Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38884620

RESUMEN

BACKGROUND: To preserve the benefit of atrial sensing without the implantation of an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD) has been developed. The purpose of this nationwide survey was to provide an overview of the current key influences of device selection focusing on DX ICD and to test the applicability of a previously published decision-making flowchart of ICD-type selection. METHODS: An online questionnaire was sent to all implanting centers in Hungary. Eleven centers reported data from 361 DX ICD and 10 CRT-DX systems implantations between February 2021 and May 2023. RESULTS: The most important influencing clinical factors indicated by the participating doctors were elevated risk of atrial fibrillation (AF)/stroke (56%), risk of sinus/supraventricular tachycardias (SVT) (42%), and a potential need for CRT upgrade in the future (36%). The DX ICD was considered in the majority of cases instead of the VVI system (87%), and only in a small proportion instead of a DDD ICD (13%). 60% of the patients with DX ICDs were also included into remote monitoring-based follow-up. In 83% of the cases, good (>2 mV) or excellent (>5) atrial signal amplitude was recorded within 6 weeks after the implantation. CONCLUSION: In the current national survey, the most important influencing factors indicated by the implanters for selecting a DX ICD were the elevated risk of stroke or sinus/SVT and a potential need for CRT upgrade in the future. These findings support the use of a previously published decision-making flowchart.

2.
Diagnostics (Basel) ; 14(2)2024 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-38248008

RESUMEN

(1) Background: Besides the use of guideline-directed medical therapy (GDMT), multidisciplinary heart failure (HF) outpatient care (HFOC) is of strategic importance in HFrEF. (2) Methods: Data from 257 hospitalised HFrEF patients between 2019 and 2021 were retrospectively analysed. Application and target doses of GDMT were compared between HFOC and non-HFOC patients at discharge and at 1 year. 1-year all-cause mortality (ACM) and rehospitalisation (ACH) rates were compared using the Cox proportional hazard model. The effect of HFOC on GDMT and on prognosis after propensity score matching (PSM) of 168 patients and the independent predictors of 1-year ACM and ACH were also evaluated. (3) Results: At 1 year, the application of RASi, MRA and triple therapy (TT: RASi + ßB + MRA) was higher (p < 0.05) in the HFOC group, as was the proportion of target doses of ARNI, ßB, MRA and TT. After PSM, the composite of 1-year ACM or ACH was more favourable with HFOC (propensity-adjusted HR = 0.625, 95% CI = 0.401-0.974, p = 0.038). Independent predictors of 1-year ACM were age, systolic blood pressure, application of TT and HFOC, while 1-year ACH was influenced by the application of TT. (4) Conclusions: HFOC may positively impact GDMT use and prognosis in HFrEF even within the first year of its initiation.

3.
J Interv Card Electrophysiol ; 57(2): 295-301, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31342222

RESUMEN

PURPOSE: Pneumothorax (PTX) following cardiac implantable electronic device procedures is traditionally treated with chest tube drainage (CTD). We hypothesized that, in a subset of patients, the less invasive needle aspiration (NA) may also be effective. We compared the strategy of primary NA with that of primary CTD in a single-center observational study. METHODS: Of the 970 procedures with subclavian venous access between January 2016 and June 2018, 23 patients had PTX requiring intervention. Beginning with March 2017, the traditional primary CTD (9 cases) has been replaced by the "NA first" strategy (14 patients). Outcome measures were procedural success rate and duration of hospitalization evaluated both as time to event (log-rank test) and as a discrete variable (Wilcoxon-Mann-Whitney test). RESULTS: Needle aspiration was successful in 8/14 (57.1%) of the cases (95% CI 28.9-82.3%), whereas PTX resolved in all patients after CTD was 9/9 (100%, 95% CI 66.4-100.0%, p = 0.0481). Regarding length of hospital stay, intention to treat time to event analysis showed no difference between the two approaches (p = 0.73). Also, the median difference was not statistically significant (- 2.0 days, p = 0.17). In contrast, per protocol evaluation revealed reduced risk of prolonged hospitalization for NA patients (p = 0.0025) with a median difference of - 4.0 days (p = 0.0012). Failure of NA did not result in a meaningful delay in discharge timing as median difference was 1.5 days (p = 0.28). CONCLUSIONS: Our data suggest that in a number of patients iatrogenic PTX may be successfully treated with NA resulting in shorter hospitalization without the risk of meaningful discharge delay in unsuccessful cases.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Neumotórax/etiología , Neumotórax/terapia , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Succión/instrumentación , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Enfermedad Iatrogénica , Masculino , Agujas , Proyectos Piloto , Sistema de Registros
4.
J Med Internet Res ; 21(7): e14142, 2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-31350836

RESUMEN

BACKGROUND: Remote monitoring is an established, guideline-recommended technology with unequivocal clinical benefits; however, its ability to improve survival is contradictory. OBJECTIVE: The aim of our study was to investigate the effects of remote monitoring on mortality in an optimally treated heart failure patient population undergoing cardiac resynchronization defibrillator therapy (CRT-D) implantation in a large-volume tertiary referral center. METHODS: The population of this single-center, retrospective, observational study included 231 consecutive patients receiving CRT-D devices in the Medical Centre of the Hungarian Defence Forces (Budapest, Hungary) from January 2011 to June 2016. Clinical outcomes were compared between patients on remote monitoring and conventional follow-up. RESULTS: The mean follow-up time was 28.4 (SD 18.1) months. Patients on remote monitoring were more likely to have atrial fibrillation, received heart failure management at our dedicated heart failure outpatient clinic more often, and have a slightly lower functional capacity. Crude all-cause mortality of remote-monitored patients was significantly lower compared with patients followed conventionally (hazard ratio [HR] 0.368, 95% CI 0.186-0.727, P=.004). The survival benefit remained statistically significant after adjustment for important baseline parameters (adjusted HR 0.361, 95% CI 0.181-0.722, P=.004). CONCLUSIONS: In this single-center, retrospective study of optimally treated heart failure patients undergoing CRT-D implantation, the use of remote monitoring systems was associated with a significantly better survival rate.


Asunto(s)
Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/terapia , Telemedicina/métodos , Anciano , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...