Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Med Imaging (Bellingham) ; 10(3): 035001, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37304527

RESUMEN

Purpose: Using optimal settings for x-ray scans is crucial for obtaining three-dimensional images of high quality while keeping the patient dose low. Our work compares dose and image quality (IQ) of three intraoperative imaging systems [O-arm cone-beam computed tomography (CBCT), ClarifEye C-arm CBCT, and Airo computed tomography] used for spinal surgery. Approach: Patients of 70, 90, and 110 kg were simulated with an anthropomorphic phantom by adding tissue-equivalent material. Titanium inserts were placed in the phantom spine for reproducing metal artifacts in the images. Organ dose was measured with thermo-luminescent dosimeters for effective dose (E) calculation. Subjective IQ was assessed by ranking the images acquired with the manufacturer-defined imaging protocols. Objective IQ was assessed with a customized Catphan phantom. Results: The ClarifEye protocols resulted in the lowest E ranging from 1.4 to 5.1 mSv according to phantom size and protocol. The highest E was measured for the high-definition protocol of O-arm (E 2.2 to 9 mSv) providing the best subjective IQ for imaging of the spine without titanium inserts. For the images with metal, the best IQ was obtained with ClarifEye. Airo (E 5.5 to 8.4 mSv) was ranked with the lowest IQ for images without metal while the rank improved for images with metal. Airo images had better uniformity, noise, and contrast sensitivity compared with CBCTs but worse high-contrast resolution. The values of these parameters were comparable between the CBCT systems. Conclusions: Both CBCT systems provided better IQ compared with Airo for navigation of lumbar spinal surgery for the original phantom. Metal artifacts particularly affect O-arm images decreasing the subjective IQ. The high spatial resolution of CBCT systems resulted in a relevant parameter for the visibility of anatomical features important for spine navigation. Low dose protocols were enough to obtain a clinically acceptable contrast-to-noise ratio in the bones.

2.
Phys Med ; 81: 9-19, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33310424

RESUMEN

PURPOSE: To compare the effective dose (ED) and image quality (IQ) of O-arm cone-beam CT (Medtronic, Minneapolis, MN, USA) and Airo multi-slice CT (Brainlab AG, Munich, Germany) for intraoperative-CT (i-CT) in spinal surgery. METHODS: The manufacturer-defined protocols available in the O-arm and Airo systems for three-dimensional lumbar spine imaging were compared. Organ dose was measured both with thermo-luminescent dosimeters and GafChromic films in the Alderson RadiationTherapy anthropomorphic phantom. A subjective analysis was performed by neurosurgeons to compare the clinical IQ of the anthropomorphic phantom images acquired with the different i-CT systems and imaging protocols. Image uniformity, noise, contrast-to-noise-ratio (CNR), and spatial resolution were additionally assessed with the Catphan 504 phantom. RESULTS: O-arm i-CT caused 56% larger ED than Airo due to the high definition (HD) imaging protocol. The noise was larger for O-arm images leading to a lower CNR than that measured for Airo. Moreover, scattering and beam hardening effects were observed in the O-arm images. Better spatial resolution was measured for the O-arm system (9 lp/cm) than for Airo (4 lp/cm). For all the investigated protocols, O-arm was found to be better for identifying anatomical features important for accurate pedicle screw positioning. CONCLUSIONS: According to phantom measurements, the HD protocol of O-arm offered better clinical IQ than Airo but larger ED. The larger noise of O-arm images did not compromise the clinical IQ while the superior spatial resolution of this system allowed a better visibility of anatomical features important for pedicle screw positioning in the lumbar region.


Asunto(s)
Imagenología Tridimensional , Cirugía Asistida por Computador , Tomografía Computarizada de Haz Cónico , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X
3.
Strahlenther Onkol ; 196(10): 943-951, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32875372

RESUMEN

PURPOSE: The purpose of the reported study was to investigate the value of cone-beam computed tomography (CBCT)-based radiomics for risk stratification and prediction of biochemical relapse in prostate cancer. METHODS: The study population consisted of 31 prostate cancer patients. Radiomics features were extracted from weekly CBCT scans performed for verifying treatment position. From the data, logistic-regression models were learned for establishing tumor stage, Gleason score, level of prostate-specific antigen, and risk stratification, and for predicting biochemical recurrence. Performance of the learned models was assessed using the area under the receiver operating characteristic curve (AUC-ROC) or the area under the precision-recall curve (AUC-PRC). RESULTS: Results suggest that the histogram-based Energy and Kurtosis features and the shape-based feature representing the standard deviation of the maximum diameter of the prostate gland during treatment are predictive of biochemical relapse and indicative of patients at high risk. CONCLUSION: Our results suggest the usefulness of CBCT-based radiomics for treatment definition in prostate cancer.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Biología Computacional , Tomografía Computarizada de Haz Cónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Aprendizaje Automático , Neoplasias de la Próstata/diagnóstico por imagen , Radioterapia de Intensidad Modulada , Adenocarcinoma/sangre , Adenocarcinoma/patología , Adenocarcinoma/radioterapia , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estadificación de Neoplasias , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/radioterapia , Curva ROC , Planificación de la Radioterapia Asistida por Computador
4.
Br J Radiol ; 93(1115): 20200412, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-32822249

RESUMEN

OBJECTIVE: To evaluate the performance of low dose cone beam CT (CBCT) acquisition protocols for image-guided radiotherapy of prostate cancer. METHODS: CBCT images of patients undergoing prostate cancer radiotherapy were acquired with the settings currently used in our department and two low dose settings at 50% and 63% lower exposure. Four experienced radiation oncologists and two radiation therapy technologists graded the images on five image quality characteristics. The scores were analysed through Visual Grading Regression, using the acquisition settings and the patient size as covariates. RESULTS: The low dose acquisition settings have no impact on the image quality for patients with body profile length at hip level below 100 cm. CONCLUSIONS: A reduction of about 60% of the dose is feasible for patients with size below 100 cm. The visibility of low contrast features can be compromised if using the low dose acquisition settings for patients with hip size above 100 cm. ADVANCES IN KNOWLEDGE: Low dose CBCT acquisition protocols for the pelvis, based on subjective evaluation of patient images.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Aceleradores de Partículas , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Estudios de Factibilidad , Humanos , Masculino , Pelvis/diagnóstico por imagen , Dosis de Radiación , Radioterapia Guiada por Imagen/instrumentación , Radioterapia de Intensidad Modulada/instrumentación , Análisis de Regresión
5.
EJNMMI Phys ; 4(1): 11, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28211032

RESUMEN

BACKGROUND: Monolithic scintillators read out by arrays of photodetectors represent a promising solution to obtain high spatial resolution and the depth of interaction (DOI) of the annihilation photon. We have recently investigated a detector geometry composed of a monolithic scintillator readout on two sides by silicon photomultiplier (SiPM) arrays, and we have proposed two parameters for the DOI determination: the difference in the number of triggered SiPMs on the two sides of the detector and the difference in the maximum collected signal on a single SiPM on each side. This work is focused on the DOI calibration and on the determination of the capability of our detector. For the DOI calibration, we studied a method which can be implemented also in detectors mounted in a full PET scanner. We used a PET detector module composed of a monolithic 20 × 20 × 10 mm3 LYSO scintillator crystal coupled on two opposite faces to two arrays of SiPMs. On each side, the scintillator was coupled to 6 × 6 SiPMs. In this paper, the two parameters previously proposed for the DOI determination were calibrated with two different methods. The first used a lateral scan of the detector with a collimated 511 keV pencil beam at steps of 0.5 mm to study the detector DOI capability, while the second used the background radiation of the 176Lu in the scintillator. The DOI determination capability was tested on different regions of the detector using each parameter and the combination of the two. RESULTS: With both parameters for the DOI determination, in the lateral scan, the bias between the mean reconstructed DOI and the real beam position was lower than 0.3 mm, and the DOI distribution had a standard deviation of about 1.5 mm. When using the calibration with the radioactivity of the LYSO, the mean bias increased of about 0.2 mm but with no degradation of the standard deviation of the DOI distribution. CONCLUSIONS: The two parameters allow to achieve a DOI resolution comparable with the state of the art, giving a continuous information about the three-dimensional interaction position of the scintillation. These results were obtained by using simple estimators and a detector scalable to a whole PET system. The DOI calibration obtained using lutetium natural radioactivity gives results comparable to the other standard method but appears more readily applicable to detectors mounted in a full PET scanner.

6.
J Med Imaging (Bellingham) ; 4(1): 011005, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27981069

RESUMEN

The quality assurance of particle therapy treatment is a fundamental issue that can be addressed by developing reliable monitoring techniques and indicators of the treatment plan correctness. Among the available imaging techniques, positron emission tomography (PET) has long been investigated and then clinically applied to proton and carbon beams. In 2013, the Innovative Solutions for Dosimetry in Hadrontherapy (INSIDE) collaboration proposed an innovative bimodal imaging concept that combines an in-beam PET scanner with a tracking system for charged particle imaging. This paper presents the general architecture of the INSIDE project but focuses on the in-beam PET scanner that has been designed to reconstruct the particles range with millimetric resolution within a fraction of the dose delivered in a treatment of head and neck tumors. The in-beam PET scanner has been recently installed at the Italian National Center of Oncologic Hadrontherapy (CNAO) in Pavia, Italy, and the commissioning phase has just started. The results of the first beam test with clinical proton beams on phantoms clearly show the capability of the in-beam PET to operate during the irradiation delivery and to reconstruct on-line the beam-induced activity map. The accuracy in the activity distal fall-off determination is millimetric for therapeutic doses.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA