Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cytometry ; 44(2): 133-6, 2001 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-11378864

RESUMEN

BACKGROUND: Violet laser diodes have recently become commercially available. These devices emit 5-25 mW in the range of 395-415 nm, and are available in systems that incorporate the diodes with collimating optics and regulated power supplies in housing incorporating thermoelectric coolers, which are necessary to maintain stable output. Such systems now cost several thousand dollars, but are expected to drop substantially in price. Materials and Methods A 4-mW, 397-nm violet diode system was used in a laboratory-built flow cytometer to excite fluorescence of DAPI and Hoechst dyes in permeabilized and intact cells. Forward and orthogonal light scattering were also measured. RESULTS: DNA content histograms with good precision (G(0)/G(1) coefficient of variation 1.7%) were obtained with DAPI staining; precision was lower using Hoechst 33342. Hoechst 34580, with an excitation maximum nearer 400 nm, yielded the highest fluorescence intensity, but appeared to decompose after a short time in solution. Scatter signals exhibited relatively broad distributions. CONCLUSIONS: Violet laser diodes are relatively inexpensive, compact, efficient, and quiet light sources for DNA fluorescence measurement using DAPI and Hoechst dyes; they can also excite several other fluorescent probes.


Asunto(s)
Citometría de Flujo/métodos , Rayos Láser , Núcleo Celular , ADN/análisis , Colorantes Fluorescentes , Humanos , Células Jurkat , Luz , Coloración y Etiquetado
2.
Antimicrob Agents Chemother ; 44(4): 827-34, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10722477

RESUMEN

Although flow cytometry has been used to study antibiotic effects on bacterial membrane potential (MP) and membrane permeability, flow cytometric results are not always well correlated to changes in bacterial counts. Using new, precise techniques, we simultaneously measured MP, membrane permeability, and particle counts of antibiotic-treated and untreated Staphylococcus aureus and Micrococcus luteus cells. MP was calculated from the ratio of red and green fluorescence of diethyloxacarbocyanine [DiOC(2)(3)]. A normalized permeability parameter was calculated from the ratio of far red fluorescence of the nucleic acid dye TO-PRO-3 and green DiOC(2)(3) fluorescence. Bacterial counts were calculated by the addition of polystyrene beads to the sample at a known concentration. Amoxicillin increased permeability within 45 min. At concentrations of <1 microg/ml, some organisms showed increased permeability but normal MP; this population disappeared after 4 h, while bacterial counts increased. At amoxicillin concentrations above 1 microg/ml, MP decreased irreversibly and the particle counts did not increase. Tetracycline and erythromycin caused smaller, dose- and time-dependent decreases in MP. Tetracycline concentrations of <1 microg/ml did not change permeability, while a tetracycline concentration of 4 microg/ml permeabilized 50% of the bacteria; 4 microg of erythromycin per ml permeabilized 20% of the bacteria. Streptomycin decreased MP substantially, with no effect on permeability; chloramphenicol did not change either permeability or MP. Erythromycin pretreatment of bacteria prevented streptomycin and amoxicillin effects. Flow cytometry provides a sensitive means of monitoring the dynamic cellular events that occur in bacteria exposed to antibacterial agents; however, it is probably simplistic to expect that changes in a single cellular parameter will suffice to determine the sensitivities of all species to all drugs.


Asunto(s)
Antibacterianos/farmacología , Permeabilidad de la Membrana Celular/efectos de los fármacos , Micrococcus luteus/efectos de los fármacos , Staphylococcus aureus/efectos de los fármacos , Carbocianinas , Recuento de Colonia Microbiana , Citometría de Flujo , Colorantes Fluorescentes , Ionóforos , Potenciales de la Membrana/efectos de los fármacos , Micrococcus luteus/genética , Staphylococcus aureus/crecimiento & desarrollo
3.
Cytometry ; 35(1): 55-63, 1999 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-10554181

RESUMEN

BACKGROUND: Membrane potential (MP) plays a critical role in bacterial physiology. Existing methods for MP estimation by flow cytometry are neither accurate nor precise, due in part to the heterogeneity of size of the particles analyzed. The ratio of a size- and MP-sensitive measurement, and an MP-independent, size-sensitive measurement, should provide a better estimate of MP. METHODS: Flow cytometry and spectrofluorometry were used to detect red (488 --> 600 nm) fluorescence associated with aggregates of diethyloxacarbocyanine (DiOC2(3)), which, in the monomeric state, is normally green (488 --> 530 nm) fluorescent. RESULTS: In bacteria incubated with 30 microM dye, aggregate formation increases with the magnitude of the interior-negative membrane potential. Green fluorescence from stained bacteria predominantly reflects particle size, and is relatively independent of MP, whereas red fluorescence is highly dependent on both MP and size. The ratio of red to green fluorescence provides a measure of MP that is largely independent of cell size, with a low coefficient of variation (CV). Calibration with valinomycin and potassium demonstrates that the method is accurate over the range from -50 mV through -120 mV; it also accurately tracks reversible reductions in MP produced by incubation at 4 degrees C and washing in glucose-free medium. CONCLUSIONS: The ratiometric technique for MP estimation using DiOC2(3) is substantially more accurate and precise than those previously available, and may be useful in studies of bacterial physiology and in investigations of the effects of antibiotics and other agents on microorganisms.


Asunto(s)
Carbocianinas/análisis , Escherichia coli/metabolismo , Citometría de Flujo/métodos , Colorantes Fluorescentes/análisis , Calibración , Carbocianinas/química , Carbocianinas/toxicidad , Recuento de Colonia Microbiana , Escherichia coli/citología , Escherichia coli/efectos de los fármacos , Colorantes Fluorescentes/química , Colorantes Fluorescentes/toxicidad , Potenciales de la Membrana , Espectrometría de Fluorescencia , Valinomicina/análisis
4.
Cytometry ; 33(2): 280-7, 1998 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-9773891

RESUMEN

In the development of suitable standards and calibration materials for fluorescence measurement, it becomes necessary to make accurate fluorescence measurements of these materials on flow cytometers. The results of such measurements may be affected by numerous sources of error, prominent among which are deviations of logarithmic amplifiers (log amps) from ideal response. To minimize the deleterious effects of log amps and multicolor fluorescence compensation circuitry on measurements, we built a flow cytometer with electronics incorporating high-precision peak detectors usable over a range from below 2 mV to 10 V, and we developed data acquisition software that transfers held peak values to a commercial 16-bit data acquisition system mounted in a personal computer running Windows 95. Fluorescence compensation is done in software, and transformation of the compensated data from a 16-bit linear to an 8-bit, 4-decade logarithmic scale is accomplished using a look-up table. Although dynamic range may be restricted by noise in the data acquisition system, high sensitivity can be achieved by photomultiplier tube gain adjustment, and it is likely that the use of a lower noise data acquisition system and/or digital processing of pulse information will enable operation over the full 4-decade dynamic range. Even at its current performance level, our instrument provides substantially better linearity over most of the scale than can be obtained using conventional electronics incorporating log amps; we believe this characteristic is critical for use in standards development.


Asunto(s)
Citometría de Flujo/instrumentación , Fluorescencia , Conversión Analogo-Digital , Calibración , Diseño de Equipo , Estudios de Evaluación como Asunto , Citometría de Flujo/métodos , Citometría de Flujo/normas , Colorantes Fluorescentes/análisis , Rayos Láser , Microcomputadores , Óptica y Fotónica , Ficoeritrina/análisis , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA