1.
Langmuir ; 32(28): 7070-8, 2016 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-27311591

RESUMEN

An impedimetric lectin biosensor for the detection of changes in the glycan structure of antibodies isolated from human serum is here correlated with the progression of rheumatoid arthritis (RA). The biosensor was built up from a mixed self-assembled monolayer (SAM) on gold consisting of two different thiolated zwitterionic derivatives, carboxybetaine and sulfobetaine, to resist nonspecific interactions. The carboxyl-terminated one was applied also for the covalent immobilization of lectin Ricinus communis agglutinin I (RCA-I). The process of building a bioreceptive layer was optimized and characterized using a diverse range of techniques. Impedimetric assays were integrated on a chip consisting of eight gold working electrodes, which is an important step toward the achievement of a moderate level of multiplexing for the analysis of human serum samples. At the end, the results obtained by the impedimetric analysis of immunoglobulins G (IgGs) isolated from serum samples were compared with those of two other standard bioanalytical methods employing lectins, that is, lectin microarrays (MAs) and enzyme-linked lectin binding assays (ELLBAs). The impedimetric results agreed very well with the DAS28 index (RA disease activity score 28), suggesting that impedimetric assays could be used for the development of a new diagnostic procedure sensitive to glycosylation changes in human IgGs and thus RA progression.


Asunto(s)
Artritis Reumatoide/sangre , Técnicas Biosensibles , Inmunoglobulina G/análisis , Lectinas de Plantas/química , Polisacáridos/análisis , Análisis por Matrices de Proteínas , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Electrodos , Glicosilación , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Polisacáridos/sangre , Análisis por Matrices de Proteínas/instrumentación , Análisis por Matrices de Proteínas/métodos
2.
Artículo en Inglés | MEDLINE | ID: mdl-25732978

RESUMEN

AIM: The aim of this pilot study was to acquire insight into the parameters of glycaemic control, especially, (1) the time delay (lag phase) between plasma and tissue glucose concentrations in relation to rise and fall in glucose levels and (2) the rate of glucose increase and decrease. METHODS: Four healthy people (HP), 4 people with type 1diabetes (DM1) and 4 with type 2 diabetes (DM2) underwent concurrent glucose measurements by means of (1) the continuous glucose monitoring system (CGMS-Medtronic), Medtronic-Minimed, CA, USA, calibrated by the glucometer Calla, Wellion, Austria, and, (2) the Beckman II analyser to measure glucose concentrations in venous plasma. Samples were taken on 4 consecutive days in the fasting state and 4 times after consumption of 50 g glucose. Carelink Personal, MS Excel, Maple and Mat lab were applied to plot the evolution of glucose concentration and analyse the results. The time difference between increase and decrease was calculated for HP, DM 1 and DM 2. RESULTS: In DM1and DM2, glucose tolerance testing (GTT) resulted in slower transport of glucose into subcutaneous tissue than in HP where the lag phase lasted up to 12 min. The maximum increase/decrease rates in DM1 and DM2 vs HP were 0.25 vs < 0.1 mmol/L/min. CONCLUSION: CGMS is shown to provide reliable plasma glucose concentrations provided the system is calibrated during a steady state. The analysis of glucose change rates improves understanding of metabolic processes better than standard GTT.


Asunto(s)
Glucemia/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Tejido Subcutáneo/metabolismo , Automonitorización de la Glucosa Sanguínea , Estudios Transversales , Ayuno/metabolismo , Femenino , Humanos , Masculino , Proyectos Piloto , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA