Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Orthop Traumatol Surg Res ; 110(2): 103792, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38081356

RESUMEN

INTRODUCTION: The pelvis plays a major role in the orientation of total hip arthroplasty (THA) implants and consequently, on the postoperative stability of the new hip joint. The relationship between the spine and pelvis affects the functional orientation of the acetabular cup, although this relationship differs between individuals and the positions encountered in everyday life. We believe this should be factored in when planning the THA procedure. This led us to conduct an in vivo ultrasound study to document the values of pelvic tilt in standing, sitting and lying positions in patients who have advanced hip osteoarthritis, before and after they undergo THA. HYPOTHESIS: The pelvic tilt when standing, sitting and lying supine does not change significantly after THA. MATERIALS AND METHODS: The pelvic tilt, defined as the angle between the anterior pelvic plane and a vertical line was measured using an ultrasound device in 30 patients before the THA procedure and again 6 months later in standing, sitting and lying positions. The measurements were done during an office visit with the patient on an examination table for the lying position, on a chair for the sitting position and with the heels and occiput against the wall for the standing position. RESULTS: The preoperative and 6-month postoperative pelvic tilt were -5.6̊±10.4̊ [-30.6̊; 11.7̊] and -5.8̊±7.9̊ [-20.6̊; 10.4̊] (p=0.4129) when standing, -44.5̊±6.10 [-53.8̊; -23.9̊] and -43.5̊±6.9̊ [-54.4̊; -17.3̊] (p=0.5760) when sitting, -88.3̊±5.1̊ [-99.3̊; -78.7̊] and -87.9̊±5.9̊ [-97.6̊; -72.4̊] (p=0.6106) when lying supine, respectively. There was no significant difference in the pelvic tilt before and 6 months after THA procedure. Variations of±5̊; ±5-10̊; ±10-15̊ and 15-20̊ were found in 72% (18); 20% (5); 4% (1) and 4% (1) of patients when lying supine, 56% (14); 36% (9); 8% (2); 0% (0) of patients when standing and 76% (19); 24% (6); 0% (0); 0% (0) when sitting. The mean variation for each patient between the preoperative and 6 months postoperative measurement was 4.8±3.4̊ [0.8̊; 10.4̊] (p=0.4129), 3.5±2.3̊ [0.2̊; 9.1̊] (p=0.5760), and 4.6̊±3.2̊ [1.2̊; 15.4̊] (p=0.6106) for the standing, sitting and lying positions respectively. CONCLUSION: The pelvic tilt does not significantly change 6 months after THA. Taking into account the various positions used in everyday life may help to optimize the implant position. We have described the use of an affordable, accurate and non-irradiating device that provides fast and easy measurements of pelvic tilt in various positions. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Acetábulo/cirugía , Postura , Columna Vertebral
2.
J Ultrasound Med ; 39(4): 667-674, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31665548

RESUMEN

OBJECTIVES: A new ultrasound-based device is proposed to measure the patient-specific pelvic tilt in different daily positions. The aim of this study was to assess the accuracy of this device as well as the intraobserver and interobserver precisions. METHODS: The accuracy was assessed by performing several tilt measurements with the device on a testing mechanical bench. The error was defined as the difference between the tilt measured with the device and the tilt provided by this test bench. Three physicians, a novice, an intermediate, and an expert user, were also asked to perform 10 measurements on 3 healthy volunteers with low, medium, and high body mass indices to analyze the intraobserver and interobserver precisions. These 10 measurements were performed in the standing, sitting, and supine positions. RESULTS: The mean accuracy of the device ± SD was 1.1° ± 0.7° (range, 0°-4.0°). The interobserver and intraobserver precisions were excellent whatever the body mass index and good to excellent according to the positions. There was no learning curve, and the time required to complete the measurements was approximately 5 minutes. CONCLUSIONS: This study presents an accurate and precise noninvasive device for measurement of the pelvic tilt in different positions.


Asunto(s)
Huesos Pélvicos/anatomía & histología , Huesos Pélvicos/fisiología , Postura/fisiología , Ultrasonografía/instrumentación , Ultrasonografía/métodos , Adulto , Índice de Masa Corporal , Competencia Clínica/estadística & datos numéricos , Humanos , Variaciones Dependientes del Observador , Estudios Prospectivos , Valores de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA