1.
J. optom. (Internet) ; 16(4): 252-260, October - December 2023. tab, graf
Artículo en Inglés | IBECS | ID: ibc-225614

RESUMEN

Purpose: To assess the agreement between the Eye Refract, an instrument to perform subjective automated refraction, and the traditional subjective refraction, as the gold standard, in young hyperopes under noncycloplegic and cycloplegic conditions. Methods: A cross-section and randomized study was carried out, involving 42 participants (18.2 ± 7.7 years, range 6 to 31 years). Only one eye was chosen for the analysis, randomly. An optometrist conducted the refraction with the Eye Refract, while another different optometrist conducted the traditional subjective refraction. Spherical equivalent (M), cylindrical components (J0 and J45), and corrected distance visual acuity (CDVA) were compared between both refraction methods under noncycloplegic and cycloplegic conditions. A Bland-Altman analysis was performed to assess the agreement (accuracy and precision) between both refraction methods. Results: Without cycloplegia, the Eye Refract showed significantly lower values of hyperopia than the traditional subjective refraction (p < 0.009), the mean difference (accuracy) and its 95% limits of agreement (precision) being -0.31 (+0.85, -1.47) D. Conversely, there were no statistical differences between both refraction methods under cycloplegic conditions (p ≥ 0.05). Regarding J0 and J45, both refraction methods manifested no significant differences between them under noncycloplegic and cycloplegic conditions (p ≥ 0.05). Finally, the Eye Refract significantly improved CDVA (0.04 ± 0.01 logMAR) compared with the traditional subjective refraction without cycloplegia (p = 0.01). Conclusions: The Eye Refract is presented as a useful instrument to determine the refractive error in young hyperopes, the use of cycloplegia being necessary to obtain accurate and precise spherical refraction. (AU)


Asunto(s)
Niño , Adolescente , Adulto Joven , Adulto , Midriáticos , Refracción Ocular/efectos de los fármacos , Hiperopía , Optometristas
2.
J Optom ; 16(4): 252-260, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37019707

RESUMEN

PURPOSE: To assess the agreement between the Eye Refract, an instrument to perform subjective automated refraction, and the traditional subjective refraction, as the gold standard, in young hyperopes under noncycloplegic and cycloplegic conditions. METHODS: A cross-section and randomized study was carried out, involving 42 participants (18.2 ± 7.7 years, range 6 to 31 years). Only one eye was chosen for the analysis, randomly. An optometrist conducted the refraction with the Eye Refract, while another different optometrist conducted the traditional subjective refraction. Spherical equivalent (M), cylindrical components (J0 and J45), and corrected distance visual acuity (CDVA) were compared between both refraction methods under noncycloplegic and cycloplegic conditions. A Bland-Altman analysis was performed to assess the agreement (accuracy and precision) between both refraction methods. RESULTS: Without cycloplegia, the Eye Refract showed significantly lower values of hyperopia than the traditional subjective refraction (p < 0.009), the mean difference (accuracy) and its 95% limits of agreement (precision) being -0.31 (+0.85, -1.47) D. Conversely, there were no statistical differences between both refraction methods under cycloplegic conditions (p ≥ 0.05). Regarding J0 and J45, both refraction methods manifested no significant differences between them under noncycloplegic and cycloplegic conditions (p ≥ 0.05). Finally, the Eye Refract significantly improved CDVA (0.04 ± 0.01 logMAR) compared with the traditional subjective refraction without cycloplegia (p = 0.01). CONCLUSIONS: The Eye Refract is presented as a useful instrument to determine the refractive error in young hyperopes, the use of cycloplegia being necessary to obtain accurate and precise spherical refraction.


Asunto(s)
Hiperopía , Presbiopía , Errores de Refracción , Humanos , Midriáticos , Pruebas de Visión , Refracción Ocular , Errores de Refracción/diagnóstico
3.
Biomedicines ; 11(2)2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36830827

RESUMEN

The eye is a metabolically active structure, constantly exposed to solar radiations making its structure vulnerable to the high burden of reactive oxygen species (ROS), presenting many molecular interactions. The biomolecular cascade modification is caused especially in diseases of the ocular surface, cornea, conjunctiva, uvea, and lens. In fact, the injury in the anterior segment of the eye takes its origin from the perturbation of the pro-oxidant/antioxidant balance and leads to increased oxidative damage, especially when the first line of antioxidant defence weakens with age. Furthermore, oxidative stress is related to mitochondrial dysfunction, DNA damage, lipid peroxidation, protein modification, apoptosis, and inflammation, which are involved in anterior ocular disease progression such as dry eye, keratoconus, uveitis, and cataract. The different pathologies are interconnected through various mechanisms such as inflammation, oxidative stress making the diagnostics more relevant in early stages. The end point of the molecular pathway is the release of different antioxidant biomarkers offering the potential of predictive diagnostics of the pathology. In this review, we have analysed the oxidative stress and inflammatory processes in the front of the eye to provide a better understanding of the pathomechanism, the importance of biomarkers for the diagnosis of eye diseases, and the recent treatment of anterior ocular diseases.

4.
Eye Contact Lens ; 49(3): 120-126, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36700614

RESUMEN

PURPOSE: To evaluate the effect of the topical instillation of hyaluronic acid eye drops with different viscosity on soft contact lens wettability and comfort. METHODS: A randomized and participant-masked study was performed, involving 20 participants (25.4±2.6 years). One eye wore hydrogel (ocufilcon D) contact lenses, and another eye wore silicone-hydrogel (somofilcon A) contact lenses. The in vivo wettability tear film surface quality (TFSQ) index and comfort were measured before and after the instillation of different eye drops: saline solution (control) and 0.1%, 0.2%, and 0.3% hyaluronic acid. RESULTS: Compared with saline solution, the instillation of 0.1%, 0.2%, and 0.3% hyaluronic acid improved the in vivo wettability of the hydrogel contact lenses by decreasing their TFSQ mean for 5, 10, and 30 min, respectively ( P <0.05). During silicone-hydrogel contact lens wear, the hyaluronic acid did not affect wettability because there were no changes in TFSQ mean ( P ≥0.05), but the 0.3% hyaluronic acid produced a decrease in comfort for the first 3 min ( P <0.05). CONCLUSIONS: The instillation of hyaluronic acid eye drops increased the in vivo wettability of the hydrogel contact lens, and the duration of this effect was directly related to its concentration and viscosity.


Asunto(s)
Lentes de Contacto Hidrofílicos , Ácido Hialurónico , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Hidrogeles , Soluciones Oftálmicas , Solución Salina , Siliconas , Humectabilidad
5.
Int J Mol Sci ; 23(23)2022 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-36499204

RESUMEN

Acanthamoeba keratitis is an aggressive and rapidly progressing ocular pathology whose main risk factor is the use of contact lenses. An early and differential diagnosis is considered the main factor to prevent the progression and improve the prognosis of the pathology. However, current diagnosis techniques require time, complex and costly materials making an early diagnosis challenging. Thus, there is a need for fast, accessible, and accurate methods for Acanthamoeba detection by practitioners for timely and suitable treatment and even for contact lens user as preventive diagnosis. Here, we developed a dual-mode colorimetric-based method for fast, visual, and accurate detection of Acanthamoeba using gold nanoparticles (AuNPs). For this strategy, AuNPs were functionalized with thiolated probes and the presence of target Acanthamoeba genomic sequences, produce a colorimetric change from red to purple. This approach allows the detection of 0.02 and 0.009 µM of the unamplified Acanthamoeba genome by the naked eye in less than 20 min and by color analysis using a smartphone. Additionally, real samples were successfully analyzed showing the potential of the technology considering the lack of point-of-care tools that are mostly needed.


Asunto(s)
Queratitis por Acanthamoeba , Acanthamoeba , Nanopartículas del Metal , Humanos , Oro , Queratitis por Acanthamoeba/diagnóstico , Queratitis por Acanthamoeba/etiología , Diagnóstico Precoz
6.
Cont Lens Anterior Eye ; 45(4): 101498, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34373201

RESUMEN

PURPOSE: To evaluate comfort, visual function, and in vivo wettability after the insertion of hydrogel and silicone hydrogel contact lenses for a better understanding of how long practitioners should wait for the initial evaluation of soft contact lenses. METHODS: A short-term prospective, contralateral, randomized, and participant-masked study was carried out. Twenty healthy participants (25.4 ± 2.6 years) were evaluated after the insertion of two different soft contact lenses at different times (1, 5, 10, 20, 30 min). Ocufilcon D (hydrogel) and Somofilcon A (silicone hydrogel) contact lenses were randomly assigned to both eyes of the same participant. Comfort, visual function under photopic conditions in terms of high-contrast visual acuity, low-contrast visual acuity, contrast sensitivity, and in vivo wettability were measured. RESULTS: There was an increase in comfort (p < 0.001), high-contrast visual acuity (p < 0.05), and contrast sensitivity (p < 0.001, only with silicone hydrogel) directly related to time after contact lens insertion. Besides, in vivo wettability suffered a statistically significant deterioration directly related to time with both contact lenses (p < 0.05). Except for comfort and contrast sensitivity, all the parameters stabilized their values 10 min after the insertion of both soft contact lenses. Additionally, in vivo wettability and visual acuity differences were found between hydrogel and silicone hydrogel contact lenses (p < 0.05). CONCLUSIONS: It would be possible to properly evaluate high-contrast visual acuity, low-contrast visual acuity, and in vivo wettability 10 min after the insertion of both soft contact lenses.


Asunto(s)
Lentes de Contacto Hidrofílicos , Hidrogel de Polietilenoglicol-Dimetacrilato , Humanos , Hidrogeles , Satisfacción del Paciente , Estudios Prospectivos , Siliconas
7.
Pharmaceutics ; 13(9)2021 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-34575451

RESUMEN

Most irreversible blindness observed with glaucoma and retina-related ocular diseases, including age-related macular degeneration and diabetic retinopathy, have their origin in the posterior segment of the eye, making their physiopathology both complex and interconnected. In addition to the age factor, these diseases share the same mechanism disorder based essentially on oxidative stress. In this context, the imbalance between the production of reactive oxygen species (ROS) mainly by mitochondria and their elimination by protective mechanisms leads to chronic inflammation. Oxidative stress and inflammation share a close pathophysiological process, appearing simultaneously and suggesting a relationship between both mechanisms. The biochemical end point of these two biological alarming systems is the release of different biomarkers that can be used in the diagnosis. Furthermore, oxidative stress, initiating in the vulnerable tissue of the posterior segment, is closely related to mitochondrial dysfunction, apoptosis, autophagy dysfunction, and inflammation, which are involved in each disease progression. In this review, we have analyzed (1) the oxidative stress and inflammatory processes in the back of the eye, (2) the importance of biomarkers, detected in systemic or ocular fluids, for the diagnosis of eye diseases based on recent studies, and (3) the treatment of posterior ocular diseases, based on long-term clinical studies.

8.
Optom Vis Sci ; 98(6): 597-604, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34081650

RESUMEN

SIGNIFICANCE: The performance of the Eye Refract (Luneau Technology, Chartres, France), a new instrument to perform aberrometry-based automated subjective refraction, has been previously evaluated in healthy subjects. However, its clinical implications in other ocular conditions are still unknown. PURPOSE: The purpose of this study was to evaluate the agreement between the Eye Refract and the traditional subjective refraction, as the criterion standard, in keratoconus patients with and without intracorneal ring segments (ICRSs). METHODS: A total of 50 eyes of 50 keratoconus patients were evaluated, dividing the sample into 2 groups: 27 eyes without ICRS (37.78 ± 9.35 years) and 23 eyes with ICRS (39.26 ± 13.62 years). An optometrist conducted the refraction with the Eye Refract, and another different optometrist conducted the traditional subjective refraction on the same day. Spherical equivalent (M), cylindrical vectors (J0 and J45), and corrected distance visual acuity were compared between both methods of refraction. In addition, Bland-Altman analysis was performed to assess the agreement between both methods of refraction. RESULTS: There were no statistically significant differences (P ≥ .05) between the Eye Refract and the traditional subjective refraction for all the variables under study in either group. Without ICRS, the mean difference and 95% limits of agreement (upper, lower) were -0.20 (+1.50, -1.89) D for M, -0.14 (+1.40, -1.68) D for J0, and +0.05 (+1.23, -1.14) D for J45. With ICRS, these values worsened to -0.62 (+3.89, -5.12) D for M, +0.06 (+2.46, -2.34) D for J0, and -0.02 (+2.23, -2.28) D for J45. CONCLUSIONS: The Eye Refract seems to offer similar results compared with the traditional subjective refraction in keratoconus patients not implanted with ICRS. However, some patients could show abnormal measurements, especially those with ICRS, who should be treated with caution in clinical practice.


Asunto(s)
Queratocono , Aberrometría , Sustancia Propia/cirugía , Topografía de la Córnea , Humanos , Queratocono/diagnóstico , Queratocono/cirugía , Prótesis e Implantes , Implantación de Prótesis , Refracción Ocular , Pruebas de Visión
9.
Cont Lens Anterior Eye ; 44(6): 101471, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34049809

RESUMEN

PURPOSE: To evaluate the changes in visual function and anterior surface aberrations during soft contact lens (SCL) wear after the instillation of hyaluronic acid (HA) eye drops with different viscosity. METHODS: A prospective, randomized, and participant-masked study was performed. Twenty healthy participants (25.4 ± 2.6 years) were evaluated. Hydrogel (Ocufilcon D) and silicone-hydrogel (Somofilcon A) SCL were randomly assigned to both eyes of the same participant. Visual function in terms of high- and low-contrast corrected distance visual acuity (CDVA) and anterior contact lens surface aberrations (RMS HOA) were measured before and after the instillation, at different times, of different eye drops: saline (control) and 0.1%, 0.2%, and 0.3% HA. RESULTS: Compared with the saline solution, during hydrogel SCL wear, there was an improvement (P < 0.05) in high-contrast CDVA after 3 and 10 min with 0.1% HA, and after 5 and 20 min with 0.2% HA. During silicone-hydrogel SCL wear, there was a deterioration (P < 0.05) in high-contrast CDVA after 1 and 30 min with 0.3% HA. Additionally, during silicone-hydrogel SCL wear, there was also a deterioration (P < 0.05) in low-contrast CDVA after 5 and 20 min with 0.3% HA. In terms of RMS HOA, there were no clinically relevant changes with both SCL. CONCLUSIONS: The instillation of HA eye drops could have a different effect on visual quality depending on their concentration of HA, the contact lens material, its surface ionicity, or other physicochemical properties that should be studied in future studies.


Asunto(s)
Lentes de Contacto Hidrofílicos , Ácido Hialurónico , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Soluciones Oftálmicas , Estudios Prospectivos , Agudeza Visual
10.
Biomolecules ; 11(3)2021 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-33668357

RESUMEN

Circadian rhythm and the molecules involved in it, such as melanopsin and melatonin, play an important role in the eye to regulate the homeostasis and even to treat some ocular conditions. As a result, many ocular pathologies like dry eye, corneal wound healing, cataracts, myopia, retinal diseases, and glaucoma are affected by this cycle. This review will summarize the current scientific literature about the influence of circadian patterns on the eye, focusing on its relationship with increased intraocular pressure (IOP) fluctuations and glaucoma. Regarding treatments, two ways should be studied: the first one, to analyze if some treatments could improve their effect on the ocular disease when their posology is established in function of circadian patterns, and the second one, to evaluate new drugs to treat eye pathologies related to the circadian rhythm, as it has been stated with melatonin or its analogs, that not only could be used as the main treatment but as coadjutant, improving the circadian pattern or its antioxidant and antiangiogenic properties.


Asunto(s)
Ritmo Circadiano/fisiología , Glaucoma/fisiopatología , Animales , Síndromes de Ojo Seco/fisiopatología , Glaucoma/metabolismo , Humanos , Presión Intraocular/fisiología , Melatonina/metabolismo , Miopía/metabolismo , Miopía/fisiopatología
11.
J Ophthalmol ; 2020: 7204951, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32566267

RESUMEN

PURPOSE: To optimize a rabbit dry eye model induced by topical instillation of benzalkonium chloride (BAC), reduce the days of instillation of the original model by increasing the concentration of BAC from 0.1% to 0.2%. MATERIALS AND METHODS: An experimental, prospective, and randomized study was performed on 10 male New Zealand white rabbits, divided into two groups, considering both eyes: 5 rabbits as control (n = 10) and 5 rabbits with 0.2% BAC treatment (n = 10). Saline solution (control) and 0.2% BAC were instilled for 5 consecutive days, twice daily. Tear secretion with and without anesthesia, tear breakup time, tear osmolarity, corneal staining, conjunctival hyperemia, density of goblet cells, height of mucin cloud, and transcript levels of IL-6 were measured before and after the treatment. RESULTS: After the instillation of 0.2% BAC for 5 consecutive days, there was a significant increase in tear secretion without anesthesia (P < 0.001), corneal staining (P < 0.001), conjunctival hyperemia (P < 0.001), and levels of IL-6 mRNA (P=0.005) compared to the control group. Conversely, there was a decrease in tear secretion with anesthesia (P < 0.001), tear breakup time (P=0.007), tear osmolarity (P < 0.001), density of goblet cells (P < 0.001), and height of mucin cloud (P < 0.001). CONCLUSIONS: The topical instillation of 0.2% BAC for 5 consecutive days, twice daily, was a proper procedure to induce a rabbit dry eye model, reducing the number of days of instillation compared to the original model (14 days).

12.
J Ophthalmol ; 2020: 4831298, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33489331

RESUMEN

PURPOSE: To compare the intersession repeatability of the Eye Refract, a new instrument to perform aberrometry-based automated subjective refraction, on healthy and keratoconus subjects. MATERIALS AND METHODS: A cross-sectional and randomized study was performed. A total of 64 participants were evaluated in the study, selecting one eye per participant randomly. The sample was divided into two different groups: 33 healthy subjects (38.85 ± 13.21 years) and 31 with keratoconus (37.29 ± 11.37 years). Three refractions per participant with the Eye Refract were performed on three different days, without cycloplegia. The repeatability analysis of refractive variables (M, J0, and J45), binocular corrected distance visual acuity (BCDVA), and spent time in refraction was performed in terms of repeatability (S r), its 95% confidence interval (r), and intraclass correlation coefficient (ICC). RESULTS: There were no statistically significant differences (P ≥ 0.05) between sessions in both groups for all refractive variables (M, J0, and J45) and BCDVA. Spent time in refraction was reduced as the sessions went by (P < 0.05). The Eye Refract was more repeatable for refractive errors assessment in healthy subjects (M : S r = 0.27 D; J0 : S r = 0.09 D; J45 : S r = 0.06 D) compared to those with keratoconus (M : S r = 0.65 D; J0 : S r = 0.29 D; J45 : S r = 0.24 D), while it was similar for BCDVA. CONCLUSIONS: The Eye Refract offered better repeatability to assess refractive errors in healthy subjects compared to those with keratoconus. Despite measurements being also consistent in keratoconus subjects, they should be treated with caution in clinical practice.

13.
Acta Ophthalmol ; 97(2): e162-e169, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30280515

RESUMEN

PURPOSE: To evaluate changes in tear meniscus dynamics using optical coherence tomography (OCT) after the instillation of different concentrations of sodium hyaluronate (SH) ophthalmic solutions. METHODS: An experimental, double-masked, randomized study was performed. Twenty-three healthy subjects (16 women and seven men; mean age 23.57 ± 2.56 years) participated in this study. About 35 µl of 0.1%, 0.2%, 0.3% SH ophthalmic solutions and saline solution was instilled in a randomly assigned eye. Tear meniscus measurements (height, depth and turbidity) were taken with OCT at 30 seconds and 1, 3, 5, 10 and 20 min after instillation. Subsequently, the Schirmer test and tear break-up time (TBUT) were evaluated. RESULTS: Tear meniscus depth and tear meniscus height showed a significant increase with all solutions compared to basal values: up to 3 min for 0.1% SH, up to 5 min for 0.2% and up to 10 min for 0.3% SH ophthalmic solution. Tear meniscus turbidity was also increased at 30 seconds for 0.1%, 0.2% and 0.3% SH artificial tears (p < 0.05). This increase remained significant for up to 1 min for 0.2% and 0.3% SH solutions (p < 0.05). After 5 min of saline and 0.1% SH instillation, the turbidity was lower than basal values (p < 0.05). There was a significant increase in the TBUT for all solutions after instillation (p < 0.05). No differences between the Schirmer pre- and postinstillation were found (p > 0.05). Finally, the comfort was significantly improved for all ophthalmic solutions (p < 0.05). CONCLUSION: Sodium hyaluronate (SH) ophthalmic solutions increase residence time in healthy subjects and are positively correlated with its concentration and therefore the viscosity.


Asunto(s)
Síndromes de Ojo Seco/tratamiento farmacológico , Ácido Hialurónico/administración & dosificación , Lágrimas/química , Tomografía de Coherencia Óptica/métodos , Método Doble Ciego , Síndromes de Ojo Seco/diagnóstico , Femenino , Voluntarios Sanos , Humanos , Instilación de Medicamentos , Masculino , Soluciones Oftálmicas , Propiedades de Superficie , Viscosuplementos/administración & dosificación , Adulto Joven
SELECCIÓN DE REFERENCIAS