Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Analyst ; 149(14): 3839-3849, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38855835

RESUMEN

Insulator-based electrokinetically driven microfluidic devices stimulated with direct current (DC) voltages are an attractive solution for particle separation, concentration, or isolation. However, to design successful particle manipulation protocols, it is mandatory to know the mobilities of electroosmosis, and linear and nonlinear electrophoresis of the microchannel/liquid/particle system. Several techniques exist to characterize the mobilities of electroosmosis and linear electrophoresis. However, only one method to characterize the mobility of nonlinear electrophoresis has been thoroughly assessed, which generally requires DC voltages larger than 1000 V and measuring particle velocity in a straight microchannel. Under such conditions, Joule heating, electrolysis, and the DC power source cost become a concern. Also, measuring particle velocity at high voltages is noisy, limiting characterization quality. Here we present a protocol-tested on 2 µm polystyrene particles-for characterizing the mobility of nonlinear electrophoresis of the liquid/particle system using a DC voltage of only 30 V and visual inspection of particle dynamics in a microchannel featuring insulating obstacles. Multiphysics numerical modelling was used to guide microchannel design and to correlate particle location during an experiment with electric field intensity. The method was validated against the conventional characterization protocol, exhibiting excellent agreement while significantly reducing measurement noise and experimental complexity.

2.
Diagnostics (Basel) ; 14(2)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38275468

RESUMEN

COVID-19 made explicit the need for rethinking the way in which we conduct testing for epidemic emergencies. During the COVID-19 pandemic, the dependence on centralized lab facilities and resource-intensive methodologies (e.g., RT-qPCR methods) greatly limited the deployment of widespread testing efforts in many developed and underdeveloped countries. Here, we illustrate the development of a simple and portable diagnostic kit that enables self-diagnosis of COVID-19 at home from saliva samples. We describe the development of a do-it-yourself (DIY) incubator for Eppendorf tubes that can be used to conduct SARS-CoV-2 detection with competitive sensitivity and selectivity from saliva at home. In a proof-of-concept experiment, we assembled Eppendorf-tube incubators at our home shop, prepared a single-tube mix of reagents and LAMP primers in our lab, and deployed these COVID-19 detection kits using urban delivery systems (i.e., Rappifavor or Uber) to more than 15 different locations in Monterrey, México. This straightforward strategy enabled rapid and cost-effective at-home molecular diagnostics of SARS-CoV-2 from real saliva samples with a high sensitivity (100%) and high selectivity (87%).

3.
Electrophoresis ; 45(1-2): 69-100, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37259641

RESUMEN

Proteins are important molecules involved in an immensely large number of biological processes. Being capable of manipulating proteins is critical for developing reliable and affordable techniques to analyze and/or detect them. Such techniques would enable the production of therapeutic agents for the treatment of diseases or other biotechnological applications (e.g., bioreactors or biocatalysis). Microfluidic technology represents a potential solution to protein manipulation challenges because of the diverse phenomena that can be exploited to achieve micro- and nanoparticle manipulation. In this review, we discuss recent contributions made in the field of protein manipulation in microfluidic systems using different physicochemical principles and techniques, some of which are miniaturized versions of already established macro-scale techniques.


Asunto(s)
Técnicas Analíticas Microfluídicas , Nanopartículas , Microfluídica/métodos , Técnicas Analíticas Microfluídicas/métodos , Nanopartículas/química , Dispositivos Laboratorio en un Chip
4.
Electrophoresis ; 44(1-2): 268-297, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36205631

RESUMEN

Temperature is a critical-yet sometimes overlooked-parameter in microfluidics. Microfluidic devices can experience heating inside their channels during operation due to underlying physicochemical phenomena occurring therein. Such heating, whether required or not, must be monitored to ensure adequate device operation. Therefore, different techniques have been developed to measure and control temperature in microfluidic devices. In this contribution, the operating principles and applications of these techniques are reviewed. Temperature-monitoring instruments revised herein include thermocouples, thermistors, and custom-built temperature sensors. Of these, thermocouples exhibit the widest operating range; thermistors feature the highest accuracy; and custom-built temperature sensors demonstrate the best transduction. On the other hand, temperature control methods can be classified as external- or integrated-methods. Within the external methods, microheaters are shown to be the most adequate when working with biological samples, whereas Peltier elements are most useful in applications that require the development of temperature gradients. In contrast, integrated methods are based on chemical and physical properties, structural arrangements, which are characterized by their low fabrication cost and a wide range of applications. The potential integration of these platforms with the Internet of Things technology is discussed as a potential new trend in the field.


Asunto(s)
Técnicas Analíticas Microfluídicas , Temperatura , Microfluídica/métodos , Dispositivos Laboratorio en un Chip
5.
Electrophoresis ; 43(1-2): 327-339, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34717000

RESUMEN

Exosomes are small extracellular vesicles that can be obtained from several body fluids such as blood and urine. Since these vesicles can carry biomarkers and other cargo, they have application in healthcare diagnostics and therapeutics, such as liquid biopsies and drug delivery. Yet, their identification and separation from a sample remain challenging due to their high degree of heterogeneity and their co-existence with other bioparticles. In this contribution, we review the state-of-the-art on electrical techniques and methods to displace, selectively trap/isolate, and detect/characterize exosomes in microfluidic devices. Although there are many reviews focused on exosome separation using benchtop equipment, such as ultracentrifugation, there are limited reviews focusing on the use of electrical phenomena in microfluidic devices for exosome manipulation and detection. Here, we highlight contributions published during the past decade and present perspectives for this research field for the near future, outlining challenges to address in years to come.


Asunto(s)
Exosomas , Vesículas Extracelulares , Dispositivos Laboratorio en un Chip , Biopsia Líquida , Microfluídica , Ultracentrifugación
6.
Electrophoresis ; 43(1-2): 249-262, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34632600

RESUMEN

The survival of living beings, including humanity, depends on a continuous supply of clean water. However, due to the development of industry, agriculture, and population growth, an increasing number of wastewaters is discarded, and the negative effects of such actions are clear. The first step in solving this situation is the collection and monitoring of pollutants in water bodies to subsequently facilitate their treatment. Nonetheless, traditional sensing techniques are typically laboratory-based, leading to potential diminishment in analysis quality. In this paper, the most recent developments in micro- and nano-electrochemical devices for pollutant detection in wastewater are reviewed. The devices reviewed are based on a variety of electrodes and the sensing of three different categories of pollutants: nutrients and phenolic compounds, heavy metals, and organic matter. From these electrodes, Cu, Co, and Bi showed promise as versatile materials to detect a grand variety of contaminants. Also, the most commonly used material is glassy carbon, present in the detection of all reviewed analytes.


Asunto(s)
Contaminantes Ambientales , Metales Pesados , Nanoestructuras , Técnicas Electroquímicas , Electrodos , Contaminantes Ambientales/análisis , Metales Pesados/análisis , Nanoestructuras/química , Agua
7.
Lab Chip ; 21(23): 4596-4607, 2021 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-34739022

RESUMEN

Insulator-based microfluidic devices are attractive for handling biological samples due to their simple fabrication, low-cost, and efficiency in particle manipulation. However, their widespread application is limited by the high operation voltages required to achieve particle trapping. We present a theoretical, numerical, and experimental study that demonstrates these voltages can be significantly reduced (to sub-100 V) in direct-current insulator-based electrokinetic (DC-iEK) devices for micron-sized particles. To achieve this, we introduce the concept of the amplification factor-the fold-increase in electric field magnitude due to the presence of an insulator constriction-and use it to compare the performance of different microchannel designs and to direct our design optimization process. To illustrate the effect of using constrictions with smooth and sharp features on the amplification factor, geometries with circular posts and semi-triangular posts were used. These were theoretically approximated in two different systems of coordinates (bipolar and elliptic), allowing us to provide, for the first time, explicit electric field amplification scaling laws. Finite element simulations were performed to approximate the 3D insulator geometries and provide a parametric study of the effect of changing different geometrical features. These simulations were used to predict particle trapping voltages for four different single-layer microfluidic devices using two particle suspensions (2 and 6.8 µm in size). The general agreement between our models demonstrates the feasibility of using the amplification factor, in combination with nonlinear electrokinetic theory, to meet the prerequisites for the development of portable DC-iEK microfluidic systems.


Asunto(s)
Técnicas Analíticas Microfluídicas , Electricidad , Electroforesis , Dispositivos Laboratorio en un Chip , Microfluídica , Tamaño de la Partícula
8.
Micromachines (Basel) ; 12(9)2021 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-34577668

RESUMEN

In this study, we carried out a heterogeneous cytoplasmic lipid content screening of Neochloris oleoabundans microalgae by dielectrophoresis (DEP), using castellated glassy carbon microelectrodes in a PDMS microchannel. For this purpose, microalgae were cultured in nitrogen-replete (N+) and nitrogen-deplete (N-) suspensions to promote low and high cytoplasmic lipid production in cells, respectively. Experiments were carried out over a wide frequency window (100 kHz-30 MHz) at a fixed amplitude of 7 VPP. The results showed a statistically significant difference between the dielectrophoretic behavior of N+ and N- cells at low frequencies (100-800 kHz), whereas a weak response was observed for mid- and high frequencies (1-30 MHz). Additionally, a finite element analysis using a 3D model was conducted to determine the dielectrophoretic trapping zones across the electrode gaps. These results suggest that low-cost glassy carbon is a reliable material for microalgae classification-between low and high cytoplasmic lipid content-through DEP, providing a fast and straightforward mechanism.

9.
Electrophoresis ; 42(23): 2445-2464, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34081787

RESUMEN

Electrokinetically driven insulator-based microfluidic devices represent an attractive option to manipulate particle suspensions. These devices can filtrate, concentrate, separate, or characterize micro and nanoparticles of interest. Two decades ago, inspired by electrode-based dielectrophoresis, the concept of insulator-based dielectrophoresis (iDEP) was born. In these microfluidic devices, insulating structures (i.e., posts, membranes, obstacles, or constrictions) built within the channel are used to deform the spatial distribution of an externally generated electric field. As a result, particles suspended in solution experience dielectrophoresis (DEP). Since then, it has been assumed that DEP is responsible for particle trapping in these devices, regardless of the type of voltage being applied to generate the electric field-direct current (DC) or alternating current. Recent findings challenge this assumption by demonstrating particle trapping and even particle flow reversal in devices that prevent DEP from occurring (i.e., unobstructed long straight channels stimulated with a DC voltage and featuring a uniform electric field). The theory introduced to explain those unexpected observations was then applied to conventional "DC-iDEP" devices, demonstrating better prediction accuracy than that achieved with the conventional DEP-centered theory. This contribution summarizes contributions made during the last two decades, comparing both theories to explain particle trapping and highlighting challenges to address in the near future.


Asunto(s)
Técnicas Analíticas Microfluídicas , Microfluídica , Electroforesis , Dispositivos Laboratorio en un Chip
10.
Anal Chem ; 92(19): 12871-12879, 2020 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-32894016

RESUMEN

The classic theory of direct-current (DC) insulator-based dielectrophoresis (iDEP) considers that, in order to elicit particle trapping, dielectrophoretic (DEP) velocity counterbalances electrokinetic (EK) motion, that is, electrophoresis (EP) and electro-osmotic flow (EOF). However, the particle velocity DEP component requires empirical correction factors (sometimes as high as 600) to account for experimental observations, suggesting the need for a refined model. Here, we show that, when applied to particle suspensions, a high-magnitude DC uniform electric field induces nonlinear particle velocities, leading to particle flow reversal beyond a critical field magnitude, referred to as the EK equilibrium condition. We further demonstrate that this particle motion can be described through an exploratory induced-charge EP nonlinear model. The model predictions were validated under an insulator-based microfluidic platform demonstrating predictive particle trapping for three different particle sizes (with an estimation error < 10%, not using correction factors). Our findings suggest that particle motion and trapping in "DC-iDEP" devices are dominated by EP and EOF, rather than by DEP effects.

11.
Anal Chem ; 91(23): 14975-14982, 2019 12 03.
Artículo en Inglés | MEDLINE | ID: mdl-31738514

RESUMEN

Exosomes are a specific subpopulation of extracellular vesicles that have gained interest because of their many potential biomedical applications. However, exosome isolation and characterization are the first steps toward designing novel applications. This work presents a direct current-insulator-based dielectrophoretic (DC-iDEP) approach to simultaneously capture and separate exosomes by size. To do so, a microdevice consisting of a channel with two electrically insulating post sections was designed. Each section was tailored to generate different nonuniform spatial distributions of the electric field and, therefore, different dielectrophoretic forces acting on exosomes suspended in solution. Side channels were placed adjacent to each section to allow sample recovery. By applying an electric potential difference of 2000 V across the length of the main channel, dielectrophoretic size-based separation of exosomes was observed in the device. Analysis of particle size in each recovered fraction served to assess exosome separation efficiency. These findings show that iDEP can represent a first step toward designing a high-throughput, fast, and robust microdevice capable of capturing and discriminating different subpopulations of exosomes based on their size.


Asunto(s)
Electroforesis/instrumentación , Exosomas , Técnicas Analíticas Microfluídicas/métodos , Electroforesis/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Tamaño de la Partícula
12.
Electrophoresis ; 40(23-24): 3036-3049, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31373715

RESUMEN

Exosomes are nanovesicles secreted by most cellular types that carry important biochemical compounds throughout the body with different purposes, playing a preponderant role in cellular communication. Because of their structure, physicochemical properties and stability, recent studies are focusing in their use as nanocarriers for different therapeutic compounds for the treatment of different diseases ranging from cancer to Parkinson's disease. However, current bioseparation protocols and methodologies are selected based on the final exosome application or intended use and present both advantages and disadvantages when compared among them. In this context, this review aims to present the most important technologies available for exosome isolation while discussing their advantages and disadvantages and the possibilities of being combined with other strategies. This is critical since the development of novel exosome-based therapeutic strategies will be constrained to the effectiveness and yield of the selected downstream purification methodologies for which a thorough understanding of the available technological resources is needed.


Asunto(s)
Biotecnología/métodos , Técnicas de Química Analítica/métodos , Exosomas , Células Cultivadas , Humanos , Técnicas Analíticas Microfluídicas/métodos
13.
Electrophoresis ; 40(10): 1408-1416, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30883810

RESUMEN

Insulator-based dielectrophoresis (iDEP) is the electrokinetic migration of polarized particles when subjected to a non-uniform electric field generated by the inclusion of insulating structures between two remote electrodes. Electrode spacing is considerable in iDEP systems when compared to electrode-based DEP systems, therefore, iDEP systems require high voltages to achieve efficient particle manipulation. A consequence of this is the temperature increase within the channel due to Joule heating effects, which, in some cases, can be detrimental when manipulating biological samples. This work presents an experimental and modeling study on the increase in temperature inside iDEP devices. For this, we studied seven distinct channel designs that mainly differ from each other in their post array characteristics: post shape, post size and spacing between posts. Experimental results obtained using a custom-built copper Resistance Temperature Detector, based on resistance changes, show that the influence of the insulators produces a difference in temperature rise of approximately 4°C between the designs studied. Furthermore, a 3D COMSOL model is also introduced to evaluate heat generation and dissipation, which is in good agreement with the experiments. The model allowed relating the difference in average temperature for the geometries under study to the electric resistance posed by the post array in each design.


Asunto(s)
Electroforesis/instrumentación , Electroforesis/métodos , Diseño de Equipo , Técnicas Analíticas Microfluídicas/instrumentación , Modelos Teóricos , Temperatura
14.
Anal Chem ; 90(7): 4310-4315, 2018 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-29528220

RESUMEN

Insulator-based dielectrophoresis (iDEP) is a microfluidic technique used for particle analysis in a wide array of applications. Significant efforts are dedicated to improve iDEP systems by reducing voltage requirements. This study assesses how the performance of an iDEP system, in terms of particle trapping, depends on the number of insulating obstacles longitudinally present in the microchannel. In analogy with Kirchhoff's loop rule, iDEP systems were analyzed as a series combination of electrical resistances, where the equivalent resistance of the post array is composed by a number of individual resistors (columns of insulating posts). It was predicted by the COMSOL model, and later confirmed by experimental results, that reducing the number of columns of insulating posts significantly affects the electric field distribution, decreasing the required voltage to dielectrophoretically trap particles within the post array. As an application, it was demonstrated that decreasing the number of columns in the post array allows for the dielectrophoretic trapping of nanometer-scale particles at voltages well below those reported in previous similar iDEP systems. These findings illustrate how the iDEP channel configuration can be customized for specific applications.

15.
Biomicrofluidics ; 10(3): 033106, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27375815

RESUMEN

Synthesis of PEGylated proteins results in a mixture of protein-polyethylene glycol (PEG) conjugates and the unreacted native protein. From a ribonuclease A (RNase A) PEGylation reaction, mono-PEGylated RNase A (mono-PEG RNase A) has proven therapeutic effects against cancer, reason for which there is an interest in isolating it from the rest of the reaction products. Experimental trapping of PEGylated RNase A inside an electrokinetically driven microfluidic device has been previously demonstrated. Now, from a theoretical point of view, we have studied the electrokinetic phenomena involved in the dielectrophoretic streaming of the native RNase A protein and the trapping of the mono-PEG RNase A inside a microfluidic channel. To accomplish this, we used two 3D computational models, a sphere and an ellipse, adapted to each protein. The effect of temperature on parameters related to trapping was also studied. A temperature increase showed to rise the electric and thermal conductivities of the suspending solution, hindering dielectrophoretic trapping. In contrast, the dynamic viscosity of the suspending solution decreased as the temperature rose, favoring the dielectrophoretic manipulation of the proteins. Also, our models were able to predict the magnitude and direction of the velocity of both proteins indicating trapping for the PEGylated conjugate or no trapping for the native protein. In addition, a parametric sweep study revealed the effect of the protein zeta potential on the electrokinetic response of the protein. We believe this work will serve as a tool to improve the design of electrokinetically driven microfluidic channels for the separation and recovery of PEGylated proteins in one single step.

16.
J Invertebr Pathol ; 119: 54-61, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24769124

RESUMEN

Prior knowledge of the local population structure of entomopathogenic fungi is considered an important requisite when developing microbial control strategies against major pests of crops such as white grubs. An extensive survey in the estate of Guanajuato, one of the main agricultural regions of Mexico, was carried out to determine the abundance and diversity of entomopathogenic fungi in soil. Soil collected from 11 locations was baited for entomopathogenic fungi using Galleria mellonella. In addition, all isolates were morphologically identified and selected isolates of Beauveria and Metarhizium isolates identified using Bloc and ITS or Elongation Factor 1-α and ITS sequence information respectively. Genotypic diversity was then studied using microsatellite genotyping. The proportion of isolates belonging to each genus varied amongst all locations. The species Beauveria bassiana, B. pseudobassiana and Metarhizium robertsii were found, with B. bassiana being the most abundant and widely distributed. Microsatellite genotyping showed that the 36 B. bassiana isolates were grouped in 29 unique haplotypes, but with no separation according to geographical origin.


Asunto(s)
Beauveria/genética , Metarhizium/genética , Microbiología del Suelo , Genotipo , México , Filogenia , Reacción en Cadena de la Polimerasa
17.
Lab Chip ; 13(23): 4642-52, 2013 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-24121252

RESUMEN

In this work, a novel approach to 3-dimensional (3D) electrode fabrication, based on electrodeposited polypyrrole (PPy), for dielectrophoresis (DEP) is described. 3D PPy electrodes with post and cage geometries were grown over planar interdigitated electrodes. Computational modelling and experimental work were carried out to assess the performance of the proposed electrode geometries. It was found that these new electrode geometries enhanced the dielectrophoretic trapping efficiency for polystyrene beads by exhibiting larger variations of the electric field and by affecting a larger volume of the fluid sample than planar electrodes. Applications of this work include, but are not limited to, environmental monitoring, food safety control, clinical analysis, and clean energy production.


Asunto(s)
Electrodos , Electroforesis/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Polímeros/química , Pirroles/química , Monitoreo del Ambiente , Polímeros/síntesis química , Poliestirenos/química , Pirroles/síntesis química
18.
Electrophoresis ; 32(18): 2502-11, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21853448

RESUMEN

Dielectrophoresis (DEP) is the motion of particles due to polarization effects in nonuniform electric fields. DEP has great potential for handling cells and is a non-destructive phenomenon. It has been utilized for different cell analysis, from viability assessments to concentration enrichment and separation. Insulator-based DEP (iDEP) provides an attractive alternative to conventional electrode-based systems; in iDEP, insulating structures are used to generate nonuniform electric fields, resulting in simpler and more robust devices. Despite the rapid development of iDEP microdevices for applications with cells, the fundamentals behind the dielectrophoretic behavior of cells has not been fully elucidated. Understanding the theory behind iDEP is necessary to continue the progress in this field. This work presents the manipulation and separation of bacterial and yeast cells with iDEP. A computational model in COMSOL Multiphysics was employed to predict the effect of direct current-iDEP on cells suspended in a microchannel containing an array of insulating structures. The model allowed predicting particle behavior, pathlines and the regions where dielectrophoretic immobilization should occur. Experimental work was performed at the same operating conditions employed with the model and results were compared, obtaining good agreement. This is the first report on the mathematical modeling of the dielectrophoretic response of yeast and bacterial cells in a DC-iDEP microdevice.


Asunto(s)
Separación Celular/métodos , Electroforesis/métodos , Escherichia coli/química , Técnicas Analíticas Microfluídicas/métodos , Saccharomyces cerevisiae/química , Membrana Celular/química , Pared Celular/química , Citoplasma/química , Conductividad Eléctrica , Escherichia coli/citología , Modelos Teóricos , Saccharomyces cerevisiae/citología
19.
Electrophoresis ; 32(18): 2456-65, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21874656

RESUMEN

Dielectrophoresis is the electrokinetic movement of particles due to polarization effects in the presence of non-uniform electric fields. In insulator-based dielectrophoresis (iDEP) regions of low and high electric field intensity, i.e. non-uniformity of electric field, are produced when the cross-sectional area of a microchannel is decreased by the presence of electrical insulating structures between two electrodes. This technique is increasingly being studied for the manipulation of a wide variety of particles, and novel designs are continuously developed. Despite significant advances in the area, complex mixture separation and sample fractionation continue to be the most important challenges. In this work, a microchannel design is presented for carrying out direct current (DC)-iDEP for the separation of a mixture of particles. The device comprises a main channel, two side channels and two sections of cylindrical posts with different diameters, which will generate different non-uniformities in the electric field on the main channel, designed for the discrimination and separation of particles of two different sizes. By applying an electric potential of 1000 V, a mixture of 1 and 4 µm polystyrene microspheres were dielectrophoretically separated and concentrated at the same time and then redirected to different outlets. The results obtained here demonstrate that, by carefully designing the device geometry and selecting operating conditions, effective sorting of particle mixtures can be achieved in this type of multi-section DC-iDEP devices.


Asunto(s)
Electroforesis/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Modelos Químicos , Simulación por Computador , Conductividad Eléctrica , Microesferas , Tamaño de la Partícula , Poliestirenos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA