Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Lancet Infect Dis ; 22(9): 1356-1364, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35716700

RESUMEN

BACKGROUND: Acute febrile illness is a common presentation for patients at hospitals globally. Assays that can diagnose a variety of common pathogens in blood could help to establish a diagnosis for targeted disease management. We aimed to evaluate the performance of the BioFire Global Fever Panel (GF Panel), a multiplex nucleic acid amplification test performed on whole blood specimens run on the BioFire FilmArray System, in the diagnosis of several pathogens that cause acute febrile illness. METHODS: We did a prospective, multicentre, cross-sectional diagnostic accuracy study to evaluate the GF Panel. Consenting adults and children older than 6 months presenting with fever in the previous 2 days were enrolled consecutively in sub-Saharan Africa (Ghana, Kenya, Tanzania, Uganda), southeast Asia (Cambodia, Thailand), central and South America (Honduras, Peru), and the USA (Washington, DC; St Louis, MO). We assessed the performance of six analytes (chikungunya virus, dengue virus [serotypes 1-4], Leptospira spp, Plasmodium spp, Plasmodium falciparum, and Plasmodium vivax or Plasmodium ovale) on the GF Panel. The performance of the GF Panel was assessed using comparator PCR assays with different primers followed by bidirectional sequencing on nucleic acid extracts from the same specimen. We calculated the positive percent agreement and negative percent agreement of the GF Panel with respect to the comparator assays. This study is registered with ClinicalTrials.gov, NCT02968355. FINDINGS: From March 26, 2018, to Sept 30, 2019, 1965 participants were enrolled at ten sites worldwide. Of the 1875 participants with analysable results, 980 (52·3%) were female and the median age was 22 years (range 0-100). At least one analyte was detected in 657 (35·0%) of 1875 specimens. The GF Panel had a positive percent agreement for the six analytes evaluated as follows: chikungunya virus 100% (95% CI 86·3-100), dengue virus 94·0% (90·6-96·5), Leptospira spp 93·8% (69·8-99·8), Plasmodium spp 98·3% (96·3-99·4), P falciparum 92·7% (88·8-95·6), and P vivax or P ovale 92·7% (86·7-96·6). The GF Panel had a negative percent agreement equal to or greater than 99·2% (98·6-99·6) for all analytes. INTERPRETATION: This 1 h sample-to-answer, molecular device can detect common causative agents of acute febrile illness with excellent positive percent agreement and negative percent agreement directly in whole blood. The targets of the assay are prevalent in tropical and subtropical regions globally, and the assay could help to provide both public health surveillance and individual diagnoses. FUNDING: BioFire Defense, Joint Project Manager for Medical Countermeasure Systems and US Army Medical Materiel Development Activity, and National Institute of Allergy and Infectious Diseases.


Asunto(s)
Fiebre Chikungunya , Virus Chikungunya , Dengue , Leptospirosis , Malaria , Plasmodium , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Estudios Transversales , Femenino , Fiebre , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
2.
Malar J ; 20(1): 133, 2021 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-33676502

RESUMEN

BACKGROUND: Rapid and sensitive diagnostics are critical tools for clinical case management and public health control efforts. Both capillary and venous blood are currently used for malaria detection and while diagnostic technologies may not be equally sensitive with both materials, the published data on this subject are scarce and not conclusive. METHODS: Paired clinical samples of venous and capillary blood from 141 febrile individuals in Bo, Sierra Leone, were obtained between January and May 2019 and tested for the presence of Plasmodium parasites using two multiplexed PCR assays: the FilmArray-based Global Fever Panel (GFP) and the TaqMan-based Malaria Multiplex Sample Ready (MMSR) assay. RESULTS: No significant differences in Plasmodium parasite detection between capillary and venous blood for both assays were observed. The GFP assay was more sensitive than MMSR for all markers that could be compared (Plasmodium spp. and Plasmodium falciparum) in both venous and capillary blood. CONCLUSIONS: No difference was found in malaria detection between venous and capillary blood using two different PCR-based detection assays. This data gives support for use of capillary blood, a material which can be obtained easier by less invasive methods, for PCR-based malaria diagnostics, independent of the platform.


Asunto(s)
Capilares/parasitología , Pruebas Diagnósticas de Rutina/estadística & datos numéricos , Malaria/diagnóstico , Reacción en Cadena de la Polimerasa Multiplex/estadística & datos numéricos , Plasmodium/aislamiento & purificación , Venas/parasitología , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Sierra Leona , Especificidad de la Especie , Adulto Joven
3.
Ophthalmology ; 127(4S): S84-S96, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32200831

RESUMEN

In the Multicenter Trial of Cryotherapy for Retinopathy of Prematurity (ROP), 4099 infants weighing less than 1251 g at birth underwent sequential ophthalmic examinations, beginning at age 4 to 6 weeks, to monitor the incidence and course of ROP. Overall, 65.8% of the infants developed ROP to some degree; 81.6% for infants of less than 1000 g birth weight. As expected, ROP incidence and severity were higher in lower birth weight and gestational age categories. Black infants appeared less susceptible to ROP, of all severity categories, than nonblack infants. The timing of retinal vascular events correlated more closely with postconceptional age than with postnatal age, implicating the level of maturity more than postnatal environmental influences in governing the timing of these vascular events. These results include the current incidence of various severity stages of ROP found in the United States and provide new. insight into the development of ROP.


Asunto(s)
Retinopatía de la Prematuridad/epidemiología , Retinopatía de la Prematuridad/fisiopatología , Peso al Nacer , Crioterapia , Femenino , Edad Gestacional , Humanos , Incidencia , Lactante , Recien Nacido con Peso al Nacer Extremadamente Bajo , Recién Nacido , Recién Nacido de muy Bajo Peso , Masculino , Retinopatía de la Prematuridad/terapia , Factores de Riesgo , Estados Unidos/epidemiología
4.
J Clin Virol ; 92: 20-24, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28505570

RESUMEN

BACKGROUND: The recent West Africa Ebola outbreak highlighted the need to provide access to rapid, safe and reliable Ebola Virus Disease diagnostics. OBJECTIVES: The objective of this field study was to assess the clinical performance of the FilmArray® BioThreat-E test for the detection of Ebola Zaïre virus in whole blood in symptomatic patients suspected of Ebola Virus Disease in Conakry (Guinea) from March to July 2015. STUDY DESIGN: The BioThreat-E test was compared to the two RT-PCRs, using serum, implemented at Donka Hospital in the emergency context: an in-house developed quantitative one-step RT-PCR adapted from the Weidmann technique, and the RealStar® Filovirus RT-PCR Kit 1.0 (Altona-Diagnostics). We also assessed the performance of this assay in noninvasive specimens (urine and saliva) to detect infected patients. RESULTS: Of 135 patients enrolled and eligible for performance assessment on whole blood, the sensitivity was 95.7% [95% CI: 85.5-99.5] and specificity 100% [95% CI: 95.9-100]. Of the 37 symptomatic infected patients able to provide saliva and/or urine samples, 34 of the 35 saliva samples and all 3 of the urine samples were positive with the BioThreat-E test. CONCLUSIONS: This study showed that the FilmArray BioThreat-E test performs comparably to conventional molecular tests under field conditions, providing results and interpretation in approximately 1h. Due to its operational characteristics, it can be easily deployed in the field during an epidemic and could also be a useful tool for post-outbreak surveillance.


Asunto(s)
Ebolavirus/genética , Fiebre Hemorrágica Ebola/diagnóstico , Técnicas de Diagnóstico Molecular , Adulto , Brotes de Enfermedades/prevención & control , Ebolavirus/aislamiento & purificación , Femenino , Guinea/epidemiología , Fiebre Hemorrágica Ebola/sangre , Fiebre Hemorrágica Ebola/epidemiología , Fiebre Hemorrágica Ebola/virología , Humanos , Masculino , ARN Viral/sangre , ARN Viral/orina , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Saliva/virología , Sensibilidad y Especificidad , Factores de Tiempo
5.
J Clin Microbiol ; 53(7): 2368-70, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25972415

RESUMEN

Laboratories associated with small hospitals often have limited expertise, personnel, and equipment to rapidly identify rare and emerging infectious diseases. We describe the successful use of the FilmArray system for rapid detection of Ebola virus directly from clinical samples in 6 out of 83 tested subjects in a small health care center in Sierra Leone.


Asunto(s)
Ebolavirus/aislamiento & purificación , Fiebre Hemorrágica Ebola/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena de la Polimerasa Multiplex/métodos , Virología/métodos , Sangre/virología , Ebolavirus/genética , Hospitales , Humanos , Faringe/virología , Sierra Leona
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...