Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
Arq. bras. oftalmol ; 86(4): 314-321, July-Sep. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1447380

RESUMEN

ABSTRACT Purpose: To compare strip meniscometry and Schirmer tear test 1 results and tear film breakup time between dogs with normal eyes and dogs diagnosed with keratoconjunctivitis sicca. Methods: One-hundred fifty-six eyes of 78 dogs, 88 normal eyes, and 68 eyes diagnosed with keratoconjunctivitis sicca were included in the study. The tests were performed in the following sequence: Schirmer tear test 1 was used to allocate the dogs to the normal or keratoconjunctivitis sicca group, followed by the strip meniscometry test and tear film breakup time measurement. Results: The results (mean ± standard deviation) of the tests in the normal group were as follows: Schirmer tear test 1, 22.75 ± 3.88 mm/min; strip meniscometry test, 10.01 ± 2.35 mm/5 sec; and tear film breakup time, 25.82 ± 5.47 sec. In the keratoconjunctivitis sicca group, the results were as follows: Schirmer tear test 1, 6.10 ± 4.44 mm/min; strip meniscometry test, 3.03 ± 2.62 mm/5 sec; and tear film breakup time, 10.78 ± 4.23 sec. The Spearman correlation coefficient in the keratoconjunctivitis sicca group was very high, with a significant difference between the strip meniscometry test and Schirmer tear test 1 (r=0.848, p<0.001), and moderate and significant between the strip meniscometry test and tear film breakup time (r=0.773, p<0.001). The cutoff for the strip meniscometry test for keratoconjunctivitis sicca was 7.0 mm/5 sec. Keratoconjunctivitis sicca was suspected when the values were <10 mm/5 sec. Conclusions: This study provided strip meniscometry test values from dogs with normal eyes and eyes with keratoconjunctivitis sicca, with high sensitivity and specificity compared with those of the Schirmer tear test 1. In the future, the strip meniscometry test may be another important quantitative test and could complement the gold standard Schirmer tear test for the diagnosis of keratoconjunctivitis sicca in dogs, an excellent animal model for the study of the disease.


RESUMO Objetivo: Comparar o teste de meniscometria em tira com o teste lacrimal de Schirmer 1 e o tempo de ruptura do filme lacrimal, em cães com olhos normais e cães com diagnóstico de ceratoconjuntivite seca. Métodos: Cento e cinquenta e seis olhos de 78 cães, 88 olhos normais e 68 olhos com diagnóstico de ceratoconjuntivite seca. Os testes foram realizados na seguinte sequência: o teste lacrimal de Schirmer 1 foi utilizado para alocar os cães no grupo normal ou no grupo ceratoconjuntivite seca, seguido pelo teste de meniscometria em tira e tempo de ruptura do filme lacrimal. Resultados: As médias e desvios-padrão para os olhos normais foram: teste lacrimal de Schirmer 1 = 22,75 ± 3,88 mm / min; teste de meniscometria em tira = 10,01 ± 2,35 mm / 5 seg; tempo de ruptura do filme lacrimal = 25,82 ± 5,47 seg; e para os olhos do grupo ceratoconjuntivite seca foram: teste lacrimal de Schirmer 1 = 6,10 ± 4,44 mm / min; teste de meniscometria em tira = 3,03 ± 2,62 mm / 5 seg; tempo de ruptura do filme lacrimal = 10,78 ± 4,23 seg. O teste de correlação de Spearman no grupo ceratoconjuntivite seca foi muito alto, com diferença significativa entre teste de meniscometria em tira e teste lacrimal de Schirmer 1 (r=0,848, p<0,001), moderada e significativa entre teste de meniscometria em tira e tempo de ruptura do filme lacrimal (r=0,773, p<0,001). O cut-off para teste de meniscometria em tira para ceratoconjuntivite seca foi identificado em 7,0 mm / 5 seg, valores abaixo de 10 mm / 5 seg podem ser considerados suspeitos para KCS. Conclusões: Este estudo forneceu valores de teste de meniscometria em tira em olhos normais e com ceratoconjuntivite seca em cães, revelando alta sensibilidade e especificidade em comparação com o teste lacrimal de Schirmer 1. No futuro, o teste de meniscometria em tira pode ser outro teste quantitativo importante e pode complementar o teste lacrimal de Schirmer padrão ouro para o diagnóstico de ceratoconjuntivite seca em cães, um excelente modelo animal para o estudo de ceratoconjuntivite seca.

2.
Vet World ; 16(1): 134-143, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36855346

RESUMEN

Background and Aim: Keratoconjunctivitis sicca (KCS) is predominantly an immune-mediated chronic inflammatory ocular disease that is commonly diagnosed in dogs. This study aimed to compare the conventional use of topical immunosuppressant tacrolimus 0.03% eye drops and a new therapy injectable homologous platelet-rich plasma (HPRP) into the third eyelid gland and inferior and superior palpebral conjunctiva of dogs with KCS. Materials and Methods: A total of 66 eyes from 33 dogs were evaluated. The eyes were divided into three equal groups: Negative control group, tacrolimus group (TG), and homologous platelet-rich plasma group (HPRPG). The animals were evaluated using the Schirmer's tear test-1 (STT-1), osmolarity test (OT), strip meniscometry test (SMT), tear film break-up test (TBUT), fluorescein test, lissamine green test (LGT), and cytological and histopathological analyses. Results: In TG, there was a significant increase (p < 0.05) in the STT-1 and SMT values, and goblet cell count in the palpebral conjunctiva by the end of the study. In HPRPG, 36% (four dogs) received three applications, 55% (six dogs) received two applications, and 9% (one dog) received one application before the initial ocular signs improved. There was a significant decrease (p < 0.05) in the lymphocyte and neutrophil counts of the palpebral conjunctiva in HPRPG than in TG. Both groups showed equivalent improvements in TBUT, OT, and LGT values. Conclusion: Tacrolimus 0.03% eye drops were more efficient than HPRP in increasing tear production and the number of goblet cells. However, injectable HPRP was more efficient than tacrolimus in decreasing the number of conjunctival inflammatory cells. Treatment with injectable HPRP requires an average of two to three applications, is safe and feasible, and can be used as a cheaper alternative or as an adjuvant to conventional treatment with topical immunosuppressants.

3.
Arq Bras Oftalmol ; 86(4): 314-321, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35544927

RESUMEN

PURPOSE: To compare strip meniscometry and Schirmer tear test 1 results and tear film breakup time between dogs with normal eyes and dogs diagnosed with keratoconjunctivitis sicca. Methods: One-hundred fifty-six eyes of 78 dogs, 88 normal eyes, and 68 eyes diagnosed with keratoconjunctivitis sicca were included in the study. The tests were performed in the following sequence: Schirmer tear test 1 was used to allocate the dogs to the normal or keratoconjunctivitis sicca group, followed by the strip meniscometry test and tear film breakup time measurement. RESULTS: The results (mean ± standard deviation) of the tests in the normal group were as follows: Schirmer tear test 1, 22.75 ± 3.88 mm/min; strip meniscometry test, 10.01 ± 2.35 mm/5 sec; and tear film breakup time, 25.82 ± 5.47 sec. In the keratoconjunctivitis sicca group, the results were as follows: Schirmer tear test 1, 6.10 ± 4.44 mm/min; strip meniscometry test, 3.03 ± 2.62 mm/5 sec; and tear film breakup time, 10.78 ± 4.23 sec. The Spearman correlation coefficient in the keratoconjunctivitis sicca group was very high, with a significant difference between the strip meniscometry test and Schirmer tear test 1 (r=0.848, p<0.001), and moderate and significant between the strip meniscometry test and tear film breakup time (r=0.773, p<0.001). The cutoff for the strip meniscometry test for keratoconjunctivitis sicca was 7.0 mm/5 sec. Keratoconjunctivitis sicca was suspected when the values were <10 mm/5 sec. CONCLUSIONS: This study provided strip meniscometry test values from dogs with normal eyes and eyes with keratoconjunctivitis sicca, with high sensitivity and specificity compared with those of the Schirmer tear test 1. In the future, the strip meniscometry test may be another important quantitative test and could complement the gold standard Schirmer tear test for the diagnosis of keratoconjunctivitis sicca in dogs, an excellent animal model for the study of the disease.

4.
Vet World ; 14(9): 2444-2451, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34840465

RESUMEN

BACKGROUND AND AIM: Tonometers are an important instrument for measuring intraocular pressure (IOP) in the diagnosis of glaucoma or uveitis. This study aimed to compare the accuracy of the main types of tonometers with different IOP measurement methodologies in dogs: TonoVet and TonoVet Plus (rebound), Tono-Pen Avia Vet (applanation), and Kowa HA-2 (Goldmann applanation). MATERIALS AND METHODS: IOP was measured in 152 eyes of 76 dogs. A postmortem study was performed by comparing manometry and tonometry values and calculating the correlation coefficient (r2), in vivo real IOP (manometry) among the tonometers was compared, and an outpatient study was conducted with healthy eyes and eyes with signs of glaucoma and uveitis. RESULTS: In the postmortem study, the values of r2 in descending order were Kowa (0.989), TonoVet Plus (0.984), TonoVet (0.981), and Tono-Pen Avia Vet (0.847). The IOP values in mmHg in the in vivo study were as follows: Aneroid manometer (16.8±2.5.7), TonoVet (18.1±2.9), TonoVet Plus (20.6±2.3), Tono-Pen Avia Vet (17.1±2.5), and Kowa (16.1±1.7); in outpatient clinics: TonoVet (16.8±3.8), TonoVet Plus (19.2±2.9), Tono-Pen Avia Vet (16.2±2.4), and Kowa (15.0±1.3); glaucoma: TonoVet (30.2±3.5), TonoVet Plus (35.0±6.1), Tono-Pen Avia Vet (29.5±4.2), and Kowa (23.9±5.0); and uveitis: TonoVet (14.2±1.4), TonoVet Plus (17.6±1.9), Tono-Pen Avia Vet (13.7±2.1), and Kowa (12.6±1.7). CONCLUSION: There was a strong correlation between IOP values and manometry in all the tonometers. The highest values were obtained with TonoVet Plus and the lowest with Kowa HA-2. All tonometers accurately measured IOP in dogs, including the latest TonoVet Plus, which showed an excellent correlation coefficient.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...