Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Dalton Trans ; 53(14): 6445-6450, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38511259

RESUMEN

A neutral hexacoordinate Si(IV) complex containing two tridentate N-heterocyclic carbene ligands is synthesised and characterized by X-ray crystallography, optical spectroscopy, electrochemistry and computational methods. The stable compound exhibits remarkable deep-blue photoluminescence particularly in the solid state, which enables its use as an electroluminescent material in organic light-emitting diodes.

2.
Small Methods ; : e2301541, 2024 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-38368269

RESUMEN

Environmental pollution is a complex problem that threatens the health and life of animal and plant ecosystems on the planet. In this respect, the scientific community faces increasingly challenging tasks in designing novel materials with beneficial properties to address this issue. This study describes a simple yet effective synthetic protocol to obtain nickel hexacyanoferrate (Ni-HCF) nanocubes as a suitable photocatalyst, which can enable an efficient photodegradation of hazardous anthropogenic organic contaminants in water, such as antibiotics. Ni-HCF nanocubes are fully characterized and their optical and electrochemical properties are investigated. Preliminary tests are also carried out to photocatalytically remove metronidazole (MDZ), an antibiotic that is difficult to degrade and has become a common contaminant as it is widely used to treat infections caused by anaerobic microorganisms. Under simulated solar light, Ni-HCF displays substantial photocatalytic activity, degrading 94.3% of MDZ in 6 h. The remarkable performance of Ni-HCF nanocubes is attributeto a higher ability to separate charge carriers and to a lower resistance toward charge transfer, as confirmed by the electrochemical characterization. These achievements highlight the possibility of combining the performance of earth-abundant catalysts with a renewable energy source for environmental remediation, thus meeting the requirements for sustainable development.

3.
ChemistryOpen ; : e202300203, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38333968

RESUMEN

The growth of liquid biopsy, i. e., the possibility of obtaining health information by analysing circulating species (nucleic acids, cells, proteins, and vesicles) in peripheric biofluids, is pushing the field of sensors and biosensors beyond the limit to provide decentralised solutions for nonspecialists. In particular, among all the circulating species that can be adopted in managing cancer evolution, both for diagnostic and prognostic applications, microRNAs have been highly studied and detected. The development of electrochemical devices is particularly relevant for liquid biopsy purposes, and the screen-printed electrodes (SPEs) represent one of the building blocks for producing novel portable devices. In this work, we have taken miR-2115-3p as model target (it is related to lung cancer), and we have developed a biosensor by exploiting the use of a complementary DNA probe modified with methylene blue as redox mediator. In particular, the chosen sensing architecture was applied to serum measurements of the selected miRNA, obtaining a detection limit within the low nanomolar range; in addition, various platforms were interrogated, namely commercial and hand-made SPEs, with the aim of providing the reader with some insights about the optimal platform to be used by considering both the cost and the analytical performance.

4.
Angew Chem Int Ed Engl ; 62(51): e202309135, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-37672490

RESUMEN

Point-of-care (PoC) testing is revolutionizing the healthcare sector improving patient care in daily hospital practice and allowing reaching even remote geographical areas. In the frame of cancer management, the design and validation of PoC enabling the non-invasive, rapid detection of cancer markers is urgently required to implement liquid biopsy in clinical practice. Therefore, focusing on stable blood-based markers with high-specificity, such as microRNAs, is of crucial importance. In this work, we highlight the potential impact of circulating microRNAs detection on cancer management and the crucial role of PoC testing devices, especially for low-income countries. A detailed discussion about the challenges that should be faced to promote the technological transfer and clinical use of these tools has been added, to provide the readers with a complete overview of potentialities and current limitations.


Asunto(s)
MicroARNs , Neoplasias , Humanos , Pruebas en el Punto de Atención , Biopsia Líquida , Neoplasias/diagnóstico , Neoplasias/genética , Dispositivos Laboratorio en un Chip , Sistemas de Atención de Punto
5.
Angew Chem Int Ed Engl ; 62(38): e202305569, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37345993

RESUMEN

Two binuclear heteroleptic CuI complexes, namely Cu-NIR1 and Cu-NIR2, bearing rigid chelating diphosphines and π-conjugated 2,5-di(pyridin-2-yl)thiazolo[5,4-d]thiazole as the bis-bidentate ligand are presented. The proposed dinuclearization strategy yields a large bathochromic shift of the emission when compared to the mononuclear counterparts (M1-M2) and enables shifting luminescence into the near-infrared (NIR) region in both solution and solid state, showing emission maximum at ca. 750 and 712 nm, respectively. The radiative process is assigned to an excited state with triplet metal-to-ligand charge transfer (3 MLCT) character as demonstrated by in-depth photophysical and computational investigation. Noteworthy, X-ray analysis of the binuclear complexes unravels two interligand π-π-stacking interactions yielding a doubly locked structure that disfavours flattening of the tetrahedral coordination around the CuI centre in the excited state and maintain enhanced NIR luminescence. No such interaction is present in M1-M2. These findings prompt the successful use of Cu-NIR1 and Cu-NIR2 in NIR light-emitting electrochemical cells (LECs), which display electroluminescence maximum up to 756 nm and peak external quantum efficiency (EQE) of 0.43 %. Their suitability for the fabrication of white-emitting LECs is also demonstrated. To the best of our knowledge, these are the first examples of NIR electroluminescent devices based on earth-abundant CuI emitters.

6.
Biosens Bioelectron ; 213: 114477, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-35751954

RESUMEN

The use of synthetic bioreceptors to develop biosensing platforms has been recently gaining momentum. This case study compares the performance of a biosensing platform for the human biomarker urokinase-type plasminogen activator (h-uPA) when using two bicyclic peptides (P1 and P2) with different affinities for the target protein. The bioreceptors P1 and P2 were immobilized on magnetic microbeads and tested within a sandwich-type affinity electrochemical assay. Apart from enabling h-uPA quantification at nanomolar levels (105.8 ng/mL for P1 and 32.5 ng/mL for P2), this case study showed the potential of synthetic bicyclic peptides applicability and how bioreceptor affinity can influence the performance of the final sensing platform.


Asunto(s)
Técnicas Biosensibles , Neoplasias , Biomarcadores de Tumor , Humanos , Péptidos , Activador de Plasminógeno de Tipo Uroquinasa/metabolismo
7.
Biosensors (Basel) ; 12(5)2022 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-35624597

RESUMEN

Instrumental laboratory methods for biochemical and chemical analyses have reached a high level of reliability with excellent sensitivity and specificity [...].


Asunto(s)
Técnicas Biosensibles , Virus , Técnicas Biosensibles/métodos , Reproducibilidad de los Resultados
8.
Biosensors (Basel) ; 11(8)2021 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-34436048

RESUMEN

Peptides represent a promising class of biorecognition elements that can be coupled to electrochemical transducers. The benefits lie mainly in their stability and selectivity toward a target analyte. Furthermore, they can be synthesized rather easily and modified with specific functional groups, thus making them suitable for the development of novel architectures for biosensing platforms, as well as alternative labelling tools. Peptides have also been proposed as antibiofouling agents. Indeed, biofouling caused by the accumulation of biomolecules on electrode surfaces is one of the major issues and challenges to be addressed in the practical application of electrochemical biosensors. In this review, we summarise trends from the last three years in the design and development of electrochemical biosensors using synthetic peptides. The different roles of peptides in the design of electrochemical biosensors are described. The main procedures of selection and synthesis are discussed. Selected applications in clinical diagnostics are also described.


Asunto(s)
Incrustaciones Biológicas , Técnicas Biosensibles , Técnicas Electroquímicas , Electrodos , Péptidos
10.
Analyst ; 146(5): 1714-1724, 2021 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-33439175

RESUMEN

The anticancer drug imatinib is often involved in therapeutic drug monitoring (TDM) studies aimed at improving the treatment of several forms of leukemia and gastrointestinal stromal tumors (GIST). To further implement the TDM of imatinib in clinical practice, we developed a detection assay by using an ssDNA aptamer, which demonstrated excellent selectivity and was not affected by interference from the components of human plasma samples. The efficient binding of imatinib to the aptamer was demonstrated by means of surface plasmon resonance (SPR) analysis, which allowed the development of a quantitative assay in the concentration range between 400 and 6000 ng mL-1 (0.7-10 µM), where a lower limit of quantification (LLOQ) of 400 ng mL-1 was achieved. The precision of the assay was found to be within 12.0%, whereas the accuracy was in a range between 97.1 and 101.5%. The sample preparation procedure displayed a recovery in the range of 48.8-52.8%. Solid validation data were collected according to the regulatory guidelines and the method was compared with standard analytical techniques, leading to the development of a feasible aptasensor for the TDM of patients administered with imatinib.


Asunto(s)
Antineoplásicos , Tumores del Estroma Gastrointestinal , Antineoplásicos/uso terapéutico , Monitoreo de Drogas , Tumores del Estroma Gastrointestinal/tratamiento farmacológico , Humanos , Mesilato de Imatinib , Resonancia por Plasmón de Superficie
11.
Sensors (Basel) ; 20(23)2020 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-33260737

RESUMEN

Heavy metals ions (HMI), if not properly handled, used and disposed, are a hazard for the ecosystem and pose serious risks for human health. They are counted among the most common environmental pollutants, mainly originating from anthropogenic sources, such as agricultural, industrial and/or domestic effluents, atmospheric emissions, etc. To face this issue, it is necessary not only to determine the origin, distribution and the concentration of HMI but also to rapidly (possibly in real-time) monitor their concentration levels in situ. Therefore, portable, low-cost and high performing analytical tools are urgently needed. Even though in the last decades many analytical tools and methodologies have been designed to this aim, there are still several open challenges. Compared with the traditional analytical techniques, such as atomic absorption/emission spectroscopy, inductively coupled plasma mass spectrometry and/or high-performance liquid chromatography coupled with electrochemical or UV-VIS detectors, bio- and biomimetic electrochemical sensors provide high sensitivity, selectivity and rapid responses within portable and user-friendly devices. In this review, the advances in HMI sensing in the last five years (2016-2020) are addressed. Key examples of bio and biomimetic electrochemical, impedimetric and electrochemiluminescence-based sensors for Hg2+, Cu2+, Pb2+, Cd2+, Cr6+, Zn2+ and Tl+ are described and discussed.


Asunto(s)
Ecosistema , Metales Pesados , Biomimética , Monitoreo del Ambiente , Humanos , Iones , Metales Pesados/análisis , Medición de Riesgo
12.
Chemistry ; 26(51): 11751-11766, 2020 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-32632987

RESUMEN

A novel class of phosphorescent cationic heterobimetallic IrIII /MI complexes, where MI =CuI (4) and AuI (5), is reported. The two metal centers are connected by the hybrid bridging 1,3-dimesityl-5-acetylimidazol-2-ylidene-4-olate (IMesAcac) ligand that combines both a chelating acetylacetonato-like and a monodentate N-heterocyclic carbene site coordinated onto an IrIII and a MI center, respectively. Complexes 4 and 5 have been prepared straightforwardly by a stepwise site-selective metalation with the zwitterionic [(IPr)MI (IMesAcac)] metalloproligand (IPr=1,3-(2,6-diisopropylphenyl)-2H-imidazol-2-ylidene) and they have been fully characterized by spectroscopic, electrochemical, and computational investigation. Complexes 4 and 5 display intense red emission arising from a low-energy excited state that is located onto the "Ir(C^N)" moiety featuring an admixed triplet ligand-centered/metal-to-ligand charge transfer (3 IL/1 MLCT) character. Comparison with the benchmark mononuclear complexes reveals negligible electronic coupling between the two distal metal centers at the electronic ground state. The bimetallic systems display enhanced photophysical properties in comparison with the parental congeners. Noteworthy, similar non-radiative rate constants have been determined along with a two-fold increase of radiative rate, yielding brightly red-emitting cyclometalating IrIII complexes. This finding is ascribed to the increased MLCT character of the emitting state in complexes 4 and 5 due to the smaller energy gap between the 3 IL and 1 MLCT manifolds, which mix via spin-orbit coupling.

13.
Chemistry ; 26(38): 8407-8416, 2020 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-32430923

RESUMEN

We synthesized and characterized a series of dyes built from a spirofluorene or truxene core. The quadrupolar spirofluorene system is the initial building unit for the design and preparation of more complex star-shaped dyes consisting of a truxene core bearing three di- or triphenylamine moieties with or without a thiophene connector. Their photophysical, electrochemical, and electrochemiluminescence (ECL) properties were first investigated in solution. Structure/activity relationships were derived and rationalized by comparing the quadrupolar system and trigonal truxene-core derivatives using computational studies. The photophysical and redox characteristics are drastically tuned by the introduction of a thiophene bridge and electron-donor substituents at their terminal branches. These comparative studies show the essential role of the stability of both radical cations and anions to obtain efficient ECL dyes. The stabilization of the radicals is directly related to the charge delocalization due to the π-conjugation by the thiophene bridge. The brightest ECL is achieved by annihilation and coreactant (benzoyl peroxide) pathways with the blue-emitting truxene dye, which is 2- and 4.5-times greater than that of the quadrupolar compound and reference [Ru(bpy)3 ]2+ emitter, respectively. Such an extensive study on these extended π-conjugated molecules presenting different core structures may guide the design and synthesis of new ECL dyes with a strong efficiency.

14.
Sci Rep ; 10(1): 3016, 2020 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-32080226

RESUMEN

Circulating HER2 extracellular domain (HER2 ECD) levels were proposed as a surrogate for HER2 tissue expression to monitor breast cancer patients for early relapse or responses to standard or HER2-targeted therapies, such as the monoclonal antibody (mAb) trastuzumab. Currently, available commercial ELISA assays for HER2 ECD rely on antibodies recognizing undisclosed or unknown epitopes. In this work, two ELISA assays employing MGR2 and MGR3 epitope-specific mAbs for HER2 ECD were developed and validated, showing good assay precision and linearity of the dose-response signal within the dynamic range of 0.19-12.50 ng mL-1 and detection limits of 0.76 and 0.75 ng mL-1 for the MGR2 and MGR3 assays, respectively. The developed assay showed a good agreement with two widely used commercial kits for HER2 ECD quantification in serum samples from breast cancer patients. A complete characterization of mAb-HER2 ECD interaction was performed by means of surface plasmon resonance using trastuzumab as control for both epitope mapping and kinetics analysis. The epitopes recognized by the two mAbs showed no overlap with trastuzumab, which was confirmed by trastuzumab interference analysis in serum samples. The method showed to be a practical approach to determine HER2 ECD with a high degree of sensitivity, reliability and recovery in samples containing mAbs-based therapies.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Monitoreo de Drogas , Ensayo de Inmunoadsorción Enzimática/métodos , Epítopos/inmunología , Receptor ErbB-2/sangre , Trastuzumab/uso terapéutico , Anticuerpos Monoclonales/química , Unión Competitiva , Línea Celular Tumoral , Humanos , Cinética , Dominios Proteicos , Estándares de Referencia , Reproducibilidad de los Resultados
15.
Dalton Trans ; 49(10): 3102-3111, 2020 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-32065186

RESUMEN

Two novel rhenium(i) tricarbonyl complexes of general formula fac-[Re(N^C:)(CO)3X] are herein presented, where N^C: is the pyridoannelated N-heterocyclic carbene (NHC) arising from 2-(2-pyridinyl)imidazo[1,5-a]pyridinium hexafluorophosphate proligand, namely [pyipy]PF6, and X being Cl and Br. The synthetic pathway is a one-pot reaction that starts from the azolium salt as the NHC source and [Re(CO)5X] to yield the desired charge-neutral fac-[Re(pyipy)(CO)3X] complexes (1-2). Both complexes were thoroughly characterized by spectroscopic, electrochemical, theoretical investigation as well as X-ray diffraction analysis. They display a rather similar electronic absorption spectrum in dilute CH2Cl2 solution, which is characterized by a broad profile extending into the blue region. This lowest-lying absorption band is attributed to a transition with admixed metal-to-ligand charge transfer and intraligand charge transfer (1MLCT/1ILCT) character. Degassed samples of the complexes display moderate (Φ≈ 1.5%) and long-lived (τ = 12.8-13.4 µs) red photoluminescence with highly structured profile independent of the nature of the ancillary halogen ligand and little sensitivity to the solvent polarity, highlighting the markedly different nature of the emitting excited state in comparison with the lowest-lying absorption. Indeed, photoluminescence is ascribed to a long-lived excited state with metal-perturbed triplet ligand-centred (3LC) character as supported by both experimental and density functional theory (DFT) investigations.

16.
Anal Bioanal Chem ; 412(7): 1585-1595, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31982924

RESUMEN

In this paper, a fast method for the detection of irinotecan (CPT-11) in plasma samples was investigated. CPT-11 is widely used in a number of chemotherapeutic treatments of several solid tumors. The method is based on the combination of a solid phase extraction and an electrochemical detection step. The extraction of CPT-11 from plasma was performed using solid phase extraction (SPE) columns and acetonitrile as eluent. The procedure included also a cleaning step to eliminate interference due to plasma endogenous compounds and the co-therapeutics 5-fluoroacil (5-FU) and folinic acid (FA). The latter are administered together with CPT-11 in the FOLFIRI regimen. The detection of CPT-11 was performed by differential pulse voltammetry at a glassy carbon electrode (GCE) in basified acetonitrile media. Under these conditions, a well-defined peak due to the oxidation of the tertiary ammine end of CPT-11, also free from interference due to main metabolites, was obtained. Calibration plots showed a good linear response with limit of detection and quantification of 1.10 × 10-7 and 3.74 × 10-7 M, respectively. The suitability of the method proposed here for clinical applications was verified by determining the concentration of CPT-11 in plasma samples of an oncological patient, collected after 30 and 180 min from the infusion of the drug. Graphical abstract.


Asunto(s)
Técnicas Electroquímicas/métodos , Irinotecán/sangre , Extracción en Fase Sólida/métodos , Inhibidores de Topoisomerasa I/sangre , Humanos
17.
Angew Chem Int Ed Engl ; 58(50): 18202-18206, 2019 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-31603275

RESUMEN

We report the integration of surface plasmon resonance (SPR), cyclic voltammetry and electrochemiluminescence (ECL) responses to survey the interfacial adsorption and energy transfer processes involved in ECL on a plasmonic substrate. It was observed that a Tween 80/tripropylamine nonionic layer formed on the gold electrode of the SPR sensor, while enhancing the ECL emission process, affects the electron transfer process to the luminophore, Ru(bpy)32+ , which in turn has an impact on the plasmon resonance. Concomitantly, the surface plasmon modulated the ECL intensity, which decreased by about 40 %, due to an interaction between the excited state of Ru(bpy)32+ and the plasmon. This occurred only when the plasmon was excited, demonstrating that the optically excited surface plasmon leads to lower plasmon-mediated luminescence and that the plasmon interacts with the excited state of Ru(bpy)32+ within a very thin layer.

18.
J Pharm Biomed Anal ; 159: 73-81, 2018 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-29980022

RESUMEN

The implementation of therapeutic drug monitoring in the routine clinical practice in oncology is mainly limited by the lack of therapeutic indexes for the majority of the anticancer drugs, and by the absence of suitable analytical tools, which can accurately quantify in real time the concentration of the administered drugs and their relevant metabolites in biological fluids. In this work, a simple and efficient fluorimetric determination of SN-38, the active metabolite of the anticancer drug irinotecan, was developed and applied to human plasma samples. The intrinsic fluorescence of SN-38 allowed its quantification in the range 10-500 ng mL-1 with a LOQ of 5.0 ng mL-1 and a LOD of 1.5 ng mL-1. Low interferences due to main metabolites of irinotecan and comedications, commonly associated with administration of irinotecan, were observed. A validation study, according to FDA and EMA guidelines for bioanalytical method validation, was carried out and, finally, blind samples were analyzed in parallel with a HPLC-MS method obtaining an excellent agreement between the two techniques.


Asunto(s)
Antineoplásicos Fitogénicos/sangre , Camptotecina/análogos & derivados , Monitoreo de Drogas/métodos , Fluorometría/métodos , Camptotecina/análisis , Camptotecina/sangre , Monitoreo de Drogas/normas , Fluorometría/normas , Humanos , Irinotecán , Reproducibilidad de los Resultados
19.
Chem Commun (Camb) ; 54(39): 4999-5002, 2018 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-29707706

RESUMEN

Electrochemiluminescence (ECL) generated by a monolayer of a spirobifluorene derivative covalently bound onto an indium tin oxide (ITO) substrate is reported for the first time. Our approach allows the efficient preparation homogeneous and patterned substrates through micromolding in capillaries (MIMIC), and opens novel scenarios for multicolour ECL applications.

20.
Anal Chem ; 90(10): 6012-6019, 2018 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-29658266

RESUMEN

Therapeutic drug monitoring (TDM) is the clinical practice of measuring pharmaceutical drug concentrations in patients' biofluids at designated intervals, thus allowing a close and timely control of their dosage. To date, TDM in oncology can only be performed by trained personnel in centralized laboratories and core facilities employing conventional analytical techniques (e.g., MS). CPT-11 is an antineoplastic drug that inhibits topoisomerase type I, causing cell death, and is widely used in the treatment of colorectal cancer. CPT-11 was also found to directly inhibit acetylcholine esterase (AChE), an enzyme involved in neuromuscular junction. In this work, we describe an enzymatic biosensor, based on AChE and choline oxidase (ChOx), which can quantify CPT-11. ACh (acetylcholine) substrate is converted to choline, which is subsequently metabolized by ChOx to give betaine aldehyde and hydrogen peroxide. The latter one is then oxidized at a suitably polarized platinum electrode, providing a current transient proportional to the amount of ACh. Such an enzymatic process is hampered by CPT-11. The biosensor showed a ∼60% maximal inhibition toward AChE activity in the clinically relevant concentration range 10-10 000 ng/mL of CPT-11 in both simple (phosphate buffer) and complex (fetal bovine serum) matrixes, while its metabolites showed negligible effects. These findings could open new routes toward a real-time TDM in oncology, thus improving the therapeutic treatments and lowering the related costs.


Asunto(s)
Antineoplásicos/análisis , Técnicas Biosensibles , Neoplasias Colorrectales/tratamiento farmacológico , Técnicas Electroquímicas , Irinotecán/análisis , Acetilcolinesterasa , Oxidorreductasas de Alcohol , Antineoplásicos/metabolismo , Antineoplásicos/farmacología , Muerte Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Neoplasias Colorrectales/patología , Relación Dosis-Respuesta a Droga , Ensayos de Selección de Medicamentos Antitumorales , Humanos , Irinotecán/metabolismo , Irinotecán/farmacología , Estructura Molecular , Relación Estructura-Actividad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...