Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
2.
Int J Cardiol ; 399: 131700, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38168556

RESUMEN

BACKGROUND: Changes in QRS duration (∆QRS) are often used in the clinical setting to evaluate the effect of cardiac resynchronization therapy (CRT), although an association between ∆QRS and outcomes is not firmly established. We aimed to assess the association between mortality and ∆QRS after CRT in patients from the DANISH (Danish Study to Assess the Efficacy of ICDs in Patients with Non-Ischemic Systolic Heart Failure on Mortality) study. METHODS: We included all patients from DANISH who received a CRT device and had available QRS duration data before and after implantation. Cox proportional hazards models were used to assess associations between ∆QRS (post-CRT QRS minus pre-CRT QRS) and mortality. RESULTS: Complete data were available in 572 patients. Median baseline QRS duration was 160 ms (IQR [146;180]). Post-CRT QRS was recorded a median of 48 days (IQR [33;86]) after implantation, and the median ∆QRS was -14 ms (IQR [-38;-3]). During a median follow-up of 4.1 years (IQR [2.5;5.8]), 106 patients died. In crude Cox regression, all-cause mortality was reduced by 6% per 10 ms shortening of QRS (HR 0.94; CI: 0.88-1.00, p = 0.04). The effect did not remain significant after multivariable adjustment (HR 1.01, CI: 0.93-1.10, p = 0.77). Further, no association was found between ∆QRS and improvement of New York Heart Association functional class at 6 months (OR 1.03, CI: 0.96-1.10, p = 0.42). CONCLUSION: In a large cohort of patients with non-ischemic cardiomyopathy, reduction of QRS duration after CRT was not associated with changes in mortality during long-term follow-up.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Resultado del Tratamiento , Dispositivos de Terapia de Resincronización Cardíaca , Dinamarca/epidemiología , Electrocardiografía
3.
Artículo en Inglés | MEDLINE | ID: mdl-37682525

RESUMEN

BACKGROUND AND AIM: There are a paucity of studies investigating workforce affiliation in connection with first-time ICD-implantation. This study explored workforce affiliation and risk markers associated with not returning to work in patients with ICDs. METHODS: Using the nationwide Danish registers, patients with a first-time ICD-implantation between 2007-2017 and of working age (30-65 years) were identified. Descriptive statistic and logistic regression models were used to describe workforce affiliation and to estimate risk markers associated with not returning to work, respectively. All analyses were stratified by indication for implantation (primary and secondary prevention). RESULTS: Of the 4,659 ICD-patients of working age, 3,300 patients (71%) were members of the workforce (employed, on sick leave or unemployed) (primary: 1428 (43%); secondary:1872 (57%)). At baseline, 842 primary and 1477 secondary prevention ICD-patients were employed. Of those employed at baseline, 81% primary and 75% secondary prevention ICD-patients returned to work within one-year, whereof more than 80% remained employed the following year. Among patients receiving sick leave benefits at baseline, 25% were employed after one-year. Risk markers of not returning to work were 'younger age' in primary prevention ICD-patients, while 'female sex', 'LVEF ≤40', 'lower income' and '≥3 comorbidities' were risk markers in secondary prevention ICD-patients. Lower educational level was a risk marker in both patient groups. CONCLUSIONS: High return-to-work proportions following ICD-implantation, with a subsequent high level of employment maintenance were found. Several significant risk markers of not returning to work were identified including 'lower educational level', that posed a risk in both patient groups.Trial registration number: Capital Region of Denmark, P-2019-051.

4.
Int J Cardiovasc Imaging ; 39(11): 2097-2106, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37470856

RESUMEN

Plasma potassium (p-K) in the high-normal range has been suggested to reduce risk of cardiovascular arrythmias and mortality through electrophysiological and mechanical effects on the myocardium. In this study, it was to investigated if increasing p-K to high-normal levels improves systolic- and diastolic myocardial function in patients with low-normal to moderately reduced left ventricular ejection fraction (LVEF). The study included 50 patients (mean age 58 years (SD 14), 81% men), with a mean p-K 3.95 mmol/l (SD 0.19), mean LVEF 48% (SD 7), and mean Global Longitudinal Strain (GLS) -14.6% (SD 3.1) patients with LVEF 35-55% from "Targeted potassium levels to decrease arrhythmia burden in high-risk patients with cardiovascular diseases trial" (POTCAST). Patients were given standard therapy and randomized (1:1) to an intervention that included guidance on potassium-rich diets, potassium supplements, and mineralocorticoid receptor antagonists targeting high-normal p-K levels (4.5-5.0 mmol/l). Echocardiography was done at baseline and after a mean follow-up of 44 days (SD 18) and the echocardiograms were analyzed for changes in GLS, mechanical dispersion, E/A, e', and E/e'. At follow-up, mean difference in changes in p-K was 0.52 mmol/l (95%CI 0.35;0.69), P<0.001 in the intervention group compared to controls. GLS was improved with a mean difference in changes of -1.0% (-2;-0.02), P<0.05 and e' and E/e' were improved with a mean difference in changes of 0.9 cm/s (0.02;1.7), P = 0.04 and ? 1.5 (-2.9;-0.14), P = 0.03, respectively. Thus, induced increase in p-K to the high-normal range improved indices of systolic and diastolic function in patients with low-normal to moderately reduced LVEF.


Asunto(s)
Disfunción Ventricular Izquierda , Función Ventricular Izquierda , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arritmias Cardíacas , Miocardio , Potasio/farmacología , Valor Predictivo de las Pruebas , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/diagnóstico por imagen
5.
Eur Heart J Cardiovasc Imaging ; 25(1): 29-36, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-37490039

RESUMEN

AIMS: Non-invasive left ventricular (LV) pressure-strain loops provide a novel method for quantifying myocardial work by incorporating LV pressure in measurements of myocardial deformation. Early studies suggest that myocardial work parameters such as global constructive work (GCW) could be useful and reliable in arrhythmia prediction, particularly in patients undergoing cardiac resynchronization therapy (CRT). The aim of this study was to evaluate whether the magnitude of GCW was associated with the occurrence of ventricular arrhythmias in patients after CRT. METHODS AND RESULTS: Patients on guideline-recommended treatment with a CRT defibrillator (CRT-D) were evaluated by 2D speckle-tracking echocardiography including measurements of GCW at least 6 months after implantation. The primary outcome was a composite of appropriate defibrillator therapy and sustained ventricular arrhythmia under the monitor zone. A total of 162 patients [mean age 66 years (±10), 122 males (75%)] were included. Sixteen (10%) patients experienced the primary outcome during a median follow-up of 18 months (interquartile range: 12-25) after the performance of index echocardiography. Patients with a below-median GCW (<1473 mmHg%) had a hazard ratio (HR) for the outcome of 8.14 [95% confidence interval (CI): 1.83-36.08], P = 0.006 compared with patients above the median in a univariate model and remained an independent predictor after multivariate adjustment for the estimated glomerular filtration rate and QRS duration [HR 4.75 (95% CI: 1.01-22.28), P < 0.05]. CONCLUSION: In patients treated with CRT-D, a GCW below median level was associated with a five-fold increase in the risk of ventricular arrhythmias.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Masculino , Humanos , Anciano , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/terapia , Ecocardiografía , Resultado del Tratamiento , Función Ventricular Izquierda
6.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37335977

RESUMEN

AIMS: To date, potential differences in outcomes for immigrants and non-immigrants with a cardiac resynchronization therapy (CRT), in a European setting, remain underutilized and unknown. Hence, we examined the efficacy of CRT measured by heart failure (HF)-related hospitalizations and all-cause mortality among immigrants and non-immigrants. METHODS AND RESULTS: All immigrants and non-immigrants who underwent first-time CRT implantation in Denmark (2000-2017) were identified from nationwide registries and followed for up to 5 years. Differences in HF related hospitalizations and all-cause mortality were evaluated by Cox regression analyses. From 2000 to 2017, 369 of 10 741 (3.4%) immigrants compared with 7855 of 223 509 (3.5%) non-immigrants with a HF diagnosis underwent CRT implantation. The origins of the immigrants were Europe (61.2%), Middle East (20.1%), Asia-Pacific (11.9%), Africa (3.5%), and America (3.3%). We found similar high uptake of HF guideline-directed pharmacotherapy before and after CRT and a consistent reduction in HF-related hospitalizations the year before vs. the year after CRT (61% vs. 39% for immigrants and 57% vs. 35% for non-immigrants). No overall difference in 5-year mortality among immigrants and non-immigrants was seen after CRT [24.1% and 25.8%, respectively, P-value = 0.50, hazard ratio (HR) = 1.2, 95% confidence interval (CI): 0.8-1.7]. However, immigrants of Middle Eastern origin had a higher mortality rate (HR = 2.2, 95% CI: 1.2-4.1) compared with non-immigrants. Cardiovascular causes were responsible for the majority of deaths irrespective of immigration status (56.7% and 63.9%, respectively). CONCLUSION: No overall differences in efficacy of CRT in improving outcomes between immigrants and non-immigrants were identified. Although numbers were low, a higher mortality rate among immigrants of Middle Eastern origin was identified compared with non-immigrants.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Resultado del Tratamiento , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Modelos de Riesgos Proporcionales , Desfibriladores Implantables/efectos adversos
7.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37129985

RESUMEN

AIMS: Reduced psychological health is associated with adverse patient outcomes and higher mortality. We aimed to examine if a Brugada syndrome (BrS) diagnosis and symptomatic disease presentation were associated with an increased risk of new-onset depression or anxiety and all-cause mortality. METHODS AND RESULTS: All Danish patients diagnosed with BrS (2006-2018) with no history of psychiatric disease and available for ≥6 months follow-up were identified using nationwide registries and followed for up to 5 years after diagnosis. The development of clinical depression or anxiety was evaluated using the prescription of medication and diagnosis codes. Factors associated with developing new-onset depression or anxiety were determined using a multivariate Cox proportional hazards regression model. Disease manifestation was categorized as symptomatic (aborted cardiac arrest, ventricular tachycardia, or syncope) or asymptomatic/unspecified at diagnosis. A total of 223 patients with BrS and no history of psychiatric disease were identified (72.6% male, median age at diagnosis 46 years, 45.3% symptomatic). Of these, 15.7% (35/223) developed new-onset depression or anxiety after BrS diagnosis (median follow-up 5.0 years). A greater proportion of symptomatic patients developed new-onset depression or anxiety compared with asymptomatic patients [21/101 (20.8%) and 14/122 (11.5%), respectively, P = 0.08]. Symptomatic disease presentation (HR 3.43, 1.46-8.05) and older age (lower vs. upper tertile: HR 4.41, 1.42-13.63) were significantly associated with new-onset depression or anxiety. All-cause mortality in this group of patients treated according to guidelines was low (n = 4, 1.8%); however, 3/4 developed depression or anxiety before death. CONCLUSION: Approximately, one-sixth of patients with BrS developed new-onset depression or anxiety following a diagnosis of BrS. Symptomatic BrS disease manifestation was significantly associated with new-onset depression or anxiety.


Asunto(s)
Síndrome de Brugada , Humanos , Masculino , Persona de Mediana Edad , Femenino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiología , Síndrome de Brugada/complicaciones , Depresión/diagnóstico , Depresión/epidemiología , Muerte Súbita Cardíaca/etiología , Electrocardiografía/métodos , Medición de Riesgo/métodos , Ansiedad/diagnóstico , Ansiedad/epidemiología , Dinamarca/epidemiología
8.
Pacing Clin Electrophysiol ; 46(7): 721-728, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37120825

RESUMEN

BACKGROUND: Reduced systolic myocardial function in the inferior region of the left ventricle has been suggested to be associated with malignant arrhythmias. We tested this hypothesis in patients with non-ischemic heart failure. METHODS: Patients with non-ischemic heart failure (left ventricular ejection fraction [LVEF] < 35%) were evaluated by 2D-speckle-tracking echocardiography. The regional longitudinal strain was calculated for each of the six left ventricular walls. The reduced regional function was defined as strain below the median. The outcome was a composite of sudden cardiac death, admission with sustained ventricular arrhythmia, resuscitated cardiac arrest, and appropriate therapy from a primary prophylactic implantable cardioverter defibrillator. Time-to-first-event analysis was performed using a Cox model. RESULTS: From two centers, 401 patients were included (median age: 63 years, 72% male) with a median LVEF of 25% (interquartile range [IQR] 20;30), and a median inferior wall strain of -9.0% (-12.5; -5.4). During a median follow-up of 4.0 years, 52 outcomes occurred. After multivariate adjustment for clinical and electrocardiographic parameters, inferior wall strain was independently associated with the outcome (HR 2.50 [1.35; 4.62], p = .003). No independent association was found between the composite outcome and reduced strain in any of the other left ventricular walls, Global Longitudinal Strain (HR 1.66 [0.93; 2.98], p = .09), or LVEF (HR 1.33 [0.75; 2.33], p = .33). CONCLUSIONS: Below median strain in the left ventricular inferior region was independently associated with a 2.5-fold increase in the risk of malignant arrhythmias and sudden cardiac death in patients with non-ischemic heart failure.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Humanos , Masculino , Persona de Mediana Edad , Femenino , Función Ventricular Izquierda , Volumen Sistólico , Factores de Riesgo , Valor Predictivo de las Pruebas , Arritmias Cardíacas , Muerte Súbita Cardíaca/prevención & control , Insuficiencia Cardíaca/complicaciones
9.
J Am Heart Assoc ; 12(7): e028424, 2023 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-36942759

RESUMEN

Background Patients with Brugada syndrome (BrS) are recommended to avoid drugs that may increase their risk of arrhythmic events. We examined treatment with such drugs in patients with BrS after their diagnosis. Methods and Results All Danish patients diagnosed with BrS (2006-2018) with >12 months of follow-up were identified from nationwide registries. Nonrecommended BrS drugs were grouped into drugs to "avoid" or "preferably avoid" according to http://www.brugadadrugs.org. Cox proportional hazards analyses were performed to identify factors associated with any nonrecommended BrS drug use, and logistic regression analyses were performed to examine associated risk of appropriate implantable cardioverter defibrillator therapy, mortality, and a combined end point indicating an arrhythmic event of delayed implantable cardioverter defibrillator implantation, appropriate implantable cardioverter defibrillator therapy, and mortality. During a median follow-up of 6.8 years, 93/270 (34.4%) patients with BrS (70.4% male, median age at diagnosis 46.1 years [interquartile range, 32.6-57.4]) were treated with ≥1 nonrecommended BrS drugs. No difference in any nonrecommended BrS drug use was identified comparing time before BrS diagnosis (12.6%) with each of the 5 years following BrS diagnosis (P>0.05). Factors associated with any nonrecommended BrS drug use after diagnosis were female sex (hazard ratio [HR]) 1.83 [95% CI, 1.15-2.90]), psychiatric disease (HR, 3.63 [1.89-6.99]), and prior use of any nonrecommended BrS drug (HR, 4.76 [2.45-9.25]). No significant association between any nonrecommended BrS drug use and implantable cardioverter defibrillator therapy (n=20/97, odds ratio [OR], 0.7 [0.2-2.4]), mortality (n=10/270, OR, 3.4 [0.7-19.6]), or the combined end point (n=38/270, OR, 1.7 [0.8-3.7]) was identified. Conclusions One in 3 patients with BrS were treated with a nonrecommended BrS drug after BrS diagnosis, and a BrS diagnosis did not change prescription patterns. More awareness of nonrecommended drug use among patients with BrS is needed.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Humanos , Masculino , Femenino , Persona de Mediana Edad , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/complicaciones , Estudios de Cohortes , Electrocardiografía/métodos , Dinamarca/epidemiología , Muerte Súbita Cardíaca
10.
Gen Hosp Psychiatry ; 80: 54-61, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36638700

RESUMEN

OBJECTIVE: Identify implantable cardioverter defibrillator (ICD) patients at risk of distress (i.e., depression, anxiety, and ICD concerns) and associated risk factors. METHOD: First-time ICD patients (n = 1503) from the Danish national DEFIB-WOMEN study completed questionnaires at baseline, 3, 6, 12 and 24 months. RESULTS: Of patients with low scores on distress, only 4%-7.2% experienced an increase in distress during 24 months of follow-up (FU), while 30.5%-52.5% with increased levels were likely to maintain increased levels at FU. Higher education, higher age, female sex, and good physical functioning at baseline were associated with less depression, anxiety and ICD concerns at FU. Previous psychological problems, smoking, Type D personality, NYHA class III-IV - all assessed at baseline - and shocks during FU were associated with depression, anxiety and ICD concerns. CONCLUSIONS: Generally, patients' psychological health improved, but patients with increased baseline scores were more likely to have increased scores at FU. We need to be vigilant if patients report elevated distress, particularly if they have depression at baseline, as depression seems more persistent. Given the impact of depression on health-related quality of life and prognosis, they should be screened and monitored closely.


Asunto(s)
Desfibriladores Implantables , Humanos , Femenino , Desfibriladores Implantables/psicología , Calidad de Vida/psicología , Depresión/epidemiología , Depresión/terapia , Depresión/etiología , Estudios de Seguimiento , Ansiedad/epidemiología , Ansiedad/psicología , Dinamarca/epidemiología
11.
J Card Fail ; 29(6): 883-892, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36708755

RESUMEN

BACKGROUND: Patients with nonischemic systolic heart failure have an increased risk of malignant ventricular arrhythmias and sudden cardiovascular death. Because the risk is less pronounced than for patients with ischemic cause of heart failure more discriminating tools are needed to identify patients most likely to benefit from implantable cardioverter-defibrillator (ICD) implantation. Right ventricular (RV) dysfunction is associated with a worse prognosis, but whether RV free wall strain (RV-FWS) measured with echocardiography can identify the patients most likely to benefit from ICD implantation is not known. METHODS AND RESULTS: In this extended follow-up analysis of the Danish Study to Assess the Efficacy of ICDs in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH) trial, RV-FWS was measured with echocardiography in 445 patients before randomization. RV dysfunction was defined as an RV-FWS of greater than -20%. The primary end point was all-cause mortality. The median RV-FWS was -18% (quartiles -23% to -14%), and RV dysfunction was measured in 255 patients (57%). During a median follow-up of 5.7 years, 170 patients (38%) died. There was a statistically significant interaction between RV dysfunction and the effect of ICD implantation (P = .003), also after adjusting for known cardiovascular risk factors (P = .01). ICD implantation significantly decreased all-cause mortality in patients with RV dysfunction (hazard ratio 0.54, 95% confidence interval 0.36-0.80, P = .002), but not in patients with normal RV function (hazard ratio 1.34, 95% confidence interval 0.84-2.12, P = .22). CONCLUSIONS: In patients with nonischemic systolic heart failure, RV dysfunction on echocardiography was associated with a greater effect of ICD implantation and could be used to select patients with benefit from ICD treatment.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca Sistólica , Humanos , Insuficiencia Cardíaca Sistólica/diagnóstico por imagen , Insuficiencia Cardíaca Sistólica/terapia , Muerte Súbita Cardíaca/etiología , Corazón , Desfibriladores Implantables/efectos adversos , Pronóstico
12.
J Psychosom Res ; 164: 111072, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36459826

RESUMEN

OBJECTIVE: The implantable cardioverter defibrillator (ICD) is used to treat malignant ventricular arrhythmias. Since 33% of patients experience ICD-related concerns, we examined sex differences in ICD concerns and correlates of ICD concerns during 24 months of follow-up after implantation of an ICD. METHODS: Patients from the DEFIB-WOMEN study (n = 1515; 81.6% male patients) completed questionnaires on ICD concerns, anxiety, depression, and Type D personality at five measure points (baseline, 3-, 6-, 12- and 24-months post-implantation). RESULTS: Male patients scored on average 7.0 (6.8) points on ICD concerns at the time of implantation and female patients scored on average 10.5 (8.2) points. We found statistically significant sex differences in ICD concerns at all measurement points, with female patients scoring 2.77 points (8.7% of the maximum score of 32) higher than male patients. ICD concerns decreased in both sexes the first 6 months and then levelled out. For both sexes, ICD concerns at baseline were significantly correlated with ICD concerns at 24-months follow-up. Anxiety at baseline was correlated with ICD concerns in female patients, while depression at baseline and at least one experienced shock correlated with ICD concerns in male patients. CONCLUSION: Female patients reported more ICD concerns at all measurement points compared to male patients, but for both sexes ICD concerns decreased in the first 6 months. ICD shock, anxiety, depression, and ICD concerns at baseline were correlates of ICD concerns at 24-months follow-up.


Asunto(s)
Desfibriladores Implantables , Femenino , Humanos , Masculino , Ansiedad/epidemiología , Desfibriladores Implantables/psicología , Dinamarca/epidemiología , Distribución por Sexo , Depresión/epidemiología , Personalidad Tipo D , Estudios de Seguimiento , Factores de Riesgo , Encuestas y Cuestionarios
13.
Heart Lung Circ ; 32(3): 364-372, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36513581

RESUMEN

AIM: The COVID-19 pandemic resulted in a significant decrease in the number of hospital admissions for severe emergent cardiovascular diseases during lockdowns worldwide. This study aimed to determine the impact of both the first and the second Danish nationwide lockdown on the implantation rate of cardiac implantable electronic devices (CIEDs). METHODS: We retrospectively analysed the number of CIED implantations performed in Denmark and stratified them into 3-week intervals. RESULTS: The total number of de novo CIED implantations decreased during the first lockdown by 15.5% and during the second by 5.1%. Comparing each 3-week interval using rate ratios, a significant decrease in the daily rates of the total number of de novo and replacement CIEDs (0.82, 95% CI [0.70, 0.96]), de novo CIEDs only (0.82, 95% CI [0.69, 0.98]), and non-acute pacemaker implantations (0.80, 95% CI [0.63, 0.99]) was observed during the first interval of the first lockdown. During the second lockdown (third interval), a significant decrease was seen in the daily rates of de novo CIEDs (0.73, 95% CI [0.55, 0.97]), and of pacemakers in total during both the second (0.78, 95% CI [0.62, 0.97]) and the third (0.60, 95% CI [0.42, 0.85]) intervals. Additionally, the daily rates of acute pacemaker implantation decreased during the second interval (0.47, 95% CI [0.27, 0.79]) and of non-acute implantation during the third interval (0.57, 95% CI [0.38, 0.84]). A significant increase was observed in the number of replacement procedures during the first interval of the second lockdown (1.70, 95% CI [1.04, 2.85]). CONCLUSIONS: Our study found only modest changes in CIED implantations in Denmark during two national lockdowns.


Asunto(s)
COVID-19 , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Estudios Retrospectivos , Pandemias , Factores de Riesgo , COVID-19/epidemiología , Control de Enfermedades Transmisibles
14.
Eur Heart J ; 44(9): 752-761, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36433808

RESUMEN

AIMS: The present study aimed to determine the association between Type 2 diabetes mellitus (T2DM) and third-degree (complete) atrioventricular block. METHODS AND RESULTS: This nationwide nested case-control study included patients older than 18 years, diagnosed with third-degree atrioventricular block between 1 July 1995 and 31 December 2018. Data on medication, comorbidity, and outcomes were collected from Danish registries. Five controls, from the risk set of each case of third-degree atrioventricular block, were matched on age and sex to fit a Cox regression model with time-dependent exposure and time-dependent covariates. Subgroup analysis was conducted with Cox regression models for each subgroup. We located 25 995 cases with third-degree atrioventricular block that were matched with 130 004 controls. The mean age was 76 years and 62% were male. Cases had more T2DM (21% vs. 11%), hypertension (69% vs. 50%), atrial fibrillation (25% vs. 10%), heart failure (20% vs. 6.3%), and myocardial infarction (19% vs. 9.2%), compared with the control group. In Cox regression analysis, adjusting for comorbidities and atrioventricular nodal blocking agents, T2DM was significantly associated with third-degree atrioventricular block (hazard ratio: 1.63, 95% confidence interval: 1.57-1.69). The association remained in several subgroup analyses of diseases also suspected to be associated with third-degree atrioventricular block. There was a significant interaction with comorbidities of interest including hypertension, atrial fibrillation, heart failure, and myocardial infarction. CONCLUSION: In this nationwide study, T2DM was associated with a higher rate of third-degree atrioventricular block compared with matched controls. The association remained independent of atrioventricular nodal blocking agents and other comorbidities known to be associated with third-degree atrioventricular block.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Diabetes Mellitus Tipo 2 , Insuficiencia Cardíaca , Hipertensión , Infarto del Miocardio , Humanos , Masculino , Anciano , Femenino , Estudios de Casos y Controles , Sistema de Registros , Dinamarca
15.
Int J Cardiovasc Imaging ; 38(11): 2437-2445, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36434345

RESUMEN

Patients with non-ischemic systolic heart failure (HF) have increased risk of sudden cardiovascular death (SCD). The initiation and substrate for ventricular arrhythmias remains poorly understood. Our purpose was to describe the relationship between cardiac magnetic resonance (CMR) late gadolinium enhancement (LGE) and Holter recorded ventricular arrhythmic activity. Patients from the DANISH trial underwent a Holter-recording and a CMR-scan. The presence of non-sustained ventricular tachycardia (NSVT) and premature ventricular contractions (PVC) were examined in relation to presence and amount of LGE. Outcome measures were all-cause mortality and SCD. Overall, 180 patients were included. LGE was present in 86 (47%). NSVT occurred in 72 (40%), not different according to LGE status (p = 0.65). The amount of LGE was not correlated to the occurrence of NSVT (p = 0.40). The occurrence of couplet PVCs (p = 0.997), frequent PVCs (p = 0.12), PVCs in bigemini (p = 0.29), in trigemini (p = 0.26), or in quadrimini (p = 0.35) did not differ according to LGE status. LGE was significantly associated with risk of all-cause mortality (HR 2.14; 95% CI 1.05-4.37, p = 0.04). NSVT did not increase risk of all-cause mortality in either patients with LGE (HR 1.00; 95% CI 0.46-2.16, p = 0.996) or without LGE (HR 1.37; 95% CI 0.46-4.08, p = 0.57). There was no interaction between LGE and NSVT for the risk of all-cause mortality (p = 0.62). In patients with non-ischemic systolic HF there was no relationship between the presence of LGE and NSVT or any other Holter recorded ventricular tachyarrhythmia. LGE was associated with increased risk of mortality, independent of the presence of NSVT.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca Sistólica , Complejos Prematuros Ventriculares , Humanos , Cardiomiopatías/complicaciones , Medios de Contraste , Muerte Súbita Cardíaca/etiología , Dinamarca , Fibrosis , Gadolinio , Insuficiencia Cardíaca Sistólica/complicaciones , Insuficiencia Cardíaca Sistólica/diagnóstico , Valor Predictivo de las Pruebas , Factores de Riesgo , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/complicaciones
16.
Eur Heart J ; 43(47): 4946-4956, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36263789

RESUMEN

AIMS: Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patient-related risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. METHODS AND RESULTS: Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29-2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65-3.49), dermatitis (HR: 2.80, 95% CI: 1.92-4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59-2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. CONCLUSION: Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Incidencia , Factores de Riesgo , Electrónica , Dinamarca/epidemiología , Estudios Retrospectivos
17.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-36030464

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Humanos , Resultado del Tratamiento , Desfibriladores Implantables/efectos adversos
18.
Heart Rhythm ; 19(3): 363-371, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34767985

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead monitoring diagnostic alerts facilitate the diagnosis of structural lead failure. OBJECTIVE: The purpose of this study was to prospectively study the performance of Medtronic ICD lead monitoring alerts. METHODS: A prespecified ancillary substudy, World-Wide Randomized Antibiotic Envelope Infection Prevention Trial, was conducted in patients with an ICD with all available alerts enabled. The investigators reported possible lead system events (LSEs), with or without an alert. An independent committee reviewed all data and classified events as lead failure, other LSE, or nonlead system events (NLEs). RESULTS: In 4942 patients who were followed for 19.4 ± 8.7 months, there were 124 alerts (65 LSEs, 59 NLEs) and 19 LSEs without an alert. Lead monitoring alerts had 100% sensitivity for the 48 adjudicated lead failures (95% confidence interval 92.6%-100%) and for 10 events adjudicated as either lead failure or connection issue. The positive predictive value of alerts for lead failure was 38.7% (48 of 124). For 34 pace-sense lead failures, an alert that incorporated oversensing was more sensitive than the pacing impedance threshold alert (33 patients [97.1%] vs 9 patients [26.5%]; P < .0001). However, the sensitivity was only 13.6% for lead dislodgments or perforations. Inappropriate shocks occurred in 2 patients with pace-sense lead failure (5.9%). No patient had unnecessary lead replacement for any of the NLEs. CONCLUSION: In this first real-world prospective study, lead monitoring alerts had 100% sensitivity for identifying lead failures. Although their positive predictive value was modest, no false-positive alerts resulted in an unnecessary lead replacement. For the diagnosis of pace-sense lead failure, an alert for oversensing was more sensitive than a pacing impedance threshold alert. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02277990.


Asunto(s)
Desfibriladores Implantables , Desfibriladores Implantables/efectos adversos , Impedancia Eléctrica , Falla de Equipo , Humanos , Valor Predictivo de las Pruebas , Estudios Prospectivos
19.
Circulation ; 145(5): 321-329, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34779221

RESUMEN

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables/normas , Anciano , Arritmias Cardíacas/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
20.
Circulation ; 145(10): 754-764, 2022 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-34889650

RESUMEN

BACKGROUND: Identification of patients with nonischemic cardiomyopathy who may benefit from prophylactic implantation of a cardioverter-defibrillator. We hypothesized that periodic repolarization dynamics (PRD), a marker of repolarization instability associated with sympathetic activity, could be used to identify patients who will benefit from prophylactic implantable cardioverter defibrillator (ICD) implantation. METHODS: We performed a post hoc analysis of DANISH (Danish ICD Study in Patients With Dilated Cardiomyopathy), in which patients with nonischemic cardiomyopathy, left ventricular ejection fraction (LVEF) ≤35%, and elevated NT-proBNP (N-terminal probrain natriuretic peptides) were randomized to ICD implantation or control group. Patients were included in the PRD substudy if they had a 24-hour Holter monitor recording at baseline with technically acceptable ECG signals during the night hours (00:00-06:00). PRD was assessed using wavelet analysis according to previously validated methods. The primary end point was all-cause mortality. Cox regression models were adjusted for age, sex, NT-proBNP, estimated glomerular filtration rate, LVEF, atrial fibrillation, ventricular pacing, diabetes, cardiac resynchronization therapy, and mean heart rate. We proposed PRD ≥10 deg2 as an exploratory cut-off value for ICD implantation. RESULTS: A total of 748 of the 1116 patients in DANISH qualified for the PRD substudy. During a mean follow-up period of 5.1±2.0 years, 82 of 385 patients died in the ICD group and 85 of 363 patients died in the control group (P=0.40). In Cox regression analysis, PRD was independently associated with mortality (hazard ratio [HR], 1.28 [95% CI, 1.09-1.50] per SD increase; P=0.003). PRD was significantly associated with mortality in the control group (HR, 1.51 [95% CI, 1.25-1.81]; P<0.001) but not in the ICD group (HR, 1.04 [95% CI, 0.83-1.54]; P=0.71). There was a significant interaction between PRD and the effect of ICD implantation on mortality (P=0.008), with patients with higher PRD having greater benefit in terms of mortality reduction. ICD implantation was associated with an absolute mortality reduction of 17.5% in the 280 patients with PRD ≥10 deg2 (HR, 0.54 [95% CI, 0.34-0.84]; P=0.006; number needed to treat=6), but not in the 468 patients with PRD <10 deg2 (HR, 1.17 [95% CI, 0.77-1.78]; P=0.46; P for interaction=0.01). CONCLUSIONS: Increased PRD identified patients with nonischemic cardiomyopathy in whom prophylactic ICD implantation led to significant mortality reduction.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Desfibriladores Implantables , Cardiomiopatías/diagnóstico , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Dinamarca/epidemiología , Humanos , Volumen Sistólico , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA