1.
Food Chem ; 262: 168-177, 2018 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-29751905

RESUMEN

A novel and reliable method to quantify residual levels of N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine in dairy products using ion-pairing reversed-phase liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and fully validated. Sample extraction was done with salting-out technique using acetonitrile and sodium chloride. For LC-MS/MS, the analyte was detected using positive electrospray ionization (ESI+) and two multiple reaction monitoring (MRM) transitions were monitored. The method was validated in the 5-150 µg kg-1 range using total error approach. Thus, performance criteria of the method were evaluated. Relative standard deviations for trueness and precision were lower than 10%; with the exception of hard pressed cheese at 5 µg kg-1 for precision. The limit of quantification (LOQ) was around 5-7 µg kg-1 depending on the matrix of interest. The method was successfully applied to accurately quantify N-(3-aminopropyl)-N-dodecylpropane-1,3-diamine in 146 various dairy products with a maximum contamination level of 225 µg kg-1 in cheese.


Asunto(s)
Cromatografía de Fase Inversa/métodos , Productos Lácteos/análisis , Propilaminas/análisis , Espectrometría de Masas en Tándem/métodos , Queso/análisis , Desinfectantes/análisis , Límite de Detección , Propilaminas/aislamiento & purificación
2.
J Chromatogr A ; 1517: 86-96, 2017 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-28851528

RESUMEN

Quaternary ammonium compounds (QACs) are both cationic surfactants and biocidal substances widely used as disinfectants in the food industry. A sensitive and reliable method for the analysis of benzalkonium chlorides (BACs) and dialkyldimethylammonium chlorides (DDACs) has been developed that enables the simultaneous quantitative determination of ten quaternary ammonium residues in dairy products below the provisional maximum residue level (MRL), set at 0.1mgkg-1. To the best of our knowledge, this method could be the one applicable to milk and to three major processed milk products selected, namely processed or hard pressed cheeses, and whole milk powder. The method comprises solvent extraction using a mixture of acetonitrile and ethyl acetate, without any further clean-up. Analyses were performed by liquid chromatography coupled with electrospray tandem mass spectrometry detection (LC-ESI-MS/MS) operating in positive mode. A C18 analytical column was used for chromatographic separation, with a mobile phase composed of acetonitrile and water both containing 0.3% formic acid; and methanol in the gradient mode. Five deuterated internal standards were added to obtain the most accurate quantification. Extraction recoveries were satisfactory and no matrix effects were observed. The method was validated using the total error approach in accordance with the NF V03-110 standard in order to characterize the trueness, repeatability, intermediate precision and analytical limits within the range of 5-150µgkg-1 for all matrices. These performance criteria, calculated by e.noval® 3.0 software, were satisfactory and in full accordance with the proposed provisional MRL and with the recommendations in the European Union SANTE/11945/2015 regulatory guidelines. The limit of detection (LOD) was low (<1.9µgkg-1) and the limit of quantification (LOQ) ranged from 5µgkg-1 to 35µgkg-1 for all matrices depending on the analytes. The validation results proved that the method is suitable for quantifying quaternary ammoniums in foodstuffs from dairy industries at residue levels, and could be used for biocide residues monitoring plans and to measure the exposition consumer to biocides products.


Asunto(s)
Queso/análisis , Cromatografía Líquida de Alta Presión , Análisis de los Alimentos/métodos , Leche/química , Compuestos de Amonio Cuaternario/análisis , Espectrometría de Masas en Tándem , Acetonitrilos/química , Animales , Compuestos de Benzalconio/análisis , Límite de Detección
3.
J AOAC Int ; 98(3): 649-657, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26025009

RESUMEN

Aquaculture has been the fastest growing animal production industry for the past four decades, and almost half of the fish eaten in the world are now farmed fish. To prevent diseases in this more intensive aquaculture farming, use of therapeutic chemicals has become a basic choice. The monitoring of malachite green, a triphenylmethane dye and one of the oldest and widely used chemicals in fish production, has gained more interest since the mid 1990s when this substance was finally proven to be toxic enough to be prohibited in seafood products destined for human consumption. The enforcement of the European Union (EU) regulation of this banned substance along with some other triphenylmethane dye congeners and their metabolites in its domestic production and in seafood imports was undertaken through the National Residue Monitoring Plans implemented in nearly all of the 28 EU member states. The reliability of the overall European monitoring of this dye contamination in aquaculture products was assessed by using the results of proficiency testing (PT) studies provided by the EU Reference Laboratory (EU-RL) in charge of the network of the EU National Reference Laboratories (NRLs). The proficiency of each NRL providing analytical support services for regulating dye residues was carefully checked during three PT rounds. In the process, the analytical methods developed and validated for this purpose have gradually been improved and extended over the last two decades.


Asunto(s)
Acuicultura/legislación & jurisprudencia , Colorantes/análisis , Inocuidad de los Alimentos , Laboratorios/normas , Alimentos Marinos/análisis , Compuestos de Tritilo/análisis , Animales , Unión Europea , Humanos , Legislación Alimentaria , Reproducibilidad de los Resultados
4.
J Chromatogr A ; 1339: 128-36, 2014 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-24666935

RESUMEN

A rapid and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous confirmation of 13 sulfonamides in honey was developed and fully validated in accordance with the European Commission Decision No 2002/657/EC. The validation scheme was built in accordance with the target level of 50µgkg(-1) for all analytes. The sulfonamides investigated were as follows: sulfaguanidine (SGN), sulfanilamide (SNL), sulfadiazine (SDZ), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethizole (SMZ), sulfadimerazine (SDM), sulfamonomethoxine (SMNM), sulfamethoxypiridazine (SMP), sulfadoxine (SDX), sulfamethoxazole (SMX), sulfaquinoxaline (SQX) and sulfadimethoxine (SDT). Several extraction procedures were investigated during the development phase. Finally, the best results were obtained with a procedure using acidic hydrolysis and cation exchange purification. Chromatographic separation was achieved on a C18 analytical column. Matrix effects were also investigated. Data acquisition implemented for the confirmatory purpose was performed by monitoring 2 MRM transitions per analyte under the positive electrospray mode. Mean relative recoveries ranged from 85.8% to 110.2% and relative standard deviations lying between 2.6% and 19.8% in intra-laboratory reproducibility conditions. The decision limits (CCα) ranged from 1.8 to 15.5µgkg(-1). High resolution mass spectrometry was used to investigate the possible formation of sulfonamide metabolites in honey. The validation results proved that the method is suitable for the screening and confirmatory steps as implemented for the French monitoring residue plan for sulfonamides residue control in honeybees.


Asunto(s)
Abejas , Contaminantes Ambientales/análisis , Miel/análisis , Sulfonamidas/análisis , Animales , Apicultura , Cromatografía Liquida/métodos , Residuos de Medicamentos/análisis , Unión Europea , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/métodos
5.
J Chromatogr A ; 1218(37): 6292-301, 2011 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-21840010

RESUMEN

A rapid and reliable LC-MS/MS method for the simultaneous confirmation of twelve non steroidal anti-inflammatory drugs (NSAIDs) in bovine milk was developed and fully validated in accordance with the European Commission Decision 2002/657/EC. The validation scheme was built in accordance with the MRLs or target analytical levels (EU-CRL recommended concentrations and detection capabilities) of the analytes, except for diclofenac for which the lower level of validation achieved was 0.5 µg kg(-1) whereas its MRL is 0.1 µg kg(-1). The NSAIDs investigated were as follows: phenylbutazone (PBZ), oxyphenylbutazone (OPB), naproxen (NP), mefenamic acid (MF), vedaprofen (VDP), flunixin (FLU), 5-hydroxyflunixin (FLU-OH), tolfenamic acid (TLF), meloxicam (MLX), diclofenac (DC), carprofen (CPF) and ketoprofen (KTP). Several extraction procedures had been investigated during the development phase. Finally, the best results were obtained with a procedure using only methanol as the extraction solvent, with an evaporation step included and no further purification. Chromatographic separation was achieved on a C18 analytical column and the run was split in 2 segments. Matrix effects were also investigated. Data acquisition implemented for the confirmatory purpose was performed by monitoring 2 MRM transitions per analyte under the negative electrospray mode. Mean relative recoveries ranged from 94.7% to 110.0%, with their coefficients of variation lying between 2.9% and 14.7%. Analytical limits expressed in terms of decision limits (CCα) were evaluated between 0.69 µg kg(-1) (FLU) and 27.54 µg kg(-1) (VDP) for non-MRL compounds, and at 0.10 (DC), 15.37 (MLX), 45.08 (FLU-OH), and 62.96 µg kg(-1) (TLF) for MRL compounds. The validation results proved that the method is suitable for the screening and confirmatory steps as implemented for the French monitoring plan for NSAID residue control in bovine milk.


Asunto(s)
Antiinflamatorios no Esteroideos/análisis , Cromatografía Liquida/métodos , Residuos de Medicamentos/análisis , Leche/química , Espectrometría de Masas en Tándem/métodos , Animales , Antiinflamatorios no Esteroideos/aislamiento & purificación , Bovinos , Femenino , Cabras , Ácido Clorhídrico , Metanol , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
J Chromatogr B Analyt Technol Biomed Life Sci ; 850(1-2): 15-23, 2007 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-17141581

RESUMEN

A liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed and validated for use in pharmacokinetic studies in order to determine the concentrations of monensin in plasma and edible tissues of chicken. Two sample preparations were performed, one for determining monensin concentrations in plasma using acetonitrile for protein precipitation and another one for determining monensin concentrations in muscle, liver, and fat using methanol-water followed by a clean up on a solid-phase extraction cartridge. Sample extracts were injected into the LC-MS/MS system, and a gradient elution was performed on a C18 column. Narasin was used as internal standard. The LC-MS/MS method was validated using an approach based on accuracy profiles, and applicability of the method was demonstrated for the determination of monensin in chicken plasma, muscle, liver, and fat in a pharmacokinetic study.


Asunto(s)
Antiprotozoarios/sangre , Cromatografía Liquida/métodos , Monensina/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos , Animales , Antiprotozoarios/farmacocinética , Calibración , Pollos , Monensina/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masas en Tándem/métodos , Distribución Tisular