Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Anal Chim Acta ; 1274: 341560, 2023 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-37455078

RESUMEN

The aim of the successive projections algorithm (SPA) is to enhance the accuracy of multiple linear regressions (MLR) by minimizing the impact of collinearity effects in the calibration data set. Combining SPA with MLR as a variable selection approach has resulted in the SPA-MLR method, which has been reported in literature to produce models with good prediction ability compared to conventional full-spectrum models obtained with partial-least-squares (PLS) in some cases. This paper proposes the addition of a filter step to the current version of the SPA algorithm to reduce the number of uninformative variables before the projection phase and assist the algorithm in selecting the best variables on subsequent steps. The proposed fSPA-MLR algorithm is evaluated in two case studies involving the near-infrared spectrometric analysis of pharmaceutical tablet and diesel/biodiesel mixture samples. Compared to PLS, the fSPA-MLR models demonstrate similar or better performance. Moreover, the fSPA-MLR models outperform the original SPA-MLR in both cross-validation and external prediction. The fSPA-MLR models deliver superior results regardless of the pre-processing algorithm tested, including first-derivative Savitzky-Golay (SG) and Standard Normal Variate (SNV), or even in raw spectra data.

2.
Food Chem ; 421: 136164, 2023 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-37099954

RESUMEN

Tea (Camellia sinensis) fraud has been frequently identified and involves tampering with the labelling of inferior products or without geographical origin certification and even mixing them with superior quality teas to mask an adulteration. Consequently, economic losses and health damage to consumers are observed. Thus, a Chemometrics-assisted Color Histogram-based Analytical System (CACHAS) was employed a simple, cost-effective, reliable, and green analytical tool to screen the quality of teas. Data-Driven Soft Independent Modeling of Class Analogy was used to authenticate their geographical origin and category simultaneously, recognizing correctly all Argentinean and Sri Lankan black teas and Argentinean green teas. For the determination of moisture, total polyphenols, and caffeine, Partial Least Squares obtained satisfactory predictive abilities, with values of root mean squared error of prediction (RMSEP) of 0.50, 0.788, and 0.25 mg kg-1, rpred of 0.81, 0.902, and 0.81, and relative error of prediction (REP) of 6.38, 9.031, and 14.58%., respectively. CACHAS proved to be a good alternative tool for environmentally-friendly non-destructive chemical analysis.


Asunto(s)
Camellia sinensis , Quimiometría , , Cafeína/análisis , Polifenoles/análisis
3.
ACS Appl Mater Interfaces ; 14(4): 5843-5855, 2022 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-35048694

RESUMEN

Near-infrared (NIR) radiation plays an important role in guided external stimulus therapies; its application in bone-related treatments is becoming more and more frequent. Therefore, metallic biomaterials that exhibit properties activated by NIR are promising for further orthopedic procedures. In this work, we present an adapted electroforming approach to attain a biomorphic nano-holed TiO2 coating on Ti6Al4V alloy. Through a precise control of the anodization conditions, structures revealed the formation of localized nano-pores arranged in a periodic assembly. This specific organization provoked higher stability against thermal oxidation and precise hydrophobic wettability behavior according to Cassie-Baxter's model; both characteristics are a prerequisite to ensure a favorable biological response in an implantable structure for guided bone regeneration. In addition, the periodically arranged sub-wavelength-sized unit cell on the metallic-dielectric structure exhibits a peculiar optical response, which results in higher NIR reflectivity. Accordingly, we have proved that this effect enhances the efficiency of the scattering processes and provokes a significant improvement of light confinement producing a spontaneous NIR fluorescence emission. The combination of the already favorable mechanical and biocompatibility properties of Ti6Al4V, along with suitable thermal stability, wetting, and electro-optical behavior, opens a promising path toward strategic bone therapeutic procedures.


Asunto(s)
Aleaciones/química , Materiales Biomiméticos/química , Materiales Biocompatibles Revestidos/química , Aleaciones/efectos de la radiación , Materiales Biomiméticos/efectos de la radiación , Materiales Biocompatibles Revestidos/efectos de la radiación , Interacciones Hidrofóbicas e Hidrofílicas , Rayos Infrarrojos , Porosidad , Titanio/química , Titanio/efectos de la radiación , Humectabilidad
4.
J Phys Chem B ; 124(12): 2425-2435, 2020 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-32134662

RESUMEN

In this work, the combination of experimental and theoretical results was employed to confirm an interaction between Cdots and AgNPs in the silver/Cdots hybrid nanoparticles. The experimental data obtained by UV-vis, IR, ζ potential, and TGA techniques were correlated and interpreted by calculations obtained by DFT. In particular, an interaction between the -COO- functional group of the Cdots with AgNPs was revealed. As consequence of this interaction, a frequency shift and a higher absorption intensity in the IR of the -OH group in the Cdots was theoretically predicted and also observed in the experimental IR spectra. Moreover, a bonding and charge distribution analysis was also carried out. These results constitute new physical insight for the Ag@Cdots system. Additionally, based in this type of interaction, energy calculations explained the negative charge surrounding the AgNPs, which was detected by ζ potential measurements. This systematic methodology not only is useful for this nanoparticles system but also could be used to analyze the interaction between the components that constitute other types of hybrid nanoparticles.

5.
Spectrochim Acta A Mol Biomol Spectrosc ; 189: 300-306, 2018 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-28834784

RESUMEN

Determining fat content in hamburgers is very important to minimize or control the negative effects of fat on human health, effects such as cardiovascular diseases and obesity, which are caused by the high consumption of saturated fatty acids and cholesterol. This study proposed an alternative analytical method based on Near Infrared Spectroscopy (NIR) and Successive Projections Algorithm for interval selection in Partial Least Squares regression (iSPA-PLS) for fat content determination in commercial chicken hamburgers. For this, 70 hamburger samples with a fat content ranging from 14.27 to 32.12mgkg-1 were prepared based on the upper limit recommended by the Argentinean Food Codex, which is 20% (ww-1). NIR spectra were then recorded and then preprocessed by applying different approaches: base line correction, SNV, MSC, and Savitzky-Golay smoothing. For comparison, full-spectrum PLS and the Interval PLS are also used. The best performance for the prediction set was obtained for the first derivative Savitzky-Golay smoothing with a second-order polynomial and window size of 19 points, achieving a coefficient of correlation of 0.94, RMSEP of 1.59mgkg-1, REP of 7.69% and RPD of 3.02. The proposed methodology represents an excellent alternative to the conventional Soxhlet extraction method, since waste generation is avoided, yet without the use of either chemical reagents or solvents, which follows the primary principles of Green Chemistry. The new method was successfully applied to chicken hamburger analysis, and the results agreed with those with reference values at a 95% confidence level, making it very attractive for routine analysis.


Asunto(s)
Algoritmos , Alimentos , Lípidos/análisis , Espectroscopía Infrarroja Corta/métodos , Animales , Calibración , Pollos , Análisis de los Mínimos Cuadrados , Modelos Lineales , Análisis Multivariante
6.
Luminescence ; 32(7): 1227-1232, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28512775

RESUMEN

The quantification of zinc in over-the-counter drugs as commercial propolis extracts by molecular fluorescence technique using meso-tetrakis(4-carboxyphenyl)porphyrin (H2 TCPP4 ) was developed for the first time. The calibration curve is linear from 6.60 to 100 nmol L-1 of Zn2+ . The detection and quantification limits were 6.22 nmol L-1 and 19.0 nmol L-1 , respectively. The reproducibility and repeatability calculated as the percentage variation of slopes of seven calibration curves were 6.75% and 4.61%, respectively. Commercial propolis extract samples from four Brazilian states were analyzed and the results (0.329-0.797 mg/100 mL) obtained with this method are in good agreement with that obtained with the Atomic Absorption Spectroscopy (AAS) technique. The method is simple, fast, of low cost and allows the analysis of the samples without pretreatment. Moreover the major advantage is that Zn-porphyrin complex presents fluorescent characteristic promoting the selectivity and sensitivity of the method.


Asunto(s)
Própolis/análisis , Espectrometría de Fluorescencia/métodos , Zinc/análisis , Brasil , Calibración , Colorantes Fluorescentes/química , Mesoporfirinas/química , Porfirinas/química , Própolis/química , Reproducibilidad de los Resultados , Espectrofotometría Atómica/métodos , Espectrofotometría Ultravioleta
7.
Food Chem ; 192: 374-9, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26304362

RESUMEN

In this work we proposed a method to verify the differentiating characteristics of simple tea infusions prepared in boiling water alone (simulating a home-made tea cup), which represents the final product as ingested by the consumers. For this purpose we used UV-Vis spectroscopy and variable selection through the Successive Projections Algorithm associated with Linear Discriminant Analysis (SPA-LDA) for simultaneous classification of the teas according to their variety and geographic origin. For comparison, KNN, CART, SIMCA, PLS-DA and PCA-LDA were also used. SPA-LDA and PCA-LDA provided significantly better results for tea classification of the five studied classes (Argentinean green tea; Brazilian green tea; Argentinean black tea; Brazilian black tea; and Sri Lankan black tea). The proposed methodology provides a simpler, faster and more affordable classification of simple tea infusions, and can be used as an alternative approach to traditional tea quality evaluation as made by skilful tasters, which is evidently partial and cannot assess geographic origins.


Asunto(s)
Camellia sinensis/química , Inspección de Alimentos/métodos , Espectrofotometría Ultravioleta/métodos , Té/química , Té/clasificación , Algoritmos , Argentina , Brasil , Camellia sinensis/crecimiento & desarrollo , Análisis Discriminante , Geografía , Análisis de los Mínimos Cuadrados , Análisis de Componente Principal , Sri Lanka
8.
Talanta ; 114: 38-42, 2013 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-23953438

RESUMEN

This paper proposes a flow-batch methodology for the determination of free glycerol in biodiesel that is notably eco-friendly, since non-chemical reagents are used. Deionized water (the solvent) was used alone for glycerol (sample) extractions from the biodiesel. The same water was used to generate water-cavitation sonoluminescence signals, which were modulated by the quenching effect associated with the amount of extracted glycerol. The necessarily reproducible signal generation was achieved by using a simple and inexpensive piezoelectric device. A linear response was observed for glycerol within the 0.001-100 mg/L range, equivalent to 0.004-400 mg/kg free glycerol in biodiesel. The lowest measurable concentration of free glycerol was estimated at 1.0 µg/L. The selectivity of the proposed method was confirmed by comparing the shape and retention of both real and calibration samples to standard solution chromatograms, presenting no peaks other than glycerol. All samples (after extraction) are greatly diluted; this minimizes (toward non-detectability) potential interference effects. The methodology was successfully applied to biodiesel analysis at a high sampling rate, with neither reagent nor solvent (other than water), and with minimum waste generation. The results agreed with the reference method (ASTM D6584-07), at a 95% confidence level.


Asunto(s)
Biocombustibles/análisis , Glicerol/análisis , Tecnología Química Verde , Mediciones Luminiscentes
SELECCIÓN DE REFERENCIAS