Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Vasc Interv Radiol ; 35(3): 349-360, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38013007

RESUMEN

PURPOSE: To compare the safety, effectiveness, and persistence rates of 0.018-inch coils with those of Amplatzer vascular plugs (AVPs; Abbott Vascular, Abbott Park, Illinois) for the treatment of pulmonary arteriovenous malformations (PAVMs) in response to a growing concern that 0.018-inch coil embolization would increase the long-term persistence rate. MATERIALS AND METHODS: This is a retrospective, single-center study of a database (2002-2020) of 633 PAVM embolizations. Complex PAVMs and those not embolized with 0.018-inch coils or plugs were excluded. PAVM embolization material was classified into 4 groups: (a) 0.018-inch nonfibered coils (NFCs), (b) 0.018-inch fibered coils (FCs), (c) NFCs and FCs, or (d) plugs. Persistence was defined as flow through the PAVM on digital subtraction angiography (DSA) or as <30% diameter reduction of the aneurysmal sac on unenhanced computed tomography (CT). Kaplan-Meier analysis and Cox regression were used to assess PAVM's persistence-free survival. RESULTS: A total of 312 PAVM embolizations with NFCs (43 PAVMs), FCs (127 PAVMs), NFCs and FCs (12 PAVMs), or plugs (130 PAVMs) in 109 patients (28% men; mean age = 49 years) were included. All PAVM embolizations were technically successful without any major adverse events. PAVM persistence-free survival rates at 10 years' follow-up were 40.8% versus 44.7% in the NFC and FC groups (P = .22) and 47.3% versus 81.0% in the 0.018-inch coil (NFC or FC) and plug groups (P < .0001), respectively. There were 0.43 (79/182) and 0.08 (10/130) re-embolization procedures per PAVM in the 0.018-inch coil and plug groups, respectively (P < .001). CONCLUSIONS: PAVM embolization with 0.018-inch coils was safe, but persistence rate with PAVM embolization was significantly higher than that with plugs, with no significant differences between FCs and NFCs.


Asunto(s)
Fístula Arteriovenosa , Malformaciones Arteriovenosas , Embolización Terapéutica , Arteria Pulmonar/anomalías , Venas Pulmonares , Venas Pulmonares/anomalías , Masculino , Humanos , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Malformaciones Arteriovenosas/diagnóstico por imagen , Malformaciones Arteriovenosas/terapia , Malformaciones Arteriovenosas/etiología , Fístula Arteriovenosa/terapia , Venas Pulmonares/diagnóstico por imagen , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos , Arteria Pulmonar/diagnóstico por imagen
2.
CVIR Endovasc ; 5(1): 2, 2022 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-34978632

RESUMEN

PURPOSE: To describe the interventional management and clinical outcome of pancreatico-duodenal arterio-venous malformations (PDAVMs). MATERIAL AND METHODS: Seven patients presenting a PDAVM (6 women, 1 male; mean age: 61) were retrospectively reviewed. Technical, clinical success and complications of embolization and surgical management of symptomatic PDAVMs were assessed. Technical success was defined as a complete occlusion of the PDAVM and clinical success as no clinical symptom or recurrence during follow-up. Patients with asymptomatic PDAVMs were followed clinically, by Doppler ultrasound and CT-angiography. RESULTS: Mean follow-up time was 69 months (15-180). Five symptomatic patients presented with upper gastrointestinal bleeding (n=3), ascites (n=1), and abdominal pain (n=1). Two patients were asymptomatic. The PDAVMs were classified as follow: Yakes I (1), IIIa (2), IIIb (3) and IV (1). Five symptomatic patients were treated with 9 embolization sessions with arterial approach (onyx®, glue, coils) in 7 and venous approach in 2 (plugs, coils, covered stents, STS foam and onyx®). Technical success of embolization was 60% (3/5). Devascularization was incomplete for 2 Yakes IIIB patients. Clinical success of embolization was estimated at 80% (4/5) as one patient required additional surgery (Whipple) because of persistent bleeding. One splenic vein thrombosis was treated successfully by mechanical thrombectomy and heparin. No recurrence occurred during follow-up. No progression was documented in asymptomatic patients. CONCLUSION: Embolization of symptomatic PDAVMs is effective and surgery should be performed in second intention. Complete devascularization is more difficult to obtain in Yakes III PDAVM.

4.
J Vasc Interv Radiol ; 32(3): 350-359.e2, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33483226

RESUMEN

PURPOSE: To assess whether angioplasty of hemodialysis access (HA) stenosis with a drug-coated balloon (DCB) would prevent restenosis in comparison with plain-balloon percutaneous transluminal angioplasty (PTA). MATERIALS AND METHODS: This prospective randomized clinical trial enrolled 120 patients with dysfunctional arteriovenous fistulae (n = 109) and grafts (n = 11), due to a ≥50% stenosis between March 2014 and April 2018. All patients underwent high-pressure balloon angioplasty and were then randomized to either DCB (n = 60) or PTA (n = 60). Patients were followed-up for 1 year, and angiography was performed 6 months after angioplasty. The primary endpoint was the late lumen loss (LLL) at 6 months. Secondary endpoints included other angiographic parameters at 6 months and HA failures, adverse event, and mortality at 12 months. Continuous variables were compared with a Student t-test, and Kaplan-Meier curves were used for freedom from HA failure and for mortality. RESULTS: LLL in the DCB and in the PTA group were 0.64 mm ± 1.20 and 1.13 mm ± 1.51, respectively (P = .082, adjusted P = .0498). DCB was associated with lower percentage stenosis (54.2% ± 19.3 vs 61.7% ± 18.2; P = .047) and binary restenosis ≥50% (56.5% vs 81.1%; P = .009) than PTA. The number of HA failures after 12 months was lower for DCB than for PTA (45% vs 66.7%; P = .017). Mortality at 12 months was 10% and 8.3% in the DCB and PTA groups, respectively (P = .75). CONCLUSIONS: Despite LLL improvement that failed to reach statistical significance, this study demonstrated decreased incidence and severity of restenosis with DCB compared with PTA to treat dysfunctional HA.


Asunto(s)
Angioplastia de Balón/instrumentación , Derivación Arteriovenosa Quirúrgica/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Oclusión de Injerto Vascular/terapia , Paclitaxel/administración & dosificación , Diálisis Renal , Dispositivos de Acceso Vascular , Anciano , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/mortalidad , Derivación Arteriovenosa Quirúrgica/mortalidad , Implantación de Prótesis Vascular/mortalidad , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/mortalidad , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Quebec , Recurrencia , Factores de Riesgo , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
5.
Can Assoc Radiol J ; 72(2): 317-323, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-32216558

RESUMEN

PURPOSE: To quantify eye lens dose in interventional radiology and assess whether neck dosimeter is a good surrogate to evaluate eye lens dosimetry. METHODS: Radiation exposure was prospectively measured in 9 interventional radiologists between May and October 2017. Standard Hp(0,07) thermoluminescent dosimeters (TLDs) were worn at the neck outside the lead apron, and 2 dedicated eye lens Hp(3) TLDs were placed just above the eyes, one midline and another at the outer edge of the left eye. Correlations between eye lens and neck TLD doses were assessed with Pearson coefficient, and linear regression was used to predict eye lens dose from neck TLD values. RESULTS: Eye lens dose without eye protection was 0.18 ± 0.11 (mean ± standard deviation; 0.08-0.41) mSv per workday and 35.3 ± 6.6 mSv (16.3-82.9) annually (200 workdays/year). Five (56%) radiologists exceeded the 20 mSv annual eye lens dose limit. Eye lens doses from left and central TLDs were 12.46 ± 3.02 and 9.29 ± 3.38 mSv, respectively (P = .027). Mean eye lens (left and central) and neck TLD doses were 10.87 ± 2.67 and 16.56 ± 5.67 mSv, respectively (P = .008). Pearson correlation coefficient between both eye lens TLD and between mean eye lens TLD and neck TLD doses were 0.91 and 0.92, respectively. Average of eye lens dose was 0.0179 + (0.5971 × neck dose). CONCLUSION: Full-time interventional radiologists are likely to suffer from deterministic radiation effects to the eye lens, especially on the left side. Neck TLD significantly overestimates eye lens dose. However, eye lens doses are highly correlated with neck doses and may be predicted from the neck TLD values.


Asunto(s)
Cristalino , Exposición Profesional/estadística & datos numéricos , Dosis de Radiación , Dosímetros de Radiación/estadística & datos numéricos , Exposición a la Radiación/estadística & datos numéricos , Radiología Intervencionista/estadística & datos numéricos , Humanos , Estudios Prospectivos , Protección Radiológica , Reproducibilidad de los Resultados
6.
J Vasc Interv Radiol ; 31(3): 444-453.e2, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31982312

RESUMEN

PURPOSE: This study evaluated the safety and efficacy of the JETi8 peripheral thrombectomy system in treating acute deep vein thrombosis (DVT). MATERIALS AND METHODS: A retrospective study was conducted in 18 consecutive patients (mean age, 41 years old [range, 15-74 years old]; 5 men and 13 women). There were 21 instances of DVTs (9 iliofemoral, 10 axillosubclavian, and 2 portal), which were treated using the JETi8 thrombectomy device between November 2016 and July 2018. Thrombus was laced with recombinant tissue plasminogen activator (r-TPA) (9.3 mg, on average; range, 2-12 mg) in 17 procedures (81%) prior to thrombectomy. Technical success was defined as restoration of antegrade flow using the JETi8 with or without additional treatment of an underlying obstructive lesion. Procedural success was defined as technical success with or without the addition of overnight catheter-directed thrombolysis (CDT) RESULTS: Mean procedure time was 83 minutes (range, 30-160 minutes), and mean thrombus reduction with the JETi8 alone was 92% (range, 60%-100%). Stent placement was required in 6 procedures (29%). Technical success using the JETi8 system alone was 76% (16 of 21 procedures), whereas 5 procedures (24%) required subsequent overnight CDT in the intensive care unit. Procedural success rate was 100% (20 of 20 procedures). Mean aspirated volume was 531 mL (range, 250-1,230 mL). The only adverse event was a subsegmental pulmonary embolism. Seven patients (33%) were discharged the same day. Recurrent thrombosis was observed in 5 patients (24%), of whom 3 were successfully treated with the JETi8 system. CONCLUSIONS: The JETi8 system may be a safe and effective option for thrombectomy of acute DVT.


Asunto(s)
Trombectomía/instrumentación , Trombosis de la Vena/terapia , Adolescente , Adulto , Anciano , Angioplastia de Balón/instrumentación , Femenino , Fibrinolíticos/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Quebec , Proteínas Recombinantes/administración & dosificación , Recurrencia , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Stents , Trombectomía/efectos adversos , Terapia Trombolítica , Factores de Tiempo , Activador de Tejido Plasminógeno/administración & dosificación , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/etiología , Trombosis de la Vena/fisiopatología , Adulto Joven
7.
Insights Imaging ; 10(1): 121, 2019 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-31853668

RESUMEN

Computed tomography (CT) and magnetic resonance imaging (MRI) play critical roles for assessing treatment response of hepatocellular carcinoma (HCC) after locoregional therapy. Interpretation is challenging because posttreatment imaging findings depend on the type of treatment, magnitude of treatment response, time interval after treatment, and other factors. To help radiologists interpret and report treatment response in a clear, simple, and standardized manner, the Liver Imaging Reporting and Data System (LI-RADS) has developed a Treatment Response (LR-TR) algorithm. Introduced in 2017, the system provides criteria to categorize response of HCC to locoregional treatment (e.g., chemical ablation, energy-based ablation, transcatheter therapy, and radiation therapy). LR-TR categories include Nonevaluable, Nonviable, Equivocal, and Viable. LR-TR does not apply to patients on systemic therapies. This article reviews the LR-TR algorithm; discusses locoregional therapies for HCC, treatment concepts, and expected posttreatment findings; and illustrates LI-RADS treatment response assessment with CT and MRI.

8.
Magn Reson Imaging ; 62: 78-86, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31247250

RESUMEN

PURPOSE: To identify quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters indicating tumor response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). MATERIALS AND METHODS: This prospective pilot study was approved by our institutional review board; written and informed consent was obtained for each participant. Patients underwent DCE-MRI examinations before and after TACE. A variable flip-angle unenhanced 3D mDixon sequence was performed for T1 mapping. A dynamic 4D mDixon sequence was performed after contrast injection for assessing dynamic signal enhancement. Nonparametric analysis was conducted on the time-intensity curves. Parametric analysis was performed on the time-concentration curves using a dual-input single-compartment model. Treatment response according to Liver Reporting and Data System (LI-RADS) v2018 was used as the reference standard. The comparisons within groups (before vs. after treatment) and between groups (nonviable vs. equivocal or viable tumor) were performed using nonparametric bootstrap taking into account the clustering effect of lesions in patients. RESULTS: Twenty-eight patients with 52 HCCs (size: 10-104 mm) were evaluated. For nonviable tumors (n = 27), time to peak increased from 62.5 ±â€¯18.2 s before to 83.3 ±â€¯12.8 s after treatment (P< 0.01). For equivocal or viable tumors (n = 25), time to peak and mean transit time significantly increased (from 54.4 ±â€¯24.1 s to 69.5 ±â€¯18.9 s, P < 0.01 and from 14.2 ±â€¯11.8 s to 33.9 ±â€¯36.8 s, P= 0.01, respectively) and the transfer constant from the extracellular and extravascular space to the central vein significantly decreased from 14.8 ±â€¯14.1 to 8.1 ±â€¯9.1 s-1 after treatment (P= 0.01). CONCLUSION: This prospective pilot DCE-MRI study showed that time to peak significantly changed after TACE treatment for both groups (nonviable tumors and equivocal or viable tumors). In our cohort, several perfusion parameters may provide an objective marker for differentiation of treatment response after TACE in HCC patients.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Quimioembolización Terapéutica , Medios de Contraste/farmacología , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Anciano , Carcinoma Hepatocelular/patología , Femenino , Humanos , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Estudios Prospectivos , Reproducibilidad de los Resultados , Venas/diagnóstico por imagen
9.
J Vasc Interv Radiol ; 30(4): 523-530, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30910174

RESUMEN

PURPOSE: To compare automated measurements of maximal diameter (Dmax) of abdominal aortic aneurysm (AAA) orthogonal to luminal or outer wall envelope centerline for endovascular repair (EVAR) follow-up. MATERIAL AND METHODS: Eighty-three consecutive patients with AAA treated by EVAR who had at least 1 computed tomography (CT) scan before and 2 CT scans after EVAR with at least 5 months' interval were included. Three-dimensional reconstruction of the AAA was achieved with dedicated segmentation software. Performances of automated calculation algorithms of Dmax perpendicular to lumen or outer wall envelope centerlines were then compared to manual measurement of Dmax on double-oblique multiplanar reconstruction (gold standard). Accuracy of automated Dmax measurements at baseline, follow-up, and progression over time was evaluated by calculation of mean error, Bland-Altman plot, and regression models. RESULTS: Disagreement in Dmax measurements between outer wall envelope algorithm and manual method was insignificant (mean error: baseline, -0.07 ± 1.66 mm, P = .7; first follow-up, 0.24 ± 1.69 mm, P = .2; last follow-up, -0.41 ± 2.74 mm, P = .17); whereas significant discrepancies were found between the luminal algorithm and the manual method (mean error: baseline, -1.24 ± 2.01 mm, P < .01; first follow-up, -1.49 ± 3.30 mm, P < .01; last follow-up, -1.78 ± 3.60 mm, P < .01). Dmax progression results were more accurate with AAA outer wall envelope algorithm compared to luminal method (P = .2). CONCLUSIONS: AAA outer wall envelope segmentation is recommended to enable automated calculation of Dmax perpendicular to its centerline during EVAR follow-up.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Angiografía por Tomografía Computarizada/métodos , Procedimientos Endovasculares , Tomografía Computarizada Multidetector/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Validación de Programas de Computación , Anciano , Anciano de 80 o más Años , Automatización , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
10.
Abdom Radiol (NY) ; 44(2): 517-528, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30167771

RESUMEN

PURPOSE: To evaluate the diagnostic performance of Liver Imaging Reporting and Data System (LI-RADS) v2017 major features, the impact of ancillary features, and categories on contrast-enhanced computed tomography (CECT) for the diagnosis of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This retrospective study included 59 patients (104 observations including 72 HCCs) with clinical suspicion of HCC undergoing CECT between 2013 and 2016. Two radiologists independently assessed major and ancillary imaging features for each liver observation and assigned a LI-RADS category based on major features only and in combination with ancillary features. The composite reference standard included pathology or imaging. Per-lesion estimates of diagnostic performance of major features, ancillary features, and LI-RADS categories were assessed by generalized estimating equation models. RESULTS: Major features (arterial phase hyperenhancement, washout, capsule, and threshold growth) respectively had a sensitivity of 86.1%, 81.6%, 20.7%, and 26.1% and specificity of 39.3%, 67.9%, 89.9%, and 85.0% for HCC. Ancillary features (ultrasound visibility as discrete nodule, subthreshold growth, and fat in mass more than adjacent liver) respectively had a sensitivity of 42.6%, 50.8%, and 15.1% and a specificity of 79.2%, 66.9%, and 96.4% for HCC. Ancillary features modified the final category in 4 of 104 observations. For HCC diagnosis, categories LR-3, LR-4, LR-5, and LR-TIV (tumor in vein) had a sensitivity of 5.3%, 29.0%, 53.7%, and 10.7%; and a specificity of 49.1%, 84.4%, 97.3%, and 96.4%, respectively. CONCLUSION: On CT, LR-5 category has near-perfect specificity for the diagnosis of HCC and ancillary features modifies the final category in few observations.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Sistemas de Información Radiológica/normas , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Estudios Transversales , Diagnóstico Diferencial , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Sistemas de Información Radiológica/estadística & datos numéricos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
11.
Med Phys ; 46(2): 789-799, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30451303

RESUMEN

PURPOSE: The purpose of this study was to demonstrate the feasibility of using a custom gradient sequence on an unmodified 3T magnetic resonance imaging (MRI) scanner to perform magnetic resonance navigation (MRN) by investigating the blood flow control method in vivo, reproducing the obtained rheology in a phantom mimicking porcine hepatic arterial anatomy, injecting magnetized microbead aggregates through an implantable catheter, and steering the aggregates across arterial bifurcations for selective tumor embolization. MATERIALS AND METHODS: In the first phase, arterial hepatic velocity was measured using cine phase-contrast imaging in seven pigs under free-flow conditions and controlled-flow conditions, whereby a balloon catheter is used to occlude arterial flow and saline is injected at different rates. Three of the seven pigs previously underwent selective lobe embolization to simulate a chemoembolization procedure. In the second phase, the measured in vivo controlled-flow velocities were approximately reproduced in a Y-shaped vascular bifurcation phantom by injecting saline at an average rate of 0.6 mL/s with a pulsatile component. Aggregates of 200-µm magnetized particles were steered toward the right or left hepatic branch using a 20-mT/m MRN gradient. The phantom was oriented at 0°, 45°, and 90° with respect to the B0 magnetic field. The steering differences between left-right gradient and baseline were calculated using Fisher's exact test. A theoretical model of the trajectory of the aggregate within the main phantom branch taking into account gravity, magnetic force, and hydrodynamic drag was also designed, solved, and validated against the experimental results to characterize the physical limitations of the method. RESULTS: At an injection rate of 0.5 mL/s, the average flow velocity decreased from 20 ± 15 to 8.4 ± 5.0 cm/s after occlusion in nonembolized pigs and from 13.6 ± 2.0 to 5.4 ± 3.0 cm/s in previously embolized pigs. The pulsatility index measured to be 1.7 ± 1.8 and 1.1 ± 0.1 for nonembolized and embolized pigs, respectively, decreased to 0.6 ± 0.4 and 0.7 ± 0.3 after occlusion. For MRN performed at each orientation, the left-right distribution of aggregates was 55%, 25%, and 75% on baseline and 100%, 100%, and 100% (P < 0.001, P = 0.003, P = 0.003) after the application of MRN, respectively. According to the theoretical model, the aggregate reaches a stable transverse position located toward the direction of the gradient at a distance equal to 5.8% of the radius away from the centerline within 0.11 s, at which point the aggregate will have transited through a longitudinal distance of 1.0 mm from its release position. CONCLUSION: In this study, we showed that the use of a balloon catheter reduces arterial hepatic flow magnitude and variation with the aim to reduce steering failures caused by fast blood flow rates and low magnetic steering forces. A mathematical model confirmed that the reduced flow rate is low enough to maximize steering ratio. After reproducing the flow rate in a vascular bifurcation phantom, we demonstrated the feasibility of MRN after injection of microparticle aggregates through a dedicated injector. This work is an important step leading to MRN-based selective embolization techniques in humans.


Asunto(s)
Embolización Terapéutica/métodos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Imanes/química , Microesferas , Animales , Estudios de Factibilidad , Porcinos
12.
Radiology ; 288(1): 118-128, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29634435

RESUMEN

Purpose To evaluate the performance of major features, ancillary features, and categories of Liver Imaging Reporting and Data System (LI-RADS) version 2014 at magnetic resonance (MR) imaging for the diagnosis of hepatocellular carcinoma (HCC). Materials and Methods This retrospective institutional review board-approved study included patients with liver MR imaging and at least one pathologically proved lesion. Between 2004 and 2016, 102 patients (275 observations including 113 HCCs) met inclusion criteria. Two radiologists independently assessed major and ancillary imaging features for each liver observation and assigned a LI-RADS category. Per-lesion estimates of diagnostic performance of major features, ancillary features, and LI-RADS categories were assessed by using generalized estimating equation models. Results Major features (arterial phase hyperenhancement, washout, capsule, and threshold growth) had a sensitivity of 88.5%, 60.6%, 32.9%, and 41.6%, and a specificity of 18.6%, 84.8%, 98.8%, and 83.2% for HCC, respectively. Ancillary features (mild-moderate T2 hyperintensity, restricted diffusion, mosaic architecture, intralesional fat, lesional fat sparing, blood products, and subthreshold growth) had a sensitivity of 62.2%, 54.8%, 9.9%, 30.9%, 23.1%, 2.8%, and 48.3%, and a specificity of 79.4%, 90.6%, 99.4%, 94.2%, 83.1%, 99.3%, and 91.4% for HCC, respectively. The LR-5 or LR-5 V categories had a per-lesion sensitivity of 50.8% and a specificity of 95.8% for HCC, respectively. The LR-4, LR-5, or LR-5 V categories (determined by using major features only vs combination of major and ancillary features) had a per-lesion sensitivity of 75.9% and 87.9% and a per-lesion specificity of 87.5% and 86.2%, respectively. Conclusion The use of ancillary features in combination with major features increases the sensitivity while preserving a high specificity for the diagnosis of HCC.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Sistemas de Información Radiológica , Estudios Transversales , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
13.
Eur J Endocrinol ; 176(2): 159-167, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27836950

RESUMEN

OBJECTIVE: Many investigators believe that basal adrenal venous sampling (AVS) should be done simultaneously, whereas others opt for sequential AVS for simplicity and reduced cost. This study aimed to evaluate the concordance of sequential and simultaneous AVS methods. DESIGN AND METHODS: Between 1989 and 2015, bilateral simultaneous sets of basal AVS were obtained twice within 5 min, in 188 consecutive patients (59 women and 129 men; mean age: 53.4 years). Selectivity was defined by adrenal-to-peripheral cortisol ratio ≥2, and lateralization was defined as an adrenal aldosterone-to-cortisol ratio ≥2, the contralateral side. Sequential AVS was simulated using right sampling at -5 min (t = -5) and left sampling at 0 min (t = 0). RESULTS: There was no significant difference in mean selectivity ratio (P = 0.12 and P = 0.42 for the right and left sides respectively) and in mean lateralization ratio (P = 0.93) between t = -5 and t = 0. Kappa for selectivity between 2 simultaneous AVS was 0.71 (95% CI: 0.60-0.82), whereas it was 0.84 (95% CI: 0.76-0.92) and 0.85 (95% CI: 0.77-0.93) between sequential and simultaneous AVS at respectively -5 min and at 0 min. Kappa for lateralization between 2 simultaneous AVS was 0.84 (95% CI: 0.75-0.93), whereas it was 0.86 (95% CI: 0.78-0.94) and 0.80 (95% CI: 0.71-0.90) between sequential AVS and simultaneous AVS at respectively -5 min at 0 min. CONCLUSIONS: Concordance between simultaneous and sequential AVS was not different than that between 2 repeated simultaneous AVS in the same patient. Therefore, a better diagnostic performance is not a good argument to select the AVS method.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Hiperaldosteronismo/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Aldosterona/metabolismo , Femenino , Humanos , Hidrocortisona/metabolismo , Vena Ilíaca , Masculino , Persona de Mediana Edad , Adulto Joven
14.
J Vasc Surg ; 63(6): 1531-40, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27021377

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the safety and efficacy of external beam radiation (EBR) in preventing restenosis after superficial femoral artery (SFA) stenting in comparison with a control group treated with SFA stenting only. METHODS: In this Institutional Review Board-approved study, patients who provided written informed consent were randomly assigned to 0 Gy or 14 Gy of EBR to the stent site 24 hours after SFA stenting. The primary end point was the angiographic binary restenosis rate 2 years after stenting. Categorical and continuous end points were respectively analyzed using logistic regression models and Wilcoxon tests. End points expressed as time to event were analyzed using a log-rank test. RESULTS: The study included 155 patients, 46 women and 109 men (mean age, 66 years; range, 45-85 years). In the 0 and 14 Gy groups, binary restenosis was present, respectively, in 44% (34/77) and 68% (52/76; P = .003) 2 years after stenting. Stent thrombosis occurred in 13% (10/78) of the 0 Gy group and in 33% (25/77) of the 14 Gy group (P = .003). Target lesion revascularization at 2 years was 26% (25/78) in the 0 Gy group and 30% (23/77) in the 14 Gy group (P = .56). There were no significant differences in total walking distances change from baseline to 2 years (46 ± 100 and 26 ± 79 m, respectively, in the 0 Gy and 14 Gy group; P = .25). There were no procedure-related deaths and no major amputations. CONCLUSIONS: A single 14 Gy dose of EBR to the SFA stenting site did not prevent in-stent restenosis.


Asunto(s)
Angioplastia de Balón/instrumentación , Braquiterapia/métodos , Arteria Femoral/efectos de la radiación , Enfermedad Arterial Periférica/terapia , Stents , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Angioplastia de Balón/efectos adversos , Braquiterapia/efectos adversos , Constricción Patológica , Supervivencia sin Enfermedad , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Quebec , Dosificación Radioterapéutica , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
Hepatology ; 64(1): 224-31, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26990687

RESUMEN

UNLABELLED: Idiopathic noncirrhotic portal hypertension is a heterogeneous group of diseases characterized by portal hypertension in the absence of cirrhosis. The efficacy and safety of transjugular intrahepatic portosystemic shunt (TIPS) in this population are unknown. The charts of patients with idiopathic noncirrhotic portal hypertension undergoing TIPS in seven centers between 2000 and 2014 were retrospectively reviewed. Forty-one patients were included. Indications for TIPS were recurrent variceal bleeding (n = 25) and refractory ascites (n = 16). Patients were categorized according to the presence (n = 27) or absence (n = 14) of significant extrahepatic comorbidities. Associated conditions were hematologic, prothrombotic, neoplastic, immune, and exposure to toxins. During follow-up (mean 27 ± 29 months), variceal rebleeding occurred in 7/25 (28%), including three with early thrombosis of the stent. Post-TIPS overt hepatic encephalopathy was present in 14 patients (34%). Eleven patients died, five due the liver disease or complications of the procedure and six because of the associated comorbidities. The procedure was complicated by hemoperitoneum in four patients (10%), which was fatal in one case. Serum creatinine (P = 0.005), ascites as indication for TIPS (P = 0.04), and the presence of significant comorbidities (P = 0.01) at the time of the procedure were associated with death. Mortality was higher in patients with significant comorbidities and creatinine ≥100 µmol/L (P < 0.001). CONCLUSION: In patients with idiopathic noncirrhotic portal hypertension who have normal kidney function or do not have severe extrahepatic conditions, TIPS is an excellent option to treat severe complications of portal hypertension. (Hepatology 2016;64:224-231).


Asunto(s)
Hipertensión Portal/terapia , Derivación Portosistémica Intrahepática Transyugular , Adulto , Europa (Continente)/epidemiología , Femenino , Humanos , Hipertensión Portal/complicaciones , Hipertensión Portal/mortalidad , Masculino , Persona de Mediana Edad , Quebec/epidemiología , Estudios Retrospectivos
16.
Eur J Radiol ; 85(1): 150-157, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26724660

RESUMEN

PURPOSE: To evaluate the sensitivity and specificity of non-enhanced chest CT to detect reperfusion after pulmonary arteriovenous malformation (PAVM) embolization. MATERIALS AND METHODS: The Institutional Review Board approved this retrospective HIPAA-compliant study and waived the need for patient consent. All consecutive patients who underwent PAVM embolization between January 2000 and April 2011 were included. Complex PAVMs and patients without available pre- and/or post-embolization CT were excluded. PAVM artery, aneurysm and vein diameters were measured on non-enhanced chest CT before and after PAVM embolization. Pulmonary angiography (PA) was the reference standard to assess PAVM reperfusion. Reperfusion detection was analyzed with receiver operating characteristic (ROC) curves according to percentage of diameter reduction cut-off. Inter-observer concordance was ascertained with intra-class correlation coefficients (ICCs). RESULTS: Out of 68 patients with PAVM embolizations, 42 (62%) had 108 PAVMs that met inclusion/exclusion criteria. Areas under the ROC curves for PAVM reperfusion detection were 0.84, 0.87, and 0.78, respectively, for PAVM artery, aneurysm and vein (p>0.05). Sensitivity varied between 51% and 56%, and specificity between 86% and 98% for the <30% diameter reduction cut-off. Sensitivity was between 98% and 100%, and specificity, between 20% and 47% for the <70% diameter reduction cut-off. ICCs for inter-observer concordance were 0.58, 0.88 and 0.68 for percentage reduction of PAVM artery, aneurysm and vein, respectively. CONCLUSION: PAVM diameter reduction cut-offs of <30% and <70%, to detect PAVM reperfusion on non-enhanced CT reported in the literature, would respectively result in low sensitivity and specificity.


Asunto(s)
Fístula Arteriovenosa/fisiopatología , Fístula Arteriovenosa/terapia , Malformaciones Arteriovenosas/fisiopatología , Malformaciones Arteriovenosas/terapia , Embolización Terapéutica , Arteria Pulmonar/anomalías , Arteria Pulmonar/fisiopatología , Venas Pulmonares/anomalías , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Angiografía , Fístula Arteriovenosa/diagnóstico , Malformaciones Arteriovenosas/diagnóstico , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Arteria Pulmonar/diagnóstico por imagen , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
17.
Int J Hepatol ; 2012: 167868, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22888442

RESUMEN

The transjugular intrahepatic portosystemic shunt (TIPS) represents a major advance in the treatment of complications of portal hypertension. Technical improvements and increased experience over the past 24 years led to improved clinical results and a better definition of the indications for TIPS. Randomized clinical trials indicate that the TIPS procedure is not a first-line therapy for variceal bleeding, but can be used when medical treatment fails, both in the acute situation or to prevent variceal rebleeding. The role of TIPS to treat refractory ascites is probably more justified to improve the quality of life rather than to improve survival, except for patients with preserved liver function. It can be helpful for hepatic hydrothorax and can reverse hepatorenal syndrome in selected cases. It is a good treatment for Budd Chiari syndrome uncontrollable by medical treatment. Careful selection of patients is mandatory before TIPS, and clinical followup is essential to detect and treat complications that may result from TIPS stenosis (which can be prevented by using covered stents) and chronic encephalopathy (which may in severe cases justify reduction or occlusion of the shunt). A multidisciplinary approach, including the resources for liver transplantation, is always required to treat these patients.

18.
J Gastroenterol Hepatol ; 27(8): 1336-40, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22554152

RESUMEN

BACKGROUND AND AIM: To evaluate hepatic hemodynamics in patients with nodular regenerative hyperplasia of the liver (NRH) with portal hypertension (PHT). METHODS: We retrospectively reviewed the charts of 24 patients referred for PHT related to biopsy-proven NRH. Hemodynamic measurements included wedged hepatic vein (WHVP) and inferior vena cava (IVCP), and, in 12 patients, portal vein pressure (PVP). Hepatic vein pressure gradient (HVPG: WHVP-IVCP) and portal vein pressure gradient (PVPG: PVP-IVCP) were calculated. RESULTS: Nodular regenerative hyperplasia was associated in 24 patients with various diseases (oxaliplatin chemotherapy, treatment with purine antagonists, post liver transplantation, hematologic and rheumatologic conditions and HIV infection). Liver function parameters were either completely normal or slightly impaired. Patients were referred for gastroesophageal varices (n = 18), and/or ascites (n = 11), and/or splenomegaly (n = 20). In patients with varices or ascites, HVPG was lower than 10 mmHg (a cut-off point for the presence of varices and/or ascites) in 15/21, suggesting a pre-sinusoidal component to their PHT confirmed by a PVP higher than 12 mmHg in 12/12 patients. The mean difference between HVPG and PVPG was 8.7 mmHg in these patients. Ten patients were treated by transjugular intrahepatic portosystemic shunt. None of them re-bled, and one presented transient hepatic encephalopathy. CONCLUSIONS: Presinusoidal PHT associated with NRH is probably related to compression of portal venules by the regenerative nodules. In patients with HTP and a HVPG < 10 mmHg, the diagnosis of NRH must be suspected and PVP measured, which is important in the management of these patients.


Asunto(s)
Hiperplasia Nodular Focal/fisiopatología , Hemodinámica , Hipertensión Portal/fisiopatología , Circulación Hepática , Regeneración Hepática , Hígado/irrigación sanguínea , Adulto , Anciano , Biopsia , Femenino , Hiperplasia Nodular Focal/diagnóstico , Venas Hepáticas/fisiopatología , Humanos , Hipertensión Portal/diagnóstico , Hipertensión Portal/cirugía , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Presión Portal , Vena Porta/fisiopatología , Derivación Portosistémica Intrahepática Transyugular , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Vena Cava Inferior/fisiopatología , Presión Venosa
19.
Int J Hepatol ; 2011: 974514, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21994880

RESUMEN

Background. Transcatheter arterial lipiodol chemoembolization (TACE) can be used in cirrhotic patients with hepatocellular carcinoma to avoid tumor progression before transplantation. Objective. To evaluate the efficacy and safety of TACE used as a bridge to liver transplantation. Methods. TACE was performed in 30 cirrhotic patients with hepatocellular carcinoma. Milan criteria were used to select patients for transplant. Patients had a good or moderately impaired liver function, no arterioportal fistulae, and a good portal perfusion. Results. 48 TACE were performed in 30 patients. Before transplantation, 4 patients were dropped off the list due to tumor extension or liver failure. Complete necrosis of the tumor was observed in 11 patients and partial necrosis in 15 patients. After transplantation, 6 patients died and tumor recurrence was observed in 5 patients with a tumor beyond Milan criteria or no response to TACE. Conclusion. TACE is useful as a bridge to liver transplantation in a selected group of cirrhotic patients with hepatocellular carcinoma. A combined therapeutic approach before surgery might improve the prognosis in these patients.

20.
J Vasc Interv Radiol ; 22(11): 1563-8, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21840226

RESUMEN

PURPOSE: To evaluate the efficacy and safety of percutaneous renal artery embolization (RAE) of iatrogenic vascular kidney injuries and the effects of RAE on renal function and arterial blood pressure (BP). MATERIALS AND METHODS: Over a 12-year period, 50 consecutive patients with severe hemorrhage after iatrogenic arterial kidney injuries underwent RAE. Technical success was defined as occlusion of the bleeding site, and clinical success was defined as complete bleeding cessation. The effects on renal function and arterial BP were assessed by comparing the estimated glomerular filtration rate (eGFR), renal function stage (National Kidney Foundation scale), systolic BP, and BP stage (European Society of Hypertension classification) before and after RAE. RESULTS: RAE was technically successful in 49 patients (98%). Two patients were lost to follow-up after RAE. Clinical success was obtained in 40 (83%), 45 (94%), and 47 patients (98%), respectively, at 24, 48, and 96 hours after RAE. Three patients (6%) had minor complications, and one patient (2%) died within 30 days after RAE. Follow-up renal function data (mean, 4 mo) were available for 33 patients (66%). No statistically significant differences in eGFR (P = .186) or renal function stage (P = .183) were apparent after RAE. Follow-up BP data (mean, 3 mo) were available for 28 patients (56%). There were no significant differences in systolic BP (P = .233) or BP stage (P = .745) after RAE. CONCLUSIONS: Embolization of iatrogenic renal artery injuries is safe and associated with high technical and clinical success rates. It is not associated with a significant worsening of renal function or increase in BP.


Asunto(s)
Presión Sanguínea , Embolización Terapéutica , Tasa de Filtración Glomerular , Hemorragia/terapia , Enfermedad Iatrogénica , Riñón/irrigación sanguínea , Riñón/fisiopatología , Arteria Renal/lesiones , Lesiones del Sistema Vascular/terapia , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Hemorragia/etiología , Hemorragia/mortalidad , Hemorragia/fisiopatología , Humanos , Modelos Lineales , Modelos Logísticos , Persona de Mediana Edad , Quebec , Arteria Renal/fisiopatología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/mortalidad , Lesiones del Sistema Vascular/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...