Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Opt ; 53(12): 2646-55, 2014 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-24787591

RESUMEN

We report on 400 nm broadband type I frequency doubling in a noncollinear geometry with pulse-front-tilted and chirped femtosecond pulses (λ =800 nm; Fourier transform limited pulse duration, 45 fs). With moderate power densities (2 to 10 GW/cm2) thus avoiding higher-order nonlinear phenomena, the energy conversion efficiency was up to 65%. Second-harmonic pulses of Fourier transform limited pulse duration shorter than the fundamental wave were generated, exhibiting good beam quality and no pulse-front tilt. High energy (20 mJ/pulse) was produced in a 40 mm diameter and 6 mm thick LBO crystal. To the best of our knowledge, this is the first demonstration of this optical configuration with sub-100-fs pulses. Good agreement between experimental results and simulations is obtained.

2.
Opt Express ; 21(9): 11441-7, 2013 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-23670000

RESUMEN

We present single shot nanoscale imaging using a table-top femtosecond soft X-ray laser harmonic source at a wavelength of 32 nm. We show that the phase retrieval process in coherent diffractive imaging critically depends on beam quality. Coherence and image fidelity are measured from single-shot coherent diffraction patterns of isolated nano-patterned slits. Impact of flux, wave front and coherence of the soft X-ray beam on the phase retrieval process and the image quality are discussed. After beam improvements, a final image reconstruction is presented with a spatial resolution of 78 nm (half period) in a single 20 fs laser harmonic shot.


Asunto(s)
Algoritmos , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Nanopartículas/ultraestructura , Difracción de Rayos X/métodos
3.
Opt Express ; 19(21): 19935-41, 2011 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-21997002

RESUMEN

Using an original CEP stabilization technique based on the linear electro-optical effect in a specific crystal, we achieved long term CEP stabilization of a 20 W, 1 kHz laser with residual noise as low as 440 mrad (rms). At 3 W, the CEP shot to shot noise is kept as low as 320 mrad (rms) over half an hour.

4.
Opt Express ; 19(4): 3677-85, 2011 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-21369193

RESUMEN

We present the first measurement of the attosecond emission generated from underdense plasma produced on a solid target. We generate high-order harmonics of a femtosecond Ti:sapphire laser focused in a weakly ionized underdense chromium plasma. Using the "Reconstruction of Attosecond Beating by Interference of Two-photon Transitions" (RABITT) technique, we show that the 11th to the 19th harmonic orders form in the time domain an attosecond pulse train with each pulse having 300 as duration, which is only 1.05 times the theoretical Fourier transform limit. Measurements reveal a very low positive group delay dispersion of 4200 as2. Beside its fundamental interest, high-order harmonic generation in plasma plumes could thus provide an intense source of attosecond pulses for applications.

5.
J Phys Chem A ; 114(36): 9902-18, 2010 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-20704179

RESUMEN

The NO(2) ion pair photodissociation dynamics leading to NO(+)(X(1)Sigma(+),v) + O(-)((2)P(3/2) or (2)P(1/2)), induced by a 1 kHz femtosecond laser with wavelengths near 400 nm, has been characterized using the coincidence vector correlation method. The ion pair production after four-photon absorption reaches more than 15% of the primary ionization. The kinetic energy release of the fragments demonstrates a significant vibrational excitation of the NO(+)(X(1)Sigma(+),v) molecular fragment. Recoil ion fragment emission is strongly aligned along the polarization axis of linearly polarized light or preferentially emitted in the plane perpendicular to the propagation axis of circularly polarized light. The formalism describing the recoil anisotropy for bound-to-bound n-photon transition inducing prompt axial recoil dissociation of a nonlinear molecule has been developed to interpret the measured anisotropies in terms of excitation pathways via near-resonant intermediate states of specific symmetries. Possible reaction pathways are discussed that are consistent with the data and supported by calculations of potential energy surfaces and transition moments.

6.
Phys Rev Lett ; 94(17): 173903, 2005 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-15904292

RESUMEN

We demonstrate the first experimental complete temporal characterization of high-harmonic XUV pulses by spectral phase interferometry, with an all-optical setup. This method allows us to perform single-shot measurements of the harmonic temporal profile and phase, revealing a remarkable shot-to-shot stability. We characterize harmonics generated in argon by a 50 fs 800 nm laser pulse. The 11th harmonic is found to be 22 fs long with a negative chirp rate of -4.8 x 10(27) s(-2). This duration can be reduced to 13 fs by modulating the polarization of the generating laser. The technique is easy to implement and could be routinely used in femtosecond XUV pump-probe experiments with harmonics.

7.
Phys Rev E Stat Nonlin Soft Matter Phys ; 69(2 Pt 2): 026402, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14995561

RESUMEN

Improving the temporal contrast of ultrashort and ultraintense laser pulses is a major technical issue for high-field experiments. This can be achieved using a so-called "plasma mirror." We present a detailed experimental and theoretical study of the plasma mirror that allows us to quantitatively assess the performances of this system. Our experimental results include time-resolved measurements of the plasma mirror reflectivity, and of the phase distortions it induces on the reflected beam. Using an antireflection coated plate as a target, an improvement of the contrast ratio by more than two orders of magnitude can be achieved with a single plasma mirror. We demonstrate that this system is very robust against changes in the pulse fluence and imperfections of the beam spatial profile, which is essential for applications.

11.
Phys Rev A Gen Phys ; 34(6): 5146-5149, 1986 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9897911
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...