Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Am J Vet Res ; 72(7): 905-17, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21728851

RESUMEN

OBJECTIVE: To evaluate effects of imaging plane, flexion and extension, patient weight, and observer on computed tomographic (CT) image measurements of the area of the lumbosacral (L7-S1) intervertebral foramen (LSIF) in dogs. SAMPLE: 12 dog cadavers (2 were excluded because of foraminal stenosis). PROCEDURES: In each cadaver, sagittal, sagittal oblique, transverse oblique, and double oblique CT images were obtained at 3 zones (entrance, middle, and exit zones) of the region of the lateral lumbar spinal canal that comprises the LSIF while the lumbosacral junction (LSJ) was positioned in flexion or extension. Barium-impregnated polymethylmethacrylate was used to fill the intervertebral foramina to aid boundary detection. Measurements of interest were obtained. RESULTS: Among the dog cadavers, there was large variability in LSIF cross-sectional areas (range, 0.12 to 0.44 cm2; SD, 0.1 cm2) and in foraminal angles required to obtain a double oblique plane in LSJ extension (SD, 8 ° to 9 °). For LSIF area measurements in standard sagittal CT images, interobserver variability was 23% to 44% and intraobserver variability was 4% to 5%. Sagittal oblique images obtained during LSJ extension yielded smaller mean LSIF areas (0.30 cm2), compared with findings in sagittal images (0.37 to 0.52 cm2). The exit and middle zone areas were smaller than the entrance zone area in sagittal images obtained during LSJ extension. CONCLUSIONS AND CLINICAL RELEVANCE: Repeated measurements of the LSIF area in images obtained during LSJ extension may be unreliable as a result of interobserver variability and the effects of dog positioning and CT slice orientation.


Asunto(s)
Perros/anatomía & histología , Disco Intervertebral/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Sacro/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Animales , Bario/química , Cadáver , Femenino , Procesamiento de Imagen Asistido por Computador , Disco Intervertebral/anatomía & histología , Vértebras Lumbares/anatomía & histología , Masculino , Variaciones Dependientes del Observador , Linaje , Polimetil Metacrilato/química , Postura , Valores de Referencia , Reproducibilidad de los Resultados , Sacro/anatomía & histología , Canal Medular/anatomía & histología , Canal Medular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA