Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Virol Methods ; 300: 114354, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34774617

RESUMEN

BACKGROUND: The cross-contamination of cell lines in culture is a persistent problem. Genetically modified L20B (Mouse) and RD (Human Rhabdomyosarcoma) cell lines are commonly used in poliovirus research, surveillance, and diagnostics. Cross-contamination between these cell lines leads to unreproducible results and unreliable surveillance data, negatively affecting public health. The gold standard method for cell authentication is Short Tandem Repeats analysis, which is time-consuming and expensive. The disadvantage of STR is limited detection of interspecies contamination. METHODS: This assay targets the mitochondrial cytochrome c oxidase subunit I (MTCO1) gene, a highly conserved and emergent DNA barcode region for detection of cross-contamination in RD and L20B cell lines. The MagNA Pure Compact instrument and ABI 7500 Fast Dx Real-time PCR systems were used for DNA extraction and to perform real-time PCR respectively. RESULTS: The newly developed assay is very sensitive with a limit of detection of 100 RD cells/1 million L20B/mL. The amplification efficiency and R2-value were 102.26% and 0.9969 respectively. We evaluated specificity of the assay with five human and four mouse cell lines, as well as monkey and rat cell lines. The assay showed no cross-reactivity with genomic DNA from human, mouse, rat, or monkey cell lines. The analytical sensitivity was also evaluated by spiking varying amounts of RD cells (0.001% - 10%) into L20B cells. There was no difference in CT values when running single-plex or duplex PCR reactions with similar experimental conditions. CONCLUSIONS: We have developed and validated a TaqMan real-time PCR assay, a sensitive method for the detection of cross-contamination of RD and L20B cell lines.


Asunto(s)
Poliovirus , Animales , Línea Celular , Haplorrinos/genética , Humanos , Ratones , Técnicas de Amplificación de Ácido Nucleico , Poliovirus/genética , Ratas , Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad
2.
PLoS One ; 16(12): e0260487, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34910739

RESUMEN

At the start of the COVID-19 pandemic, the Centers for Disease Control and Prevention (CDC) designed, manufactured, and distributed the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel for SARS-CoV-2 detection. The diagnostic panel targeted three viral nucleocapsid gene loci (N1, N2, and N3 primers and probes) to maximize sensitivity and to provide redundancy for virus detection if mutations occurred. After the first distribution of the diagnostic panel, state public health laboratories reported fluorescent signal in the absence of viral template (false-positive reactivity) for the N3 component and to a lesser extent for N1. This report describes the findings of an internal investigation conducted by the CDC to identify the cause(s) of the N1 and N3 false-positive reactivity. For N1, results demonstrate that contamination with a synthetic template, that occurred while the "bulk" manufactured materials were located in a research lab for quality assessment, was the cause of false reactivity in the first lot. Base pairing between the 3' end of the N3 probe and the 3' end of the N3 reverse primer led to amplification of duplex and larger molecules resulting in false reactivity in the N3 assay component. We conclude that flaws in both assay design and handling of the "bulk" material, caused the problems with the first lot of the 2019-nCoV Real-Time RT-PCR Diagnostic Panel. In addition, within this study, we found that the age of the examined diagnostic panel reagents increases the frequency of false positive results for N3. We discuss these findings in the context of improvements to quality control, quality assurance, and assay validation practices that have since been improved at the CDC.


Asunto(s)
COVID-19 , Cartilla de ADN , Reacciones Falso Positivas , Humanos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2
3.
Sci Rep ; 11(1): 9682, 2021 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-33958613

RESUMEN

The need for high-affinity, SARS-CoV-2-specific monoclonal antibodies (mAbs) is critical in the face of the global COVID-19 pandemic, as such reagents can have important diagnostic, research, and therapeutic applications. Of greatest interest is the ~ 300 amino acid receptor binding domain (RBD) within the S1 subunit of the spike protein because of its key interaction with the human angiotensin converting enzyme 2 (hACE2) receptor present on many cell types, especially lung epithelial cells. We report here the development and functional characterization of 29 nM-affinity mouse SARS-CoV-2 mAbs created by an accelerated immunization and hybridoma screening process. Differing functions, including binding of diverse protein epitopes, viral neutralization, impact on RBD-hACE2 binding, and immunohistochemical staining of infected lung tissue, were correlated with variable gene usage and sequence.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , COVID-19/inmunología , SARS-CoV-2/inmunología , Animales , COVID-19/diagnóstico , Prueba Serológica para COVID-19 , Epítopos/inmunología , Femenino , Humanos , Inmunización , Ratones , Ratones Endogámicos BALB C , Modelos Moleculares , SARS-CoV-2/aislamiento & purificación , Glicoproteína de la Espiga del Coronavirus/inmunología
4.
J Virol Methods ; 287: 114004, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33098957

RESUMEN

Zika virus (ZIKV) infection remains a public health concern necessitating demand for long-term virus production for diagnostic assays and R&D activities. Inactivated virus constitutes an important component of the Trioplex rRT-PCR assay and serological IgM assay (MAC-ELISA). The aim of our study is to establish standard methods of ZIKV inactivation while maintaining antigenicity and RNA integrity. We tested viral supernatants by four different inactivation methods: 1. Heat inactivation at 56 °C and 60 °C; 2. Gamma-Irradiation; 3. Chemical inactivation by Beta-propiolactone (BPL) and 4. Fast-acting commercial disinfecting agents. Effectivity was measured by cytopathic effect (CPE) and plaque assay. RNA stability and antigenicity were measured by RT-PCR and MAC-ELISA, respectively. Results: Heat inactivation: Low titer samples, incubated at 56 °C for 2 h, showed neither CPE or plaques compared to high titer supernatants that required 2.5 h. Inactivation occurred at 60 °C for 60 min with all virus titers. Gamma irradiation: Samples irradiated at ≥3 Mrad for low virus concentrations and ≥5Mrad for high virus titer completely inactivated virus. Chemical Inactivation: Neither CPE nor plaques were observed with ≥0.045 % BPL inactivation of ZIKV. Disinfectant: Treatment of viral supernatants with Micro-Chem Plus™, inactivated virus in 2 min, whereas, Ethanol (70 %) and STERIS Coverage® Spray TB inactivated the virus in 5 min.


Asunto(s)
Infección por el Virus Zika , Virus Zika , Desinfección , Humanos , Indicadores y Reactivos , Inactivación de Virus , Infección por el Virus Zika/diagnóstico
5.
Mycoses ; 62(6): 513-518, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30801778

RESUMEN

Candida auris is an emerging multidrug-resistant yeast associated with invasive infection in healthcare settings. Recently, C auris cases in the United States have been detected in 11 states with the majority of cases in New York, New Jersey and Illinois. Rapid and accurate identification of C auris is critical for patient care and the implementation of public health measures to control the spread of infection. Our aim was to develop and validate a rapid DNA extraction method using the Roche MagNA Pure 96 instrument and a TaqMan real-time PCR assay for reliable, high-throughput identification of C auris. We evaluated 247 patient dermal swab samples previously analysed by culture/MALDI-TOF. The diagnostic sensitivity and specificity were 93.6% and 97.2%, respectively. The assay was highly reproducible with a detection limit of 1 C auris CFU/10 µL. A receiver operating characteristic curve analysis of the real-time PCR data showed an area of 0.982 under the curve, with a CT cut-off value of ≤37.0. The turnaround time from DNA extraction to real-time PCR results was approximately 200 samples/day. In conclusion, we successfully validated a rapid and high-throughput method for accurate and reproducible identification of C auris with a significantly reduced turnaround time compared to culture/MALDI-TOF based methods.


Asunto(s)
Candida/aislamiento & purificación , Candidiasis Invasiva/diagnóstico , Candidiasis Invasiva/microbiología , ADN de Hongos/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Manejo de Especímenes/métodos , Candida/genética , Enfermedades Transmisibles Emergentes/diagnóstico , Enfermedades Transmisibles Emergentes/microbiología , ADN de Hongos/genética , Farmacorresistencia Fúngica Múltiple , Humanos , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...