Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Eur Heart J Cardiovasc Imaging ; 24(11): 1430-1443, 2023 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-37395329

RESUMEN

In this EACVI clinical scientific update, we will explore the current use of multi-modality imaging in the diagnosis, risk stratification, and follow-up of patients with aortic stenosis, with a particular focus on recent developments and future directions. Echocardiography is and will likely remain the key method of diagnosis and surveillance of aortic stenosis providing detailed assessments of valve haemodynamics and the cardiac remodelling response. Computed tomography (CT) is already widely used in the planning of transcutaneous aortic valve implantation. We anticipate its increased use as an anatomical adjudicator to clarify disease severity in patients with discordant echocardiographic measurements. CT calcium scoring is currently used for this purpose; however, contrast CT techniques are emerging that allow identification of both calcific and fibrotic valve thickening. Additionally, improved assessments of myocardial decompensation with echocardiography, cardiac magnetic resonance, and CT will become more commonplace in our routine assessment of aortic stenosis. Underpinning all of this will be widespread application of artificial intelligence. In combination, we believe this new era of multi-modality imaging in aortic stenosis will improve the diagnosis, follow-up, and timing of intervention in aortic stenosis as well as potentially accelerate the development of the novel pharmacological treatments required for this disease.


Asunto(s)
Estenosis de la Válvula Aórtica , Inteligencia Artificial , Humanos , Consenso , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Imagen Multimodal
3.
Circ Cardiovasc Imaging ; 14(11): e012809, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34743529

RESUMEN

BACKGROUND: Low rest transaortic flow rate (FR) has been shown previously to predict mortality in low-gradient aortic stenosis. However limited prognostic data exists on stress FR during low-dose dobutamine stress echocardiography. We aimed to assess the value of stress FR for the detection of aortic valve stenosis (AS) severity and the prediction of mortality. METHODS: This is a multicenter cohort study of patients with reduced left ventricular ejection fraction and low-gradient aortic stenosis (aortic valve area <1 cm2 and mean gradient <40 mm Hg) who underwent low-dose dobutamine stress echocardiography to identify the AS severity and presence of flow reserve. The outcome assessed was all-cause mortality. RESULTS: Of the 287 patients (mean age, 75±10 years; males, 71%; left ventricular ejection fraction, 31±10%) over a mean follow-up of 24±30 months there were 127 (44.3%) deaths and 147 (51.2%) patients underwent aortic valve intervention. Higher stress FR was independently associated with reduced risk of mortality (hazard ratio, 0.97 [95% CI, 0.94-0.99]; P=0.01) after adjusting for age, chronic kidney disease, heart failure symptoms, aortic valve intervention, and rest left ventricular ejection fraction. The minimum cutoff for prediction of mortality was stress FR 210 mL/s. Following adjustment to the same important clinical and echocardiographic parameters, among the three criteria of AS severity during stress, ie, the guideline definition of aortic valve area <1cm2 and aortic valve mean gradient ≥40 mm Hg, or aortic valve mean gradient ≥40 mm Hg, or the novel definition of aortic valve area <1 cm2 at stress FR ≥210 mL/s, only the latter was independently associated with mortality (hazard ratio, 1.72 [95% CI, 1.05-2.82]; P=0.03). Furthermore aortic valve area <1cm2 at stress FR ≥210 mL/s was the only severe aortic stenosis criterion that was associated with improved outcome following aortic valve intervention (P<0.001). Guideline-defined stroke volume flow reserve did not predict mortality. CONCLUSIONS: Stress FR during low-dose dobutamine stress echocardiography was useful for the detection of both AS severity and flow reserve and was associated with improved prediction of outcome following aortic valve intervention.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Dobutamina/farmacología , Ecocardiografía de Estrés/métodos , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Anciano , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Cardiotónicos/farmacología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad
4.
J Am Coll Cardiol ; 78(6): 545-558, 2021 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-34353531

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly used for risk stratification in aortic stenosis (AS). However, the relative prognostic power of CMR markers and their respective thresholds remains undefined. OBJECTIVES: Using machine learning, the study aimed to identify prognostically important CMR markers in AS and their thresholds of mortality. METHODS: Patients with severe AS undergoing AVR (n = 440, derivation; n = 359, validation cohort) were prospectively enrolled across 13 international sites (median 3.8 years' follow-up). CMR was performed shortly before surgical or transcatheter AVR. A random survival forest model was built using 29 variables (13 CMR) with post-AVR death as the outcome. RESULTS: There were 52 deaths in the derivation cohort and 51 deaths in the validation cohort. The 4 most predictive CMR markers were extracellular volume fraction, late gadolinium enhancement, indexed left ventricular end-diastolic volume (LVEDVi), and right ventricular ejection fraction. Across the whole cohort and in asymptomatic patients, risk-adjusted predicted mortality increased strongly once extracellular volume fraction exceeded 27%, while late gadolinium enhancement >2% showed persistent high risk. Increased mortality was also observed with both large (LVEDVi >80 mL/m2) and small (LVEDVi ≤55 mL/m2) ventricles, and with high (>80%) and low (≤50%) right ventricular ejection fraction. The predictability was improved when these 4 markers were added to clinical factors (3-year C-index: 0.778 vs 0.739). The prognostic thresholds and risk stratification by CMR variables were reproduced in the validation cohort. CONCLUSIONS: Machine learning identified myocardial fibrosis and biventricular remodeling markers as the top predictors of survival in AS and highlighted their nonlinear association with mortality. These markers may have potential in optimizing the decision of AVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrosis/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas , Imagen por Resonancia Cinemagnética , Miocardio/patología , Remodelación Ventricular , Anciano , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Técnicas de Imagen Cardíaca/métodos , Femenino , Pruebas de Función Cardíaca/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Aprendizaje Automático , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Cinemagnética/estadística & datos numéricos , Masculino , Pronóstico , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Índice de Severidad de la Enfermedad , Análisis de Supervivencia
5.
J Am Coll Cardiol ; 75(3): 304-316, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31976869

RESUMEN

BACKGROUND: Myocardial fibrosis is a key mechanism of left ventricular decompensation in aortic stenosis and can be quantified using cardiovascular magnetic resonance (CMR) measures such as extracellular volume fraction (ECV%). Outcomes following aortic valve intervention may be linked to the presence and extent of myocardial fibrosis. OBJECTIVES: This study sought to determine associations between ECV% and markers of left ventricular decompensation and post-intervention clinical outcomes. METHODS: Patients with severe aortic stenosis underwent CMR, including ECV% quantification using modified Look-Locker inversion recovery-based T1 mapping and late gadolinium enhancement before aortic valve intervention. A central core laboratory quantified CMR parameters. RESULTS: Four-hundred forty patients (age 70 ± 10 years, 59% male) from 10 international centers underwent CMR a median of 15 days (IQR: 4 to 58 days) before aortic valve intervention. ECV% did not vary by scanner manufacturer, magnetic field strength, or T1 mapping sequence (all p > 0.20). ECV% correlated with markers of left ventricular decompensation including left ventricular mass, left atrial volume, New York Heart Association functional class III/IV, late gadolinium enhancement, and lower left ventricular ejection fraction (p < 0.05 for all), the latter 2 associations being independent of all other clinical variables (p = 0.035 and p < 0.001). After a median of 3.8 years (IQR: 2.8 to 4.6 years) of follow-up, 52 patients had died, 14 from adjudicated cardiovascular causes. A progressive increase in all-cause mortality was seen across tertiles of ECV% (17.3, 31.6, and 52.7 deaths per 1,000 patient-years; log-rank test; p = 0.009). Not only was ECV% associated with cardiovascular mortality (p = 0.003), but it was also independently associated with all-cause mortality following adjustment for age, sex, ejection fraction, and late gadolinium enhancement (hazard ratio per percent increase in ECV%: 1.10; 95% confidence interval [1.02 to 1.19]; p = 0.013). CONCLUSIONS: In patients with severe aortic stenosis scheduled for aortic valve intervention, an increased ECV% is a measure of left ventricular decompensation and a powerful independent predictor of mortality.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Líquido Extracelular/fisiología , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Imagen por Resonancia Cinemagnética/métodos , Masculino , Persona de Mediana Edad , Mortalidad/tendencias , Miocardio/patología , Estudios Prospectivos , Disfunción Ventricular Izquierda/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...