1.
Phys Med ; 118: 103201, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38199179

RESUMEN

PURPOSE: This work aims at studying the sensitivity of a miniaturized Tissue-Equivalent Proportional Counter to variations of beam quality in clinical radiation fields, to further investigate its performances as radiation quality monitor. METHODS: Measurements were taken at the CATANA facility (INFN-LNS, Catania, Italy), in a monoenergetic and an energy-modulated proton beam with the same initial energy of 62 MeV. PMMA layers were placed in front of the detector to measure at different depths along the depth-dose profile. The frequency- and dose-mean lineal energy were compared to the track- and dose-averaged LET calculated by Monte Carlo simulations. A microdosimetric evaluation of the Relative Biological Effectiveness (RBE) was performed and compared with cell survival experiments. RESULTS: Microdosimetric distributions measured at identical depths in the two beams show spectral differences reflecting their different radiation quality. Discrepancies are most evident at depths corresponding to the Spread-Out Bragg Peak, while spectra at the entrance and in the dose fall-off regions are similar. This can be explained by the different energy components that compose the pristine and spread-out peaks at each depth. The trend of microdosimetric mean values matches that of calculated LET averages along the entire penetration depth, and the microdosimetric estimation of RBE is consistent with radiobiological data not only at 2 Gy but also at lower dose levels, such as those absorbed by healthy tissues. CONCLUSIONS: The mini-TEPC is sensitive to differences in radiation quality resulting from different modulations of the proton beam, confirming its potential for beam quality monitoring in proton therapy.


Asunto(s)
Terapia de Protones , Monitoreo de Radiación , Protones , Radiometría/métodos , Efectividad Biológica Relativa , Método de Montecarlo
2.
Radiat Prot Dosimetry ; 199(15-16): 1968-1972, 2023 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819306

RESUMEN

In proton therapy, most treatment planning systems (TPS) use a fixed relative biological effectiveness (RBE) of 1.1 all along the depth-dose profile. Innovative TPS are now investigated considering the variability of RBE with radiation quality. New TPS need an experimental verification in the quality assurance (QA) routine in clinics, but RBE data are usually obtained with radiobiological measurements that are time consuming and not suitable for daily QA. Microdosimetry is a useful tool based on physical measurements which can monitor the radiation quality. Several microdosimeters are available in different research institutions, which could potentially be used for the QA in TPS. In this study, the response functions of five detectors in the same 62-MeV proton Spread Out Bragg Peak is compared in terms of spectral distributions and their average values and microdosimetric RBE. Their different response function has been commented and must be considered in the clinical practice.


Asunto(s)
Terapia de Protones , Protones , Radiometría , Efectividad Biológica Relativa
3.
Phys Med Biol ; 67(16)2022 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-35679848

RESUMEN

Objective.In the present hadrontherapy scenario, there is a growing interest in exploring the capabilities of different ion species other than protons and carbons. The possibility of using different ions paves the way for new radiotherapy approaches, such as the multi-ions treatment, where radiation could vary according to target volume, shape, depth and histologic characteristics of the tumor. For these reasons, in this paper, the study and understanding of biological-relevant quantities was extended for the case of4He ion.Approach.Geant4 Monte Carlo based algorithms for dose- and track-averaged LET (Linear Energy Transfer) calculations, were validated for4He ions and for the case of a mixed field characterised by the presence of secondary ions from both target and projectile fragmentation. The simulated dose and track averaged LETs were compared with the corresponding dose and frequency mean values of the lineal energy,yD¯andy¯F, derived from experimental microdosimetric spectra. Two microdosimetric experimental campaigns were carried out at the Italian eye proton therapy facility of the Laboratori Nazionali del Sud of Istituto Nazionale di Fisica Nucleare (INFN-LNS, Catania, I) using two different microdosimeters: the MicroPlus probe and the nano-TEPC (Tissue Equivalent Proportional Counter).Main results.A good agreement ofL¯dTotalandL¯tTotalwithy¯Dandy¯Texperimentally measured with both microdosimetric detectors MicroPlus and nano-TEPC in two configurations: full energy and modulated4He ion beam, was found.Significance.The results of this study certify the use of a very effective tool for the precise calculation of LET, given by a Monte Carlo approach which has the advantage of allowing detailed simulation and tracking of nuclear interactions, even in complex clinical scenarios.


Asunto(s)
Transferencia Lineal de Energía , Radiometría , Algoritmos , Iones , Método de Montecarlo , Protones , Radiometría/métodos
4.
Phys Med ; 89: 226-231, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34425513

RESUMEN

The aim of the NEPTUNE (Nuclear process-driven Enhancement of Proton Therapy UNravEled) project is to investigate in detail both the physical and radiobiological phenomena that could justify an increase of the proton-induced cytogenetic effects in cells irradiated in presence of an agent containing natural boron. In this work, a double-stage silicon telescope coupled to different boron converters was irradiated at the CATANA proton therapy facility (INFN-LNS) for studying the proton boron fusion and the neutron boron capture reactions by discriminating secondary particles from primary protons. Different boron targets were developed by depositing boric acid, enriched with a higher than 99% content of 10B or 11B, on a 50 µm thick PolyMethilMetacrylate (PMMA) substrate. The 10B target allows to evaluate the contribution of lithium and alpha particles produced by the boron neutron capture reaction triggered by secondary thermal neutrons, while the 11B target is exploited for studying the effect of the p + 11B → 3α nuclear reaction directly triggered by primary protons. Experimental results clearly show the presence of alpha particles from both the reactions. The silicon telescope is capable of discriminating, by means of the so-called "scatter plots", the contribution of alpha particles originated by thermal neutrons on 10B with respect to the ones produced by protons impinging on 11B. Although a reliable quantitative study of the alpha production rate has not been achieved yet, this work demonstrates that low energy and, therefore, high-LET particles from both the reactions can be measured.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Terapia de Protones , Boro , Neutrones , Protones
5.
Med Phys ; 48(1): 19-56, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32392626

RESUMEN

BACKGROUND: Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro- and nanodosimetry, imaging, radiation protection, and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. AIMS: To respond to these needs, we developed G4-Med, a benchmarking and regression testing system of Geant4 for medical physics. MATERIALS AND METHODS: G4-Med currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the prebuilt Geant4 physics lists are tested. The tests included in G4-Med are executed on the CERN computing infrastructure via the use of the geant-val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. RESULTS: This paper describes the tests included in G4-Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. DISCUSSION: Our results indicate that the Geant4 electromagnetic physics constructor G4EmStandardPhysics_option4 gives a good agreement with the reference data for all the tests. The QGSP_BIC_HP physics list provided an overall adequate description of the physics involved in hadron therapy, including proton and carbon ion therapy. New tests should be included in the next stage of the project to extend the benchmarking to other physical quantities and application scenarios of interest for medical physics. CONCLUSION: The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.


Asunto(s)
Benchmarking , Física , Radiometría , Simulación por Computador , Método de Montecarlo
6.
Phys Med Biol ; 65(23): 235043, 2020 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-33263314

RESUMEN

We exploited the power of the Geant4 Monte Carlo toolkit to study and validate new approaches for the averaged linear energy transfer (LET) calculation in 62 MeV clinical proton beams. The definitions of the averaged LET dose and LET track were extended, so as to fully account for the contribution of secondary particles generated by target fragmentation, thereby leading to a more general formulation of the LET total. Moreover, in the proposed new strategies for the LET calculation, we minimised the dependencies in respect to the transport parameters adopted during the Monte Carlo simulations (such as the production cut of secondary particles, voxel size and the maximum steplength). The new proposed approach was compared against microdosimetric experimental spectra of clinical proton beams, acquired at the Italian eye proton therapy facility of the Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare (INFN-LNS, Catania, I) from two different detectors: a mini-tissue equivalent proportional chamber (TEPC), developed at the Legnaro National Laboratories of the National Institute for Nuclear Physics (LNL-INFN) and a silicon-on-insulator (SOI) microdosimeter with 3D sensitive volumes developed by the Centre for Medical Radiation Physics of Wollongong University (CMRP-UoW). A significant increase of the LET in the entrance region of the spread out Bragg peak (SOBP) was observed, when the contribution of the generated secondary particles was included in the calculation. This was consistent with the experimental results obtained.


Asunto(s)
Algoritmos , Transferencia Lineal de Energía , Método de Montecarlo , Terapia de Protones , Dosis de Radiación , Humanos , Dosificación Radioterapéutica
7.
Phys Med Biol ; 65(24): 245018, 2020 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-33086208

RESUMEN

Proton beams are widely used worldwide to treat localized tumours, the lower entrance dose and no exit dose, thus sparing surrounding normal tissues, being the main advantage of this treatment modality compared to conventional photon techniques. Clinical proton beam therapy treatment planning is based on the use of a general relative biological effectiveness (RBE) of 1.1 along the whole beam penetration depth, without taking into account the documented increase in RBE at the end of the depth dose profile, in the Bragg peak and beyond. However, an inaccurate estimation of the RBE can cause both underdose or overdose, in particular it can cause the unfavourable situation of underdosing the tumour and overdosing the normal tissue just beyond the tumour, which limits the treatment success and increases the risk of complications. In view of a more precise dose delivery that takes into account the variation of RBE, experimental microdosimetry offers valuable tools for the quality assurance of LET or RBE-based treatment planning systems. The purpose of this work is to compare the response of two different microdosimetry systems: the mini-TEPC and the MicroPlus-Bridge detector. Microdosimetric spectra were measured across the 62 MeV spread out Bragg peak of CATANA with the mini-TEPC and with the Bridge microdosimeter. The frequency and dose distributions of lineal energy were compared and the different contributions to the spectra were analysed, discussing the effects of different site sizes and chord length distributions. The shape of the lineal energy distributions measured with the two detectors are markedly different, due to the different water-equivalent sizes of the sensitive volumes: 0.85 µm for the TEPC and 17.3 µm for the silicon detector. When the Loncol's biological weighting function is applied to calculate the microdosimetric assessment of the RBE, both detectors lead to results that are consistent with biological survival data for glioma U87 cells. Both the mini-TEPC and the MicroPlus-Bridge detector can be used to assess the RBE variation of a 62 MeV modulated proton beam along its penetration depth. The microdosimetric assessment of the RBE based on the Loncol's weighting function is in good agreement with radiobiological results when the 10% biological uncertainty is taken into account.


Asunto(s)
Terapia de Protones , Radiometría , Efectividad Biológica Relativa , Humanos , Silicio
8.
Med Phys ; 47(11): 5791-5801, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32974938

RESUMEN

PURPOSE: The purpose of this study was to investigate for the first time the performance of a synthetic single crystal diamond detector for the microdosimetric characterization of clinical 62 MeV ocular therapy proton beams. METHODS: A novel diamond microdosimeter with a well-defined sensitive volume was fabricated and tested with a monoenergetic and spread-out Bragg peak (SOBP) of the CATANA therapeutic proton beam in Catania, Italy. The whole sensitive volume of the detector has an active planar-sectional area of 100 µm × 100 µm and a thickness of approximately 6.3 um. Microdosimetric measurements were performed at several water equivalent depths, corresponding to positions of clinical relevance. From the measured spectra, microdosimetric quantities such as the frequency mean lineal energy ( y ¯ F ), dose mean lineal energy ( y ¯ D ) as well as microdosimetric relative biological effectiveness (RBEµ ) values were derived for each depth along both a pristine Bragg curve and SOBP. Finally, Geant4 Monte Carlo simulations were performed modeling the detector geometry and CATANA beamline in order to calculate the average linear energy transfer (LET) values in the diamond active layer and water. RESULTS: The microdosimetric spectra acquired by the diamond microdosimeter show different shapes as a function of the water equivalent depths. No spectral distortion, due to pile-up events and polarization effects, was observed. The experimental spectra have a very low detection threshold due to the electronic noise during the irradiation of about 1 keV/µm. The y ¯ F and y ¯ D values were in agreement with expected trends, showing a sharp increase in mean lineal energy at the distal edge of the Bragg peak. In addition, a good agreement between the mean lineal energy values and the calculated average LET ones was also observed. Finally, the RBE values evaluated with the diamond microdosimeter were in excellent agreement with those obtained with a mini tissue equivalent proportional counter as well as with radiobiological measurements in the same proton beam field. CONCLUSIONS: The microdosimetric performance of the tested synthetic single crystal diamond microdosimeter clearly indicates its suitability for quality assurance in clinical proton therapy beam.


Asunto(s)
Diamante , Terapia de Protones , Transferencia Lineal de Energía , Método de Montecarlo , Protones , Radiometría , Efectividad Biológica Relativa
9.
Phys Med ; 70: 133-138, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32014630

RESUMEN

PURPOSE: The main purpose of this work is the inter-comparison between different devices devoted to the transversal dose profile recostruction for daily QA tests in proton therapy. METHODS: The results obtained with the EBT3 radiochromic films, used as a reference, and other common quality control devices, have been compared with those obtained with a beam profiling system developed at the "Laboratori Nazionali del Sud" of Italian Institute for Nuclear Physics (INFN-LNS, Catania, Italy). It consists of a plastic scintillator screen (thickness 1 mm), mounted perpendicularly to the beam axis and coupled with a highly sensitive CCD detector in a light-tight box. RESULTS AND CONCLUSION: The tests, carried out both at the INFN-LNS and Trento Proton Therapy Center facilities, show, in general, a good agreement between the different detectors. The beam profiling system, in particular, appears to be a promising quality control device for 2-D relative dosimetry, because of its linear response in a dose rate range useful for proton therapy treatments, its high spatial resolution and its short acquisition and processing time.


Asunto(s)
Terapia de Protones/instrumentación , Protones , Radiometría/instrumentación , Conteo por Cintilación/instrumentación , Calibración , Diseño de Equipo , Humanos , Fantasmas de Imagen , Plásticos/química , Garantía de la Calidad de Atención de Salud , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Terapia Asistida por Computador/métodos
10.
Phys Med ; 68: 83-87, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31765885

RESUMEN

PURPOSE: To perform the first dosimetric intercomparison for proton beams in Italy using ionization chambers, according to the IAEA TRS-398 code of practice. METHODS: Measurement sites included: National Center for Oncological Hadron Therapy (CNAO, Pavia), Center for Proton Therapy (CTP, Trento) and Center for Hadron Therapy and for advanced Nuclear Applications (CATANA, Catania). For comparison we also included a 6 MV photon beam produced at Istituti Clinici Scientifici Maugeri (ICSM, Pavia). For proton beams, both single pseudo-monoenergetic layers (in order to obtain a planned dose of 2 Gy at the reference depth of 2 cm in a water phantom) and Spread-out Bragg peaks (SOBP) have been delivered. Measurements were performed with a PTW Farmer 30010-1 and a PTW Advanced Markus type 34,045 ionization chamber. RESULTS: Data obtained at CATANA, CNAO and CPT in terms of absorbed dose to water depth show good consistency within the experimental uncertainties, with a weighted mean of 1.99 ± 0.01 Gy and a standard error of 0.003 Gy, with reference to a nominal dose of 2 Gy as designed by the treatment planning system. CONCLUSIONS: The results showed a standard deviation of less than 1% for single layer and SOBP beams, for all chambers and a percent deviation less than 1.5% for single layer measurements. The weighted means of the absorbed doses for clinical proton beams (118.19 MeV and 173.61 MeV) are consistent within less than 1%. These results agree within the 1.5% difference considered acceptable for national dose intercomparison.


Asunto(s)
Terapia de Protones , Dosis de Radiación , Radiometría/instrumentación , Italia , Dosificación Radioterapéutica
11.
Phys Med ; 64: 114-122, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31515010

RESUMEN

A new mini-TEPC with cylindrical sensitive volume of 0.9 mm in diameter and height, and with external diameter of 2.7 mm, has been developed to work without gas flow. With such a mini counter we have measured the physical quality of the 62 MeV therapeutic proton beam of CATANA (Catania, Italy). Measurements were performed at six precise positions along the Spread-Out Bragg Peak (SOBP): 1.4, 19.4, 24.6, 29.0, 29.7 and 30.8 mm, corresponding to positions of clinical relevance (entrance, proximal, central, and distal-edge of the SOBP) or of high lineal energy transfer (LET) increment (distal-dose drop off). Without refilling the microdosimeter with new gas, the measurements were repeated at the same positions 4 months later, in order to study the stability of the response in sealed-mode operation. From the microdosimetric spectra the frequency-mean lineal energy y-F and the dose-mean lineal energy y-D were derived and compared with average LET values calculated by means of Geant4 simulations. The comparison points out, in particular, a good agreement between microdosimetric y-D and the total dose-average LET¯d, which is the average LET of the mixed radiation field, including the contribution by nuclear reactions.


Asunto(s)
Microtecnología/instrumentación , Protones , Radiometría/instrumentación , Transferencia Lineal de Energía , Método de Montecarlo
12.
Rev Sci Instrum ; 90(8): 083303, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31472608

RESUMEN

The Time-of-Flight (TOF) technique coupled with semiconductorlike detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereby presented and discussed. The proposed method takes into account the detector's working principle, through the accurate calculation of the energy loss in the detector active layer, using Monte Carlo simulations. The analysis method was validated against well-established diagnostics, such as the Thomson parabola spectrometer, during an experimental campaign carried out at the Rutherford Appleton Laboratory (UK) with the high-energy laser-driven protons accelerated by the VULCAN Petawatt laser.

13.
Phys Med ; 58: 72-80, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30824153

RESUMEN

PURPOSE: The Geant4 Monte Carlo simulation toolkit was used to reproduce radiobiological parameters measured by irradiating three different cancerous cell lines with monochromatic and clinical proton beams. METHODS: The experimental set-up adopted for irradiations was fully simulated with a dedicated open-source Geant4 application. Cells survival fractions was calculated coupling the Geant4 simulations with two analytical radiobiological models: one based on the LEM (Local Effect Model) approach and the other on a semi-empirical parameterisation. Results was evaluated and compared with experimental data. RESULTS AND CONCLUSIONS: The results demonstrated the Geant4 ability to reproduce radiobiological quantities for different cell lines.


Asunto(s)
Método de Montecarlo , Terapia de Protones , Línea Celular Tumoral , Humanos , Radiobiología , Dosificación Radioterapéutica , Reproducibilidad de los Resultados
14.
Radiat Prot Dosimetry ; 183(1-2): 177-181, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30535177

RESUMEN

The tissue-equivalent proportional counter (TEPC) is the most accurate device for measuring the microdosimetric properties of a particle beam but, since the lower operation limit of common TEPCs is ~0.3 µm, no detailed information on the track structure of the impinging particles can be obtained. The pattern of particle interactions at the nanometric level is measured directly by only three different nanodosimeters worldwide: practical instruments are not yet available. In order to partially fill the gap between microdosimetry and track-nanodosimetry, a low-pressure avalanche-confinement TEPC was designed and constructed for simulating tissue-equivalent sites down to the nanometric region. The present paper aims at describing the response of this TEPC in the range 0.3 µm-25 nm to a 62 MeV/n 4He ion beam. The experimental results, for depths near the Bragg peak, show good agreement with FLUKA simulations and suggest that, for smaller depths, the distribution is highly influenced by secondary electrons.


Asunto(s)
Helio/química , Nanotecnología , Radiometría/instrumentación , Simulación por Computador , Diseño de Equipo , Modelos Teóricos
15.
Radiat Prot Dosimetry ; 183(1-2): 274-279, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30535406

RESUMEN

The recent worldwide spread of Proton Therapy centers paves the way to new opportunities for basic and applied research related to the use of accelerated proton beams. Clinical centers make use of proton beam energies up to about 230 MeV. This represents an interesting energy range for a large spectrum of applications, including detector testing, radiation shielding and space research. Additionally, radiobiology research might benefit for a larger availability of proton beams, especially in those centers where a room dedicated to research activities also exists. Here, we describe the initial activities for the setup of a radiobiology irradiation facility at the Trento Proton Therapy Center. Data referring to the characterization of the beam in air are essential to that purpose and will be presented. A basic setup for large field irradiation will be also proposed, which is needed for the majority of in vitro and in vivo radiobiology experiments.


Asunto(s)
Terapia de Protones , Radiobiología/instrumentación , Diseño de Equipo , Arquitectura y Construcción de Instituciones de Salud , Italia , Radiometría , Dispersión de Radiación
16.
Phys Med ; 54: 166-172, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30076107

RESUMEN

The main purpose of this paper is to quantitatively study the possibility of delivering dose distributions of clinical relevance with laser-driven proton beams. A Monte Carlo application has been developed with the Geant4 toolkit, simulating the ELIMED (MEDical and multidisciplinary application at ELI-Beamlines) transport and dosimetry beam line which is being currently installed at the ELI-Beamlines in Prague (CZ). The beam line will be used to perform irradiations for multidisciplinary studies, with the purpose of demonstrating the possible use of optically accelerated ion beams for therapeutic purposes. The ELIMED Geant4-based application, already validated against reference transport codes, accurately simulates each single element of the beam line, necessary to collect the accelerated beams and to select them in energy. Transversal dose distributions at the irradiation point have been studied and optimized to try to quantitatively answer the question if such kind of beam lines, and specifically the systems developed for ELIMED in Prague, will be actually able to transport ion beams not only for multidisciplinary applications, such as pitcher-catcher nuclear reactions (e.g. neutrons), PIXE analysis for cultural heritage and space radiation, but also for delivering dose patterns of clinical relevance in a future perspective of possible medical applications.


Asunto(s)
Rayos Láser , Método de Montecarlo , Aceleradores de Partículas , Terapia de Protones/instrumentación , Dosis de Radiación , Radiometría , Dosificación Radioterapéutica
17.
Phys Med ; 54: 173-178, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30037452

RESUMEN

Preclinical studies represent an important step towards a deep understanding of the biological response to ionizing radiations. The effectiveness of proton therapy is higher than photons and, for clinical purposes, a fixed value of 1.1 is used for the relative biological effectiveness (RBE) of protons considered 1.1. Recent in vitro studies have reported that the RBE along the spread-out Bragg peak (SOBP) is not constant and, in particular, the RBE value increases on the distal part of SOBP. The present work has been carried-out in the perspective of a preclinical hadrontherapy facility at LNS-INFN and was focused on the experimental preparation of an in vivo study concerning the RBE variation along the SOBP. The main purpose of this work was to determine, using GEANT4-based Monte Carlo simulations, the best configuration for small animal treatments. The developed GEANT4 application simulates the proton-therapy beam line of LNS-INFN (CATANA facility) and allows to import the DICOM-CT images as targets. The RBE will be evaluated using a deterministic radiation damage like myelopathy as end-point. In fact, the dose at which the 50% of animals will show the myelopathy is supposed to be LET-dependent. In this work, we studied different treatment configurations in order to choose the best two that maximize the LET difference reducing as much as possible the dose released to healthy tissue. The results will be useful to plan hadrontherapy treatments for preclinical in vivo studies and, in particular, for the future in vivo RBE studies.


Asunto(s)
Método de Montecarlo , Terapia de Protones/métodos , Efectividad Biológica Relativa , Animales , Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Terapia de Protones/efectos adversos , Terapia de Protones/instrumentación
18.
Sci Rep ; 8(1): 1141, 2018 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-29348437

RESUMEN

Protontherapy is hadrontherapy's fastest-growing modality and a pillar in the battle against cancer. Hadrontherapy's superiority lies in its inverted depth-dose profile, hence tumour-confined irradiation. Protons, however, lack distinct radiobiological advantages over photons or electrons. Higher LET (Linear Energy Transfer) 12C-ions can overcome cancer radioresistance: DNA lesion complexity increases with LET, resulting in efficient cell killing, i.e. higher Relative Biological Effectiveness (RBE). However, economic and radiobiological issues hamper 12C-ion clinical amenability. Thus, enhancing proton RBE is desirable. To this end, we exploited the p + 11B → 3α reaction to generate high-LET alpha particles with a clinical proton beam. To maximize the reaction rate, we used sodium borocaptate (BSH) with natural boron content. Boron-Neutron Capture Therapy (BNCT) uses 10B-enriched BSH for neutron irradiation-triggered alpha particles. We recorded significantly increased cellular lethality and chromosome aberration complexity. A strategy combining protontherapy's ballistic precision with the higher RBE promised by BNCT and 12C-ion therapy is thus demonstrated.


Asunto(s)
Terapia por Captura de Neutrón de Boro/métodos , Boro/uso terapéutico , Terapia Combinada/métodos , Neutrones , Neoplasias de la Próstata/radioterapia , Terapia de Protones , Terapia de Protones/métodos , Partículas alfa/uso terapéutico , Animales , Borohidruros/química , Boro/química , Terapia por Captura de Neutrón de Boro/instrumentación , Isótopos de Carbono/química , Muerte Celular/efectos de la radiación , Línea Celular Tumoral , Aberraciones Cromosómicas/efectos de la radiación , Terapia Combinada/instrumentación , Ciclotrones , Daño del ADN , ADN de Neoplasias/genética , ADN de Neoplasias/metabolismo , ADN de Neoplasias/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Colorantes Fluorescentes/química , Humanos , Cariotipificación , Transferencia Lineal de Energía , Masculino , Neoplasias de la Próstata/patología , Terapia de Protones/instrumentación , Efectividad Biológica Relativa , Compuestos de Sulfhidrilo/química