Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Endoscopy ; 55(7): 591-598, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36882089

RESUMEN

BACKGROUND: Removing lumen-apposing metal stents (LAMSs) may be difficult and even harmful, but these features have seldom been analyzed. We aimed to generate a comprehensive assessment of the feasibility and safety of LAMS retrieval procedures. METHODS: A prospective multicenter case series including all technically successfully deployed LAMSs between January 2019 and January 2020 that underwent endoscopic stent removal. All retrieval-related data were prospectively recorded using standardized telephone questionnaires as part of centralized follow-up that ended after stent removal had been performed. Multivariable logistic regression models assessed the potential risk factors for complex removal. RESULTS: For the 407 LAMSs included, removal was attempted in 158 (38.8 %) after an indwell time of 46.5 days (interquartile range [IQR] 31-70). The median (IQR) removal time was 2 (1-4) minutes. Removal was labelled as complex in 13 procedures (8.2 %), although advanced endoscopic maneuvers were required in only two (1.3 %). Complex removal risk factors were stent embedment (relative risk [RR] 5.84, 95 %CI 2.14-15.89; P = 0.001), over-the-wire deployment (RR 4.66, 95 %CI 1.60-13.56; P = 0.01), and longer indwell times (RR 1.14, 95 %CI 1.03-1.27; P = 0.01). Partial and complete embedment were observed in 14 (8.9 %) and five cases (3.2 %), respectively. The embedment rate during the first 6 weeks was 3.1 % (2/65), reaching 15.9 % (10/63) during the following 6 weeks (P = 0.02). The adverse event rate was 5.1 %, including seven gastrointestinal bleeds (5 mild, 2 moderate). CONCLUSIONS: LAMS removal is a safe procedure, mostly requiring basic endoscopic techniques attainable in conventional endoscopy rooms. Referral to advanced endoscopy units should be considered for stents with known embedment or long indwell times, which may require more technically demanding procedures.


Asunto(s)
Endoscopía Gastrointestinal , Stents , Humanos , Estudios Retrospectivos , Stents/efectos adversos , Endoscopía Gastrointestinal/efectos adversos , Factores de Riesgo , Drenaje/efectos adversos , Endosonografía
3.
Rev Esp Enferm Dig ; 113(4): 292-293, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33267599

RESUMEN

We present the case of a 61-year-old male with a long-term epigastric mass and pain, high CA 19.9 levels and no weight loss. A computerized tomography was performed and a solid-cystic pancreatic mass was observed. The lesion measured 10 x 8 cm with well-defined margins, a macroscopic calcification and an enhanced solid component.


Asunto(s)
Quiste Broncogénico , Cistoadenoma Mucinoso , Neoplasias Pancreáticas , Quiste Broncogénico/diagnóstico por imagen , Quiste Broncogénico/cirugía , Cistoadenoma Mucinoso/diagnóstico por imagen , Cistoadenoma Mucinoso/cirugía , Humanos , Masculino , Persona de Mediana Edad , Páncreas , Neoplasias Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...