Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am J Perinatol ; 37(7): 754-761, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31121636

RESUMEN

OBJECTIVE: This study aimed to identify and validate the diagnostic utility of a set of clinical and laboratory criteria (early warning criteria [EWC]) that portend a clinical deterioration event (escalated care event [ECE]) in neonatal intensive care unit (NICU) patients. STUDY DESIGN: Using the RAND appropriateness method, we first established a consensus on seven ECE, that is, events that require additional monitoring, treatment, or stay in the NICU or that were associated with morbidity. We then established consensus on EWC that could portend an ECE from an initial set of 32 potential EWC items to a final set of 10 items. The occurrence and nonoccurrence of EWC and ECE were prospectively identified and tracked over 9 weeks. RESULTS: Among 170 NICU patients studied (2,502 patient-days), the frequency of an EWC was 53 per 1,000 patient-days. Of these patients, 41% had an EWC and 16% had an ECE. An EWC was followed by an ECE within 72 hours, 37% of the time, and within a median time interval of 113 minutes. The sensitivity, specificity, positive predictive values, and negative predictive values of EWC in identifying an ECE were 0.96, 0.69, 0.37, and 0.99, respectively. CONCLUSION: A simple bedside NICU-specific EWC identifies neonates likely to develop ECEs in the NICU.


Asunto(s)
Enfermedades del Recién Nacido/diagnóstico , Recién Nacido , Recien Nacido Prematuro , Monitoreo Fisiológico/métodos , Femenino , Humanos , Unidades de Cuidado Intensivo Neonatal , Masculino , Proyectos Piloto , Estudios Prospectivos , Medición de Riesgo/métodos , Sensibilidad y Especificidad
2.
Pediatr Pulmonol ; 54(7): 1039-1044, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30859756

RESUMEN

OBJECTIVE: We sought to evaluate physiological cardiorespiratory implications of high pressures (>8 cmH2 O) on continuous positive airway pressure (CPAP) in preterm neonates. METHODS: Fifteen preterm neonates at postmenstrual age ≥32 weeks on CPAP 5 cmH2 O were enrolled. Pressures were increased by 2 cmH 2 O increments until 13 cmH 2 O. At each increment, cardiac output, electrical diaphragmatic (Edi) activity, and clinical cardiorespiratory parameters were measured. Predefined cut-off values for changes in cardiorespiratory parameters were used as termination criteria. Data, presented as mean (SD), were compared using repeated measures analysis of variance. RESULTS: The mean GA, age at study, and weight of subjects were 27.4 (2.6) weeks, 58.5 (35.5) days, and 2.3 (0.6) kg, respectively. The median (IQR) time at each CPAP increment was 10 (5, 20) min. Cardiac output (mL/kg/min) at 5, 7, 9, 11, and 13 cmH 2 O were not different at 295 (75), 290 (66), 281 (69), 286 (73), and 292 (58), respectively (P = 0.99). Edi values demonstrated a trend towards decline at 9 cmH 2 O before rising again. No other cardiorespiratory parameter was different across CPAP levels; no subject met termination criteria. CONCLUSION: High CPAP levels were well tolerated for short durations. Further physiological and clinical research is required on safety/efficacy in neonates with more severe lung disease, as well as its impact over longer durations.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Gasto Cardíaco , Humanos , Recién Nacido , Presión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...