Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Matern Fetal Neonatal Med ; 29(8): 1200-4, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26004985

RESUMEN

OBJECTIVE: To assess if lactate measured with the Scout Lactate System is a reliable alternative to pH in intrapartum monitoring of the fetus. METHODS: A prospective study analyzing (1) the correlation between scalp lactate measured by the Scout Lactate System and the Automatic Blood Laboratory (ABL), (2) the correlation between lactate and pH measured in scalp blood and (3) the correlation between fetal scalp lactate and umbilical cord SBE. The sensitivity/specificity and positive/negative predictive values of lactate in predicting low pH were analyzed and expressed as Receiver Operating Curves (ROC). RESULTS: Lactate measured by the Scout Lactate System and the ABL correlated well (r(2)=0.85). Both lactate and pH were measured in 1009 scalp blood samples. The sensitivity and specificity of lactate ≥ 4.8 mmol/l in predicting a pH <7.20 were 0.63 and 0.85, respectively. The correlation between scalp lactate measured within 15 min prior to delivery and the umbilical cord SBE was low. CONCLUSION: Monitoring non-reassuring deliveries with scalp lactate instead of pH would have resulted in more (155 instead of 56) instrumental deliveries with no decrease in newborns with severe metabolic acidosis.


Asunto(s)
Sangre Fetal , Monitoreo Fetal/métodos , Concentración de Iones de Hidrógeno , Trabajo de Parto , Ácido Láctico/sangre , Cuero Cabelludo , Acidosis/diagnóstico , Parto Obstétrico , Femenino , Hipoxia Fetal/diagnóstico , Humanos , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad
2.
Acta Obstet Gynecol Scand ; 90(3): 253-7, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21306311

RESUMEN

OBJECTIVE: To investigate the degree of fetomaternal hemorrhage (FMH) caused by elective cesarean section. DESIGN: Descriptive study. SETTINGS: University Hospitals in Copenhagen, Denmark. POPULATION: Women scheduled for elective cesarean section, in the period September 2007 to January 2009, at the Department of Gynecology and Obstetrics, Hvidovre Hospital, University of Copenhagen, Denmark. METHODS: Two maternal blood samples were taken, the first before cesarean section and the second immediately after. Both samples were analyzed at the Blood Bank, Rigshospitalet, Copenhagen, for the presence of fetal red blood cells (fRBCs) using flow cytometry. FMH associated with cesarean section was defined as the difference between the volumes of fRBCs in the two samples. MAIN OUTCOME MEASURES: The frequency and volume of FMH caused by elective cesarean section. RESULTS: 207 women were included in the study. FMH was detected in 38 cases (18.4%). Of these, 22 women (10.6%) had FMH of less than 1 ml fRBCs, 13 women (6.3%) had FMH between 1 and 4 ml fRBCs, and three women (1.4%) had FMH above 4 ml fRBCs. CONCLUSIONS: We found no evidence for recommending general screening for FMH in connection with elective cesarean section, provided guidelines such as the current Danish guidelines for Rhesus prophylaxis are followed.


Asunto(s)
Cesárea/estadística & datos numéricos , Procedimientos Quirúrgicos Electivos/estadística & datos numéricos , Transfusión Fetomaterna/epidemiología , Resultado del Embarazo/epidemiología , Salud de la Mujer , Adulto , Causalidad , Comorbilidad , Dinamarca/epidemiología , Femenino , Humanos , Complicaciones del Trabajo de Parto/epidemiología , Embarazo , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...