1.
Clin Exp Optom ; : 1-10, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38484727

RESUMEN

CLINICAL RELEVANCE: Central visual field (VF) testing often requires focussed high-density test grids. The critical number of test locations for maximising structure-function concordance in the macula is not known. PURPOSE: The aim of this work is to determine the impact of the number of test locations in the central VF on binarized structure-function concordance in glaucoma. METHODS: Humphrey Field Analyser (HFA) 10-2 test grid and Cirrus optical coherence tomography Ganglion Cell Analysis (GCA) results from one eye of 155 glaucoma patients were extracted. Following anatomical correction for retinal ganglion cell displacement, the pointwise results of the central 36 locations of the 10-2 pattern deviation map and their corresponding locations within the GCA deviation map were recorded. The number of test locations was systematically reduced from 36 (4 locations per step) and added from 1 (1 location per step) and binarized structure-function concordance (p < 0.05 for both) at each step was evaluated. Eleven test point subtraction and addition models were developed. Concordance rates (proportion) were plotted as a function of number of test locations, and were fitted using segmental nonlinear regression to identify the critical point of inflection at which concordance was maximised and discordance minimised. RESULTS: Subtractive and additive approaches returned two-way estimates of the critical number, with, on average 8-14 test locations being the range at which structure-function concordance was optimised in the present cohort across all models. A randomised approach to subtracting or adding test locations returned critical numbers that were similar to systematic and empirical models, suggesting that specific test location was not as critical in optimising structure-function concordance compared to the number of test locations. CONCLUSION: There is a potential critical number (8-14) in macular visual field testing where binarized structure-function concordance is optimised, providing a framework for guiding the development of integrated macular test locations in VF testing for glaucoma.

2.
Clin Exp Optom ; 107(2): 107-109, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38467125
3.
Clin Exp Optom ; : 1-17, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38452795

RESUMEN

Clinical imaging provided by optical coherence tomography (OCT) and its variant, OCT-angiography (OCT-A), has revolutionised eyecare practice. The imaging techniques allow for the identification and quantification of ocular structures, supporting the diagnosis and prognosis of eye disease. In this review, an overview of the usefulness of OCT-A imaging in the diagnosis and management of a range of ocular conditions is provided when used in isolation or in combination with other imaging modalities and measures of visual function (visual field results). OCT-A imaging has the capacity to identify and quantify ocular vasculature non-invasively, thereby assisting the clinician in the diagnosis or to determine the efficacy of intervention in ocular conditions impacting retinal vasculature. Thus, additional clinically useful information can be obtained in eye diseases involving conditions such as those impacting retinal vessel occlusion, in diabetic retinopathy, inherited retinal dystrophy, age-related macular degeneration, choroidal neovascularisation and optic nerve disorders. Through a clinical case series, various ocular conditions are reviewed, and the impact of OCT-A imaging is discussed. Although OCT-A imaging has great promise and is already used in clinical management, there is a lack of set standards to characterise altered vascular features in disease and consequently for prognostication, primarily due to a lack of large-scale clinical trials and variability in OCT-A algorithms when generating quantitative parameters.

4.
Ophthalmic Physiol Opt ; 44(2): 426-441, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38226742

RESUMEN

PURPOSE: To examine the diagnostic accuracy of performing two (frontloaded) versus one (clinical standard) visual field (VF) test per visit for detecting the progression of early glaucoma in data derived from clinical populations. METHODS: A computer simulation model was used to follow the VFs of 10,000 glaucoma patients (derived from two cohorts: Heijl et al., Swedish cohort; and Chauhan et al., Canadian Glaucoma Study [CGS]) over a 10-year period to identify patients whose mean deviation (MD) progression was detected. Core data (baseline MD and progression rates) were extracted from two studies in clinical cohorts of glaucoma, which were modulated using SITA-Faster variability characteristics from previous work. Additional variables included follow-up intervals (six-monthly or yearly) and rates of perimetric data loss for any reason (0%, 15% and 30%). The main outcome measures were the proportions of progressors detected. RESULTS: When the Swedish cohort was reviewed six-monthly, the frontloaded strategy detected more progressors compared to the non-frontloaded method up to years 8, 9 and 10 of follow-up for 0%, 15% and 30% data loss conditions. The time required to detect 50% of cases was 1.0-1.5 years less for frontloading compared to non-frontloading. At 4 years, frontloading increased detection by 26.7%, 28.7% and 32.4% for 0%, 15% and 30% data loss conditions, respectively. Where both techniques detected progression, frontloading detected progressors earlier compared to the non-frontloaded strategy (78.5%-81.5% and by 1.0-1.3 years when reviewed six-monthly; 81%-82.9% and by 1.2-2.1 years when reviewed yearly). Accordingly, these patients had less severe MD scores (six-monthly review: 0.63-1.67 dB 'saved'; yearly review: 1.10-2.87 dB). The differences increased with higher rates of data loss. Similar tendencies were noted when applied to the CGS cohort. CONCLUSIONS: Frontloaded VFs applied to clinical distributions of MD and progression led to earlier detection of early glaucoma progression.


Asunto(s)
Glaucoma , Pruebas del Campo Visual , Humanos , Pruebas del Campo Visual/métodos , Campos Visuales , Presión Intraocular , Simulación por Computador , Estudios de Seguimiento , Estudios Retrospectivos , Trastornos de la Visión/diagnóstico , Progresión de la Enfermedad , Canadá , Glaucoma/diagnóstico
5.
Ophthalmic Physiol Opt ; 44(2): 457-471, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37990841

RESUMEN

PURPOSE: To describe variations in ganglion cell-inner plexiform layer (GCIPL) thickness in a healthy cohort from widefield optical coherence tomography (OCT) scans. METHODS: Widefield OCT scans spanning 55° × 45° were acquired from 470 healthy eyes. The GCIPL was automatically segmented using deep learning methods. Thickness measurements were extracted after correction for warpage and retinal tilt. Multiple linear regression analysis was applied to discern trends between global GCIPL thickness and age, axial length and sex. To further characterise age-related change, hierarchical and two-step cluster algorithms were applied to identify locations sharing similar ageing properties, and rates of change were quantified using regression analyses with data pooled by cluster analysis outcomes. RESULTS: Declines in widefield GCIPL thickness with age, increasing axial length and female sex were observed (parameter estimates -0.053, -0.436 and -0.464, p-values <0.001, <0.001 and 0.02, respectively). Cluster analyses revealed concentric, slightly nasally displaced, horseshoe patterns of age-related change in the GCIPL, with up to four statistically distinct clusters outside the macula. Linear regression analyses revealed significant ageing decline in GCIPL thickness across all clusters, with faster rates of change observed at central locations when expressed as absolute (slope = -0.19 centrally vs. -0.04 to -0.12 peripherally) and percentage rates of change (slope = -0.001 centrally vs. -0.0005 peripherally). CONCLUSIONS: Normative variations in GCIPL thickness from widefield OCT with age, axial length and sex were noted, highlighting factors worth considering in further developments. Widefield OCT has promising potential to facilitate quantitative detection of abnormal GCIPL outside standard fields of view.


Asunto(s)
Mácula Lútea , Tomografía de Coherencia Óptica , Humanos , Femenino , Tomografía de Coherencia Óptica/métodos , Células Ganglionares de la Retina , Fibras Nerviosas , Retina
6.
Clin Exp Optom ; 107(2): 171-183, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38057282

RESUMEN

CLINICAL RELEVANCE: A method for determining 10-2 deployment in glaucoma with the goal of detecting additional visual field sensitivity for the purpose of functional monitoring is proposed. BACKGROUND: To provide a pilot method for determining when to deploy the 10-2 visual field (VF) test grid in glaucoma by characterising the 'functional vulnerability zone'. METHODS: The cross-sectional 24-2 (central 12 locations) and 10-2 VF results from 133 eyes of 133 glaucoma subjects were used to describe the central Hill of Vision using VF sensitivity. The 'volume' (defined using arbitrary units, A.U.) under the Hill was calculated. A greater A.U. on the 10-2 indicated a functional vulnerability zone (FVZ), signifying additional clinical dynamic range for potential future monitoring. The main outcome measures were calculated A.U. and 24-2 factors which were significantly related to A.U. differences between 24-2 and 10-2. RESULTS: Over 55% of patients had an FVZ (A.U. greater using 10-2). Several 24-2 features (worse mean deviation, worse central 24-2 mean defect, and a higher proportion of defective locations) were significant in the FVZ cohort compared to non-FVZ. 24-2 mean deviation levels at which 10-2 may be favoured were low at -3.16 to -3.62 dB. Specifically, 5 or more defective central 24-2 test locations were associated with an FVZ. Subjects exhibiting a less severe defect on the 10-2 were more likely to have an FVZ, indicating its potential for future VF monitoring. CONCLUSIONS: The authors propose several clinical markers, focussing on the 24-2, which can guide clinicians on when the 10-2 may have utility in glaucoma assessment. The authors provide a pilot reference spreadsheet for clinicians to visualise the likelihood of 10-2 utility in the context of an FVZ.


Asunto(s)
Glaucoma , Campos Visuales , Humanos , Pruebas del Campo Visual/métodos , Estudios Transversales , Glaucoma/diagnóstico , Ojo , Trastornos de la Visión/diagnóstico , Presión Intraocular
7.
Clin Exp Optom ; 107(2): 130-146, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37674264

RESUMEN

Artificial Intelligence is a rapidly expanding field within computer science that encompasses the emulation of human intelligence by machines. Machine learning and deep learning - two primary data-driven pattern analysis approaches under the umbrella of artificial intelligence - has created considerable interest in the last few decades. The evolution of technology has resulted in a substantial amount of artificial intelligence research on ophthalmic and neurodegenerative disease diagnosis using retinal images. Various artificial intelligence-based techniques have been used for diagnostic purposes, including traditional machine learning, deep learning, and their combinations. Presented here is a review of the literature covering the last 10 years on this topic, discussing the use of artificial intelligence in analysing data from different modalities and their combinations for the diagnosis of glaucoma and neurodegenerative diseases. The performance of published artificial intelligence methods varies due to several factors, yet the results suggest that such methods can potentially facilitate clinical diagnosis. Generally, the accuracy of artificial intelligence-assisted diagnosis ranges from 67-98%, and the area under the sensitivity-specificity curve (AUC) ranges from 0.71-0.98, which outperforms typical human performance of 71.5% accuracy and 0.86 area under the curve. This indicates that artificial intelligence-based tools can provide clinicians with useful information that would assist in providing improved diagnosis. The review suggests that there is room for improvement of existing artificial intelligence-based models using retinal imaging modalities before they are incorporated into clinical practice.


Asunto(s)
Glaucoma , Enfermedades Neurodegenerativas , Humanos , Inteligencia Artificial , Enfermedades Neurodegenerativas/diagnóstico por imagen , Glaucoma/diagnóstico , Aprendizaje Automático , Sensibilidad y Especificidad
8.
Ophthalmology ; 131(6): 658-666, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38110124

RESUMEN

PURPOSE: The newly released Swedish Interactive Thresholding Algorithm (SITA)-Faster (SFR) has significantly shorter testing durations compared with older SITA algorithms, but its variability is uncertain. This study quantified and established threshold limits of test-retest variability across the 24-2 test grid using SFR. DESIGN: Cross-sectional study with prospective longitudinal arm. PARTICIPANTS: 1426 eyes of 787 patients with healthy, suspected glaucoma, or manifest glaucoma eyes from hospital- and university- eye clinics. METHODS: Two SFR tests per eye at a baseline visit and at two follow-up visits. MAIN OUTCOME MEASURES: Pointwise variability measured by test-retest difference in pointwise sensitivity between tests one and two, mean global variability (test-retest variance) measured by average of pointwise variability for each participant, global sensitivity, and reliability indices of each eye. RESULTS: Of the 1426 eyes, 540 eyes (37.9%) had a diagnosis of glaucoma, 753 eyes (52.8%) were suspected of having glaucoma, and the remaining 133 eyes (9.3%) were healthy. Of 74 152 pointwise sensitivities obtained, the mean test-retest difference was 2.17 ± 2.9 dB, whereas the mean test-retest variance for each participant was 2.17 ± 1.2 dB. Pointwise and global variability increased with worsening threshold sensitivity and (MD), respectively, and was greater for peripheral compared with central test locations. In the longitudinal cohort, no significant difference in mean test-retest variance was found across the 3 visits (mean variability, 2.10 dB vs. 2.16 dB vs. 2.16 dB at visits F0 vs. F1 vs. F2; P = 0.53, repeated-measures analysis of variance). Baseline MD (-0.19 dB; 95% CI, -0.22 to 0.16 dB; P < 0.0001) and abnormally high sensitivity on glaucoma hemifield test (1.14 dB; 95% CI, 0.78-1.51 dB; P < 0.0001) were significantly associated with increased variability. Finally, test-retest MD showed minimal change around the recommended 15% false-positive cutoff threshold. CONCLUSIONS: The variability of SFR increases with worsening threshold sensitivity, is stable over time, and is greater for peripheral compared with central test locations. Worse baseline MD and abnormally high sensitivity are significant predictors of increased variability. A cutoff of 15% in false-positive results may be inappropriate as a threshold for judging test reliability in SFR. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Asunto(s)
Algoritmos , Presión Intraocular , Hipertensión Ocular , Pruebas del Campo Visual , Campos Visuales , Humanos , Campos Visuales/fisiología , Masculino , Estudios Prospectivos , Femenino , Estudios Transversales , Pruebas del Campo Visual/métodos , Persona de Mediana Edad , Presión Intraocular/fisiología , Anciano , Reproducibilidad de los Resultados , Hipertensión Ocular/diagnóstico , Hipertensión Ocular/fisiopatología , Trastornos de la Visión/diagnóstico , Trastornos de la Visión/fisiopatología , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Sensibilidad y Especificidad , Adulto , Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Ángulo Abierto/fisiopatología , Umbral Sensorial/fisiología
9.
Ophthalmic Physiol Opt ; 44(1): 83-95, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37803502

RESUMEN

PURPOSE: To compare clinical visual field outputs in glaucoma and healthy patients returned by the Humphrey Field Analyzer (HFA) and virtual reality (Virtual Field, VF) perimetry. METHODS: One eye of 54 glaucoma patients and 41 healthy subjects was prospectively tested (three times each in random order) using the HFA and VF perimeters (24-2 test grids). We extracted and compared global indices (mean deviation [MD] and pattern standard deviation [PSD]), pointwise sensitivity (and calculated 'equivalent' sensitivity after accounting for differences in background luminance) and pointwise defects. Bland-Altman (mean difference [Mdiff ] and 95% limits of agreement [LoA]) and intraclass correlation analyses were performed. RESULTS: The VF test was shorter (by 76 s) and had lower fixation losses (by 0.08) and false-positive rate (by 0.01) compared to the HFA (all p < 0.0001). Intraclass correlations were 0.86, 0.82 and 0.47 for MD, PSD and pointwise sensitivity between devices, respectively. Test-retest variability was higher for VF (Mdiff 0.3 dB, LoA -7.6 to 8.2 dB) compared to the HFA (Mdiff -0.3 dB, LoA -6.4 to 5.9 dB), indicating greater test-retest variability. When using each device's underlying normative database, the HFA detected, on average, 7 more defects (at the p < 0.05 level) out of the 52 test locations compared to this iteration of VF in the glaucoma cohort. CONCLUSIONS: Virtual Field returns global results that are correlated with the HFA, but pointwise sensitivities were more variable. Differences in test-retest variability and defect detection by its current normative database raise questions about the widespread adoption of VF in lieu of the HFA.


Asunto(s)
Glaucoma , Realidad Virtual , Humanos , Pruebas del Campo Visual/métodos , Campos Visuales , Sensibilidad y Especificidad , Reproducibilidad de los Resultados , Glaucoma/diagnóstico
10.
Can J Ophthalmol ; 2023 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-37652089

RESUMEN

OBJECTIVE: To determine the effect of frontloading (multiple) visual field (VF) tests at the same visit for detecting mean deviation (MD) change in slowly progressive glaucoma. METHODS: This was a computer simulation study. Baseline MD (range, 0 to -12 dB) and progression rate (range, 0 to -0.4 dB/year, non-inclusive) were generated for 10,000 patients. Each patient had 6 simulated "stable" baseline VF tests. Then follow-up VFs (up to 10 years) were generated by incorporating progression rate and within-visit and between-visit variability. The independent variables were number of VF tests per visit (one non-frontloaded or two frontloaded), VF reliability (100%, 85%, or 70%), repeat testing because of unreliable results (yes or no), and follow-up interval (6-monthly or yearly). The outcomes were detection of progression (MD slope that was negative and significant at p < 0.05), MD at detection, and number of years to detection. RESULTS: Frontloading identified more progressors (62.7%-79.2%) compared with non-frontloading (31.0%-36.7%) at 10 years (p < 0.0001). Six-monthly follow-ups led to greater detection than yearly intervals. Progressors detected by both methods were detected by the non-frontloaded method sooner (up to 0.26 years), but this was small and not clinically significant (MD difference, 0.06 dB). An increase (less severe) in MD, an increase (slower) in progression rate, and an increase in SD of baseline VFs decreased the likelihood of detecting progression. CONCLUSIONS: Frontloading VF tests at 6-monthly intervals improve detection rates of MD progression in slowly progressive glaucoma patients compared with performing 1 test per visit at yearly intervals.

11.
Ophthalmology ; 130(11): 1138-1148, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37385298

RESUMEN

PURPOSE: Frontloading SITA-Faster (SFR) visual fields (2 tests per eye on the same visit) has been shown to provide repeatable perimetric data at minimal time cost. This study reports the outcomes of using frontloaded SFR in the evaluation of pointwise visual field (VF) defects in a cohort of patients with glaucoma when transitioned from SITA-Standard (SS). DESIGN: Prospective, cross-sectional study. PARTICIPANTS: A total of 144 eyes of 91 patients with confirmed or suspected glaucoma who had an SS test on a previous visit. METHODS: Two SFR tests (T1, T2) per eye on the same visit. MAIN OUTCOME MEASURES: Global sensitivity, reliability indices, and pointwise deviation map probability scores from the pattern deviation grid of each patient were compared across the 3 sequential tests to evaluate the consistency of VF defects. RESULTS: The mean age was 68.6 years, and 79.2% of patients had a diagnosis of glaucoma. There was no significant difference in mean deviation (MD) across the 3 tests (-5.83 decibels [dB], -5.28 dB, and -5.71 dB in SS, SFR1, and SFR2, respectively, repeated-measures analysis of variance [ANOVA], P = 0.48). The frontloaded SFR tests provided repeatable VFs that confirmed existing pointwise data on the SS in 4661 (62.3%) locations, reversed an SS defect in 614 (8.2%) locations, and demonstrated a new repeatable defect in 406 (5.4%) locations of the pattern deviation grid. A new defect of at least 3 contiguous points was identified in 20.1% of eyes. The non-repeatable points on the 2 SFR tests displayed no significant difference in the distribution of defect/nondefect points based on test order or peripheral versus central locations. There was no significant difference in the rate of obtaining at least 1 reliable test result between SS and the frontloaded SFR T1 and T2 (P = 0.77). Test duration significantly decreased from SS to SFR1/2 (379 vs. 160 vs. 158 seconds, P < 0.0001). CONCLUSIONS: Frontloading SFR tests can provide repeatable data for the evaluation of the consistency of pattern deviation defects in glaucoma, with no observable decline in performance from test fatigue. This is achieved at equivalent duration and reliability as a single SS test. Frontloading SFR may be helpful in increasing testing frequency/quantity to meet recommended guidelines for progression analysis. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

12.
Ophthalmic Physiol Opt ; 43(4): 771-787, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36964934

RESUMEN

PURPOSE: To determine whether there are quantifiable structural or functional differences that can distinguish between high-tension glaucoma (HTG; intraocular pressure [IOP] > 21 mm Hg) and low-tension glaucoma (LTG; IOP ≤ 21 mm Hg) at diagnosis. METHOD: This was a retrospective, cross-sectional study. Clinical results of one eye from 90 newly diagnosed HTG and 319 newly diagnosed LTG patients (117 with very-low-tension glaucoma [vLTG; ≤15 mm Hg] and 202 with middling LTG [mLTG; >15 mm Hg, ≤21 mm Hg]) were extracted, which included relevant demographic covariates of glaucoma, quantitative optical coherence tomography (including the optic nerve head, retinal nerve fibre layer and ganglion cell-inner plexiform layer) measurements and standard automated perimetry global metrics. We used binary logistic regression analysis to identify statistically significant clinical parameters distinguishing between phenotypic groups for inclusion in principal component (PC) (factor) analysis (PCA). The separability between each centroid for each cohort was calculated using the Euclidean distance (d(x,y)). RESULTS: The binary logistic regression comparing HTG and all LTG identified eight statistically significant clinical parameters. Subsequent PCA results included three PCs with an eigenvalue >1. PCs 1 and 2 accounted for 21.2% and 20.2% of the model, respectively, with a d(x,y) = 0.468, indicating low separability between HTG and LTG. The analysis comparing vLTG, mLTG and HTG identified 15 significant clinical parameters, which were subsequently grouped into five PCs. PCs 1 and 2 accounted for 24.1% and 17.8%, respectively. The largest separation was observed between vLTG and HTG (d(x,y) = 0.581), followed by vLTG and mLTG (d(x,y) = 0.435) and lastly mLTG and HTG (d(x,y) = 0.210). CONCLUSION: Conventional quantitative structural or functional parameters could not distinguish between pressure-defined glaucoma phenotypes at the point of diagnosis and are therefore not contributory to separating cohorts. The overlap in findings highlights the heterogeneity of the primary open-angle glaucoma clinical presentations among pressure-defined groups at the cohort level.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Humanos , Glaucoma de Ángulo Abierto/diagnóstico , Estudios Transversales , Estudios Retrospectivos , Células Ganglionares de la Retina , Presión Intraocular , Pruebas del Campo Visual , Tomografía de Coherencia Óptica/métodos
13.
Eye (Lond) ; 37(15): 3128-3136, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36922645

RESUMEN

OBJECTIVE: We aim to quantify the co-existence of age-related macular degeneration (AMD), glaucoma, or diabetic retinopathy (DR) and cognitive impairment or dementia. METHOD: MEDLINE, EMBASE, PsycINFO and CINAHL were searched (to June 2020). Observational studies reporting incidence or prevalence of AMD, glaucoma, or DR in people with cognitive impairment or dementia, and of cognitive impairment or dementia among people with AMD, glaucoma, or DR were included. RESULTS: Fifty-six studies (57 reports) were included but marked by heterogeneities in the diagnostic criteria or definitions of the diseases, study design, and case mix. Few studies reported on the incidence. Evidence was sparse but consistent in individuals with mild cognitive impairment where 7.7% glaucoma prevalence was observed. Prevalence of AMD and DR among people with cognitive impairment ranged from 3.9% to 9.4% and from 11.4% to 70.1%, respectively. Prevalence of AMD and glaucoma among people with dementia ranged from 1.4 to 53% and from 0.2% to 25.9%, respectively. Prevalence of DR among people with dementia was 11%. Prevalence of cognitive impairment in people with AMD, glaucoma, and DR ranged from 8.4% to 52.4%, 12.3% to 90.2%, and 3.9% to 77.8%, respectively, and prevalence of dementia in people with AMD, glaucoma and DR ranged from 9.9% to 62.6%, 2.5% to 3.3% and was 12.5%, respectively. CONCLUSIONS: Frequency of comorbid eye disease and cognitive impairment or dementia varied considerably. While more population-based estimations of the co-existence are needed, interdisciplinary collaboration might be helpful in the management of these conditions to meet healthcare needs of an ageing population. TRIAL REGISTRATION: PROSPERO registration: CRD42020189484.


Asunto(s)
Disfunción Cognitiva , Demencia , Retinopatía Diabética , Glaucoma , Degeneración Macular , Humanos , Disfunción Cognitiva/epidemiología , Disfunción Cognitiva/complicaciones , Glaucoma/complicaciones , Glaucoma/epidemiología , Envejecimiento , Retinopatía Diabética/complicaciones , Demencia/epidemiología , Demencia/complicaciones
14.
Ophthalmol Glaucoma ; 6(5): 445-456, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36958625

RESUMEN

PURPOSE: To report the outcomes of frontloaded visual field (VF) testing (2 tests per eye on the same visit) over 2 longitudinal, consecutive visits using SITA-Faster (SFR) in terms of global indices, reliability metrics, and test duration. DESIGN: Prospective longitudinal study. SUBJECTS: A total of 902 eyes of 463 subjects with normal, suspect, or manifest glaucoma. METHODS: Two intravisit SFR VF tests (T1 and T2) per eye at an initial (Ti) and follow-up (Tf) visit. MAIN OUTCOME MEASURES: Intra- and intervisit global indices, reliability metrics, and test durations. RESULTS: The mean age of the subjects was 63.6 years, and 58.3% were male. Seven hundred ninety eyes (87.4%) had a diagnosis of glaucoma or glaucoma suspicion. The mean duration between visits was 265.0 (standard deviation 98.8) days. In total, 3608 VF tests were analyzed, with the correlation of mean deviation (MD) values of the frontloaded tests at each visit high (T1/T2 MD correlation at initial visit r = 0.83, root mean squared error [RMSE] = 1.26, follow-up visit r = 0.83, RMSE = 1.25, P < 0.0001) and greater than the correlation of MD between visits (Ti1/Tf1 MD correlation r = 0.72, RMSE = 1.31). There was a significant intra-visit decrease in rates of abnormally high sensitivity in the glaucoma hemifield test (3.2% vs. 1.6%, P = 0.0023) and rates of unreliable test results (15.4% vs. 9.2%, P = 0.002) from T1 to T2 in both visits, with a corresponding significant decrease in MD (-1.28 dB vs. -1.68 dB, P < 0.0001) and VF index (P = 0.03). The mean duration of each SFR test was 132.6 (SD 27.2) seconds. CONCLUSIONS: Frontloading VFs using SFR produced sets of repeatable perimetric data with significant improvement of reliability indices from the first to second test. This may help increase testing frequency at minimal time cost to meet recommended guidelines and for evaluating patients prone to high variability. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Asunto(s)
Glaucoma , Campos Visuales , Humanos , Masculino , Persona de Mediana Edad , Femenino , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Longitudinales , Trastornos de la Visión/diagnóstico , Pruebas del Campo Visual/métodos , Glaucoma/diagnóstico
15.
Ophthalmic Physiol Opt ; 43(1): 46-63, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36416369

RESUMEN

PURPOSE: To analyse optical coherence tomography (OCT)-derived inner nuclear layer (INL) and outer retinal complex (ORC) measurements relative to ganglion cell-inner plexiform layer (GCIPL) measurements in glaucoma. METHODS: Glaucoma participants (n = 271) were categorised by 10-2 visual field defect type. Differences in GCIPL, INL and ORC thickness were calculated between glaucoma and matched healthy eyes (n = 548). Hierarchical cluster algorithms were applied to generate topographic patterns of retinal thickness change, with agreement between layers assessed using Cohen's kappa (κ). Differences in GCIPL, INL and ORC thickness within and outside GCIPL regions showing the greatest reductions and Spearman's correlations between layer pairs were compared with 10-2 mean deviation (MD) and pattern standard deviation (PSD) to determine trends with glaucoma severity. RESULTS: Glaucoma participants with inferior and superior defects presented with concordant GCIPL and INL defects demonstrating mostly fair-to-moderate agreement (κ = 0.145-0.540), which was not observed in eyes with no or ring defects (κ = -0.067-0.230). Correlations (r) with MD and PSD were moderate and weak in GCIPL and INL thickness differences, respectively (GCIPL vs. MD r = 0.479, GCIPL vs. PSD r = -0.583, INL vs. MD r = 0.259, INL vs. PSD r = -0.187, p = <0.0001-0.002), and weak in GCIPL-INL correlations (MD r = 0.175, p = 0.004 and PSD r = 0.154, p = 0.01). No consistent patterns in ORC thickness or correlations were observed. CONCLUSIONS: In glaucoma, concordant reductions in macular INL and GCIPL thickness can be observed, but reductions in ORC thickness appear unlikely. These findings suggest that trans-synaptic retrograde degeneration may occur in glaucoma and could indicate the usefulness of INL thickness in evaluating glaucomatous damage.


Asunto(s)
Glaucoma , Tomografía de Coherencia Óptica , Humanos , Glaucoma/diagnóstico
17.
Ophthalmic Physiol Opt ; 42(5): 973-985, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35598152

RESUMEN

PURPOSE: To determine the usefulness of Humphrey Field Analyser (HFA) SITA-Faster 24-2 gaze tracker outputs on interpreting intra-visit visual field (VF) result pairs. METHODS: Analysis of 1380 right-left eye pairs and 1432 pairs of test 1-test 2 intrasession VF results of patients seen within a university-based glaucoma service was undertaken to understand gaze deviation distributions. Output gaze tracker results were aggregated into total ticks, sum of amplitudes and average amplitudes. Correlations between visual field indices (mean deviation [MD], "events" and overall hill of vision) and independent variables (age and test order) were performed using one eye from each subject. RESULTS: There was no association of test order (right-left, test 1-test 2) with eye movements. There was a significant, but weak correlation between eye movements and age (r = 0.16). Correlations of eye movements with MD were driven by more severe MD values. There were no significant correlations between intrasession difference in eye movements and the change in MD, number of "events" and hill of vision, or in the root mean square of sensitivity and total deviation values. There was also no significant correlation between gaze tracker outputs and another commonly used "reliability" metric, false positive rate. CONCLUSIONS: Eye movement parameters as currently reported by the HFA do not appear to be correlated with key sensitivity parameters when considering the repeatability of intrasession SITA-Faster 24-2 VF results. Thus, current gaze tracker outputs do not appear to provide clinically meaningful information for interpretation of intra-visit visual field results that cannot already be garnered using other strategies.


Asunto(s)
Glaucoma , Campos Visuales , Ojo , Movimientos Oculares , Humanos , Reproducibilidad de los Resultados , Trastornos de la Visión/diagnóstico , Pruebas del Campo Visual/métodos
18.
Transl Vis Sci Technol ; 11(5): 13, 2022 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-35575777

RESUMEN

Purpose: To compare various displacement models using midget retinal ganglion cell to cone (mRGC:C) ratios and to determine viability of estimating RGC counts from optical coherence tomography (OCT)-derived ganglion cell-inner plexiform layer (GCIPL) measurements. Methods: Four Drasdo model variations were applied to macular visual field (VF) stimulus locations: (1) using meridian-specific Henle fiber length along the stimulus circumference; (2) using meridian-specific differences in RGC receptive field and counts along the stimulus circumference; (3) per method (2), averaged across principal meridians; and (4) per method (3), with the stimulus center displaced only. The Sjöstrand model was applied (5) along the stimulus circumference and (6) to the stimulus center only. Eccentricity-dependent mRGC:C ratios were computed over displaced areas, with comparisons to previous models using sum of squares of the residuals (SSR) and root mean square error (RMSE). RGC counts estimated from OCT-derived ganglion cell layer (GCL) and GCIPL measurements, from 143 healthy participants, were compared using Bland-Altman analyses. Results: Methods 1, 2, and 5 produced mRGC:C ratios most consistent with previous models (SSR 3.82, 4.07, and 3.02; RMSE 0.22, 0.23, and 0.20), while central mRGC:C ratios were overestimated by method 3 and underestimated by methods 4 and 6. RGC counts predicted from GCIPL measurements were within 16% of GCL-based counts, with no notable bias with increasing RGC counts. Conclusions: Sjöstrand displacement and meridian-specific Drasdo displacement applied to VF stimulus circumferences produce mRGC:C ratios consistent with previous models. RGC counts can be estimated from OCT-derived GCIPL measurements. Translational Relevance: Implementing appropriate displacement methods and deriving RGC estimates from relevant OCT parameters enables calculation of the number of RGCs responding to VF stimuli from commercial instrumentation.


Asunto(s)
Células Ganglionares de la Retina , Tomografía de Coherencia Óptica , Humanos , Fibras Nerviosas , Retina , Tomografía de Coherencia Óptica/métodos , Campos Visuales
19.
Transl Vis Sci Technol ; 11(4): 18, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35438719

RESUMEN

Purpose: The purpose of this study was to compare concordance between ganglion cell-inner plexiform layer (GCIPL) data from the Cirrus optical coherence tomographer (OCT) Ganglion Cell Analysis (GCA) and visual fields (VFs), with and without Drasdo displacement. Methods: From 296 open-angle glaucoma participants, GCIPL deviation and raw thickness data were extracted over locations per the 10-2 VF test grid, with and without application of Drasdo displacement, with global and eccentricity-dependent sensitivities and specificities calculated for both. With OCT and VF data classified as within or outside normative limits, pattern deviation values were compared using paired t-tests and Spearman correlations. Regression models were applied to pattern deviation values as a function of GCIPL thickness, and differences in model performance with and without displacement were compared using extra sums-of-squares F tests. Results: There were small but significant improvements in global specificity without displacement (0.58-0.59 with displacement and 0.61 without displacement), without notable differences in sensitivity (0.77-0.78 with displacement and 0.76-0.78 without displacement). At abnormal VF locations and without displacement, a higher proportion of correct OCT classifications (P = 0.0008) and significant correlation with worsening pattern deviation values were observed (r = 0.50, P = 0.002). Regression models indicated significantly steeper slopes with Drasdo displacement centrally (P = 0.002-0.04). Conclusions: With GCA deviation maps, small improvements in structure-function concordance were observed without displacement, which are unlikely to be clinically meaningful. Using GCIPL thickness data, significantly better structure-function concordance was observed centrally with Drasdo displacement. Translational Relevance: Applying Drasdo displacement on probability-based reports is unlikely to alter clinical impressions of structure-function concordance, but applying displacement with GCIPL thickness data may improve detection of structure-function concordance.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma de Ángulo Abierto/diagnóstico , Humanos , Presión Intraocular , Fibras Nerviosas , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica
20.
Transl Vis Sci Technol ; 11(2): 20, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-35142783

RESUMEN

PURPOSE: The purpose of this study was to evaluate the impact of two conventional reliability criteria (false positives [FPs] and seeding point errors [SPEs]) and the concurrent effect of low sensitivity points (≤19 dB) on intrasession SITA-Faster visual field (VF) result correlations. METHODS: There were 2320 intrasession SITA-Faster VF results from 1160 eyes of healthy, glaucoma suspects, and subjects with glaucoma that were separated into "both reliable" or "reliable-unreliable" pairs. VF results (mean deviation and pointwise sensitivity) were analyzed against the spectrum of FP rates and SPE, with and without censorship of sensitivity results ≤19 dB. Segmental linear regression was used to identify critical points where visual field results were significantly different between tests due to FP levels. RESULTS: There was a significant, but small (0.09 dB per 1% exceeding 12%) increase in mean deviation, and an increase in the number of points showing a >3 dB sensitivity increase (0.25-0.28 locations per 1% exceeding 12%). SPEs were almost exclusively related to a decrease in sensitivity at the primary seeding points but did not result in significant differences in other indices. Censoring sensitivity results ≤19 dB significantly improved the correlation between reliable and unreliable results. CONCLUSIONS: Current criteria for judging an unreliable VF result (FP rate >15% and SPE) can lead to data being erroneously excluded, as many results do not show significant differences compared to those deemed "reliable." Censoring of sensitivity results ≤19 dB improves intrasession correlations in VF results. TRANSLATIONAL RELEVANCE: We provide guidelines for assessing the impact of FP, SPE, and low sensitivity results on VF interpretation.


Asunto(s)
Glaucoma , Campos Visuales , Glaucoma/diagnóstico , Humanos , Presión Intraocular , Reproducibilidad de los Resultados , Trastornos de la Visión , Pruebas del Campo Visual/métodos