Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
Rev Port Cardiol (Engl Ed) ; 40(2): 71-76, 2021 Feb.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-33402278

RESUMEN

INTRODUCTION AND OBJECTIVES: The Stents Coated With the Biodegradable Polymer on Their Abluminal Faces and Elution of Sirolimus Versus Biolimus Elution for the Treatment of de Novo Coronary Lesions - DESTINY Trial is a non-inferiority randomized study that compared the Inspiron™ sirolimus-eluting stent (SES) with the control Biomatrix™ Flex biolimus-eluting stent (BES). Previous reports in the first year showed similar outcomes for both stents, in clinical, angiographic, optical coherence tomography, and intravascular ultrasound assessments. The present analysis aims to compare the clinical performance of these two biodegradable polymer drug-eluting stents five years after the index procedure. METHODS: A total of 170 patients (194 lesions) were randomized in a 2:1 ratio for treatment with SES or BES, respectively. The primary endpoint for the present study was the five-year rate of combined major adverse cardiac events, defined as cardiac death, myocardial infarction, or target lesion revascularization. RESULTS: At five years, the primary endpoint occurred in 12.5% and 17.9% of the SES and BES groups, respectively (p=0.4). There was no definite or probable stent thrombosis among patients treated with the novel SES stent during the five years of follow-up, and no stent thrombosis after the first year in the BES group. CONCLUSIONS: The novel Inspiron™ stent had similar good clinical performance in long-term follow-up when compared head-to-head with the control latest-generation Biomatrix™ Flex biolimus-eluting stent.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Polímeros , Diseño de Prótesis , Resultado del Tratamiento
2.
Cardiovasc. revasc. med ; Cardiovasc. revasc. med;21(5): 640-646, May. 2020. ilu, tab, grá
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1123570

RESUMEN

Background/purpose: This study sought to determine the diagnostic accuracy of 320-row computed tomography (320CT) for characterizing coronary atherosclerotic plaques in comparison with optical coherence tomography (OCT). Methods/materials: From 32 patients, 42 coronary segments were evaluated and co-registered by both 320CT and OCT. 320CT vulnerable plaque characteristics included low attenuation plaque (LAP) (b30HU), napkin-ring sign (NRS), positive remodeling (PR) and spotty calcification (SC). The presence of macrophage, neovascularization and cholesterol crystals was also determined by OCT. Results: Minimal lumen area was 2.78 ± 1.23 mm by OCT and 3.29 ± 1.49 mm by 320CT (p b 0.001). Noncalcified plaques were classified accordingly by both methods in 88.2% of the cases (p = 0.005). There was no association between any 320CT plaque type and OCT fibroatheroma (p = 0.62). The combination of 2 or more of the 320CT vulnerable plaque characteristics was associated with the presence of macrophage (74.2 vs. 25.8%; p = 0.034) and cholesterol crystals (85.7 vs. 14.3%; p = 0.04), but not with neovascularization (p = 0.65). The presence of all four characteristics demonstrated an accuracy of 75.1% for detecting OCT fibroatheroma. Conclusions: 320CT is useful for non-invasive evaluation of calcified and noncalcified tissue characteristics of coronary atheroma. The combination of all four 320CT vulnerable plaque characteristics provided the highest accuracy for detecting fibroatheromas. ITALIC] Summary: 320CT is useful for non-invasive evaluation of calcified and noncalcified tissue characteristics of coronary atheroma. The combination of all 320CT vulnerable plaque characteristics (low attenuation plaque (b30HU), napkin-ring sign, positive remodeling and spotty calcification) provided the highest accuracy for detecting fibroatheromas compared to optical coherence tomography


Asunto(s)
Enfermedad de la Arteria Coronaria , Colesterol/análisis , Calcificación Vascular , Pronóstico , Fibrosis , Sistema de Registros , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Angiografía Coronaria , Vasos Coronarios , Cristalización , Tomografía de Coherencia Óptica , Placa Aterosclerótica , Tomografía Computarizada Multidetector , Angiografía por Tomografía Computarizada , Macrófagos/patología , Neovascularización Patológica
3.
Rev. esp. de cardiol. (Internet. Engl. ed.) ; 72(1): 21-29, Jan. 2019. tab, graf
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1023736

RESUMEN

Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI) and is associated with higher mortality. However, the impact of AKI on long-term outcomes remains controversial. Therefore, we sought to evaluate the impact of AKI on short- and long-term outcomes following TAVI using the Valve Academic Research Consortium 2 criteria. METHODS: Consecutive patients (n = 794) with severe aortic stenosis who underwent TAVI were included in a multicenter Brazilian registry. Logistic regression analysis was used to identify predictors of AKI. Four-year outcomes were determined as Kaplan-Meier survival curves, and an adjusted landmark analysis was used to test the impact of AKI on mortality among survivors at 12 months. RESULTS: The incidence of AKI after TAVI was 18%. Independent predictors of AKI were age, diabetes mellitus, major or life-threatening bleeding and valve malpositioning. Acute kidney injury was independently associated with higher risk of all-cause death (adjusted HR, 2.8; 95%CI, 2.0-3.9; P < .001) and cardiovascular mortality (adjusted HR, 2.9; 95%CI, 1.9-4.4; P < .001) over the entire follow-up period. However, when considering only survivors at 12 months, there was no difference in both clinical endpoints (adjusted HR, 1.2; 95%CI, 0.5-2.4; P = .71, and HR, 0.7; 95%CI, 0.2-2.1; P = .57, respectively). CONCLUSIONS: Acute kidney injury is a frequent complication after TAVI. Older age, diabetes, major or life-threatening bleeding, and valve malpositioning were independent predictors of AKI. Acute kidney injury is associated with worse short- and long-term outcomes. However, the major impact of AKI on mortality is limited to the first year after TAVI. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved. KEYWORDS: Acute kidney injury; Aortic stenosis; Daño renal agudo; Edad avanzada; Elderly; Estenosis aórtica; Implante percutáneo de válvula aórtica; Mortalidad; Mortality; Transcatheter aortic valve implantation; Valve Academic Research Consortium.


Asunto(s)
Humanos , Lesión Renal Aguda , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Periodo Posoperatorio
4.
Rev Esp Cardiol (Engl Ed) ; 72(1): 21-29, 2019 Jan.
Artículo en Inglés, Español | MEDLINE | ID: mdl-29358043

RESUMEN

INTRODUCTION AND OBJECTIVES: Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI) and is associated with higher mortality. However, the impact of AKI on long-term outcomes remains controversial. Therefore, we sought to evaluate the impact of AKI on short- and long-term outcomes following TAVI using the Valve Academic Research Consortium 2 criteria. METHODS: Consecutive patients (n = 794) with severe aortic stenosis who underwent TAVI were included in a multicenter Brazilian registry. Logistic regression analysis was used to identify predictors of AKI. Four-year outcomes were determined as Kaplan-Meier survival curves, and an adjusted landmark analysis was used to test the impact of AKI on mortality among survivors at 12 months. RESULTS: The incidence of AKI after TAVI was 18%. Independent predictors of AKI were age, diabetes mellitus, major or life-threatening bleeding and valve malpositioning. Acute kidney injury was independently associated with higher risk of all-cause death (adjusted HR, 2.8; 95%CI, 2.0-3.9; P < .001) and cardiovascular mortality (adjusted HR, 2.9; 95%CI, 1.9-4.4; P < .001) over the entire follow-up period. However, when considering only survivors at 12 months, there was no difference in both clinical endpoints (adjusted HR, 1.2; 95%CI, 0.5-2.4; P = .71, and HR, 0.7; 95%CI, 0.2-2.1; P = .57, respectively). CONCLUSIONS: Acute kidney injury is a frequent complication after TAVI. Older age, diabetes, major or life-threatening bleeding, and valve malpositioning were independent predictors of AKI. Acute kidney injury is associated with worse short- and long-term outcomes. However, the major impact of AKI on mortality is limited to the first year after TAVI.


Asunto(s)
Lesión Renal Aguda/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Lesión Renal Aguda/etiología , Anciano de 80 o más Años , Brasil/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
5.
Arq. bras. cardiol ; Arq. bras. cardiol;109(6): 550-559, Dec. 2017. tab, graf
Artículo en Inglés | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-887985

RESUMEN

Abstract Background: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. Objectives: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. Methods: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. Results: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). Conclusion: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Resumo Fundamento: O implante valvar aórtico transcateter (TAVI) está bem estabelecido, porém, o bloqueio atrioventricular, com necessidade de marca-passo definitivo (MPD), é complicação frequente. Objetivo: Determinar a incidência, preditores e desfechos clínicos de implante de MPD após TAVI, focando em como a evolução da fração de ejeção do ventrículo esquerdo (FEVE), após o TAVI, é afetada pelo MPD. Métodos: No registro brasileiro foram incluídos 819 pacientes submetidos a TAVI por estenose aórtica severa em 22 centros entre janeiro/2008 e janeiro/2015. Após exclusões, os preditores de implante de MPD foram avaliados em 670 pacientes por regressão multivariada. Análise da curva ROC foi utilizada para medir a habilidade dos preditores; p < 0,05 foi considerado significativo. Resultados: Aos 30 dias, 135 pacientes (20,1%) necessitaram de MPD. Tais pacientes eram mais velhos (82,5 vs. 81,1 anos; p = 0,047) e predominantemente homens (59,3% vs 45%; p = 0,003). A permanência hospitalar foi maior no Grupo MPD (média= 15,7 ± 25,7 vs. 11,8 ± 22,9 dias; p < 0,001), mas o implante não afetou morte por qualquer causa (26,7% vs. 25,6%; p = 0,80) nem morte cardiovascular (14,1% vs. 14,8%; p = 0,84). Por análise multivariada, a presença prévia de bloqueio de ramo direito (BRD) (OR, 6,19; 3,56-10,75; p ≤ 0,001), o uso da prótese CoreValve® (OR, 3,16; 1,74-5,72; p ≤ 0,001) e gradiente transaórtico basal > 50 mmHg (OR, 1,86; 1,08-3,2; p= 0,025) foram preditores de implante de MPD. O risco estimado de implante de MPD foi 4%, quando nenhum dos fatores de risco estava presente, e 63% na presença de todos. O modelo mostrou boa habilidade de prever a necessidade de MPD: 0,69 (IC95%: 0,64 - 0,74) na curva ROC. Subestudo de 287 ecocardiogramas durante o seguimento de 1 ano mostrou pior evolução da FEVE no Grupo MPD (p = 0,01). Conclusão: Em crianças de 6 a 11 anos, circunferência da cintura aumentada está associada à PA elevada, mesmo quando o IMC é normal. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Asunto(s)
Humanos , Masculino , Femenino , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Marcapaso Artificial/efectos adversos , Bloqueo de Rama/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Estimulación Cardíaca Artificial/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Bloqueo Atrioventricular/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias , Brasil , Factores de Riesgo , Electrocardiografía , Bloqueo Atrioventricular/fisiopatología
6.
Arq Bras Cardiol ; 109(6): 550-559, 2017 Dec.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-29185614

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. OBJECTIVES: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. METHODS: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. RESULTS: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). CONCLUSION: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Asunto(s)
Válvula Aórtica/cirugía , Bloqueo Atrioventricular/cirugía , Bloqueo de Rama/cirugía , Estimulación Cardíaca Artificial/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Marcapaso Artificial/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Bloqueo Atrioventricular/fisiopatología , Brasil , Electrocardiografía , Femenino , Humanos , Masculino , Complicaciones Posoperatorias , Factores de Riesgo
10.
EuroIntervention ; 13(10): 1177-1184, 2017 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-28506936

RESUMEN

AIMS: Three-vessel and left main coronary artery disease (CAD) have important prognostic implications. Consequently, numerous risk scores have been developed to stratify patients with complex CAD. The aim of the present study was to compare the predictive performance of six risk scores for occurrence of fouryear all-cause mortality. METHODS AND RESULTS: From March 2008 to December 2012, 348 consecutive patients with complex CAD undergoing percutaneous coronary intervention (PCI) in a tertiary centre in São Paulo, Brazil, were analysed. Four-year mortality was assessed. The scores compared were: baseline SYNTAX score (SS), residual SYNTAX score (rSS), ACEF score, clinical SYNTAX score (cSS), SYNTAX revascularisation index (SRI) and SYNTAX score II (SSII). SSII had the best predictive performance, AUC 0.82, Brier score 0.10, surpassing all the other scores for long-term mortality prediction. Moreover, SSII discriminated well PCI patients in risk groups with p<0.01 for four-year all-cause mortality. The ACEF score (AUC 0.77) and the cSS (AUC 0.78) were significantly better than the SS (AUC 0.65), SRI (AUC 0.60) or the rSS (AUC 0.55). CONCLUSIONS: For patients with complex CAD treated by PCI, the combination of baseline clinical and angiographic factors provided better risk assessment. The SSII demonstrated the most precise predictive performance for long-term mortality.


Asunto(s)
Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Intervención Coronaria Percutánea/mortalidad , Anciano , Angiografía Coronaria/métodos , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Pronóstico , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Eur Heart J Cardiovasc Imaging ; 18(1): 54-61, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26928981

RESUMEN

AIMS: We sought to present a series of 13 pregnancy-associated spontaneous coronary artery dissection (P-SCAD), their angiographic and multimodal imaging findings, acute phase treatment, and outcomes. METHODS AND RESULTS: Between 2005 and 2015, 13 cases of P-SCAD were collected from a database of 11 tertiary hospitals. The mean age was 33.8 ± 3.7 years; most patients had no risk factors for coronary artery disease, and the majority were multiparous. P-SCAD occurred during the puerperium in 12 patients with a median time of 10 days. Only one patient presented with P-SCAD in the 37th week of pregnancy, and she was the only patient who died in this series. Six patients (46%) presented with ST-segment elevation acute myocardial infarction (STEMI), six (46%) presented with non-STEMI, and one presented with unstable angina; one-third of women had cardiogenic shock. In 12 patients, the dissection involved the left anterior descending or circumflex artery, and it extended to the left main coronary artery in 6 patients. Intravascular ultrasound or optical coherence tomography helped to confirm diagnosis and guide treatment in 46% of cases. Seven women were managed clinically; percutaneous coronary intervention was performed in five cases, and coronary artery bypass grafting was performed in one patient. CONCLUSION: In these 13 cases of P-SCAD, clinical presentation commonly included acute myocardial infarction and cardiogenic shock. Multivessel dissections and involvement of the left coronary artery and left main coronary artery were highly prevalent. Clinicians must be aware of angiographic appearances of P-SCAD for prompt diagnosis and management in these high-risk patients.


Asunto(s)
Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/terapia , Imagen Multimodal/métodos , Complicaciones Cardiovasculares del Embarazo/diagnóstico por imagen , Resultado del Embarazo , Enfermedades Vasculares/congénito , Adulto , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Anomalías de los Vasos Coronarios/mortalidad , Bases de Datos Factuales , Femenino , Estudios de Seguimiento , Edad Gestacional , Mortalidad Hospitalaria , Humanos , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/mortalidad , Periodo Posparto , Embarazo , Complicaciones Cardiovasculares del Embarazo/terapia , Estudios Retrospectivos , Medición de Riesgo , Muestreo , Centros de Atención Terciaria , Ultrasonografía Intervencional/métodos , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/mortalidad , Enfermedades Vasculares/terapia
13.
Catheter Cardiovasc Interv ; 89(3): 429-436, 2017 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-27468953

RESUMEN

OBJECTIVES: This study aimed to compare gender-related differences in outcomes of patients undergoing TAVI over a long-term follow-up period. BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been considered the standard therapy for patients with inoperable or high-risk symptomatic aortic stenosis. The influence of gender-related differences in outcomes of patients undergoing TAVI is currently on debate. METHODS: From January 2008 to January 2015, 819 patients (49% men) underwent TAVI and were included in a multicenter Brazilian registry. Patients were followed-up and clinical outcomes were evaluated according to the updated Valve Academic Research Consortium-2 criteria. RESULTS: Mean follow-up was 497 ± 478 days. Compared with women, men had a lower rate of major or life-threatening bleeding (12.0% vs. 20.6%; HR = 0.57 [95CI% 0.40-0.81]; P = 0.001), and major vascular complications (6% vs. 11.7%; HR = 0.50 [95CI% 0.31-0.82]; P = 0.004). At 30 days, all-cause mortality was lower in men than in women (6.5% vs. 11.5%; P = 0.013), however, cumulative all-cause mortality was similar between groups (25.9% vs. 29.7%, men and women, respectively, HR = 0.92 [95CI% 0.71-1.19]; P = 0.52) over the entire follow-up period. By adjusted Cox regression model, renal function, diabetes, peripheral artery disease, and chronic obstructive pulmonary disease (COPD) remained independently predictors of all-cause mortality. CONCLUSIONS: In this large-scale study evaluating patients undergoing TAVI, 30-day mortality was higher among women than men driven by significant higher rates of major or life-threatening bleeding and major vascular complications. However, all-cause mortality on long-term follow-up was similar between groups. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco , Disparidades en el Estado de Salud , Implantación de Prótesis de Válvulas Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Brasil , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Comorbilidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Hemodinámica , Hemorragia/etiología , Humanos , Estimación de Kaplan-Meier , Masculino , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento , Enfermedades Vasculares/etiología
14.
Catheter. cardiovasc. interv ; 89(3): 429-436, 2017.
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061861

RESUMEN

OBJECTIVES: This study aimed to compare gender-related differences in outcomes of patients undergoing TAVI over a long-term follow-up period.BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been considered the standard therapy for patients with inoperable or high-risk symptomatic aortic stenosis. The influence of gender-related differences in outcomes of patients undergoing TAVI is currently on debate.METHODS: From January 2008 to January 2015, 819 patients (49% men) underwent TAVI and were included in a multicenter Brazilian registry. Patients were followed-up and clinical outcomes were evaluated according to the updated Valve Academic Research Consortium-2 criteria. RESULTS: Mean follow-up was 497 ± 478 days. Compared with women, men had a lower rate of major or life-threatening bleeding (12.0% vs. 20.6%; HR = 0.57 [95CI% 0.40-0.81]; P = 0.001), and major vascular complications (6% vs. 11.7%; HR = 0.50 [95CI% 0.31-0.82]; P = 0.004). At 30 days, all-cause mortality was lower in men than in women (6.5% vs. 11.5%; P = 0.013), however, cumulative all-cause mortality was similar between groups (25.9% vs. 29.7%, men and women, respectively, HR = 0.92 [95CI% 0.71-1.19]; P = 0.52) over the entire follow-up period. By adjusted Cox regression model, renal function, diabetes, peripheral artery disease, and chronic obstructive pulmonary disease (COPD) remained independently predictors of all-cause mortality...


Asunto(s)
Estenosis de la Válvula Aórtica , Identidad de Género , Pacientes
15.
Eur Heart J Cardiovasc Imaging ; 18(1): 54-61, 2017. ilus, tab
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062603

RESUMEN

AIMS: We sought to present a series of 13 pregnancy-associated spontaneous coronary artery dissection (P-SCAD), their angiographic and multimodal imaging findings, acute phase treatment, and outcomes. METHODS AND RESULTS: Between 2005 and 2015, 13 cases of P-SCAD were collected from a database of 11 tertiary hospitals. The mean age was 33.8 ± 3.7 years; most patients had no risk factors for coronary artery disease, and the majority were multiparous. P-SCAD occurred during the puerperium in 12 patients with a median time of 10 days. Only one patient presented with P-SCAD in the 37th week of pregnancy, and she was the only patient who died in this series. Six patients (46%) presented with ST-segment elevation acute myocardial infarction (STEMI), six (46%) presented with non-STEMI, and one presented with unstable angina; one-third of women had cardiogenic shock. In 12 patients, the dissection involved the left anterior descending or circumflex artery, and it extended to the left main coronary artery in 6 patients. Intravascular ultrasound or optical coherence tomography helped to confirm diagnosis and guide treatment in 46% of cases. Seven women were managed clinically; percutaneous coronary intervention was performed in five cases, and coronary artery bypass grafting was performed in one patient...


Asunto(s)
Disección de la Arteria Carótida Interna , Infarto del Miocardio , Ultrasonografía Intervencional
16.
EuroIntervention ; 12(10): 1255-1262, 2016 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-27866134

RESUMEN

AIMS: We sought to compare the outcomes of low/moderate complexity patients treated with the Absorb BVS from the ABSORB EXTEND trial with patients treated with the XIENCE everolimus-eluting stent (EES), using propensity score (PS) matching of pooled data from the SPIRIT trials (SPIRIT II, SPIRIT III, SPIRIT IV) and the XIENCE V USA trial. METHODS AND RESULTS: ABSORB EXTEND was a prospective, single-arm, open-label clinical study in which 812 patients were enrolled at 56 sites. This study allowed the treatment of lesions ≤28 mm in length and with a reference vessel diameter of 2.0-3.8 mm (as assessed by online QCA). The propensity score was obtained by fitting a logistic regression model with the cohort indicator as the binary outcome and other variables as the predictor variables. At one-year clinical follow-up, there was no statistical difference between groups with regard to MACE (5.0% vs. 4.8%, p=0.83), target lesion failure (5.0% vs. 4.7%, p=0.74), ischaemia-driven target vessel revascularisation (2.3% vs. 3.0%, p=0.38) and device thrombosis (1.0% vs. 0.3%, p=0.11). Myocardial infarction was higher with Absorb (3.3% vs. 1.5%, p=0.02), at the expense of periprocedural CK-MB elevation. Independent predictors of MACE among patients receiving Absorb BVS were treatment of multivessel disease, insulin-dependent diabetes and performance of post-dilation. CONCLUSIONS: At one-year follow-up, propensity score-matched analysis demonstrated that the clinical safety and effectiveness of Absorb are comparable to those of XIENCE EES among non-complex patients treated with PCI.


Asunto(s)
Fármacos Cardiovasculares/uso terapéutico , Stents Liberadores de Fármacos , Everolimus/uso terapéutico , Inmunosupresores/uso terapéutico , Infarto del Miocardio/terapia , Implantes Absorbibles , Adulto , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/métodos , Fármacos Cardiovasculares/administración & dosificación , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Puntaje de Propensión , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
EuroIntervention ; 11(12): 1409-18, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26999681

RESUMEN

AIMS: We sought to examine the feasibility and reproducibility of a new video densitometric (VD) quantification of aortic regurgitation (AR) on aortography, and its long-term clinical impact. METHODS AND RESULTS: Using dedicated video densitometry software, AR after TAVI was quantified, and inter- and intra-observer reproducibility was investigated in 182 aortograms of the Brazilian TAVI registry. The aortograms were analysed using two software algorithms: 1) the quantitative regurgitation analysis (qRA) index interrogating the entire left ventricle (LV), and 2) a new method with the left ventricle outflow tract (LVOT) as a region of interest (ROI) (LVOT-AR). LVOT-AR was feasible in 64.8% vs. 29.7% of aortograms, compared with qRA index. Using the LVOT-AR, inter-observer variability was low (mean difference±standard deviation [SD]: 0.01±0.05, p=0.53), and the two observers' measurements were highly correlated (r=0.95, p<0.001). Patients with LVOT-AR >0.17 had a significantly higher one-year all-cause mortality risk compared with patients with LVOT-AR ≤0.17 (37.1% vs. 11.2%, p=0.0008). CONCLUSIONS: This study proposes an alternative methodology for AR assessment after TAVI by using the LVOT method (LVOT-AR) of VD angiography. The assessment of LVOT-AR is feasible, reproducible and potentially predictive of one-year mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/diagnóstico por imagen , Aortografía/métodos , Cateterismo Cardíaco/efectos adversos , Densitometría , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Algoritmos , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Área Bajo la Curva , Brasil , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Estudios de Factibilidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Curva ROC , Interpretación de Imagen Radiográfica Asistida por Computador , Sistema de Registros , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
18.
EuroIntervention ; 12(10): 1255-1262, 2016.
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062697

RESUMEN

We sought to compare the outcomes of low/moderate complexity patients treated with the Absorb BVS from the ABSORB EXTEND trial with patients treated with the XIENCE everolimus-eluting stent (EES), using propensity score (PS) matching of pooled data from the SPIRIT trials (SPIRIT II, SPIRIT III, SPIRIT IV) and the XIENCE V USA trial...


Asunto(s)
Servicio de Admisión en Hospital , Stents
19.
J Am Coll Cardiol ; 66(19): 2075-2088, 2015 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-26541917

RESUMEN

BACKGROUND: Cardiac biomarker release signifying myocardial injury post-transcatheter aortic valve replacement (TAVR) is common, yet its clinical impact within a large TAVR cohort receiving differing types of valve and procedural approaches is unknown. OBJECTIVES: This study sought to determine the incidence, clinical impact, and factors associated with cardiac biomarker elevation post TAVR. METHODS: This multicenter study included 1,131 consecutive patients undergoing TAVR with balloon-expandable (58%) or self-expandable (42%) valves. Transfemoral and transapical (TA) approaches were selected in 73.1% and 20.3% of patients, respectively. Creatine kinase-myocardial band (CK-MB) measurements were obtained at baseline and at several time points within the initial 72 h post TAVR. Echocardiography was performed at baseline and at 6- to 12-month follow-up. RESULTS: Overall, 66% of the TAVR population demonstrated some degree of myocardial injury as determined by a rise in CK-MB levels (peak value: 1.6-fold [interquartile range (IQR): 0.9 to 2.8-fold]). A TA approach and major procedural complications were independently associated with higher peak of CK-MB levels (p < 0.01 for all), which translated into impaired systolic left ventricular function at 6 to 12 months post TAVR (p < 0.01). A greater rise in CK-MB levels independently associated with an increased 30-day, late (median of 21 [IQR: 8 to 36] months) overall and cardiovascular mortality (p < 0.001 for all). Any increase in CK-MB levels was associated with poorer clinical outcomes, and there was a stepwise rise in late mortality according to the various degrees of CK-MB increase after TAVR (p < 0.001). CONCLUSIONS: Some degree of myocardial injury was detected in two-thirds of patients post TAVR, especially in those undergoing TA-TAVR or presenting with major procedural complications. A greater rise in CK-MB levels associated with greater acute and late mortality, imparting a negative impact on left ventricular function.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Daño por Reperfusión Miocárdica/etiología , Sistema de Registros , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Ecocardiografía , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Daño por Reperfusión Miocárdica/diagnóstico , Daño por Reperfusión Miocárdica/epidemiología , América del Norte/epidemiología , Estudios Retrospectivos , América del Sur/epidemiología , Factores de Tiempo
20.
Cardiovasc Ther ; 33(6): 367-71, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26352896

RESUMEN

AIMS: To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating. METHODS: This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year. RESULTS: After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups. CONCLUSIONS: The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Brasil , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA