Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomimetics (Basel) ; 9(1)2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38248592

RESUMEN

Engineering artificial mechanosensory hair cells offers a promising avenue for developing diverse biosensors spanning applications from biomedicine to underwater sensing. Unfortunately, current artificial sensory hair cells do not have the ability to simultaneously achieve ultrahigh sensitivity with low-frequency threshold detection (e.g., 0.1 Hz). This work aimed to solve this gap by developing an artificial sensory hair cell inspired by the vestibular sensory apparatus, which has such functional capabilities. For device characterization and response testing, the sensory unit was inserted in a 3D printed lateral semicircular canal (LSCC) mimicking the environment of the labyrinth. The sensor was fabricated based on platinum (Pt) thin film which was reinforced by carbon nanofibers (CNFs). A Pi-shaped hair cell sensor was created as the sensing element which was tested under various conditions of simulated head motion. Results reveal the hair cell sensor displayed markedly higher sensitivity compared to other reported artificial hair cell sensors (e.g., 21.47 mV Hz-1 at 60°) and low frequency detection capability, 0.1 Hz < f < 1.5 Hz. Moreover, like the LSCC hair cells in biology, the fabricated sensor was most sensitive in a given plane of rotational motion, demonstrating features of directional sensitivity.

2.
Audiol Res ; 13(6): 910-928, 2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-37987337

RESUMEN

Both auditory and vestibular primary afferent neurons can be activated by sound and vibration. This review relates the differences between them to the different receptor/synaptic mechanisms of the two systems, as shown by indicators of peripheral function-cochlear and vestibular compound action potentials (cCAPs and vCAPs)-to click stimulation as recorded in animal studies. Sound- and vibration-sensitive type 1 receptors at the striola of the utricular macula are enveloped by the unique calyx afferent ending, which has three modes of synaptic transmission. Glutamate is the transmitter for both cochlear and vestibular primary afferents; however, blocking glutamate transmission has very little effect on vCAPs but greatly reduces cCAPs. We suggest that the ultrafast non-quantal synaptic mechanism called resistive coupling is the cause of the short latency vestibular afferent responses and related results-failure of transmitter blockade, masking, and temporal precision. This "ultrafast" non-quantal transmission is effectively electrical coupling that is dependent on the membrane potentials of the calyx and the type 1 receptor. The major clinical implication is that decreasing stimulus rise time increases vCAP response, corresponding to the increased VEMP response in human subjects. Short rise times are optimal in human clinical VEMP testing, whereas long rise times are mandatory for audiometric threshold testing.

3.
J Neurosci ; 43(43): 7149-7157, 2023 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-37775302

RESUMEN

Amniotes evolved a unique postsynaptic terminal in the inner ear vestibular organs called the calyx that receives both quantal and nonquantal (NQ) synaptic inputs from Type I sensory hair cells. The nonquantal synaptic current includes an ultrafast component that has been hypothesized to underlie the exceptionally high synchronization index (vector strength) of vestibular afferent neurons in response to sound and vibration. Here, we present three lines of evidence supporting the hypothesis that nonquantal transmission is responsible for synchronized vestibular action potentials of short latency in the guinea pig utricle of either sex. First, synchronized vestibular nerve responses are unchanged after administration of the AMPA receptor antagonist CNQX, while auditory nerve responses are completely abolished. Second, stimulus evoked vestibular nerve compound action potentials (vCAP) are shown to occur without measurable synaptic delay and three times shorter than the latency of auditory nerve compound action potentials (cCAP), relative to the generation of extracellular receptor potentials. Third, paired-pulse stimuli designed to deplete the readily releasable pool (RRP) of synaptic vesicles in hair cells reveal forward masking in guinea pig auditory cCAPs, but a complete lack of forward masking in vestibular vCAPs. Results support the conclusion that the fast component of nonquantal transmission at calyceal synapses is indefatigable and responsible for ultrafast responses of vestibular organs evoked by transient stimuli.SIGNIFICANCE STATEMENT The mammalian vestibular system drives some of the fastest reflex pathways in the nervous system, ensuring stable gaze and postural control for locomotion on land. To achieve this, terrestrial amniotes evolved a large, unique calyx afferent terminal which completely envelopes one or more presynaptic vestibular hair cells, which transmits mechanosensory signals mediated by quantal and nonquantal (NQ) synaptic transmission. We present several lines of evidence in the guinea pig which reveals the most sensitive vestibular afferents are remarkably fast, much faster than their auditory nerve counterparts. Here, we present neurophysiological and pharmacological evidence that demonstrates this vestibular speed advantage arises from ultrafast NQ electrical synaptic transmission from Type I hair cells to their calyx partners.


Asunto(s)
Células Ciliadas Vestibulares , Vestíbulo del Laberinto , Animales , Cobayas , Potenciales de Acción/fisiología , Células Ciliadas Vestibulares/fisiología , Transmisión Sináptica/fisiología , Sinapsis/fisiología , Mamíferos
4.
Sci Rep ; 13(1): 10204, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37353559

RESUMEN

To examine mechanisms responsible for vestibular afferent sensitivity to transient bone conducted vibration, we performed simultaneous measurements of stimulus-evoked vestibular compound action potentials (vCAPs), utricular macula velocity, and vestibular microphonics (VMs) in anaesthetized guinea pigs. Results provide new insights into the kinematic variables of transient motion responsible for triggering mammalian vCAPs, revealing synchronized vestibular afferent responses are not universally sensitive to linear jerk as previously thought. For short duration stimuli (< 1 ms), the vCAP increases magnitude in close proportion to macular velocity and temporal bone (linear) acceleration, rather than other kinematic elements. For longer duration stimuli, the vCAP magnitude switches from temporal bone acceleration sensitive to linear jerk sensitive while maintaining macular velocity sensitivity. Frequency tuning curves evoked by tone-burst stimuli show vCAPs increase in proportion to onset macular velocity, while VMs increase in proportion to macular displacement across the entire frequency bandwidth tested between 0.1 and 2 kHz. The subset of vestibular afferent neurons responsible for synchronized firing and vCAPs have been shown previously to make calyceal synaptic contacts with type I hair cells in the striolar region of the epithelium and have irregularly spaced inter-spike intervals at rest. Present results provide new insight into mechanical and neural mechanisms underlying synchronized action potentials in these sensitive afferents, with clinical relevance for understanding the activation and tuning of neurons responsible for driving rapid compensatory reflex responses.


Asunto(s)
Conducción Ósea , Vestíbulo del Laberinto , Animales , Cobayas , Conducción Ósea/fisiología , Potenciales de Acción , Vestíbulo del Laberinto/fisiología , Vibración , Neuronas Aferentes/fisiología , Mamíferos
5.
Front Neurol ; 14: 1109506, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37051057

RESUMEN

Introduction: Calyx bearing vestibular afferent neurons innervating type I hair cells in the striolar region of the utricle are exquisitely sensitive to auditory-frequency air conducted sound (ACS) and bone conducted vibration (BCV). Here, we present experimental data and a mathematical model of utricular mechanics and vestibular compound action potential generation (vCAP) in response to clinically relevant levels of ACS and BCV. Vibration of the otoconial layer relative to the sensory epithelium was simulated using a Newtonian two-degree-of-freedom spring-mass-damper system, action potential timing was simulated using an empirical model, and vCAPs were simulated by convolving responses of the population of sensitive neurons with an empirical extracellular voltage kernel. The model was validated by comparison to macular vibration and vCAPs recorded in the guinea pig, in vivo. Results: Transient stimuli evoked short-latency vCAPs that scaled in magnitude and timing with hair bundle mechanical shear rate for both ACS and BCV. For pulse BCV stimuli with durations <0.8 ms, the vCAP magnitude increased in proportion to temporal bone acceleration, but for pulse durations >0.9 ms the magnitude increased in proportion to temporal bone jerk. Once validated using ACS and BCV data, the model was applied to predict blast-induced hair bundle shear, with results predicting acute mechanical damage to bundles immediately upon exposure. Discussion: Results demonstrate the switch from linear acceleration to linear jerk as the adequate stimulus arises entirely from mechanical factors controlling the dynamics of sensory hair bundle deflection. The model describes the switch in terms of the mechanical natural frequencies of vibration, which vary between species based on morphology and mechanical factors.

6.
Audiol Res ; 12(5): 457-465, 2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-36136853

RESUMEN

As previously reported, a single test measuring oVEMP n10 to 4000 Hz stimuli (bone-conducted vibration (BCV) or air-conducted sound (ACS)) provides a definitive diagnosis of semicircular canal dehiscence (SCD) in 22 CT-verified patients, with a sensitivity of 1.0 and specificity of 1.0. This single short screening test has great advantages of speed, minimizing testing time, and the exposure of patients to stimulation. However, a few studies of the 4000 Hz test for SCD have reported sensitivity and specificity values which are slightly less than reported previously. We hypothesized that the rise time of the stimulus is important for detecting the oVEMP n10 to 4000 Hz, similarly to what we had shown for 500 and 750 Hz BCV. We measured oVEMP n10 in 15 patients with CT-verified SCD in response to 4000 Hz ACS or BCV stimuli with rise times of 0, 1, and 2 ms. As a result, increasing the rise time of the stimulus reduced the oVEMP n10 amplitude. This outcome is expected from the physiological evidence of guinea pig primary vestibular afferents, which are activated by sound or vibration. Therefore, for clinical VEMP testing, short rise times are optimal (preferably 0 ms).

7.
J R Soc Interface ; 18(185): 20210753, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34875876

RESUMEN

Monitoring human respiratory patterns is of great importance as it gives essential information for various medical conditions, e.g. sleep apnoea syndrome and chronic obstructive pulmonary disease and asthma, etc. Herein, we have developed a polymeric airflow sensor based on nanocomposites of vertically grown graphene nanosheets (VGNs) with polydimethylsiloxane (PDMS) and explored their applications in monitoring human respiration. The sensing performance of the VGNs/PDMS nanocomposite was characterized by exposing to a range of airflow rates (20-130 l min-1), and a linear performance with high sensitivity and low response time (mostly below 1 s) was observed. To evaluate the experimental results, finite-element simulation models were developed in the COMSOL Multiphysics package. The piezoresistive properties of VGNs/PDMS thin film and fluid-solid interaction were thoroughly studied. Laser Doppler vibrometry measures of sensor tip displacement closely approximated simulated deflection results and validated the dynamic response of the sensor. By comparing the proposed sensor and some other airflow sensors in the literature, it is concluded that the VGNs/PDMS airflow sensor has excellent features in terms of sensor height, detection range and sensitivity. The potential application of the VGNs/PDMS airflow sensor in detecting the respiration pattern of human exercises like walking, jogging and running has been demonstrated.


Asunto(s)
Grafito , Nanocompuestos , Dispositivos Electrónicos Vestibles , Humanos , Monitoreo Fisiológico
8.
ACS Appl Mater Interfaces ; 13(37): 44904-44915, 2021 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-34516096

RESUMEN

With an ageing population, hearing disorders are predicted to rise considerably in the following decades. Thus, developing a new class of artificial auditory system has been highlighted as one of the most exciting research topics for biomedical applications. Herein, a design of a biocompatible piezoresistive-based artificial hair cell sensor is presented consisting of a highly flexible and conductive polyvinyl alcohol (PVA) nanocomposite with vertical graphene nanosheets (VGNs). The bilayer hydrogel sensor demonstrates excellent performance to mimic biological hair cells, responding to acoustic stimuli in the audible range between 60 Hz to 20 kHz. The sensor output demonstrates stable mid-frequency regions (∼4-9 kHz), with the greatest sensitivity as high frequencies (∼13-20 kHz). This is somewhat akin to the mammalian auditory system, which has remarkable sensitivity and sharp tuning at high frequencies due to the "active process". This work validates the PVA/VGN sensor as a potential candidate to play a similar functional role to that of the cochlear hair cells, which also operate over a wide frequency domain in a viscous environment. Further characterizations of the sensor show that increasing the sound amplitude results in higher responses from the sensor while taking it to the depth drops the sensor outputs due to attenuation of sound in water. Meanwhile, the acoustic pressure distribution of sound waves is predicted through finite element analysis, whereby the numerical results are in perfect agreement with experimental data. This proof-of-concept work creates a platform for the future design of susceptible, flexible biomimetic sensors to closely mimic the biological cochlea.


Asunto(s)
Materiales Biomiméticos/química , Hidrogeles/química , Nanocompuestos/química , Biomimética/métodos , Conductividad Eléctrica , Grafito/química , Células Ciliadas Auditivas/química , Alcohol Polivinílico/química , Prueba de Estudio Conceptual , Sonido
9.
J Neurosci Res ; 99(11): 3066-3083, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34510506

RESUMEN

Galvanic vestibular stimulation (GVS) has been shown to improve vestibular function potentially via stochastic resonance, however, it remains unknown how central vestibular nuclei process these signals. In vivo work applying electrical stimuli to the vestibular apparatus of animals has shown changes in neuronal discharge at the level of the primary vestibular afferents and hair cells. This study aimed to determine the cellular impacts of stochastic, sinusoidal, and stochastic + sinusoidal stimuli on individual medial vestibular nucleus (MVN) neurons of male and female C57BL/6 mice. All stimuli increased the irregularity of MVN neuronal discharge, while differentially affecting neuronal gain. This suggests that the heterogeneous MVN neuronal population (marked by differential expression of ion channels), may influence the impact of electrical stimuli on neuronal discharge. Neuronal subtypes showed increased variability of neuronal firing, where Type A and B neurons experienced the largest gain changes in response to stochastic and sinusoidal stimuli. Type C neurons were the least affected regarding neuronal firing variability and gain changes. The membrane potential (MP) of neurons was altered by sinusoidal and stochastic + sinusoidal stimuli, with Type B and C neuronal MP significantly affected. These results indicate that GVS-like electrical stimuli impact MVN neuronal discharge differentially, likely as a result of heterogeneous ion channel expression.


Asunto(s)
Neuronas , Núcleos Vestibulares , Animales , Femenino , Masculino , Potenciales de la Membrana , Ratones , Ratones Endogámicos C57BL , Neuronas/fisiología
10.
Front Neurosci ; 15: 695179, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34456671

RESUMEN

The evoked response to repeated brief stimuli, such as clicks or short tone bursts, is used for clinical evaluation of the function of both the auditory and vestibular systems. One auditory response is a neural potential - the Auditory Brainstem Response (ABR) - recorded by surface electrodes on the head. The clinical analogue for testing the otolithic response to abrupt sounds and vibration is the myogenic potential recorded from tensed muscles - the vestibular evoked myogenic potential (VEMP). VEMPs have provided clinicians with a long sought-after tool - a simple, clinically realistic indicator of the function of each of the 4 otolithic sensory regions. We review the basic neural evidence for VEMPs and discuss the similarities and differences between otolithic and cochlear receptors and afferents. VEMPs are probably initiated by sound or vibration selectively activating afferent neurons with irregular resting discharge originating from the unique type I receptors at a specialized region of the otolithic maculae (the striola). We review how changes in VEMP responses indicate the functional state of peripheral vestibular function and the likely transduction mechanisms allowing otolithic receptors and afferents to trigger such very short latency responses. In section "ELECTROPHYSIOLOGY" we show how cochlear and vestibular receptors and afferents have many similar electrophysiological characteristics [e.g., both generate microphonics, summating potentials, and compound action potentials (the vestibular evoked potential, VsEP)]. Recent electrophysiological evidence shows that the hydrodynamic changes in the labyrinth caused by increased fluid volume (endolymphatic hydrops), change the responses of utricular receptors and afferents in a way which mimics the changes in vestibular function attributed to endolymphatic hydrops in human patients. In section "MECHANICS OF OTOLITHS IN VEMPS TESTING" we show how the major VEMP results (latency and frequency response) follow from modeling the physical characteristics of the macula (dimensions, stiffness etc.). In particular, the structure and mechanical operation of the utricular macula explains the very fast response of the type I receptors and irregular afferents which is the very basis of VEMPs and these structural changes of the macula in Menière's Disease (MD) predict the upward shift of VEMP tuning in these patients.

11.
Hear Res ; 406: 108259, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34038828

RESUMEN

The Summating Potential (SP) was first recorded in the cochlea in the 1950s and represents an objective measure of cochlear hair cell function, in vivo. Despite being a regular tool in hearing research, a similar response has not yet been recorded from the vestibular system. This is mainly due to the lack of experimental techniques available to record electrical vestibular hair cell responses in isolation from the much larger cochlear potentials. Here we demonstrate the first recordings of the vestibular SP, evoked by Bone-Conducted Vibration (BCV) and Air-Conducted Sound (ACS) stimuli, in anaesthetized guinea pigs. Field potential measurements were taken from the basal surface of the utricular macula, and from the facial nerve canal following surgical or chemical ablation of the cochlea. SPs were evoked by stimuli with frequencies above ~200 Hz, and only with moderate to high intensity (~0.005-0.05 g) BCV and ACS (~120-140 dB SPL). Neural blockade abolished the Vestibular short-latency Evoked Potential (VsEP) and Vestibular Nerve Neurophonic (VNN) from the facial nerve canal recordings but did not abolish the vestibular SP nor the vestibular microphonic. Importantly, the vestibular SP was irreversibly abolished from the utricle and facial nerve canal recordings following local gentamicin application, highlighting its hair cell origin. This is the first study to record the Summating Potential from the mammalian vestibular system, in vivo, providing a novel research tool to assess vestibular hair cell function during experimental manipulations and animal models of disease.


Asunto(s)
Conducción Ósea , Vestíbulo del Laberinto , Máculas Acústicas , Animales , Modelos Animales de Enfermedad , Cobayas , Sáculo y Utrículo , Sistema Vestibular
12.
J Neurophysiol ; 122(1): 259-276, 2019 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-31042414

RESUMEN

Older studies of mammalian otolith physiology have focused mainly on sustained responses to low-frequency (<50 Hz) or maintained linear acceleration. So the otoliths have been regarded as accelerometers. Thus evidence of otolithic activation and high-precision phase locking to high-frequency sound and vibration appears to be very unusual. However, those results are exactly in accord with a substantial body of knowledge of otolith function in fish and frogs. It is likely that phase locking of otolith afferents to vibration is a general property of all vertebrates. This review examines the literature about the activation and phase locking of single otolithic neurons to air-conducted sound and bone-conducted vibration, in particular the high precision of phase locking shown by mammalian irregular afferents that synapse on striolar type I hair cells by calyx endings. Potassium in the synaptic cleft between the type I hair cell receptor and the calyx afferent ending may be responsible for the tight phase locking of these afferents even at very high discharge rates. Since frogs and fish do not possess full calyx endings, it is unlikely that they show phase locking with such high precision and to such high frequencies as has been found in mammals. The high-frequency responses have been modeled as the otoliths operating in a seismometer mode rather than an accelerometer mode. These high-frequency otolithic responses constitute the neural basis for clinical vestibular-evoked myogenic potential tests of otolith function.


Asunto(s)
Membrana Otolítica/fisiología , Potenciales Vestibulares Miogénicos Evocados , Neuronitis Vestibular/diagnóstico , Animales , Humanos , Mecanotransducción Celular , Membrana Otolítica/fisiopatología , Sonido , Potenciales Sinápticos , Neuronitis Vestibular/fisiopatología , Vibración
13.
Hear Res ; 361: 23-35, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29433062

RESUMEN

In an attempt to view the effects of the efferent vestibular system (EVS) on peripheral dynamic vestibular function, we have monitored the Vestibular short-latency Evoked Potential (VsEP) evoked by pulses of bone conducted vibration during electrical stimulation of the EVS neurons near the floor of the fourth ventricle in the brainstem of anesthetized guinea pigs. Given the reported effects of EVS on primary afferent activity, we hypothesized that EVS stimulation would cause a slight reduction in the VsEP amplitude. Our results show a substantial (>50%) suppression of the VsEP, occurring immediately after a single EVS current pulse. The effect could not be blocked by cholinergic drugs which have been shown to block efferent-mediated vestibular effects. Shocks produced a short-latency P1-N1 response immediately after the electrical artifact which correlated closely to the VsEP suppression. Ultimately, we have identified that this suppression results from antidromic blockade of the afferent response (the VsEP). It would appear that this effect is unavoidable for EVS stimulation, as we found no other effects.


Asunto(s)
Conducción Ósea , Potenciales Evocados , Tiempo de Reacción , Núcleos Vestibulares/fisiología , Estimulación Acústica , Animales , Conducción Ósea/efectos de los fármacos , Estimulación Eléctrica , Potenciales Evocados/efectos de los fármacos , Femenino , Cobayas , Masculino , Inhibición Neural , Neuronas Aferentes/fisiología , Neuronas Eferentes/fisiología , Agonistas Nicotínicos/farmacología , Antagonistas Nicotínicos/farmacología , Tiempo de Reacción/efectos de los fármacos , Factores de Tiempo , Núcleos Vestibulares/efectos de los fármacos
14.
Front Syst Neurosci ; 11: 34, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28620284

RESUMEN

Electrocochleography (EcochG), incorporating the Cochlear Microphonic (CM), the Summating Potential (SP), and the cochlear Compound Action Potential (CAP), has been used to study cochlear function in humans and experimental animals since the 1930s, providing a simple objective tool to assess both hair cell (HC) and nerve sensitivity. The vestibular equivalent of ECochG, termed here Electrovestibulography (EVestG), incorporates responses of the vestibular HCs and nerve. Few research groups have utilized EVestG to study vestibular function. Arguably, this is because stimulating the cochlea in isolation with sound is a trivial matter, whereas stimulating the vestibular system in isolation requires significantly more technical effort. That is, the vestibular system is sensitive to both high-level sound and bone-conducted vibrations, but so is the cochlea, and gross electrical responses of the inner ear to such stimuli can be difficult to interpret. Fortunately, several simple techniques can be employed to isolate vestibular electrical responses. Here, we review the literature underpinning gross vestibular nerve and HC responses, and we discuss the nomenclature used in this field. We also discuss techniques for recording EVestG in experimental animals and humans and highlight how EVestG is furthering our understanding of the vestibular system.

15.
Hear Res ; 339: 112-24, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27377233

RESUMEN

There are a variety of techniques available to investigate endolymph dynamics, primarily seeking to understand the cause of endolymphatic hydrops. Here we have taken the novel approach of injecting, via a glass micropipette, fluorescein isothiocyanate-dextran (FITC-dex) and artificial endolymph into scala media of anaesthetized guinea pigs, with subsequent imaging of the inner ear using Light Sheet Fluorescence Microscopy (LSFM) as a means to obtain highly resolved 3D visualization of fluid movements. Our results demonstrate endolymph movement into the utricle, semicircular canals and endolymphatic duct and sac when more than 2.5 µl of fluid had been injected into scala media, with no apparent movement of fluid into the perilymphatic compartments. There was no movement of endolymph into these compartments when less than 2.5 µl was injected. The remarkable uptake of the FITC-dex into the endolymphatic duct, including an absorption into the periductal channels surrounding the endolymphatic duct, highlights the functional role this structure plays in endolymph volume regulation.


Asunto(s)
Endolinfa/diagnóstico por imagen , Hidropesía Endolinfática/fisiopatología , Microscopía Fluorescente/métodos , Animales , Peso Corporal , Cóclea/fisiopatología , Conducto Coclear , Edema , Endolinfa/fisiología , Hidropesía Endolinfática/diagnóstico por imagen , Femenino , Cobayas , Masculino , Enfermedad de Meniere/fisiopatología , Perilinfa , Sáculo y Utrículo/fisiopatología , Canales Semicirculares/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...