Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Bioengineering (Basel) ; 10(9)2023 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-37760178

RESUMEN

The inferior vena cava (IVC) is the largest vein in the body. It returns deoxygenated blood to the heart from the tissues placed under the diaphragm. The size and dynamics of the IVC depend on the blood volume and right atrial pressure, which are important indicators of a patient's hydration and reflect possible pathological conditions. Ultrasound (US) assessment of the IVC is a promising technique for evaluating these conditions, because it is fast, non-invasive, inexpensive, and without side effects. However, the standard M-mode approach for measuring IVC diameter is prone to errors due to the vein movements during respiration. B-mode US produces two-dimensional images that better capture the IVC shape and size. In this review, we discuss the pros and cons of current IVC segmentation techniques for B-mode longitudinal and transverse views. We also explored several scenarios where automated IVC segmentation could improve medical diagnosis and prognosis.

2.
Bioengineering (Basel) ; 9(7)2022 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-35877316

RESUMEN

Aortic stiffness is an important clinical parameter for predicting cardiovascular events. Carotid-femoral pulse wave velocity (cf-PWV) has been proposed for performing this evaluation non-invasively; however, it requires dedicated equipment and experienced operators. We explored the possibility of measuring aortic stiffness using ultrasound scans of the abdominal aorta coupled with the Bramwell-Hill equation. Healthy subjects were investigated; measurements of cf-PWV were taken by arterial tonometry and aortic systo-diastolic pressure difference was estimated using a validated model. Pulsatility of an abdominal tract of aorta was assessed by automated processing of ultrasound scans. Through a Bland-Altmann analysis, we found large biases when estimating each parameter by applying the Bramwell-Hill equation to the measured values of the other two paramters (bias, ± 1.96 SD; PWV, about 2.1 ± 2.5 m/s; pulsatility, 12 ± 14%; pressure jump, 47 ± 55 mmHg). These results indicate that the two measures are not interchangeable, and that a large part of the bias is attributable to blood pressure estimation. Further studies are needed to identify the possible sources of bias between cf-PWV and aortic pulsatility.

3.
J Clin Med ; 11(12)2022 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-35743330

RESUMEN

The non-invasive estimation of right atrial pressure (RAP) would be a key advancement in several clinical scenarios, in which the knowledge of central venous filling pressure is vital for patients' management. The echocardiographic estimation of RAP proposed by Guidelines, based on inferior vena cava (IVC) size and respirophasic collapsibility, is exposed to operator and patient dependent variability. We propose novel methods, based on semi-automated edge-tracking of IVC size and cardiac collapsibility (cardiac caval index­CCI), tested in a monocentric retrospective cohort of patients undergoing echocardiography and right heart catheterization (RHC) within 24 h in condition of clinical and therapeutic stability (170 patients, age 64 ± 14, male 45%, with pulmonary arterial hypertension, heart failure, valvular heart disease, dyspnea, or other pathologies). IVC size and CCI were integrated with other standard echocardiographic features, selected by backward feature selection and included in a linear model (LM) and a support vector machine (SVM), which were cross-validated. Three RAP classes (low < 5 mmHg, intermediate 5−10 mmHg and high > 10 mmHg) were generated and RHC values used as comparator. LM and SVM showed a higher accuracy than Guidelines (63%, 71%, and 61% for LM, SVM, and Guidelines, respectively), promoting the integration of IVC and echocardiographic features for an improved non-invasive estimation of RAP.

4.
Sci Rep ; 12(1): 2155, 2022 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-35140261

RESUMEN

The influence of large vessels on near infrared spectroscopy (NIRS) measurement is generally considered negligible. Aim of this study is to test the hypothesis that changes in the vessel size, by varying the amount of absorbed NIR light, could profoundly affect NIRS blood volume indexes. Changes in haemoglobin concentration (tHb) and in tissue haemoglobin index (THI) were monitored over the basilic vein (BV) and over the biceps muscle belly, in 11 subjects (7 M - 4 F; age 31 ± 8 year) with simultaneous ultrasound monitoring of BV size. The arm was subjected to venous occlusion, according to two pressure profiles: slow (from 0 to 60 mmHg in 135 s) and rapid (0 to 40 mmHg maintained for 30 s). Both tHb and THI detected a larger blood volume increase (1.7 to 4 fold; p < 0.01) and exhibited a faster increase and a greater convexity on the BV than on the muscle. In addition, NIRS signals from BV exhibited higher correlation with changes in BV size than from muscle (r = 0.91 vs 0.55, p < 0.001 for THI). A collection of individual relevant recordings is also included. These results challenge the long-standing belief that the NIRS measurement is unaffected by large vessels and support the concept that large veins may be a major determinant of blood volume changes in multiple experimental conditions.


Asunto(s)
Volumen Sanguíneo , Músculo Esquelético/irrigación sanguínea , Espectroscopía Infrarroja Corta , Venas/anatomía & histología , Adulto , Hemoglobinas/análisis , Humanos , Masculino , Músculo Esquelético/anatomía & histología , Músculo Esquelético/química , Ultrasonografía , Venas/diagnóstico por imagen
5.
J Ultrasound Med ; 41(9): 2247-2258, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34877689

RESUMEN

OBJECTIVES: Inferior vena cava (IVC) pulsatility quantified by the Caval Index (CI) is characterized by poor reliability, also due to the irregular magnitude of spontaneous respiratory activity generating the major pulsatile component. The aim of this study was to test whether the IVC cardiac oscillatory component could provide a more stable index (Cardiac CI-CCI) compared to CI or respiratory CI (RCI). METHODS: Nine healthy volunteers underwent long-term monitoring in supine position of IVC, followed by 3 minutes passive leg raising (PLR). CI, RCI, and CCI were extracted from video recordings by automated edge-tracking and CCI was averaged over each respiratory cycle (aCCI). Cardiac output (CO), mean arterial pressure (MAP) and heart rate (HR) were also recorded during baseline (1 minutes prior to PLR) and PLR (first minute). RESULTS: In response to PLR, all IVC indices decreased (P < .01), CO increased by 4 ± 4% (P = .055) while HR and MAP did not vary. The Coefficient of Variation (CoV) of aCCI (13 ± 5%) was lower than that of CI (17 ± 5%, P < .01), RCI (26 ± 7%, P < .001) and CCI (25 ± 7%, P < .001). The mutual correlations in time of the indices were 0.81 (CI-RCI), 0.49 (CI-aCCI) and 0.2 (RCI-aCCI). CONCLUSIONS: Long-term IVC monitoring by automated edge-tracking allowed us to evidence that 1) respiratory and averaged cardiac pulsatility components are uncorrelated and thus carry different information and 2) the new index aCCI, exhibiting the lowest CoV while maintaining good sensitivity to blood volume changes, may overcome the poor reliability of CI and RCI.


Asunto(s)
Corazón , Vena Cava Inferior , Volumen Sanguíneo , Gasto Cardíaco , Humanos , Reproducibilidad de los Resultados , Vena Cava Inferior/diagnóstico por imagen
6.
Front Cardiovasc Med ; 8: 775635, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35127855

RESUMEN

Assessment of vascular size and of its phasic changes by ultrasound is important for the management of many clinical conditions. For example, a dilated and stiff inferior vena cava reflects increased intravascular volume and identifies patients with heart failure at greater risk of an early death. However, lack of standardization and sub-optimal intra- and inter- operator reproducibility limit the use of these techniques. To overcome these limitations, we developed two image-processing algorithms that quantify phasic vascular deformation by tracking wall movements, either in long or in short axis. Prospective studies will verify the clinical applicability and utility of these methods in different settings, vessels and medical conditions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...