1.
Front Oncol ; 6: 156, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27446802

RESUMEN

More and more camera concepts are being investigated to try and seize the opportunity of instantaneous range verification of proton therapy treatments offered by prompt gammas emitted along the proton tracks. Focusing on one-dimensional imaging with a passive collimator, the present study experimentally compared in combination with the first, clinically compatible, dedicated camera device the performances of instances of the two main options: a knife-edge slit (KES) and a multi-parallel slit (MPS) design. These two options were experimentally assessed in this specific context as they were previously demonstrated through analytical and numerical studies to allow similar performances in terms of Bragg peak retrieval precision and spatial resolution in a general context. Both collimators were prototyped according to the conclusions of Monte Carlo optimization studies under constraints of equal weight (40 mm tungsten alloy equivalent thickness) and of the specificities of the camera device under consideration (in particular 4 mm segmentation along beam axis and no time-of-flight discrimination, both of which less favorable to the MPS performance than to the KES one). Acquisitions of proton pencil beams of 100, 160, and 230 MeV in a PMMA target revealed that, in order to reach a given level of statistical precision on Bragg peak depth retrieval, the KES collimator requires only half the dose the present MPS collimator needs, making the KES collimator a preferred option for a compact camera device aimed at imaging only the Bragg peak position. On the other hand, the present MPS collimator proves more effective at retrieving the entrance of the beam in the target in the context of an extended camera device aimed at imaging the whole proton track within the patient.

2.
Radiother Oncol ; 118(2): 232-7, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26774764

RESUMEN

BACKGROUND AND PURPOSE: To improve precision of particle therapy, in vivo range verification is highly desirable. Methods based on prompt gamma rays emitted during treatment seem promising but have not yet been applied clinically. Here we report on the worldwide first clinical application of prompt gamma imaging (PGI) based range verification. MATERIAL AND METHODS: A prototype of a knife-edge shaped slit camera was used to measure the prompt gamma ray depth distribution during a proton treatment of a head and neck tumor for seven consecutive fractions. Inter-fractional variations of the prompt gamma profile were evaluated. For three fractions, in-room control CTs were acquired and evaluated for dose relevant changes. RESULTS: The measurement of PGI profiles during proton treatment was successful. Based on the PGI information, inter-fractional global range variations were in the range of ±2 mm for all evaluated fractions. This is in agreement with the control CT evaluation showing negligible range variations of about 1.5mm. CONCLUSIONS: For the first time, range verification based on prompt gamma imaging was applied for a clinical proton treatment. With the translation from basic physics experiments into clinical operation, the potential to improve the precision of particle therapy with this technique has increased considerably.


Asunto(s)
Carcinoma Adenoide Quístico/radioterapia , Rayos gamma/uso terapéutico , Neoplasias de Cabeza y Cuello/radioterapia , Terapia de Protones/métodos , Carcinoma Adenoide Quístico/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
3.
Phys Med Biol ; 60(12): 4915-46, 2015 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-26057053

RESUMEN

A prompt gamma (PG) slit camera prototype recently demonstrated that Bragg Peak position in a clinical proton scanned beam could be measured with 1-2 mm accuracy by comparing an expected PG detection profile to a measured one. The computation of the expected PG detection profile in the context of a clinical framework is challenging but must be solved before clinical implementation. Obviously, Monte Carlo methods (MC) can simulate the expected PG profile but at prohibitively long calculation times. We implemented a much faster method that is based on analytical processing of precomputed MC data that would allow practical evaluation of this range monitoring approach in clinical conditions. Reference PG emission profiles were generated with MC simulations (PENH) in targets consisting of either (12)C, (14)N, (16)O, (31)P or (40)Ca, with 10% of (1)H. In a given geometry, the local PG emission can then be derived by adding the contribution of each element, according to the local energy of the proton obtained by continuous slowing down approximation and the local composition. The actual incident spot size is taken into account using an optical model fitted to measurements and by super sampling the spot with several rays (up to 113). PG transport in the patient/camera geometries and the detector response are modelled by convolving the PG production profile with a transfer function. The latter is interpolated from a database of transfer functions fitted to MC data (PENELOPE) generated for a photon source in a cylindrical phantom with various radiuses and a camera placed at various positions. As a benchmark, the analytical model was compared to MC and experiments in homogeneous and heterogeneous phantoms. Comparisons with MC were also performed in a thoracic CT. For all cases, the analytical model reproduced the prediction of the position of the Bragg peak computed with MC within 1 mm for the camera in nominal configuration. When compared to measurements, the shape of the profiles was well reproduced and agreement for the estimation of the position of the Bragg peak was within 2.7 mm on average (1.4 mm standard deviation). On a non-optimized MATLAB code, computation time with the analytical model is between 0.3 to 10 s depending on the number of rays simulated per spot. The analytical model can be further used to determine which spots are the best candidates to evaluate the range in clinical conditions and eventually correct for over- and under-shoots depending on the acquired PG profiles.


Asunto(s)
Cámaras gamma , Rayos gamma , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Terapia de Protones , Radiometría/instrumentación , Radioterapia Asistida por Computador/métodos , Simulación por Computador , Humanos , Método de Montecarlo