoherent Thomson scattering diagnostic will be installed in the JT-60SA tokamak to measure electron temperature and electron density profiles. The target radial spatial resolution is 25 mm with 46 spatial channels. The accuracy in electron temperature and density is a few percent at ne = 7.5 × 1019 m-3, which is the expected value in the plasma core. This paper presents the designs of collection optics, fibers with their alignment system, and polychromators. The collection optics overcomes unique issues for superconducting fusion devices, i.e., limited design space, high-temperature measurements, and harsh radiation condition. When in several years the more performing plasma will generate intense nuclear radiation, the lens materials of the optics can be replaced by radiation resistant glasses without major changes in the lens holder. It will prevent transmission degradation and keep stable measurement accuracy.

4.
Rev Sci Instrum ; 92(5): 053507, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243229

RESUMEN

The neutral beam injectors of the ITER experiment will rely on negative ion sources to produce 16.7 MW beams of H/D particles accelerated at 1 MeV. The prototype of these sources was built and is currently operated in the SPIDER (Source for the Production of Ions of Deuterium Extracted from a Radio frequency plasma) experiment, part of the Neutral Beam Test Facility of Consorzio RFX, Padua. In the SPIDER, the H-/D- ion source is coupled to a three grid, 100 kV acceleration system. One of the main goals of the experimentation in SPIDER is to uniformly maximize the extracted current density; to achieve this, it is important to study the density of negative ions available in the proximity of the ion acceleration system. In SPIDER, line-integrated measurements of negative ion density are performed by a cavity ring down spectroscopy diagnostic. Its principle of operation is based on the absorption of the photons of a laser beam pulse by H-/D- photo-detachment; the absorption detection is enhanced by trapping the laser pulse in an optical cavity, containing the absorbing medium (i.e., negative ions). This paper presents and discusses the CRDS diagnostic setup in the SPIDER, including the first measurements of negative ion density, correlated with the main source parameters.

5.
Rev Sci Instrum ; 92(4): 043302, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243389

RESUMEN

Beam tomography is a non-invasive diagnostic that allows us to reconstruct the beam emission profile by measuring the light emitted by the beam particles interacting with the background gas, along an elevated number of lines of sight, which is related to the beam density by assuming a uniform background gas. In the framework of the heating and current drive of future nuclear fusion reactors, negative ion beams of hydrogen and deuterium are required for neutral beam injectors (NBIs) due to their elevated neutralization efficiency at high energy (in the MeV range). Beside the beam energy, beam divergence and homogeneity are two critical aspects in the design of future NBIs. In this paper, the characterization of the negative ion beam of the negative ion source NIO1 (a small-sized radio-frequency driven negative ion source, with 130 mA of total extracted H- current and 60 kV of maximum acceleration) using the tomographic system composed of two visible cameras is presented. The Simultaneous Algebraic Reconstruction Technique (SART) is used as an inversion technique to reconstruct the 3 × 3 matrix of the extracted beamlets, and the beam divergence and homogeneity are studied. The results are compared with the measurements of the other diagnostics and correlated with the source physics. The suitability of visible cameras as a diagnostics system for the characterization of the NIO1 negative ion beam is a small-scale experimental demonstration of the possibility to reconstruct more complicated multi-beamlet profiles, resulting in a powerful diagnostic for large NBIs.

6.
Rev Sci Instrum ; 91(2): 023510, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32113382

RESUMEN

The requirements of ITER neutral beam injectors (1 MeV, 40 A negative deuterium ion current for 1 h) have never been simultaneously attained; therefore, a dedicated Neutral Beam Test Facility (NBTF) was set up at Consorzio RFX (Padova, Italy). The NBTF includes two experiments: SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma), the full-scale prototype of the source of ITER injectors, with a 100 keV accelerator, to investigate and optimize the properties of the ion source; and MITICA, the full-scale prototype of the entire injector, devoted to the issues related to the accelerator, including voltage holding at low gas pressure. The present paper gives an account of the status of the procurements, of the timeline, and of the voltage holding tests and experiments for MITICA. As for SPIDER, the first year of operation is described, regarding the solution of some issues connected with the radiofrequency power, the source operation, and the characterization of the first negative ion beam.

7.
Rev Sci Instrum ; 89(10): 103504, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399701

RESUMEN

Cavity Ring Down Spectroscopy (CRDS) is used to measure the D- absolute density produced in the helicon plasma reactor RAID (Resonant Antenna Ion Device) at the Swiss Plasma Center. The birdcage geometry of the helicon antenna produces a homogeneous, high-density plasma column (n e ≅ 1.5 × 1018 m-3 in H2 and D2 at 0.3 Pa and 3 kW of input power) 1.4 m long. We present the CRDS experimental setup, its positioning on the RAID reactor, and how the mechanical and thermal effects of the plasma affect the measurement. First results in deuterium plasma confirm the production of negative ions (D-) with a significant density: an average value of 3.0 × 1016 m-3 of D- is obtained at 0.3 Pa and 5 kW of power input in Cs-free plasma. This result is in good agreement with calculations performed with the collisional radiative code YACORA.

8.
Rev Sci Instrum ; 89(10): 10J111, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399762

RESUMEN

Injection of high energy neutral beam particles will be used in the ITER experiment for plasma heating and current drive. In a ITER heating beam injector, a 40 MW electrostatically accelerated negative beam will be neutralised and filtered along the beamline, obtaining a nominal 16.5 MW neutral beam power to be injected in the tokamak plasma or intercepted during conditioning and commissioning. The beam will heat the actively cooled panels of the beamline components with up to 13 MW/m2 surface power density and 18 MW power. These extreme conditions require testing in a ITER full scale neutral beam test facility under construction in Padova where the temperature of the beamline components will be monitored by 610 embedded thermocouples for protection against critical conditions, for recognising beam conditioning, and for deriving beam parameters. Power density maps of the expected beam-component interactions are applied on a parametric non-linear finite element model to simulate fields of expected temperatures. Such thermal maps are analyzed to derive the beam parameters during operation: divergence of 3-7 mrad and misalignment of 0-3 mrad. The sensibility of the temperature measurements is discussed considering a minimum 10% fraction of the nominal beam power.

9.
Rev Sci Instrum ; 89(10): 10I139, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399769

RESUMEN

Along the route to the development of a neutral beam injector for ITER, the Padua based Source for Production of Ion of Deuterium Extracted from Rf plasma (SPIDER) and megavolt ITER injector and concept advancement facilities will make use of neutron diagnostics to quantify the homogeneity of the neutral beam profile by measuring the map of the neutron emission from the beam dump with the close-contact neutron emission surface mapping (CNESM) system. Neutrons are here produced from beam-target reactions between the deuterium beam and the deuterons previously adsorbed in the calorimeter. In order to aid the interpretation of the diagnostic data, a dedicated experiment on neutron emission from beam-target reactions with beam parameters approaching those expected at SPIDER has been performed at the Extraction from a Large Ion Source Experiment (ELISE) neutral beam test facility. The time trace of neutron emission has been measured using a calibrated liquid scintillator detector at increasing power densities on the target. Compared to calculations based on the local mixing model, a systematic discrepancy was observed exceeding the statistical accuracy of the measurements and increasing as a linear function of the power density. The data are used to derive an empirical temperature dependent correction for applications to neutron measurements at SPIDER.

10.
Rev Sci Instrum ; 87(11): 11D417, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910334

RESUMEN

Embedded sensors have been designed for installation on the components of the MITICA beamline, the prototype ITER neutral beam injector (Megavolt ITER Injector and Concept Advancement), to derive characteristics of the particle beam and to monitor the component conditions during operation for protection and thermal control. Along the beamline, the components interacting with the particle beam are the neutralizer, the residual ion dump, and the calorimeter. The design and the positioning of sensors on each component have been developed considering the expected beam-surface interaction including non-ideal and off-normal conditions. The arrangement of the following instrumentation is presented: thermal sensors, strain gages, electrostatic probes including secondary emission detectors, grounding shunt for electrical currents, and accelerometers.

11.
Rev Sci Instrum ; 87(11): 11D438, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910602

RESUMEN

In high power neutral beams for fusion, beam uniformity is an important figure of merit. Knowing the transverse power profile is essential during the initial phases of beam source operation, such as those expected for the ITER heating neutral beam (HNB) test facility. To measure it a diagnostic technique is proposed, based on the collection of secondary electrons generated by beam-surface and beam-gas interactions, by an array of positively biased collectors placed behind the calorimeter tubes. This measurement showed in the IREK test stand good proportionality to the primary beam current. To investigate the diagnostic performances in different conditions, we developed a numerical model of secondary electron emission, induced by beam particle impact on the copper tubes, and reproducing the cascade of secondary emission caused by successive electron impacts. The model is first validated against IREK measurements. It is then applied to the HNB case, to assess the locality of the measurement, the proportionality to the beam current density, and the influence of beam plasma.

12.
Rev Sci Instrum ; 87(11): 11D433, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910628

RESUMEN

The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H- production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

13.
Rev Sci Instrum ; 87(11): 11D415, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910661

RESUMEN

The beam power produced by the negative ion source for the production of ion of deuterium extracted from RF plasma is mainly absorbed by the beam dump component which has been designed also for measuring the temperatures on the dumping panels for beam diagnostics. A finite element code has been developed to characterize, by thermo-hydraulic analysis, the sensitivity of the beam dump to the different beam parameters. The results prove the capability of diagnosing the beam divergence and the horizontal misalignment, while the entity of the halo fraction appears hardly detectable without considering the other foreseen diagnostics like tomography and beam emission spectroscopy.

14.
Rev Sci Instrum ; 87(2): 02B309, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932037

RESUMEN

The megavolt ITER injector and concept advancement experiment is the prototype and the test bed of the ITER heating and current drive neutral beam injectors, currently in the final design phase, in view of the installation in Padova Research on Injector Megavolt Accelerated facility in Padova, Italy. The beam source is the key component of the system, as its goal is the generation of the 1 MeV accelerated beam of deuterium or hydrogen negative ions. This paper presents the highlights of the latest developments for the finalization of the MITICA beam source design, together with a description of the most recent analyses and R&D activities carried out in support of the design.

15.
Rev Sci Instrum ; 87(2): 02B318, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932046

RESUMEN

The neutralization efficiency of negative ion neutral beam injectors is a major issue for future fusion reactors. Photon neutralization might be a valid alternative to present gas neutralizers, but still with several challenges for a valid implementation. Some concepts have been presented so far but none has been validated yet. A novel photoneutralization concept is discussed here, based on an annular cavity and a duplicated frequency laser beam (recirculation injection by nonlinear gating). The choice of lithium triborate as the material for the second harmonic extractor is discussed and a possible cooling method via crystal slicing is presented; laser intensity enhancement within the cavity is evaluated in order to quantify the achievable neutralization rate. Mockups of the critical components are proposed as intermediate steps toward system realization.

16.
Rev Sci Instrum ; 87(2): 02B319, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932047

RESUMEN

NIO1 (Negative Ion Optimization 1) is a compact and flexible radio frequency H(-) ion source, developed by Consorzio RFX and INFN-LNL. The aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances, an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study, respectively, the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular, the sudden increase of the light emitted from the plasma above a certain power threshold.

17.
Rev Sci Instrum ; 87(2): 02B320, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932048

RESUMEN

Neutral Beam Injectors (NBIs), which need to be strongly optimized in the perspective of DEMO reactor, request a thorough understanding of the negative ion source used and of the multi-beamlet optics. A relatively compact radio frequency (rf) ion source, named NIO1 (Negative Ion Optimization 1), with 9 beam apertures for a total H(-) current of 130 mA, 60 kV acceleration voltage, was installed at Consorzio RFX, including a high voltage deck and an X-ray shield, to provide a test bench for source optimizations for activities in support to the ITER NBI test facility. NIO1 status and plasma experiments both with air and with hydrogen as filling gas are described. Transition from a weak plasma to an inductively coupled plasma is clearly evident for the former gas and may be triggered by rising the rf power (over 0.5 kW) at low pressure (equal or below 2 Pa). Transition in hydrogen plasma requires more rf power (over 1.5 kW).

18.
Rev Sci Instrum ; 87(2): 02B925, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932097

RESUMEN

This paper presents the results of numerical simulations and experimental tests carried out to assess the feasibility and suitability of graphite castellated tiles as beam-facing component in the diagnostic calorimeter of the negative ion source SPIDER (Source for Production of Ions of Deuterium Extracted from Radio frequency plasma). The results indicate that this concept could be a reliable, although less performing, alternative for the present design based on carbon fiber composite tiles, as it provides thermal measurements on the required spatial scale.

19.
Rev Sci Instrum ; 87(2): 02B927, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932099

RESUMEN

In view of the realization of the negative ion beam injectors for ITER, a test facility, named SPIDER, is under construction in Padova (Italy) to study and optimize production and extraction of negative ions. The present paper is devoted to the analysis of the expected first operations of SPIDER in terms of single-beamlet and multiple-beamlet simulations of the hydrogen beam optics in various operational conditions. The effectiveness of the methods adopted to compensate for the magnetic deflection of the particles is also assessed. Indications for a sequence of the experimental activities are obtained.

20.
Rev Sci Instrum ; 87(2): 02B931, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932103

RESUMEN

Megavolt ITER Injector and Concept Advancement, the full-scale prototype of ITER neutral beam injector, is under construction in Italy. The device will generate deuterium negative ions, then accelerated and neutralized. The emerging beam, after removal of residual ions, will be dumped onto a calorimeter. The presence of plasma and its parameters will be monitored in the components of the beam-line, by means of specific electrostatic probes. Double probes, with the possibility to be configured as Langmuir probes and provide local ion density and electron temperature measurements, will be employed in the neutralizer and in the residual ion dump. Biased electrodes collecting secondary emission electrons will be installed in the calorimeter with the aim to provide a horizontal profile of the beam.