Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artif Organs ; 40(6): 539-48, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26511100

RESUMEN

Thousands of ventricular assist devices (VADs) currently provide circulatory support to patients worldwide, and dozens of heart pump designs for adults and pediatric patients are under various stages of development in preparation for translation to clinical use. The successful bench-to-bedside development of a VAD involves a structured evaluation of possible system states, including human interaction with the device and auxiliary component usage in the hospital or home environment. In this study, we review the literature and present the current landscape of preclinical design and assessment, decision support tools and procedures, and patient-centered therapy. Gaps of knowledge are identified. The study findings support the need for more attention to user-centered design approaches for medical devices, such as mechanical circulatory assist systems, that specifically involve detailed qualitative and quantitative assessments of human-device interaction to mitigate risk and failure.


Asunto(s)
Corazón Auxiliar , Animales , Toma de Decisiones Clínicas/métodos , Aprobación de Recursos , Ergonomía/métodos , Corazón Auxiliar/efectos adversos , Humanos , Medicina de Precisión/métodos , Diseño de Prótesis
2.
J Cardiovasc Transl Res ; 3(6): 600-3, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21046301

RESUMEN

The development of ventricular assist devices (VADs) for the treatment of heart failure has been ongoing since the National Heart Lung and Blood Institute (NHLBI) initiated the artificial heart program in 1964. The primary goal was to develop VADs and total artificial hearts for both temporary (short-term) and long-term use. Due to a small target population and the inability to blind patients and clinicians, the Food and Drug Administration (FDA) has recognized the challenges of conducting trials with these invasive devices. In an effort to address those challenges, FDA has accepted a variety of clinical trial designs to collect the data required to evaluate safety and effectiveness data in different patient groups. This article will provide a detailed discussion of the past, present, and future FDA regulatory considerations for VADs.


Asunto(s)
Aprobación de Recursos/normas , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/normas , United States Food and Drug Administration/normas , Ensayos Clínicos como Asunto , Aprobación de Recursos/legislación & jurisprudencia , Medicina Basada en la Evidencia , Regulación Gubernamental , Corazón Auxiliar/efectos adversos , Humanos , Selección de Paciente , Guías de Práctica Clínica como Asunto , Diseño de Prótesis , Medición de Riesgo , Resultado del Tratamiento , Estados Unidos , United States Food and Drug Administration/legislación & jurisprudencia
3.
J Cardiovasc Transl Res ; 2(2): 143-6, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20559979

RESUMEN

The Food and Drug Administration (FDA) decision process for approving or clearing medical devices is often determined by a review of robust clinical data and extensive preclinical testing of the device. The mission statement for the Center for Devices and Radiological Health (CDRH) is to review the information provided by manufacturers so that it can promote and protect the health of the public by ensuring the safety and effectiveness of medical devices deemed appropriate for human use (Food, Drug & Cosmetic Act, Section 903(b)(1, 2(C)), December 31, 2004; accessed December 17, 2008 http://www.fda.gov/opacom/laws/fdcact/fdctoc.htm). For high-risk devices, such as ventricular assist devices (VADs), mechanical heart valves, stents, cardiac resynchronization therapy (CRT) devices, pacemakers, and defibrillators, the determination is based on FDA's review of extensive preclinical bench and animal testing followed by use of the device in a clinical trial in humans. These clinical trials allow the manufacturer to evaluate a device in the intended use population. FDA reviews the data from the clinical trial to determine if the device performed as predicted and the clinical benefits outweigh the risks. This article reviews the regulatory framework for different marketing applications related to cardiovascular devices and describes the process of obtaining approval to study a cardiovascular device in a U.S. clinical trial.


Asunto(s)
Cardiología/instrumentación , Aprobación de Recursos , Regulación Gubernamental , Política de Salud , Animales , Cardiología/legislación & jurisprudencia , Ensayos Clínicos como Asunto/legislación & jurisprudencia , Seguridad de Productos para el Consumidor/legislación & jurisprudencia , Conducta Cooperativa , Desfibriladores Implantables , Aprobación de Recursos/legislación & jurisprudencia , Diseño de Equipo , Seguridad de Equipos , Medicina Basada en la Evidencia , Guías como Asunto , Prótesis Valvulares Cardíacas , Corazón Auxiliar , Humanos , Comunicación Interdisciplinaria , Marcapaso Artificial , Etiquetado de Productos , Diseño de Prótesis , Medición de Riesgo , Estados Unidos
4.
ASAIO J ; 54(2): 147-9, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18356646

RESUMEN

Dual missions of the Center for Devices and Radiological Health at the Food and Drug Administration (FDA) are 1) promoting public health by promptly reviewing and taking appropriate, timely action regarding the marketing of regulated medical devices while at the same time, and 2) protecting public health by ensuring a reasonable assurance of the safety and effectiveness of medical devices deemed appropriate for human use. In the past, clinicians have used cardiac assist devices intended for adults to treat pediatric heart failure patients. However, because of the larger size of the approved devices, many pediatric patients are underserved by this approach. Currently, several cardiac assist devices intended for use in pediatric patients are being developed. FDA believes that clinical data used to support such safety and probable benefit may be derived from a small focused clinical trial in this target population, and developers may want to consider this approach for approval of the humanitarian device exemption application. Pediatric device development is challenging and early communication with FDA to develop an appropriate regulatory and scientific pathway for device submission is advised and warranted. This early interaction can facilitate the development of a small but necessary trial for these life-sustaining pediatric cardiac assist devices.


Asunto(s)
Aprobación de Recursos , Corazón Auxiliar , United States Food and Drug Administration , Niño , Ensayos Clínicos como Asunto , Humanos , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA