Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
2.
Int J Cardiol ; 400: 131701, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38168557

RESUMEN

BACKGROUND: The new balloon-expandable (BE) Myval transcatheter heart valves (THV) has shown promising early results with low paravalvular leak (PVL) and permanent pacemaker implantation (PPI) rates. Limited data are available regarding its long-term performance. We aimed to compare the 2-year clinical and echocardiographic outcomes of transcatheter aortic valve replacement (TAVR) using the self-expanding (SE) Evolut R and the BE Myval THVs. METHODS: The EVAL study included 166 patients with severe aortic valve stenosis who underwent TAVR either with SE Evolut R (n = 108) or BE Myval (n = 58) THV. Primary objectives include comparison on clinical efficacy (freedom from all-cause mortality, stroke, and cardiovascular hospitalization), echocardiographic performance and PPI rates between the two THVs. RESULTS: At 2-year the BE Myval group showed higher clinical efficacy (86% vs. 66%,HR:2.62, 95%CI 2.2-5.1;p = 0.006), with fewer cardiac hospitalizations (3.4% vs. 13.9%,p = 0.03). No significant differences in all-cause mortality, cardiovascular mortality, or stroke rates were observed. The proportion of patients with ≥moderate PVL was significantly lower in the BE Myval compared to the SE Evolut R group (4%vs. 22%,p = 0.008). The mean transvalvular gradient was significantly higher in the SE group compared to the BE group (9.5 ± 4.3 vs. 6.9 ± 2.2 mmHg,p < 0.001), however there was no difference in the percentage of patients with a mean gradient ≥20 mmHg between the two groups. CONCLUSIONS: Both THVs offer similar 2-year clinical outcomes. The BE Myval THV demonstrated advantages with higher clinical efficacy and lower PVL incidence. Longer follow-up and randomized trials are needed to validate these results and assess Myval's sustained performance and durability.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Diseño de Prótesis , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Accidente Cerebrovascular/cirugía
3.
Minerva Cardiol Angiol ; 72(2): 163-171, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37705369

RESUMEN

BACKGROUND: De novo diffuse coronary artery disease (CAD) is a challenging scenario in interventional cardiology with limited treatment option, beside stent implantation. In this context, a hybrid approach, combining the use of drug-eluting stent (DES) and drug-coated balloon (DCB) to treat different segments of the same lesion (e.g. long lesion and/or true bifurcation), might be an interesting and alternative strategy to limit the metal amount. The aim of this study was to evaluate the safety and efficacy of a hybrid approach in addressing percutaneous treatment of de novo diffuse CAD. METHODS: This was a prospective, multicenter study including patients affected by de novo diffuse CAD treated with a hybrid approach from April 2019 to December 2020. Angiographic and clinical data were collected. The primary endpoint was the one-year device-oriented composite endpoint (DOCE, cardiac death, target vessel myocardial infarction and ischemia-driven target lesion revascularization [ID-TLR]). Periprocedural myocardial infarctions and periprocedural success were included among secondary endpoints. RESULTS: One hundred six patients were included, mean age was 68.2±10.2 years and 78.3% were male. De novo diffuse CAD consisted of 52.8% long lesions and 47.2% true bifurcation lesions. Significant increase in the final minimal lumen diameters and significant decrease in the final diameter stenosis were observed when compared to the baseline values in both DES- and DCB-target segments. Procedural success was 96.2%. DOCE at one-year was 3.7%, with all the adverse events characterized by ID-TLR. CONCLUSIONS: Combination of DES and DCB could be a safe and effective treatment option for the treatment of de novo diffuse CAD (NCT03939468).


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Estudios Prospectivos , Angioplastia Coronaria con Balón/efectos adversos
5.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37532153

RESUMEN

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros
6.
Heart ; 110(2): 115-121, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-37316163

RESUMEN

OBJECTIVE: To compare the effects of ticagrelor and prasugrel on absolute coronary blood flow (Q) and microvascular resistance (R) in patients with stable coronary artery disease (CAD) treated with elective percutaneous coronary intervention (PCI) (NCT05643586). Besides being at least as effective as prasugrel in inhibiting platelet aggregation, ticagrelor has been shown to have additional properties potentially affecting coronary microcirculation. METHODS: We randomly assigned 50 patients to ticagrelor (180 mg) or prasugrel (60 mg) at least 12 hours before intervention. Continuous thermodilution was used to measure Q and R before and after PCI. Platelet reactivity was measured before PCI. Troponin I was measured before, 8 and 24 hours after PCI. RESULTS: At baseline, fractional flow reserve, Q and R were similar in two study groups. Patients in the ticagrelor group showed higher post-PCI Q (242±49 vs 205±53 mL/min, p=0.015) and lower R values (311 (263, 366) vs 362 (319, 382) mm Hg/L/min, p=0.032). Platelet reactivity showed a negative correlation with periprocedural variation of Q values (r=-0.582, p<0.001) and a positive correlation with periprocedural variation of R values (r=0.645, p<0.001). The periprocedural increase in high-sensitivity troponin I was significantly lower in the ticagrelor compared with the prasugrel group (5 (4, 9) ng/mL vs 14 (10, 24) ng/mL, p<0.001). CONCLUSIONS: In patients with stable CAD undergoing PCI, pretreatment with a loading dose of ticagrelor compared with prasugrel improves post-procedural coronary flow and microvascular function and seems to reduce the related myocardial injury.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Humanos , Síndrome Coronario Agudo/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Microcirculación , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Inhibidores de Agregación Plaquetaria/farmacología , Clorhidrato de Prasugrel/uso terapéutico , Antagonistas del Receptor Purinérgico P2Y/uso terapéutico , Antagonistas del Receptor Purinérgico P2Y/farmacología , Ticagrelor/uso terapéutico , Resultado del Tratamiento , Troponina I
7.
Eur Heart J Suppl ; 25(Suppl C): C79-C83, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125288

RESUMEN

True coronary bifurcation lesions (CBL) represent a challenging scenario for percutaneous coronary interventions (PCI), and are associated with a higher risk of target lesion failure (TLF), particularly when two stents are implanted. A hybrid strategy combining a drug-eluting stent (DES) in the main branch, and a drug-coated balloon in the side branch may improve outcomes by reducing the total stent length while maintaining an effective anti-prolipherative action. In this sub-study of the HYPER trial, 50 patients with true CBL were treated with a hybrid strategy: procedural success was 96%, one case of peri-procedural myocardial infarction and one case of TLF (in a DES-treated segment) at 1 year were reported. This study suggests that such a hybrid strategy may be a safe and effective option for true CBL PCI, and warrants additional investigations to compare outcomes with standard of care strategies.

9.
Panminerva Med ; 65(1): 1-12, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35546730

RESUMEN

BACKGROUND: Optimal duration of dual antiplatelet therapy (DAPT) following percutaneous coronary intervention (PCI) of a bifurcation stenosis is still debated. We evaluated the impact of DAPT duration on clinical outcomes in all-comers patients undergoing bifurcation PCI included in the European Bifurcation Club (EBC) registry. METHODS: We enrolled 2284 consecutive patients who completed at least 18 months follow-up. The cumulative occurrence of major adverse cardiac and cardiovascular events (MACCE), defined as a composite of overall-death, non-fatal myocardial infarction (MI), target vessel revascularization (TVR) and stroke were evaluated. Bleedings classified as Bleeding Academic Research Consortium (BARC) ≥3 were evaluated too. RESULTS: Patients were divided into 3 groups: short DAPT (<6-months, N.=375); standard DAPT (≥6-months but ≤12-months, N.=636); prolonged DAPT (>12-months, N.=1273). At 24 months follow-up MACCE-free survival was significantly lower in short DAPT patients (Log-Rank: 45.23, P for trend <0.001). MACCE occurred less frequently in the prolonged DAPT group (148 [11.6%]) as compared with both the short (83 [22.1%] HR: 0.48 [0.37-0.63], P<0.001) and standard DAPT groups (137 [21.5%] HR:0.51 [0.41-0.65], P<0.001). These differences remain after propensity score adjustment (respectively, HR: 0.27 [0.20-0.36] and HR: 0.44 [0.34-0.57]). Such finding was consistent in patients presenting with both acute and chronic coronary syndromes. BARC≥3 bleedings were 0.3% in the standard DAPT, 1.6% in short and 1.9% in prolonged DAPT groups. CONCLUSIONS: In the "real-world" EBC registry of patients undergoing PCI of coronary artery bifurcation stenosis, a prolonged DAPT duration was associated with a significantly lower risk of MACCE and a potential increased risk of major bleedings.


Asunto(s)
Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Intervención Coronaria Percutánea/efectos adversos , Constricción Patológica , Resultado del Tratamiento , Hemorragia/inducido químicamente , Hemorragia/tratamiento farmacológico , Sistema de Registros , Quimioterapia Combinada
11.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-35595675

RESUMEN

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Hemodinámica , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
Panminerva med ; 65(1)May. 2022.
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1378104

RESUMEN

BACKGROUND: Optimal duration of Dual Antiplatelet Therapy (DAPT) following percutaneous coronary intervention (PCI) of a bifurcation stenosis is still debated. We evaluated the impact of DAPT duration on clinical outcomes in all-comers patients undergoing bifurcation PCI included in the European Bifurcation Club (EBC) registry. METHODS: We enrolled 2284 consecutive patients who completed at least 18 months follow-up. The cumulative occurrence of Major Adverse Cardiac and Cardiovascular Events (MACCE), defined as a composite of overall-death, non-fatal myocardial infarction (MI), target vessel revascularization (TVR) and stroke were evaluated. Bleedings classified as BARC ≥ 3 were evaluated too. RESULTS: Patients were divided into 3 groups: Short DAPT (<6-months, n=375); Standard DAPT (≥6-months but ≤12-months, n=636); Prolonged DAPT (>12- months, n=1273). At 24 months follow-up MACCE-free survival was significantly lower in Short DAPT patients (Log-Rank: 45.23, p for trend <0.001). MACCE occurred less frequently in the Prolonged DAPT group (148 (11.6%)) as compared with both the Short (83 (22.1%) HR:0.48 (0.37-0.63), p<0.001) and Standard DAPT groups (137 (21.5%) HR:0.51 (0.41-0.65), p<0.001). These differences remain after propensity score adjustment (respectively, HR: 0.27 (0.20-0.36) and HR: 0.44 (0.34-0.57)). Such finding was consistent in patients presenting with both acute and chronic coronary syndromes. BARC ≥ 3 bleedings were 0.3% in the Standard DAPT, 1.6% in Short and 1.9% in Prolonged DAPT groups. CONCLUSIONS: In the "real-world" EBC registry of patients undergoing PCI of coronary artery bifurcation stenosis, a prolonged DAPT duration was associated with a significantly lower risk of MACCE and a potential increased risk of major bleedings.


Asunto(s)
Inhibidores de Agregación Plaquetaria , Intervención Coronaria Percutánea , Duración de la Terapia
13.
J Clin Med ; 11(3)2022 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-35159952

RESUMEN

Over the last 15 years, the management of aortic valve disease has been changed by transcatheter aortic valve replacement, which has become the standard of care across the entire spectrum of surgical risk. As a result of continuous evolution of this technique, several next-generation transcatheter heart valves (THVs) have been developed to minimize procedural complications and improve patient outcomes. This review aims to provide an update on the new generation THVs and delivery systems.

14.
J Clin Med ; 11(4)2022 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-35207232

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective treatment option for patients with severe, symptomatic AS, regardless of the transcatheter heart valve (THV) implanted. Prior studies demonstrated a higher device success with lower paravalvular leak (PVL) using the balloon-expandable (BE) Sapien/XT THV vs. a self-expanding (SE) THV. However, few data are available on the performance of a novel BE THV. PURPOSE: to compare early clinical performance and safety of the newly available BE Myval THV (Myval, Meril Life Sciences Pvt. Ltd., India) vs. the commonly used SE (Evolut R, Medtronic) THV. METHODS:  A single-center, retrospective cohort analysis was performed with 166 consecutive patients undergoing TAVR from March 2019 to March 2021 for severe symptomatic AS treated with either the novel BE Myval or the SE Evolut R (ER) bioprosthesis. The primary endpoint was device success at day 30 according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included 30-day all-cause mortality, cardiovascular mortality, more than mild PVL, permanent pacemaker implantation (PPI) rates and a composite of all-cause mortality and disabling stroke at 6 months. RESULTS:  Among the 166 included patients, 108 patients received the SE ER THV and 58 patients were treated with the BE Myval THV. At baseline, the two groups showed comparable demographic characteristics. The primary composite endpoint of early device success occurred in 55 patients (94.8%) in the BE Myval group and in 90 patients (83.3%) in the SE ER group (OR 3.667, 95% CI 1.094-12.14; p = 0.048). At day 30, the BE Myval THV group exhibited a significantly lower incidence of more than mild PVL (BE Myval 3.45% vs. SE ER 14.8%, OR 0.2, 95% CI 0.05-0.8; p = 0.0338), along with a lower rate of PPI (BE Myval 11% vs. SE ER 24.2%, OR 0.38, 95% CI 0.15-0.99; p = 0.0535). At the 6-month follow-up, the incidence of all-cause mortality and disabling stroke did not significantly differ between the two groups, while the incidence of PPI (BE Myval 11% vs. SE ER 27.5%, OR 0.32, CI 95% 0.1273-0.8; p = 0.02) and ≥moderate PVL (BE Myval 6.9% vs. SE ER 19.8%, OR 0.31, 95% CI 0.1-0.94; p = 0.0396) was significantly lower in the BE Myval group. CONCLUSIONS: In patients with severe symptomatic AS undergoing TAVR, the novel Myval BE THV provided a comparable performance to the well-known ER SE THV, and it was associated with a lower rate of PPI and ≥moderate PVL within 30 days and 6 months after the procedure. Randomized, head-to-head comparison trials are needed to confirm our results.

15.
Rev Cardiovasc Med ; 22(4): 1421-1428, 2021 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-34957782

RESUMEN

Coronary bifurcation lesion (CBL) is a common but challenging scenario in percutaneous coronary interventions. Drug-coated balloons (DCBs) are modern devices with attractive perspective in CBL treatment. In-stent restenosis, small vessel and diffuse de-novo coronary artery disease have been, so far, considered the ideal scenario for DCBs application. Studies assessing DCBs in de-novo CBL demonstrated the safety and efficacy of this strategy. However, the heterogeneity of the study populations and the presence of methodological limitations prevent from drawing definite recommendations. Considering that the best treatment of bifurcations has not yet been defined, the "leaving nothing behind" philosophy will be the topic of future studies.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Intervención Coronaria Percutánea , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 98(3): E351-E355, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33837987

RESUMEN

AIMS: In the randomized GRAFFITI trial, surgeons drew their strategy based on coronary angiography. When patients were randomized to fractional flow reserve (FFR)-guidance, surgeons were informed of the FFR values and asked to redraw their strategy. The aim of this study was to investigate the changes induced by FFR knowledge. METHODS AND RESULTS: The intended and performed strategy (before and after FFR) were compared. Among 172 patients, 84 with 300 lesions were randomized to the FFR-guided group. The intended strategy was to bypass 236 stenoses:108 with a venous and 128 with an arterial graft. After disclosing FFR, a change in strategy occurred in 64 lesions (21.3%) of 48 (55%) patients. Among 64 lesions for which the intended strategy was medical therapy, 16 (25%) were bypassed after disclosing FFR. The number of procedures with >1 venous graft planned was significantly reduced from 37 to 27 patients (p = .031). The proportion of on-pump surgery was significantly reduced from 71 to 61 patients (p = .006). The rates of clinical events at 1 year were similar between patients with or without at least one change in strategy. DISCUSSION: FFR-guided CABG is associated with a simplified surgical procedure in 55% of the patients, with similar clinical outcomes.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/cirugía , Estudios de Seguimiento , Humanos , Resultado del Tratamiento
18.
Cardiovasc Revasc Med ; 28S: 81-84, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33674218

RESUMEN

None of the commercially available self-expanding (SE)-trans-catheter heart valve (THVs) used for trans-catheter aortic valve replacement (TAVR) has a deflectable delivery system. This aspect can represent a shortcoming, especially in some anatomical scenario where THV advancement is challenging. The use of a snare catheter (SC), applying an external traction force, can increase THV trackability. We describe three different TAVR cases, in which a SE-THV was the only available option and where the THV delivery system advancement in the aortic arch was not feasible, if not with the combined use of a SC.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Cardiovasc Revasc Med ; 28: 14-19, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-32933874

RESUMEN

OBJECTIVES: To assess feasibility, safety and efficacy of hybrid approach, consisting in a combination of modern drug-eluting stent (DES) and drug-eluting balloon (DCB), for treatment of de-novo diffuse coronary artery disease (CAD). BACKGROUNDS: Contemporary DES are associated with a persistent risk of major cardiovascular events, due to in-stent thrombosis and restenosis. The hybrid approach, reducing the permanent metallic cage length, is supposed to mitigate the risk of device-related adverse events, especially in diffuse CAD. METHODS: This is a prospective, non-randomized, observational, multicenter study intended to obtain data from 100 consecutive patients affected by de-novo diffuse CAD undergoing percutaneous coronary intervention with a hybrid approach, consisting in the combined use of DES and DCB in contiguous coronary segments. The study is recorded in ClinicalTrials.gov with the identifier: NCT03939468. RESULTS: The primary endpoint is a device oriented composite end-point (DOCE) of cardiac death, target vessel myocardial infarction (TV-MI) and ischemia-driven target lesion revascularization (ID-TLR) in DES- and/or DCB-treated segment. DOCE will be assessed at 12-months follow-up. CONCLUSIONS: This will be the first study investigating the feasibility, safety and efficacy of hybrid DES/DCB approach for the treatment of de-novo diffuse CAD. Here we describe the rationale and the design of the study.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Preparaciones Farmacéuticas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Humanos , Intervención Coronaria Percutánea/efectos adversos , Proyectos Piloto , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
20.
Cardiovasc Revasc Med ; 28S: 98-101, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33250405

RESUMEN

Trans-catheter valve-in-valve (ViV) is a treatment option for patients affected by bioprosthetic heart valve (BHV) failure. Both aortic and mitral ViV procedures present several challenges compared to native valve replacement. To date, no data concerning the balloon-expandable MyVal (Meril, Vapi, India) trans-catheter heart valve (THV) use in ViV procedure have been provided. In this case series, we described for the first time its use in five different BHV failures.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Catéteres , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...