Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Implant Dent Relat Res ; 26(2): 289-298, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37675656

RESUMEN

INTRODUCTION: This in vitro study aims to biomechanically evaluate the influence of medium contamination for example, saliva, blood, chlorhexidine (liquid and gel), and fluoride mouthwash on the biomechanical behavior of implant abutments' screws under static and dynamic loading. METHODS: Forty five Ti6Al4V commercial dental implants and abutments were tested in this study. Two main mechanical tests were carried out in the selected media. The first, static, aimed to evaluate the torque loss after the first tightening. The second, dynamic, involved a random cyclic load range between 0 and 200 N to evaluate torque loss due to mastication. In addition, metallographic longitudinal and cross-sections of the abutment-implant apparatus were examined to evaluate the abutment screw-abutment-implant interface. RESULTS: The static torque test showed that irrespective of the media, no statistical difference in static torque loss was found prior to dynamic loading. For the dynamic tests, torque-angle evolution analysis during tightening to 30 Ncm and after the spectrum loading, showed the same global mechanical behavior for all media, but the statistical analysis indicated a difference between the groups in reverse torque values (RTV) and in the torque loss due to dynamic loading. The medium groups CHX, CHX-gel, and Fluoride mouthwash, showed a meaningful torque loss due to loading, but the medium groups, control (no medium), blood and saliva showed an opposite trend and required a higher torque to open the abutment screws. The microstructural analysis revealed clear signs of cold-welding/galling, post-dynamic loading in these latter groups. CONCLUSIONS: The presence of lubrication/contamination media (CHX mouthwash/CHX-gel/Fluoride mouthwash) reduces the preload generated due to tightening but prevents damage due to galling. The observed reduction of RTV clearly emphasizes the need for frequent abutment screw retightening for implant-supported prosthetic long-term stability.


Asunto(s)
Implantes Dentales , Resiliencia Psicológica , Fluoruros , Antisépticos Bucales , Pilares Dentales , Análisis del Estrés Dental , Torque , Diseño de Implante Dental-Pilar
2.
Polymers (Basel) ; 15(2)2023 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-36679326

RESUMEN

This study compared the shear bond strength (SBS) and micromorphology of composite resin to human dentin after pre-treatment with silica-modified aluminum oxide air abrasion. Forty-six molar teeth were treated with either Scotchbond Multi-Purpose (SCMP) or Clearfil SE Bond (CLSE) adhesive. Buccal surfaces were pre-treated with the CoJet air abrasion system (SB), and lingual surfaces were controls. The adhesion of light-cured resin composite to the treated dentin surface was evaluated with SBS. After debonding, substrate surfaces were examined with an optical microscope for failure analysis. In addition, 15 molar teeth were sectioned and randomly assigned to one of five groups, according to the dentin surface pre-treatment and adhesive type, and examined with high-vacuum scanning electron microscopy/energy dispersive X-rays (SEM/EDS). The type of adhesive had a significant effect on SBS (p = 0.000); CLSE had the highest values. SB did not affect SBS (p = 0.090). SEM/EDS revealed residual aluminum and/or silicon on all dentin surfaces after SB, except for the control. Treatment with 32% phosphoric acid in the SCMP adhesive decreased the amounts of aluminum and silicon compared to SB dentin only, whereas CLSE resulted in similar quantities of aluminum and silicon as air-abraded dentin. The results of this study indicate that CLSE might have a higher bond strength to dentin than SCMP. Pre-treatment with SB does not appear to affect bonding strength.

3.
J Dent Educ ; 87(4): 533-539, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36374560

RESUMEN

OBJECTIVES: The current study aimed to assess criteria validity and test-retest reliability of the modified O'Connor Tweezer Dexterity (O'Connor) and the Purdue Pegboard test (PPT) for use among dental students. Occupational therapists were asked to assess dentist-related skills due to the high percentage of students who failed the dental school exams that year. The O'Connor and the PPT are suitable for these purposes, they aim to evaluate fine motor skills requirements. The original tests were modified for use under indirect visualization conditions (through a mirror) to mimic the typical dentists' work environment. MATERIALS AND METHODS: A total of 110 dentists were included in the present study (50 dentists for the O'Connor test and 60 for the PPT). Both tests were conducted twice. Initially, the original version of the tests was followed by the modified versions (through a mirror). For the test-retest reliability assessment, 21 participants (10 participants from the O'Connor group and 11 participants from the PPT group) repeated the evaluation within a 1-week interval using the same settings (original followed by modified versions). RESULTS: Both versions of the O'Connor tests were significantly correlated (r = 0.54, p < 0.01), as were the two PPT versions (r = 0.640, p < 0.01). Significantly test-retest reliability was found for both tests. The interclass correlation ranged between 0.883 and 0.997, p < 0.000. CONCLUSION: The results confirmed our hypothesis, demonstrating a criteria validity and test-retest reliability assessment of the modified O'Connor and the modified PPT for assessing dentists.


Asunto(s)
Destreza Motora , Estudiantes de Odontología , Humanos , Reproducibilidad de los Resultados , Mano , Pruebas Psicológicas
4.
Materials (Basel) ; 15(12)2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35744363

RESUMEN

Aims: To determine if restoration location and/or execution behavior force parameters have an influence on the mechanical properties of bulk-fill composite dental restorations. Methods: Pressure transducers were placed within each quadrant of dental mannequin jaws. Cylindrical molds were placed above the transducers and filled with two bulk-fill composite materials, Filtek and Tetric, by four experienced dentists. Each dentist prepared five specimens per quadrant and material. The total placement time, mean force, number of peak forces (above 25 N), and mean peak(s) force during placement were measured. Then, the stiffness and maximal compressive strength of the specimens were determined while loading the specimens up to failure using a universal loading machine. Results: Placement time was affected by jaw (p < 0.004) and side (p < 0.029), with the shortest time demonstrated for the left side of the mandible. Force exerted during restoration placement was not normally distributed without differences in location (jaw) or material. A higher application force was found on the right side (p < 0.01). The number of peak forces was affected by side (p < 0.03), with less peaks on the left side. No significant differences were found in compressive strength when correlated to restoration location, participant, or material (p = 0.431). The stiffness values of Filtek (3729 ± 228 N/mm) were found to be 15% higher than Tetric (3248 ± 227 N/mm) (p < 0.005). No correlations were found between the compressive strength or stiffness and the amount of force applied during placement. Conclusions: The individual restoration material placement parameters did influence practitioner performance; however, these differences did not affect the mechanical properties of the final restoration.

5.
Materials (Basel) ; 15(6)2022 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-35329555

RESUMEN

To compare the three-dimensional accuracy of an open-tray and two snap on impression techniques (with and without connecting the plastic caps of the snap on impression transfers) in a full arch 6-implant model, a reference acrylic resin model of the maxilla with six implants was fabricated. Prominent geometrical triangles, in the palate area, served as reference points for a digital overlap between scans. Three impression transfer techniques were evaluated and compared: open-tray direct impression (DI), snap on impression (SpO), and connected snap on impression (SpOC). Polyether impression material was used to make 30 impressions (n = 10), and the master model and all casts were digitally scanned with a laboratory optical scanner. The obtained 3D data were converted and recorded as STL files, which were imported to a 3D inspection software program. Angular deviations (buccal, occlusal and interproximal planes) between the study casts and the reference model were measured. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey post hoc test, with 0.05 used as the level of significance. The 3D angular deviations from the master model revealed no significant differences between the DI and SpO impression groups, but there were significant differences in the SpOC impression group, particularly in the buccal and occlusal planes. In all groups, the 3D angular deviation between the most distal scan abutments on each side of the model was significantly different from all other areas when compared to the master model. Within the limits of this study, it is possible to conclude that the indirect closed tray snap on impression technique with unconnected plastic caps exhibited the same three-dimensional accuracies as the direct open tray technique. The indirect closed tray snap on impression technique with connected plastic caps was less accurate than either the indirect closed tray snap on impression technique with unconnected plastic caps or the direct open tray technique. In the case of full arch implant supported prostheses, inaccuracies may be expected in the most distal implants for all the three impression techniques evaluated in this study. Further in vitro and in vivo research is required.

6.
Materials (Basel) ; 15(3)2022 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-35160777

RESUMEN

The aim of this study was to assess retrospectively the survival and success rates of monolithic zirconia restorations supported by teeth and implants in bruxer versus non-bruxer patients. Methods: A total of 15 bruxer and 25 non-bruxer patients attended the recall appointment. The bruxer group (mean age of 61.2 ± 13.3 years and follow-up of 58.7 ± 16.8 months) were treated with 331 monolithic zirconia restorations, while the non-bruxer group, with a comparable mean age and follow-up time, were treated with 306 monolithic zirconia restorations. Clinical data were retrieved from the patients' files. At the recall appointment, all supporting teeth and implants were examined for biological and technical complications, and the restorations were evaluated using modified California Dental Association (CDA) criteria. Data were statistically analyzed using survival analysis methods. A significance level of p < 0.05 was used. A total of 31 versus 27 biologic and technical complications were recorded in the bruxer and non-bruxer groups, respectively. No significant differences were found between the two groups regarding overall complications and survival rate. Regarding the type of complication, a significantly higher rate of veneered porcelain chipping (p = 0.045) was observed in the bruxer group. With regard to biological complications, the only complications that exhibited a borderline, although not significant, difference were three fractured teeth exclusively in the bruxer group (p = 0.051), which were replaced with implant-supported restorations. Within the limitations of this study, we conclude that there were no significant differences in the overall survival and success rates of the monolithic zirconia restorations in bruxer versus non-bruxer patients, although veneered zirconia restorations and single tooth abutments exhibited a higher rate of complications in the bruxer group.

7.
Materials (Basel) ; 14(12)2021 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-34203752

RESUMEN

The aim of the current study was to evaluate the influence of hydrofluoric (HF) acid concentration and conditioning time on the shear bond strength (SBS) of dual cure resin cement to pressed lithium disilicate ceramic compared to treatment with an Etch and Prime self-etching glass-ceramic primer (EP). A total of 100 samples of pressed lithium disilicate (IPS e.max Press, Ivoclar Vivadent) were randomly divided into five groups (n = 20) according to surface treatment: two different concentrations of HF (5% or 9%), for different durations (20 or 90 s), or treatment with EP. Adhesion of light-cured resin cement to the treated surface was tested by the SBS test. The substrate surfaces of the specimen after failures were examined by SEM. Data were analyzed using Weibull distribution. The highest cumulative failure probability of 63.2% of the shear bond strength (η parameter) values was in the 9% HF -90 s group (17.71 MPa), while the lowest values were observed in the 5% HF -20 s group (7.94 MPa). SBS values were not affected significantly by the conditioning time (20 s or 90 s). However, compared to treatment with 5% HF, surface treatment with 9% HF showed a significantly higher η (MPa) as well as ß (reliability parameter). Moreover, while compared to 9% HF for 20 s, EP treatment did not differ significantly in SBS values. Examination of the failure mode revealed a mixed mode of failure in all the groups. Within the limits of this study, it is possible to assume that IPS e.max Press surface treatment with 9% HF acid for only 20 s will provide a better bonding strength with resin cement than using 5% HF acid.

8.
Anat Sci Educ ; 14(5): 629-640, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32866344

RESUMEN

Although three-dimensional (3D) printing technology is increasingly used in dental education, its application regarding the provision of online visual augmented feedback has not been tested. Thus, this study aimed to: (1) develop two generations of multicolored 3D-printed teeth that provide visual augmented feedback for students conducting the cavity preparation process, (2) assess students' clinical performance after training on the 3D models, and (3) acquire student feedback. For the first-generation model, augmented feedback was obtained from five 3D-printed teeth models for five cavity preparation procedures. Each model comprised three layers printed in green, yellow, and red indicating whether preparation was acceptable, limited, or unacceptable, respectively. The study used a crossover design in which the experimental group trained on five multicolored models and 10 standard plastic teeth, and the control group trained on 15 standard plastic teeth. Students gave positive feedback of the methodology but complained about the printed material's hardness. Therefore, a second-generation model was developed: the model's occlusal plane was replaced with a harder printed acrylic material, and the experiment was repeated. During training, instructors provided external terminal feedback only for performance on standard plastic teeth. Manual grades for cavity preparations on standard plastic teeth were compared. No significant differences were found between the control and experimental groups in both generations' models. However, less instructor time was needed, and similar clinical results were obtained after training with both generations. Thus, multicolored 3D-printed teeth models promote self-learning during the process of acquiring manual skills and reduce student dependency on instructors.


Asunto(s)
Anatomía , Estudiantes de Odontología , Anatomía/educación , Estudios Cruzados , Educación en Odontología , Retroalimentación Sensorial , Humanos , Impresión Tridimensional
9.
Materials (Basel) ; 13(18)2020 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-32917039

RESUMEN

The aim of this study was to evaluate the retentive strength of zirconium oxide (yttria-stabilized tetragonal zirconia polycrystals (Y-TZP)) crown-copings treated by combined mechanical and chemical treatments and cemented by four types of self-adhesive resin cements (SARCs) to human prepared teeth, before and after six months of aging in water and thermocycling. A total of 120 molar teeth were mounted, prepared using a standardized protocol and digitally scanned, and Y-TZP copings were produced. Teeth were randomly assigned to four SARC groups. Prior to cementation, the intaglio surfaces of all crowns were sandblasted and then coated with Z-Prime™ Plus (Bisco Dental, Schaumburg, IL, USA). Post cementation, each cement group was subdivided into aged and non-aged groups. After aging, the cemented assemblies were tested for retentive strength using a universal testing machine. Failure analysis was conducted by inspecting all matched debonded surfaces of the teeth and crowns at 3× magnification. Aging treatment did not affect the retentive strength of the Y-TZP crown-copings (p = 0.918). The interaction between cement and aging was statistically significant (p = 0.024). No significant differences in the retentive strengths between the different SARCs were observed pre-aging (p = 0.776), whereas post-aging, Panavia SA (PAN; Kuraray Dental Co Ltd., Osaka, Japan) showed significantly higher strength than RelyX U-200 (RU200; 3M ESPE, Seefeld, Germany). The predominant failure mode was adhesive between the cement and dentin, followed by mixed mode failure.

10.
Materials (Basel) ; 12(19)2019 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-31547045

RESUMEN

The static and dynamic load-bearing capacities and failure modes of zirconia crowns screwed to multi-unit abutments (MUAs) with and without a titanium base (T-base) were determined. Thirty-six monolithic zirconia crowns screwed to straight MUAs torqued to laboratory analogs (30 Ncm) were assigned to two groups (n = 18). In group A, the zirconia crowns were screwed directly to the MUAs; in group B, the zirconia crowns were cemented to the T-base and screwed to the MUAs. All specimens were aged in 100% humidity (37 °C) for one month and subjected to thermocycling (20,000 cycles). Afterwards, the specimens underwent static and dynamic loading tests following ISO 14801. The failure modes were evaluated by stereomicroscopy (20×). There was an unequivocally similar trend in the S-N plots of both specimen groups. The load at which the specimens survived 5,000,000 cycles was 250 N for both groups. Group A failed mainly within the metal, and zirconia failure occurred only at a high loading force. Group B exhibited failure within the metal mostly in conjunction with adhesive failure between the zirconia and T-base. Zirconia restoration screwed directly to an MUA is a viable option, but further studies with larger sample sizes are warranted.

11.
ACS Appl Mater Interfaces ; 11(24): 21334-21342, 2019 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-31134790

RESUMEN

The rapid advancement of peptide- and amino-acid-based nanotechnology offers new approaches for the development of biomedical materials. The utilization of fluorenylmethyloxycarbonyl (Fmoc)-decorated self-assembling building blocks for antibacterial and anti-inflammatory purposes represents promising advancements in this field. Here, we present the antibacterial capabilities of the nanoassemblies formed by Fmoc-pentafluoro-l-phenylalanine-OH, their substantial effect on bacterial morphology, as well as new methods developed for the functional incorporation of these nanoassemblies within resin-based composites. These amalgamated materials inhibit and hinder bacterial growth and viability and are not cytotoxic toward mammalian cell lines. Importantly, due to the low dosage required to confer antibacterial activity, the integration of the nanoassemblies does not affect their mechanical and optical properties. This approach expands on the growing number of accounts on the intrinsic antibacterial capabilities of self-assembling building blocks and serves as a basis for further design and development of enhanced composite materials for biomedical applications.


Asunto(s)
Antibacterianos/química , Materiales Biocompatibles/química , Nanoestructuras/química , Nanotecnología/métodos , Antibacterianos/farmacología , Materiales Biocompatibles/farmacología , Resinas Compuestas/química , Materiales Dentales/química , Materiales Dentales/farmacología
12.
PLoS One ; 14(2): e0211639, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30707724

RESUMEN

OBJECTIVES: Traditionally, the acquisition of manual skills in most dental schools worldwide is based on exercises on plastic teeth placed in a "phantom head simulator". No manual trainings are done at home. Studies revealed that preliminary training of one motoric task leads to significant improvement in performance of the required motoric task that has similar components. Performing tasks indirectly via a dental mirror are complicated for the young dental students. We hypothesized that instructed training of basic skills required in dentistry at home on a tool simulating the phantom laboratory will improve the capabilities of the students and will be reflected by their clinical grades. METHODS: We developed a portable tool PhantHome which is composed of jaws, gingival tissue, rubber cover and a compatible stand. Specific teeth produced by a 3D printer with drills in different directions were placed in both jaws. Students were requested to insert pins by using tweezers and dental mirror according to instructions initiating with easy tasks and continue to ones that are more complicated. 106 first clinical year dental students participated in the study; 65 trained only in the traditional phantom lab (control). 41 trained at home by the PhantHome tool two weeks before and 2 months during the initial stage of phantom lab. The students grades routinely provided in the phantom laboratory at different stages were compared. RESULTS: Students who trained with the portable tool performed better than the control group in the first direct and second indirect preparations (p<0.05). These exams were taken when the PhantHome was available to the students. Then, the tool was returned and the phantom course continued regularly. We believe that this is why no differences between the grades of the groups were observed further on. CONCLUSIONS: Training by the PhantHome improves motor skills and consequently the clinical performances.


Asunto(s)
Educación en Odontología/métodos , Adulto , Competencia Clínica , Instrumentos Dentales , Odontología/métodos , Evaluación Educacional , Femenino , Humanos , Aprendizaje , Masculino , Destreza Motora/fisiología , Manipulaciones Musculoesqueléticas/métodos , Estudiantes de Odontología , Adulto Joven
13.
Int J Mol Sci ; 19(12)2018 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-30562955

RESUMEN

The retention of laser-sintered cobalt-chromium (Co-Cr)-based crowns were examined after dentin pretreatment with desensitizing paste containing 8% arginine and calcium carbonate (DP-ACC). Forty lower first molars were prepared using a standardized protocol. The Co-Cr crowns were produced using selective laser melting. The teeth were either pretreated with the desensitizing paste or not pretreated. After one week, each group was cemented with glass ionomer cement (GIC) or zinc phosphate cement (ZPC). Surface areas of the teeth were measured before cementation. After aging, a universal testing machine was used to test the retentive strength of the cemented crown-tooth assemblies. The debonded surfaces of the teeth and crowns were examined at 2.7× magnification. Pretreating the dentin surfaces with the desensitizing paste before cementation with GIC or ZPC did not affect the retention of the Co-Cr crowns. The retention of the GIC group (6.04 ± 1.10 MPa) was significantly higher than that of the ZPC group (2.75 ± 1.25 MPa). The predominant failure mode for the ZPC and the nontreated GIC group was adhesive cement-dentin failure; for the treated GIC group, it was adhesive cement-crown failure. The desensitizing paste can be safely used to reduce post-cementation sensitivity without reducing the retentive strength of Co-Cr crowns cemented with GIC or ZPC.


Asunto(s)
Arginina/química , Carbonato de Calcio/química , Aleaciones de Cromo/química , Coronas , Dentina/química , Rayos Láser , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pomadas , Propiedades de Superficie
14.
Eur J Oral Sci ; 126(6): 518-525, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30252188

RESUMEN

The circumferential strains created in the radicular dentin by nickel-titanium (NiTi) and stainless steel (SS) finger spreaders (FSs) during a simulated clinical procedure of lateral compaction were compared after minimal (size 50) and extensive (size 100) canal preparations. Nineteen maxillary central incisors underwent minimal preparation, while 10 underwent an extra phase of extensive preparation. Four miniature strain gauges were bonded circumferentially in the apical third of the root (buccal, lingual, mesial, and distal). Lateral compaction was performed using either NiTi-FSs or SS-FSs. Force and strains were continuously recorded. The maximal strains (with and without normalization according to force) were recorded. The SS-FSs generated higher maximal strains normalized according to force compared with the NiTi-FSs. The maximal normalized strains were higher by 37%-43% for the mesial and distal aspects and by 6%-14% for the buccal and lingual aspects after the minimal preparation and by 24%-28% for the mesial and distal aspects and by 19%-20% for the buccal and lingual aspects after extensive preparation. The maximal normalized strains increased by 30%-70% from minimal to extensive preparations, with two teeth exhibiting vertical root fracture while compaction with SS-FS. The NiTi-FSs induce less strain in root dentin than the SS-FSs and thus may contribute less to the risk of vertical root fracture.


Asunto(s)
Aleaciones Dentales/química , Incisivo/química , Níquel/química , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular/métodos , Acero Inoxidable/química , Estrés Mecánico , Titanio/química , Raíz del Diente/química , Adulto , Cavidad Pulpar , Análisis del Estrés Dental , Diseño de Equipo , Humanos , Ensayo de Materiales , Persona de Mediana Edad , Materiales de Obturación del Conducto Radicular/química , Obturación del Conducto Radicular/instrumentación , Propiedades de Superficie , Fracturas de los Dientes
15.
Sleep ; 41(9)2018 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-30215814

RESUMEN

Following initial acquisition, studies across domains have shown that memories stabilize through consolidation processes, requiring a post-acquisition temporal interval to allow their occurrence. In procedural skill memories, consolidation not only stabilizes the memory, but also simultaneously enhances it by accumulating additional gains in performance. In addition, explicit skill tasks were previously shown to consolidate through sleep, whereas implicit tasks were consolidated following a time interval which did not include a period of sleep. Although previous research has been instrumental in utilizing simple motor tasks designed to model skill learning, whether and how skill consolidation processes operate in complex real-life environments remains to be determined. Here, we tested consolidation in a complex motor skill, used to train execution of fine-motor movements. Since the complex task was explicit, we hypothesized that consolidation will be evident immediately following sleep, as in simple explicit motor skills. However, results show that even though participants were aware of the goal of the complex skill task, consolidation was evident only 24 hr following skill acquisition, and not following a shorter 12 hr interval, even when the latter included sleep. An additional experiment verified that without a temporal interval longer than 12hr, the same skill training does not undergo complete consolidation. These results suggest that task complexity is a crucial characteristic determining the proper terms allowing full consolidation. Due to the enhanced ecological validity of this study, revealing the differences between complex and simple motor skills could enable the facilitation of advanced rehabilitation methods following neurological injuries.


Asunto(s)
Aprendizaje/fisiología , Destreza Motora/fisiología , Sueño/fisiología , Vigilia/fisiología , Adolescente , Adulto , Concienciación/fisiología , Femenino , Humanos , Masculino , Memoria/fisiología , Factores de Tiempo , Adulto Joven
16.
PLoS One ; 13(3): e0193980, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29518127

RESUMEN

Dentists must be skilled when using dental mirrors. Working with mirrors requires spatial perception, bimanual coordination, perceptual learning and fine motor skills. Many studies have attempted to determine the predictors of manual skills among pre-clinical students, but consensus has yet to be reached. We hypothesized that valid and reliable occupational therapy test performance regarding indirect vision would differ between dental students and junior dentists and would explain the variance in manual skill performance in pre-clinical courses. To test this hypothesis, we applied the Purdue Pegboard test and O'Connor Tweezer Dexterity test under different conditions of direct and indirect vision. We administered these tests to students in phantom-head academic courses in 2015 and 2016 and to junior dentists. Students performed the tests at three time points: before phantom training (T0), at the end of the training (T1) and in the middle of the following year of study (T2). Dentists performed the same tests twice at 1st and 2nd trials one week apart. The results showed that indirect tasks were significantly more difficult to perform for both groups. These dexterity tests were sensitive enough to detect students' improvement after phantom training. The dentists' performances were significantly better than those of students at T0, specifically with regard to the use of tweezers under direct and indirect vision (the O'Connor test). A regression analysis showed that students' manual grades obtained at the beginning of the phantom course, their performance on the Purdue test using both hands, and their performance on the O'Connor test under indirect vision predicted phantom course success in 80% of cases. The O'Connor test under indirect vision is the most informative means of monitoring and predicting the manual skills required in the pre-clinical year of dentistry studies.


Asunto(s)
Pruebas de Aptitud , Destreza Motora , Pruebas Neuropsicológicas , Desempeño Psicomotor , Estudiantes de Odontología , Adulto , Evaluación Educacional , Femenino , Predicción , Lateralidad Funcional , Mano/fisiología , Humanos , Aprendizaje , Masculino , Modelos Anatómicos , Percepción Espacial , Adulto Joven
17.
Dent Mater ; 34(2): 306-316, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29183673

RESUMEN

OBJECTIVE: The aim of the study was to assess the roughness, structure and bond strength with zirconia of four grit-blasting treatments combined with three silane types, the reactivity of which was evaluated, as well. METHODS: The grit-blasted treatments performed on zirconia (Lava) were alumina (ALU), CoJet (COJ), SilJet (SLJ) and SilJet Plus (SJP, with silica-encapsulated silane). The other two silanes selected were the S-Bond (SB, prehydrolyzed) and Clearfil Ceramic Primer Plus (CP, prehydrolyzed with 10-MDP). The activity of the silanols in the silanes was evaluated by FTIR spectroscopy. Optical profilometry and Raman microspectroscopy were used for the assessment of roughness (Sa, Sz, Sdr parameters) and structure (monoclinic volume-Vm) of zirconia, before (REF) and after grit-blasting, and a shear bond strength (SBS) with a flowable resin composite, for the investigation of the bonding capacity of the treatments. RESULTS: Only SB demonstrated reactive silanols. CP and the SJP silanes were mostly in a polymerized siloxane state. Roughness was increased after grit-blasting as follows: ALU>SLJ,SJP>COJ>REF (Sa,Sz) and ALU>SLJ,COJ,SJP>REF (Sdr). ALU demonstrated the highest Vm (7.52%) from all other treatments (4.16-4.81%) and the REF (0%). COJ and SLJ showed the highest SBS (14-15.94MPa) regardless of the silane type used. SJP showed no significant differences from SLJ-SB and COJ-SB. Weibull analysis showed a reliability (ß) ranking of COJ, SJP, SLJ, ALU-CP>ALU-SB>REF and a characteristic life (η) ranking of COJ, SLJ, ≥SLJ-SB, SJP, ALU≥ALU-SB,REF-CP>REF-SB. SIGNIFICANCE: The reactivity of the silanes used showed great variations to support a predictable effect in all treatments. CP with deactivated silanols demonstrated a) the most reliable and strongest treatment with a silica-rich powder (COJ), despite the lowest Sa,Sz substrate values and b) high strength with a low-silica powder (SLJ) with higher Sa,Sz substrate values. Therefore, it may be concluded that 10-MDP greatly contributes to the bonding mechanism of the silane containing primers.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química , Silanos/química , Circonio/química , Óxido de Aluminio/química , Ensayo de Materiales , Metacrilatos , Dióxido de Silicio/química , Espectroscopía Infrarroja por Transformada de Fourier , Espectrometría Raman , Propiedades de Superficie
18.
Dent Mater ; 33(3): 344-357, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28174008

RESUMEN

OBJECTIVE: To evaluate the degree of conversion (DC%), salt yield and mechanical properties of self-adhesive luting agents (SAA) set under dual-cure (E) and self-cure (NE) modes. METHODS: Three SAA (GC LinkAce/GCLA, MaxCem Elite/MXEL, Rely-X Unicem 2/RXUN) and an adhesive resin luting agent (Rely-X Ultimate/RXUL-control) were used. The properties tested under E and NE modes were a) DC% and phosphate salt yield after 10min, 1h (h) and 3 weeks (w) storage, by infrared spectroscopy; and b) the mechanical properties of 3w-stored specimens by instrumented indentation testing (Martens hardness/HM, Elastic modulus/EIT, Elastic index/ηIT) and microscopic Vickers hardness/VH. Statistical analysis was performed by 3-way ANOVA (DC%), 2-way ANOVA (salt yield) and 1-way ANOVA (mechanical properties) at an a=0.05. RESULTS: Significantly higher DC% was found in E, except from the 3w groups of GCLA and MXEL. Within E, no significant differences were found, but within NE, there were differences in the 3 w groups of GCLA (vs 10 min) and MXEL (vs 1h). All materials demonstrated increased salt yield in NE, with the highest values found in RXUL and RXUN. GCLA, RXUL showed the lowest HM in E and MXEL the highest in NE. The rankings of the significant differences in EIT were MXEL>GCLA,RXUN,RXUL (E) and RXUL,MXEL>GCLA,RXUN (NE), whereas for ηIT RXUL,RXUN>GCLA,MXEL (E) and GCLA>RXUL>MXEL,RXUN (NE). The results of VH measurements showed an overestimation ranging from 13% up to 38% in comparison with HM. SIGNIFICANCE: There are significant differences in the properties tested, which may anticipate variations in the chemical, mechanical and biological performance of the products.


Asunto(s)
Cementos Dentales , Cementos de Resina , Dureza , Ensayo de Materiales , Estrés Mecánico
19.
J Mech Behav Biomed Mater ; 69: 267-274, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28113131

RESUMEN

Vertical root fracture (VRF) of endodontically treated teeth is relatively common, and the involved teeth have a poor prognosis. Previous destructive methodologies applied force to the root in an uneven manner; thus, the associated experiments could not truly assess the mechanical behavior of VRF. This problem was resolved in the current study via the novel application of a bursting pressure methodology to endodontically treated maxillary central incisors and premolars. Hydrostatic pressure was applied inside the root canal through a cannula bonded to the coronal access cavity, and the apical foramen was sealed. VRFs were observed as water burst from the fractured root surface. Morphometric parameters were measured by staining and serially sectioning the roots. The bursting pressure was significantly lower in the premolars compared with that in the incisors (19.1±3.3MPa and 25.5. ±4.5MPa, respectively, p=0.001). Cracks in the roots appeared from the apex to the cement enamel junction (CEJ) (61%), apex to mid-root (26%) and mid-root to CEJ (13%), and they involved either two root surfaces (52%) or one root surface (48%) and closely resembled clinical VRF cases. Positive correlations were found between the bursting pressure and the proximal root wall thickness, whereas correlations were not observed between the bursting pressure and the buccal or lingual wall thicknesses. Statistical Analyses of Covariance (ANCOVA) models showed that the proximal wall thickness and an elliptically shaped root cross section were the variables that indicated the differences in strength between premolars, which are more prone to VRF, and maxillary central incisors, which are less prone to VRF.


Asunto(s)
Fracturas de los Dientes/patología , Raíz del Diente/patología , Diente no Vital/patología , Diente Premolar , Humanos , Incisivo , Tratamiento del Conducto Radicular
20.
Clin Oral Investig ; 21(4): 1079-1086, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27262457

RESUMEN

OBJECTIVE: The aim of the current study was to examine the shear punch strength (SPS) of high-strength glass ionomer cements (HSGICs) in relation to coating applications and duration of coating. MATERIALS AND METHODS: I-Ninety specimens each of Fuji IX GP Fast (FIX Fast), Ionofil Molar AC (IM), Riva Self Cure (R) and Ketac Molar (KM) were prepared and divided into uncoated and coated groups, sub-divided into three sub-groups and incubated for 24 h, 1 week or 8 weeks (distilled water, 37 °C) before SPS. II-Ninety specimens each of uncoated and coated Fuji IX GP Extra were similarly prepared, divided into six sub-groups and incubated for 2 h, 24 h, 1 week, 1 month, 2 months or 3 months (artificial saliva, 37 °C) before SPS. Another 90 specimens were coated for 2 h, 24 h, 1 week, 1 month or 2 months, after which the coating was removed. Specimens were re-incubated in artificial saliva until the end of the 3-month period and then subjected to SPS. RESULTS: None of the materials gained extra strength when coated. Uncoated KM, IM (at all times) and FIX Fast (at 24 h) were stronger. Fuji IX GP Extra achieved 11.5 MPa after 2 h, which increased to 56.7 MPa after 24 h. The highest strength after 3 months was achieved when the coating was retained for 2 h (71.7 MPa). CONCLUSION: A resin coating will not positively affect the SPS of HSGICs. CLINICAL RELEVANCE: There is no need to protect HSGICs from water to gain extra strength unless the coating is retained for 2 h.


Asunto(s)
Cementos de Ionómero Vítreo/química , Resinas Sintéticas/química , Materiales Biocompatibles Revestidos , Análisis del Estrés Dental , Ensayo de Materiales , Saliva Artificial , Resistencia al Corte , Propiedades de Superficie , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...