1.
Respir Care ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38729663

RESUMEN

Non-invasive respiratory support delivered through a face mask has become a cornerstone treatment for adults and children with acute or chronic respiratory failure. However, an imperfect mask fit using commercially available interfaces is frequently encountered, which may result in patient discomfort and treatment inefficiency or failure. To overcome this challenge, over the last decade increasing attention has been given to the development of personalized face masks, which are custom made to address the specific facial dimensions of an individual patient. With this scoping review we aim to provide a comprehensive overview of the current advances and gaps in knowledge regarding the personalization of ventilation masks. We performed a systematic search of the literature, and identified and summarized a total of 23 studies. Most studies included were involved in the development of nasal masks. Studies targeting adult respiratory care mainly focused on chronic (home) ventilation and included some clinical testing in a relevant subject population. In contrast, pediatric studies focused mostly on respiratory support in the acute setting, while testing was limited to bench or case studies only. Most studies were positive regarding the performance (i.e. comfort, level of air leak and mask pressure applied to the skin) of personalized masks in bench testing or in human, healthy or patient, subjects. Advances in the field of 3D scanning and soft material printing were identified, but important gaps in knowledge remain. In particular, more insight into cushion materials, headgear design, clinical feasibility and cost-effectiveness is needed, before definite recommendations can be made regarding implementation of large scale clinical programs that personalize non-invasive respiratory support masks for adults and children.

2.
Intensive Care Med Exp ; 12(1): 21, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38424411

RESUMEN

BACKGROUND: Obtaining a properly fitting non-invasive ventilation (NIV) mask to treat acute respiratory failure is a major challenge, especially in young children and patients with craniofacial abnormalities. Personalization of NIV masks holds promise to improve pediatric NIV efficiency. As current customization methods are relatively time consuming, this study aimed to test the air leak and surface pressure performance of personalized oronasal face masks using 3D printed soft materials. Personalized masks of three different biocompatible materials (silicone and photopolymer resin) were developed and tested on three head models of young children with abnormal facial features during preclinical bench simulation of pediatric NIV. Air leak percentages and facial surface pressures were measured and compared for each mask. RESULTS: Personalized NIV masks could be successfully produced in under 12 h in a semi-automated 3D production process. During NIV simulation, overall air leak performance and applied surface pressures were acceptable, with leak percentages under 30% and average surface pressure values mostly remaining under normal capillary pressure. There was a small advantage of the masks produced with soft photopolymer resin material. CONCLUSION: This first, proof-of-concept bench study simulating NIV in children with abnormal facial features, showed that it is possible to obtain biocompatible, personalized oronasal masks with acceptable air leak and facial surface pressure performance using a relatively short, and semi-automated production process. Further research into the clinical value and possibilities for application of personalized NIV masks in critically ill children is needed.

3.
Physiol Meas ; 44(1)2023 01 31.
Artículo en Inglés | MEDLINE | ID: mdl-36599175

RESUMEN

Objective.To examine the influence of the endotracheal tube (ETT) on respiratory reactance (Xrs) measured with the forced oscillation technique (FOT) and develop a correction method for it.Approach.In a bench study, the reactance of ETTs (Xtube) with different dimensions was measured on a breathing test lung in various respiratory settings.Main results.Xtubecan be accurately predicted by a fitted formula, with an R2of 0.97, with negligible effects due to changes in respiratory pattern and lung volume.Significance.The developed formula offers the ability to measure ETT-independent Xrsvalues of patients, improving the potential of FOT for lung function testing in mechanically ventilated newborns.