Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Econ Entomol ; 112(2): 957-962, 2019 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-30476216

RESUMEN

Heat treatments (HTs) for pest control represent a promising, fast, and non-chemical method to disinfest commodities and structures with a significantly reduced environmental impact compared with the chemical approach. An entomological and economic study has been conducted to determine the technical efficacy and economic feasibility of HT in mills that produce flour and semolina in Sicily (Italy) where, for the first time, this technique has been applied. The results obtained from the entomological analysis demonstrated that this method provided a satisfactory level of control of the following insect species: Sitophilus oryzae (L.) (Coleoptera: Curculionidae), Rhyzopertha dominica (F.) (Coleoptera: Bostrichidae), Tribolium confusum (Jacquelin du Val) (Coleoptera: Tenebrionidae), Stegobium paniceum (L.) (Coleoptera: Anobiidae), and Ephestia kuehniella (Zeller) (Lepidoptera: Pyralidae). Moreover, using precautionary assumptions in terms of revenue and cost changes resulting from the adoption of HT, the economic analysis showed a good performance of the economic indices making this technique economically feasible for the mills. Overall, the results of this study demonstrate the technical and economic feasibility of HTs which ensure to Sicilian mills a reduction of environmental impact of production process and the subsequent increase of the competitive position in the agri-food markets of the processed products.


Asunto(s)
Escarabajos , Insecticidas , Animales , Estudios de Factibilidad , Calor , Control de Plagas , Sicilia
2.
Anticancer Res ; 17(3B): 1627-30, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9179207

RESUMEN

99mTc MIBI scintimammography is a sensitive and specific diagnostic technique for breast cancer detection when cancers more than 1 cm sized are considered. However the sensitivity falls in the case of submillimetric lesions. We developed a new Small Field of View, High Resolution Detector, able to image the breast in similar conditions of x-ray mammography: it allows the performance of Single Photon Emission Mammography (SPEM) studies. Seven patients with suspicion of malignant lesions were comparatively submitted to a Prone Scintimammography (PSM) by Anger camera and to a cranio-caudal view SPEM. The final diagnosis was reached by histopathology. Four malignant lesions were identified by SPEM but not by PSM, which that failed to image two submillimetric cancers. Both the cameras gave normal findings for benign lesions, confirming the high sensitivity of this technique. The results allow us to consider the SPEM camera as promising to improve scintimammographic sensitivity, even when small-sized tumors are examined.


Asunto(s)
Enfermedades de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/diagnóstico por imagen , Fibroadenoma/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi , Calcinosis/diagnóstico por imagen , Diagnóstico Diferencial , Femenino , Cámaras gamma , Humanos , Mamografía , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión/instrumentación
3.
Anticancer Res ; 17(3B): 1651-4, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9179212

RESUMEN

The development of large area Position Sensitive Photo Multiplier Tubes (PSPMT) by Hamamatsu is opening new imaging possibilities in Nuclear Medicine. In particular the realization of the 8" PSPMT prototype represents the first important technological advantage since the discovery of the Anger Camera. PSPMT virtually integrates in one hundreds PMT allowing the creation of dedicated detectors. A Single Tube Gamma Camera based on a 5" PSPMT dedicated to scintimammography is presented and discussed in this work. To optimize gamma camera response two different scintillating arrays were tested: YAP:Ce and CsI (Tl). Their overall size cover all photocathode active area, and crystal pixel size was 2 mm x 2 mm. The detection efficiency was comparable to that of Anger Camera. The best result was obtained by CsI (Tl) scintillating: an intrinsic spatial resolution of 1.6 mm FWHM and a relative energy resolution of 17% FWHM. New image possibilities in scintimammography are offered by Single Tube Gamma Camera operating in the same radiological projection of RX mammography.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Cámaras gamma , Diseño de Equipo , Femenino , Humanos , Mamografía , Valor Predictivo de las Pruebas , Cintigrafía , Conteo por Cintilación , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA