Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Microsc Res Tech ; 79(7): 567-82, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27219203

RESUMEN

A plethora of optical techniques is currently available to obtain non-destructive, contactless, real time information with subcellular spatial resolution to observe cell processes. Each technique has its own unique features for imaging and for obtaining certain biological information. However none of the available techniques can be of universal use. For a comprehensive investigation of biological specimens and events, one needs to use a combination of bioimaging methods, often at the same time. Some modern confocal/multiphoton microscopes provide simultaneous fluorescence, fluorescence lifetime imaging, and four-dimensional imaging. Some of them can also easily be adapted for harmonic generation imaging, and to permit cell manipulation technique. In this work we present a multimodal optical workstation that extends a commercially available confocal microscope to include nonlinear/multiphoton microscopy and optical manipulation/stimulation tools. The nonlinear microscopy capabilities were added to the commercial confocal microscope by exploiting all the flexibility offered by the manufacturer. The various capabilities of this workstation as applied directly to reproductive biology are discussed. Microsc. Res. Tech. 79:567-582, 2016. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Investigación Biomédica , Microscopía Confocal , Microscopía de Fluorescencia por Excitación Multifotónica , Animales , Histocitoquímica , Humanos , Procesamiento de Imagen Asistido por Computador , Ratones
2.
J Phys Chem B ; 119(11): 4294-9, 2015 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-25692215

RESUMEN

One of the most important properties of quantum dots (QDs) is their size. Their size will determine optical properties and in a colloidal medium their range of interaction. The most common techniques used to measure QD size are transmission electron microscopy (TEM) and X-ray diffraction. However, these techniques demand the sample to be dried and under a vacuum. This way any hydrodynamic information is excluded and the preparation process may alter even the size of the QDs. Fluorescence correlation spectroscopy (FCS) is an optical technique with single molecule sensitivity capable of extracting the hydrodynamic radius (HR) of the QDs. The main drawback of FCS is the blinking phenomenon that alters the correlation function implicating in a QD apparent size smaller than it really is. In this work, we developed a method to exclude blinking of the FCS and measured the HR of colloidal QDs. We compared our results with TEM images, and the HR obtained by FCS is higher than the radius measured by TEM. We attribute this difference to the cap layer of the QD that cannot be seen in the TEM images.


Asunto(s)
Hidrodinámica , Puntos Cuánticos/química , Compuestos de Cadmio/química , Difusión , Tamaño de la Partícula , Espectrometría de Fluorescencia , Telurio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA