Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 43(11): 1597-1602, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36229165

RESUMEN

BACKGROUND AND PURPOSE: Radiographic shunt series are still the imaging technique of choice for radiologic evaluation of VP-shunt complications. Radiographic shunt series are associated with high radiation exposure and have a low diagnostic performance. Our aim was to investigate the diagnostic performance of whole-body ultra-low-dose CT for detecting mechanical ventriculoperitoneal shunt complications. MATERIALS AND METHODS: This retrospective study included 186 patients (mean age, 54.8 years) who underwent whole-body ultra-low-dose CT (100 kV[peak]; reference, 10 mAs). Two radiologists reviewed the images for the presence of ventriculoperitoneal shunt complications, image quality, and diagnostic confidence. On a 5-point Likert scale, readers scored image quality and diagnostic confidence (1 = very low, 5 = very high). Sensitivity, specificity, positive predictive value, and negative predictive value were calculated. Radiation dose estimation of whole-body ultra-low-dose CT was calculated and compared with the radiation dose of a radiographic shunt series. RESULTS: 34 patients positive for VP-shunt complications were correctly identified on whole-body ultra-low-dose CT by both readers. No false-positive or -negative cases were recorded by any of the readers, yielding a sensitivity of 100% (95% CI, 87.3%-100%), a specificity of 100% (95% CI, 96.9%-100%), and perfect agreement (κ = 1). Positive and negative predictive values were high at 100%. Shunt-specific image quality and diagnostic confidence were very high (median score, 5; range, 5-5). Interobserver agreement was substantial for image quality (κ = 0.73) and diagnostic confidence (κ = 0.78). The mean radiation dose of whole-body ultra-low-dose CT was significantly lower than the radiation dose of a conventional radiographic shunt series (0.67 [SD, 0.4] mSv versus 1.57 [SD, 0.6] mSv; 95% CI, 0.79-1.0 mSv; P < .001). CONCLUSIONS: Whole-body ultra-low-dose CT allows detection of ventriculoperitoneal shunt complications with excellent diagnostic accuracy and diagnostic confidence. With concomitant radiation dose reduction on contemporary CT scanners, whole-body ultra-low-dose CT should be considered an alternative to the radiographic shunt series.


Asunto(s)
Exposición a la Radiación , Derivación Ventriculoperitoneal , Humanos , Persona de Mediana Edad , Derivación Ventriculoperitoneal/efectos adversos , Estudios Retrospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Sensibilidad y Especificidad
2.
Clin Radiol ; 73(2): 218.e9-218.e15, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28811040

RESUMEN

AIM: To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. METHODS: The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n=20; clipping: n=15; coiling + stenting: n=9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-images (1.5 or 3 T). Nominal data were analysed using McNemar's chi-square test and ordinal variables using the Wilcoxon rank test. RESULTS: Compared to TOF-MRA, MAR-FPCTA was significantly better suited to detect aneurysm remnants and to evaluate parent vessels after clipping (p<0.01). For coil packages >160 mm3, TOF-MRA provided significantly better assessment than MAR-FPCTA (p<0.01). For small coil packages (<160 mm3), no significant difference between TOF-MRA and MAR-FPCTA (p=0.232) was observed. For different clip sizes (cut-off 492 mm3) likewise no significant differences were found. The interobserver comparison showed high interrater agreement. CONCLUSION: MAR-FPCTA is significantly better suited for follow-up examinations of clipped aneurysms, whereas for larger coil packages TOF-MRA is preferable. Smaller coil packages can be analysed using MAR-FPCTA or TOF-MRA.


Asunto(s)
Artefactos , Angiografía Cerebral/métodos , Angiografía por Tomografía Computarizada/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Angiografía por Tomografía Computarizada/instrumentación , Medios de Contraste , Estudios de Seguimiento , Humanos , Aumento de la Imagen/métodos , Aneurisma Intracraneal/terapia , Metales , Prótesis e Implantes , Estudios Retrospectivos , Stents , Instrumentos Quirúrgicos
3.
GMS J Med Educ ; 33(4): Doc54, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27579354

RESUMEN

The competent physical examination of patients and the safe and professional implementation of clinical procedures constitute essential components of medical practice in nearly all areas of medicine. The central objective of the projects "Heidelberg standard examination" and "Heidelberg standard procedures", which were initiated by students, was to establish uniform interdisciplinary standards for physical examination and clinical procedures, and to distribute them in coordination with all clinical disciplines at the Heidelberg University Hospital. The presented project report illuminates the background of the initiative and its methodological implementation. Moreover, it describes the multimedia documentation in the form of pocketbooks and a multimedia internet-based platform, as well as the integration into the curriculum. The project presentation aims to provide orientation and action guidelines to facilitate similar processes in other faculties.


Asunto(s)
Curriculum , Educación de Pregrado en Medicina , Examen Físico , Docentes , Humanos , Medicina
5.
AJNR Am J Neuroradiol ; 36(6): 1162-6, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25678479

RESUMEN

BACKGROUND AND PURPOSE: Coil migration is a potentially serious complication of endovascular aneurysm treatment. The aim of the study was to systematically investigate the effectiveness of coil retrieval with a stent retriever in an animal model. MATERIALS AND METHODS: A total of 148 coils of various types and sizes were placed into arteries of varying diameters in a porcine in vivo model. Coil retrieval was performed by placing a Trevo ProVue stent retriever over the coil and trying to trap a part of the platinum coil within the stent mesh by advancing the microcatheter over the stent or simply by retrieving the stent without trying to trap the coil by advancing the microcatheter. RESULTS: Coil retrieval was successful in 101 of 102 cases (99%), in which trapping of the coil within the stent retriever by advancing the microcathter was applied. When we only pulled back the stent without trapping the coil, retrieval was successful in only 5 of 46 cases (11%). Coil type, coil structure (2D versus 3D), actual coil shape in the affected vessel, investigator experience, aspiration, coil localization, and vessel diameter had no significant influence on retrieval outcome. There was no case of vessel perforation. CONCLUSIONS: Retrieval of migrated platinum coils with a stent retriever is an effective treatment option for migrated coils when the correct technique is applied.


Asunto(s)
Modelos Animales de Enfermedad , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Migración de Cuerpo Extraño/terapia , Aneurisma Intracraneal/terapia , Platino (Metal) , Stents , Angiografía , Animales , Embolización Terapéutica/métodos , Diseño de Equipo , Femenino , Fluoroscopía , Arteria Subclavia/diagnóstico por imagen , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...