Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
IEEE Open J Eng Med Biol ; 5: 107-124, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38445239

RESUMEN

Emerging computational tools such as healthcare digital twin modeling are enabling the creation of patient-specific surgical planning, including microwave ablation to treat primary and secondary liver cancers. Healthcare digital twins (DTs) are anatomically one-to-one biophysical models constructed from structural, functional, and biomarker-based imaging data to simulate patient-specific therapies and guide clinical decision-making. In microwave ablation (MWA), tissue-specific factors including tissue perfusion, hepatic steatosis, and fibrosis affect therapeutic extent, but current thermal dosing guidelines do not account for these parameters. This study establishes an MR imaging framework to construct three-dimensional biophysical digital twins to predict ablation delivery in livers with 5 levels of fat content in the presence of a tumor. Four microwave antenna placement strategies were considered, and simulated microwave ablations were then performed using 915 MHz and 2450 MHz antennae in Tumor Naïve DTs (control), and Tumor Informed DTs at five grades of steatosis. Across the range of fatty liver steatosis grades, fat content was found to significantly increase ablation volumes by approximately 29-l42% in the Tumor Naïve and 55-60% in the Tumor Informed DTs in 915 MHz and 2450 MHz antenna simulations. The presence of tumor did not significantly affect ablation volumes within the same steatosis grade in 915 MHz simulations, but did significantly increase ablation volumes within mild-, moderate-, and high-fat steatosis grades in 2450 MHz simulations. An analysis of signed distance to agreement for placement strategies suggests that accounting for patient-specific tumor tissue properties significantly impacts ablation forecasting for the preoperative evaluation of ablation zone coverage.

3.
Radiology ; 310(1): e230453, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38259204

RESUMEN

Background Splenic biopsy is rarely performed because of the perceived risk of hemorrhagic complications. Purpose To evaluate the safety of large bore (≥18 gauge) image-guided splenic biopsy. Materials and Methods This retrospective study included consecutive adult patients who underwent US- or CT-guided splenic biopsy between March 2001 and March 2022 at eight academic institutions in the United States. Biopsies were performed with needles that were 18 gauge or larger, with a comparison group of biopsies with needles smaller than 18 gauge. The primary outcome was significant bleeding after the procedure, defined by the presence of bleeding at CT performed within 30 days or angiography and/or surgery performed to manage the bleeding. Categorical variables were compared using the χ2 test and medians were compared using the Mann-Whitney test. Results A total of 239 patients (median age, 63 years; IQR, 50-71 years; 116 of 239 [48.5%] female patients) underwent splenic biopsy with an 18-gauge or smaller needle and 139 patients (median age, 58 years [IQR, 49-69 years]; 66 of 139 [47.5%] female patients) underwent biopsy with a needle larger than 18 gauge. Bleeding was detected in 20 of 239 (8.4%) patients in the 18-gauge or smaller group and 11 of 139 (7.9%) in the larger than 18-gauge group. Bleeding was treated in five of 239 (2.1%) patients in the 18-gauge or smaller group and one of 139 (1%) in the larger than 18-gauge group. No deaths related to the biopsy procedure were recorded during the study period. Patients with bleeding after biopsy had smaller lesions compared with patients without bleeding (median, 2.1 cm [IQR, 1.6-5.4 cm] vs 3.5 cm [IQR, 2-6.8 cm], respectively; P = .03). Patients with a history of lymphoma or leukemia showed a lower incidence of bleeding than patients without this history (three of 90 [3%] vs 28 of 288 [9.7%], respectively; P = .05). Conclusion Bleeding after splenic biopsy with a needle 18 gauge or larger was similar to biopsy with a needle smaller than 18 gauge and seen in 8% of procedures overall, with 2% overall requiring treatment. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Grant in this issue.


Asunto(s)
Biopsia Guiada por Imagen , Agujas , Bazo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía , Biopsia Guiada por Imagen/efectos adversos , Agujas/efectos adversos , Agujas/estadística & datos numéricos , Estudios Retrospectivos , Bazo/diagnóstico por imagen , Bazo/patología , Anciano
4.
Hepatology ; 79(2): 380-391, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37548928

RESUMEN

BACKGROUND AND AIMS: The objective of this study is to determine the diagnostic accuracy of the American College of Radiology Contrast-Enhanced Ultrasound (CEUS) Liver Imaging Reporting and Data System LR-5 characterization for HCC diagnosis in North American or European patients. APPROACH AND RESULTS: A prospective multinational cohort study was performed from January 2018 through November 2022 at 11 academic and nonacademic centers in North America and Europe. Patients at risk for HCC with at least 1 liver observation not previously treated, identified on ultrasound (US), or multiphase CT or MRI performed as a part of standard clinical care were eligible for the study. All participants were examined with CEUS of the liver within 4 weeks of CT/MRI or tissue diagnosis to characterize up to 2 liver nodules per participant using ACR CEUS Liver Imaging Reporting and Data System. Definite HCC diagnosis on the initial CT/MRI, imaging follow-up, or histology for CT/MRI-indeterminate nodules were used as reference standards. A total of 545 nodules had confirmed reference standards in 480 patients, 73.8% were HCC, 5.5% were other malignancies, and 20.7% were nonmalignant. The specificity of CEUS LR-5 for HCC was 95.1% (95% CI 90.1%-97.7%), sensitivity 62.9% (95% CI 57.9%-67.7%), positive predictive value 97.3% (95% CI 94.5%-98.7%), and negative predictive value 47.7% (95% CI 41.7%-53.8%). In addition, benign CEUS characterization (LR-1 or LR-2) had 100% specificity and 100% positive predictive value for nonmalignant liver nodules. CONCLUSIONS: CEUS Liver Imaging Reporting and Data System provides an accurate categorization of liver nodules in participants at risk for HCC.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Estudios Prospectivos , Estudios de Cohortes , Medios de Contraste , Estudios Retrospectivos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Europa (Continente) , América del Norte , Sensibilidad y Especificidad
5.
medRxiv ; 2023 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-38045245

RESUMEN

Background: Lung nodule incidence is increasing. Many nodules require biopsy to discriminate between benign and malignant etiologies. The gold-standard for minimally invasive biopsy, computed tomography-guided transthoracic needle biopsy (CT-TTNB), has never been directly compared to navigational bronchoscopy, a modality which has recently seen rapid technological innovation and is associated with improving diagnostic yield and lower complication rate. Current estimates of the diagnostic utility of both modalities are based largely on non-comparative data with significant risk for selection, referral, and publication biases. Methods: The VERITAS trial (na V igation E ndoscopy to R each Indeterminate lung nodules versus T ransthoracic needle A spiration, a randomized controlled S tudy) is a multicenter, 1:1 randomized, parallel-group trial designed to ascertain whether electromagnetic navigational bronchoscopy with integrated digital tomosynthesis is noninferior to CT-TTNB for the diagnosis of peripheral lung nodules 10-30 mm in diameter with pre-test probability of malignancy of at least 10%. The primary endpoint is diagnostic accuracy through 12 months follow-up. Secondary endpoints include diagnostic yield, complication rate, procedure duration, need for additional invasive diagnostic procedures, and radiation exposure. Discussion: The results of this rigorously designed trial will provide high-quality data regarding the management of lung nodules, a common clinical entity which often represents the earliest and most treatable stage of lung cancer. Several design challenges are described. Notably, all nodules are centrally reviewed by an independent interventional pulmonology and radiology adjudication panel relying on pre-specified exclusions to ensure enrolled nodules are amenable to sampling by both modalities while simultaneously protecting against selection bias favoring either modality. Conservative diagnostic yield and accuracy definitions with pre-specified criteria for what non-malignant findings may be considered diagnostic were chosen to avoid inflation of estimates of diagnostic utility. Trial registration: ClinicalTrials.gov NCT04250194.

6.
Clin Imaging ; 101: 223-226, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37429168

RESUMEN

PURPOSE: The COVID-19 pandemic rapidly accelerated the adoption of virtual learning in medical education, including departmental grand rounds lectures in radiology. This retrospective study sought to assess the impact of an open access virtual grand rounds program. We tested the hypothesis that virtual grand rounds would advance learning equity by increasing access to learners outside of our institution. METHODS: Twenty-two open access virtual grand rounds lectures were presented and recorded using an online videoconferencing platform. After the lecture, registrants received online access to the lecture recording for later on-demand viewing. The email address, geographical location, institutional affiliation, and medical specialty for all virtual registrants and attendees were retrospectively collected from a required online registration form. The primary outcome measure included an assessment of geographical diversity using descriptive statistics. RESULTS: Attendees of the virtual lectures were from 75 academic institutions and 27 non-academic institutions and located in 32 states, 88 cities, and 9 countries. Twenty-seven medical specialties were represented. CONCLUSION: The virtual grand rounds program in radiology contributes to free and open access educational content online for learners around the world. To address learning equity and promote international inclusion, we recommend that grand rounds organizers consider including a virtual option that allows free sharing of knowledge.


Asunto(s)
COVID-19 , Radiología , Rondas de Enseñanza , Humanos , Estudios Retrospectivos , Pandemias
7.
Radiographics ; 43(5): e220090, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37079459

RESUMEN

Placenta accreta spectrum (PAS) disorders are a major cause of maternal morbidity and mortality and are increasing in incidence owing to a rising rate of cesarean delivery. US is the primary imaging tool for evaluation of PAS disorders, which are most often diagnosed during routine early second-trimester US to assess fetal anatomy. MRI serves as a complementary modality, providing value when the diagnosis is equivocal at US and evaluating the extent and topography of myoinvasion for surgical planning in severe cases. While the definitive diagnosis is established by a combined clinical and histopathologic classification at delivery, accurate antenatal diagnosis and multidisciplinary management are critical to guide treatment and ensure optimal outcomes for these patients. Many MRI features of PAS disorders have been described in the literature. To standardize assessment at MRI, the Society of Abdominal Radiology (SAR) and European Society of Urogenital Radiology (ESUR) released a joint consensus statement to provide guidance for image acquisition, image interpretation, and reporting of PAS disorders. The authors review the role of imaging in diagnosis of PAS disorders, describe the SAR-ESUR consensus statement with a pictorial review of the seven major MRI features recommended for use in diagnosis of PAS disorders, and discuss management of these patients. Familiarity with the spectrum of MRI findings of PAS disorders will provide the radiologist with the tools needed to more accurately diagnose this disease and make a greater impact on the care of these patients. ©RSNA, 2023 Supplemental material is available for this article. Quiz questions for this article are available through the Online Learning Center. See the invited commentary by Jha and Lyell in this issue.


Asunto(s)
Placenta Accreta , Radiología , Femenino , Humanos , Embarazo , Imagen por Resonancia Magnética/métodos , Placenta Accreta/diagnóstico por imagen , Placenta Accreta/epidemiología , Diagnóstico Prenatal/métodos , Radiografía Abdominal , Estudios Retrospectivos
9.
Abdom Radiol (NY) ; 48(5): 1637-1644, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36538081

RESUMEN

The management of pregnant patients with cancer is complex and requires a multidisciplinary team to effectively diagnose, stage, and manage the cancer while also being cognizant of the potential harm that diagnosis and treatment may have on the maternal and fetal well-being. Beyond the complex clinical management of these patients is additional medicolegal consideration. Radiologists play a crucial role in the management of these patients as their knowledge of diagnostic and interventional radiology techniques allows for appropriate and safe imaging for both the mother and fetus. In addition, radiologist are able to educate patient on the different imaging modalities and techniques, thus allowing patients to make informed decisions and maintain autonomy over there care. This article will review safety considerations associated with different imaging modalities, contrast agents, interventional radiology procedures and moderate sedation related to the imaging of pregnant patient with cancer with specific attention paid to the medicolegal aspects.


Asunto(s)
Neoplasias , Radiología Intervencionista , Embarazo , Femenino , Humanos , Diagnóstico por Imagen , Medios de Contraste , Neoplasias/complicaciones , Neoplasias/diagnóstico por imagen
10.
Abdom Radiol (NY) ; 47(8): 2697-2703, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35567618

RESUMEN

Thromboelastography (TEG) and rotational thromboelastometry are emerging technologies that are gaining increasing acceptance in the medical field to evaluate the coagulation status of patients on an individual level by assessing dynamic clot formation. TEG has been proven to reduce blood product use as well as improve patient outcomes in a variety of medical settings, including trauma and surgery due to the expediated nature of the test as well as the ability to determine specific deficiencies present in whole blood that are otherwise undetectable with traditional coagulation studies. Currently, no guidelines or recommendations are in place for the utilization of TEG in interventional or diagnostic radiology although access to TEG has become increasingly common in recent years. This manuscript presents a review of prior literature on the technical aspects of TEG as well as its use in various fields and explains the normal TEG-tracing parameters. Common hemodynamic abnormalities and their effect on the TEG tracing are illustrated, and the appropriate treatments for each abnormality are briefly mentioned. TEG has the potential to be a useful tool for determining the hemodynamic state of patients in both interventional and diagnostic radiology, and further research is needed to determine the value of these tests in the periprocedural setting.


Asunto(s)
Trastornos de la Coagulación Sanguínea , Tromboelastografía , Trastornos de la Coagulación Sanguínea/diagnóstico por imagen , Pruebas de Coagulación Sanguínea , Humanos , Radiólogos
11.
Abdom Radiol (NY) ; 47(3): 1167-1176, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35013750

RESUMEN

PURPOSE: To determine institutional practice requirements for personal protective equipment (PPE) in cross-sectional interventional radiology (CSIR) procedures among a variety of radiology practices in the USA and Canada. METHODS: Members of the Society of Abdominal Radiology (SAR) CSIR Emerging Technology Commission (ETC) were sent an eight-question survey about what PPE they were required to use during common CSIR procedures: paracentesis, thoracentesis, thyroid fine needle aspiration (FNA), superficial lymph node biopsy, deep lymph node biopsy, solid organ biopsy, and ablation. Types of PPE evaluated were sterile gloves, surgical masks, gowns, surgical hats, eye shields, foot covers, and scrubs. RESULTS: 26/38 surveys were completed by respondents at 20/22 (91%) institutions. The most common PPE was sterile gloves, required by 20/20 (100%) institutions for every procedure. The second most common PPE was masks, required by 14/20 (70%) institutions for superficial and deep procedures and 12/12 (100%) institutions for ablation. Scrubs, sterile gowns, eye shields, and surgical hats were required at nearly all institutions for ablation, whereas approximately half of institutions required their use for deep lymph node and solid organ biopsy. Compared with other types of PPE, required mask and eye shield use showed the greatest increase during the SARS-CoV-2 pandemic. CONCLUSION: PPE use during common cross-sectional procedures is widely variable. Given the environmental and financial impact and lack of consensus practice, further studies examining the appropriate level of PPE are needed.


Asunto(s)
COVID-19 , Equipo de Protección Personal , Estudios Transversales , Humanos , Radiología Intervencionista , SARS-CoV-2
12.
Abdom Radiol (NY) ; 47(8): 2584-2603, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34410433

RESUMEN

Percutaneous pancreatic interventions performed by abdominal radiologists play important diagnostic and therapeutic roles in the management of a wide range of pancreatic pathology. While often performed with endoscopy, pancreatic mass biopsy obtained via a percutaneous approach may serve as the only feasible option for diagnosis in patients with post-surgical anatomy, severe cardiopulmonary conditions, or prior non-diagnostic endoscopic attempts. Biopsy of pancreatic transplants are commonly performed percutaneously due to inaccessible location of the allograft by endoscopy, usually in the right lower quadrant or pelvis. Percutaneous drainage of collections in acute pancreatitis is primarily indicated for infection with clinical deterioration and may be performed alone or in combination with endoscopic drainage. Post-surgical pancreatic collections related to pancreatic duct fistula or leak also often warrant therapeutic percutaneous drainage. Knowledge of appropriate indications, strategies of approach, technique, and complications associated with these procedures is critical for a successful clinical practice.


Asunto(s)
Conductos Pancreáticos , Pancreatitis , Enfermedad Aguda , Biopsia , Drenaje/métodos , Endoscopía Gastrointestinal , Humanos , Páncreas/diagnóstico por imagen , Páncreas/patología , Páncreas/cirugía , Conductos Pancreáticos/patología , Pancreatitis/complicaciones , Resultado del Tratamiento
14.
Curr Urol Rep ; 22(1): 3, 2021 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-33403460

RESUMEN

PURPOSE OF REVIEW: The goal of this paper was to review the novel treatment modality of high-intensity transurethral directional ultrasound for prostate cancer. RECENT FINDINGS: Prostate cancer is a heterogeneous disease with some patients electing for active surveillance and focal therapies instead of definitive treatment with radical prostatectomy or radiation therapy. Prostate MRI has become a cornerstone of prostate cancer diagnosis, targeted biopsy, and treatment planning. Transurethral high-intensity directional ultrasound allows for MRI-guided ablation of the prostate gland with the ability to contour boundaries and spare critical structures, such as the neurovascular bundle and urinary sphincter. Although results are still emerging, this may offer patients a new option for focal therapy with a favorable side-effect profile. High-intensity transurethral directional ultrasound is an emerging treatment modality for both whole-gland and focal ablation with promising early results. Further research is needed to establish safety, tolerability, and long-term oncologic outcomes.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Imagen por Resonancia Magnética/métodos , Prostatectomía/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Resección Transuretral de la Próstata , Biopsia , Cistoscopía , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Humanos , Masculino , Próstata/diagnóstico por imagen , Próstata/cirugía , Neoplasias de la Próstata/patología , Cirugía Asistida por Computador/métodos , Resección Transuretral de la Próstata/métodos , Resultado del Tratamiento
15.
Front Physiol ; 12: 820251, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35185606

RESUMEN

Computational tools are beginning to enable patient-specific surgical planning to localize and prescribe thermal dosing for liver cancer ablation therapy. Tissue-specific factors (e.g., tissue perfusion, material properties, disease state, etc.) have been found to affect ablative therapies, but current thermal dosing guidance practices do not account for these differences. Computational modeling of ablation procedures can integrate these sources of patient specificity to guide therapy planning and delivery. This paper establishes an imaging-data-driven framework for patient-specific biophysical modeling to predict ablation extents in livers with varying fat content in the context of microwave ablation (MWA) therapy. Patient anatomic scans were segmented to develop customized three-dimensional computational biophysical models and mDIXON fat-quantification images were acquired and analyzed to establish fat content and determine biophysical properties. Simulated patient-specific microwave ablations of tumor and healthy tissue were performed at four levels of fatty liver disease. Ablation models with greater fat content demonstrated significantly larger treatment volumes compared to livers with less severe disease states. More specifically, the results indicated an eightfold larger difference in necrotic volumes with fatty livers vs. the effects from the presence of more conductive tumor tissue. Additionally, the evolution of necrotic volume formation as a function of the thermal dose was influenced by the presence of a tumor. Fat quantification imaging showed multi-valued spatially heterogeneous distributions of fat deposition, even within their respective disease classifications (e.g., low, mild, moderate, high-fat). Altogether, the results suggest that clinical fatty liver disease levels can affect MWA, and that fat-quantitative imaging data may improve patient specificity for this treatment modality.

19.
Abdom Radiol (NY) ; 44(1): 227-233, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30073402

RESUMEN

PURPOSE: To describe and validate a novel CT approach using volumetric analysis for renal stone surveillance. MATERIALS AND METHODS: This prospective trial consisted of a standard low-dose non-contrast CT (SLD) of the abdomen and pelvis, immediately followed by an ultra-low-dose non-contrast CT (ULD) with reconstruction limited to the kidneys. A novel dedicated software tool was applied that automates stone volume, density, and maximum linear size. Manual linear stone size was measured by a radiology fellow and urology resident for comparison. CT dose and clinical charges were considered. RESULTS: Twenty-eight stones in 16 patients were analyzed. Mean effective dose of ULD CT was 0.57 mSv, an average 92% lower than the SLD CT dose. For SLD, mean size ± SD (range) (mm) was 7.9 ± 6.2 (2.6-30.5) for Reader 1, 7.3 ± 6 (2.4-30.7) for Reader 2, and 9.3 ± 6.4 (3.7-33.1) for the automated software. For ULD, mean size ± SD (range) (mm) was 7.3 ± 6 (2.5-30.5) for Reader 1, 7.2 ± 6.1 (2.1-30.7) for Reader 2, and 9.1 ± 6.4 (4.2-32.8) for the automated software. Automated stone diameters were larger than manual diameters for 27/28 stones (mean difference, 23%); difference was ≥ 2 mm in 30%. Average variability between manual measurements was 8.6% (SLD) and 7.8% (ULD), but was 0% for the automated technique. Our institutional charge for ULD renal CT is slightly less than renal US, and > 4× less than SLD CT. The Medicare global fee for the ULD renal CT is less than the SLD CT of the abdomen and pelvis. CONCLUSIONS: This focused stone surveillance CT protocol is lower cost and lower dose compared to the standard CT approach. Automated assessment of stone burden provides improved reproducibility over manual linear measurement and offers the advantages of 3D measurements and volumetry. We now offer and perform this protocol in routine clinical practice for stone surveillance.


Asunto(s)
Cálculos Renales/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Riñón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
20.
Br J Radiol ; 92(1095): 20180631, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30457881

RESUMEN

Volumetric analysis is an objective three-dimensional assessment of a lesion or organ that may more accurately depict the burden of complex objects compared to traditional linear size measurement. Small changes in linear size are amplified by corresponding changes in volume, which could have significant clinical implications. Though early methods of calculating volumes were time-consuming and laborious, multiple software platforms are now available with varying degrees of user-software interaction ranging from manual to fully automated. For the assessment of primary malignancy and metastatic disease, volumetric measurements have shown utility in the evaluation of disease burden prior to and following therapy in a variety of cancers. Additionally, volume can be useful in treatment planning prior to resection or locoregional therapies, particularly for hepatic tumours. The utility of CT volumetry in a wide spectrum of non-oncologic pathology has also been described. While clear advantages exist in certain applications, some data have shown that volume is not always the superior method of size assessment and the associated labor intensity may not be worthwhile. Further, lack of uniformity among software platforms is a challenge to widespread implementation. This review will discuss CT volumetry and its potential oncologic and non-oncologic applications in abdominal imaging, as well as advantages and limitations to this quantitative technique.


Asunto(s)
Abdomen/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Imagenología Tridimensional/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Abdomen/patología , Neoplasias Abdominales/diagnóstico por imagen , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...