Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
In. Timerman, Ari; Bertolami, Marcelo; Ferreira, João Fernando Monteiro. Manual de Cardiologia. São Paulo, Atheneu, 2012. p.791-802, ilus, graf.
Monografía en Portugués | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1080140
2.
In. Silva, Carlos Eduardo Suaide. Ecocardiografia: princípios e aplicações clínicas. Rio de Janeiro, Revinter, 2 ed; 2012. p.417-443, ilus.
Monografía en Portugués | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1081743
3.
In. Silva, Carlos Eduardo Suaide. Ecocardiografia: princípios e aplicações clínicas. Rio de Janeiro, Revinter, 2 ed; 2012. p.1061-1074, ilus.
Monografía en Portugués | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1081746
4.
Rev. bras. cardiol. invasiva ; 18(01): 74-80, 07/03/2010.
Artículo en Portugués | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1066948

RESUMEN

O forme oval patente ocorre em 27% a 30% da população e pode estar associadoa eventos embólicos, dentre eles o acidente vascular cerebral criptogênico. A prótese PREMERE, especialmente desenvolvida para a correção do forame oval patente, apresenta baixo perfil , reduzida quantidade de metal e âncora no lado esquerdo, com reduzida superfície para minimizar o risco de formação de trombos. Avaliamos os resultados clínicos e ecocardiográficos imediatos e aos três e seis meses pós-implante do dispositivo...


Asunto(s)
Accidente Cerebrovascular , Diseño de Prótesis , Ecocardiografía Transesofágica , Embolia Intracraneal , Foramen Oval Permeable
5.
Rev. bras. cardiol. invasiva ; 18(1): 74-80, mar. 2010. tab, ilus
Artículo en Portugués | LILACS | ID: lil-549234

RESUMEN

INTRODUÇÃO: O forame oval parente ocorre em 27 por cento a 30 por cento da população e pode estar associado a eventos embólicos, dentre eles o acidente vascular cerebral criptogênico. A prótese PREMEREtm. especialmente desenvolvida para a correção do forame oval patente, apresenta baixo perfil, reduzida quantidade de metal e âncora no lado esquerdo, com reduzida superfície para minimizar o risco de formação de trombos. Avaliamos os resultados clínicos e ecocardiográficos imediatos e aos três e seis meses pós-implante do dispositivo. Métodos: Entre maio de 2008 e junho de 2009, a prótese foi implantada em 14 pacientes com forame oval patente e que apresentaram eventos embólicos cerebrais prévios, comprovados por tomografia computadorizada e/ou ressonância nuclear magnética de crânio. O diagnóstico ecocardiográfico de forame oval patente foi realizado quando microbolhas...


BACKGROUND: Patent foramen ovale is observed in 27% to 30% of the population and may be associated to embolic events, among them the cryptogenic stroke. The PREMERE TM device, specially developed to correct patent foramen ovale, has a low profile, reduced amount of metal and a left anchor with a small total surface to minimize the risk of thrombus formation. Clinical and echocardiographic results were evaluated immediately after the procedure and 3 and 6 months after device implantation. METHOD: From May 2008 to June 2009, the device was implanted in 14 patients with patent foramen ovale with prior cerebral embolic events, confirmed by computerized tomography and/or cranial magnetic resonance imaging. Echocardiographic patent foramen ovale was diagnosed when microbubbles were detected in the left atrium within three heartbeats after opacification of the right atrium. Patients with patent foramen ovale with interatrial septal aneurysm > 2 cm, those with atrial fibrilation/flutter or with other diseases that might explain the cryptogenic stroke were excluded. RESULTS: Nine (64.3%) patients were male and mean age was 47.2 ± 17.5 years. Successful implantation was achieved in 100% of the cases. Transesophageal echocardiogram immediately after the procedure showed the presence of microbubbles in the left atrium with Valsalva maneuver in 50% of the cases. All of the patients were discharged the following day, receiving acetyl salicylic acid 200 mg/day and clopidogrel 75 mg/day and returned after 3 months for clinical and echocardiographic follow-up. The transesophageal echocardiogram at three months showed a mild residual flow in only 3 (21.4%) patients. These patients had a totally occluded patent foramen ovale at the 6-month follow-up transesophageal echocardiogram. None of the patients had cardiovascular events during the follow-up period. CONCLUSION: The PREMERE TM device proved to be safe and effective in the occlusion of patent foramen ovale. The occlusion rate in this initial experience was high for a follow-up period of 6 months.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Adulto , Persona de Mediana Edad , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico , Foramen Oval Permeable/cirugía , Diseño de Prótesis , Ecocardiografía/métodos , Ecocardiografía
6.
Rev. bras. cardiol. invasiva ; 16(1): 86-90, jan.-mar. 2008.
Artículo en Portugués | LILACS, Sec. Est. Saúde SP | ID: lil-489317

RESUMEN

Introdução: A oclusão percutânea do canal arterial persistente (PCA) com implante retrógrado não controlado de molas de Gianturco tem sido freqüentemente empregada. Método: Desde janeiro de 2001, temos aplicado essa técnica em pacientes com canais < 3 mm, dos tipos A, D e E, e não tolerado fluxos residuais imediatos significativos, implantando outra mola. Neste artigo, descrevemos os resultados desse tipo de abordagem. Resultados: Desde janeiro de 2001, 178 pacientes (110 do sexo feminino; mediana de idade e peso: cinco anos e 17 kg, respectivamente) foram submetidos ao procedimento. A média do diâmetro mínimo do PCA foi de 1,8 ± 0,6 mm (0,5 mm a 3,0 mm), sendo 157 do tipo A, nove do tipo D e 12 do tipo E. Em três pacientes, houve embolização inicial das molas com resgate, sendo reimplantadas em dois (taxa de sucesso: 99,4%). Mais de uma mola foi utilizada em 32 (18%) pacientes, com canais significativamente maiores que os restantes (2,3 ± 0,5 mm vs. 1,6 ± 0,5 mm; p < 0,001). Oclusão imediata foi observada em 160 pacientes e 17 (9,6%) possuíam fluxo residual discreto, difuso e de baixa velocidade. Redução de pulsos e transfusão foram complicações observadas em dois pacientes. Um paciente com fluxo residual discreto não retornou. Todos os 176 pacientes, à ecocardiografia, apresentavam oclusão e nenhum apresentava distúrbios de fluxo na aorta ou na artéria pulmonar no seguimento (mediana: seis meses). Conclusão: A tolerância zero para fluxos residuais imediatos e a seleção otimizada das molas e dos pacientes, provavelmente, explicam esses ótimos resultados. O procedimento é simples, custo efetivo, seguro e altamente eficaz.


Introduction: Percutaneous occlusion of the patent ductus arteriosus (PDA) by non-controlled retrogade release of Gianturco coils has been frequently employed. Methods: Since January of 2001, we have applied this technique for patients with type A, D and E PDAs with < 3 mm and have not tolerated significant immediate residual leaks, implanting additional coils. In this paper we report the outcome of this approach. Results: From January 2001, 178 patients (110 females; median age and weight: 5 years and 17 kg, respectively) underwent the procedure. The mean minimal diameter of the PDA was 1.8 ± 0.6 mm (0.5 to 3.0 mm) with 157, 9 and 12 being of types A, D and E, respectively. In 3 patients, there was initial embolization with percutaneous retrieval followed by coil re-implantation in 2 (success rate: 99.4%). More than one coil was required in 32 patients with PDAs significantly larger than the remainder (2.3 ± 0.5 versus 1.6 ± 0.5 mm; p < 0.001). Immediate occlusion was observed in 160 patients with 17 (9.6%) having discrete, diffuse, low velocity residual leaks. Pulse reduction and transfusion were complications observed in 2 patients. One patient with mild residual leak was lost to follow up. On echocardiography, all 176 patients had occlusion and none had flow disturbances in the aorta or in the pulmonary artery on follow up (average 6 months). Conclusion: Zero tolerance for significant immediate residual leaks and optimized selection of coils and patients probably explain these excellent outcomes. The procedure is easy to perform, cost effective, safe and highly efficient.


Asunto(s)
Humanos , Masculino , Femenino , Preescolar , Prótesis e Implantes , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco , Conducto Arterioso Permeable/complicaciones , Embolización Terapéutica/métodos , Embolización Terapéutica
7.
Rev. bras. cardiol. invasiva ; 15(4): 386-393, out.-dez. 2007. ilus, tab
Artículo en Portugués | LILACS, Sec. Est. Saúde SP | ID: lil-477838

RESUMEN

Objetivo: O objetivo deste artigo foi descrever a experiência clínica inicial com a utilização do dispositivo Intrasept™ (Cardia, Inc., Burnsville, Minnesota, Estados Unidos) na oclusão percutânea do forame oval patente (FOP). Método: Foram incluídos pacientes com: 1. evento tromboembólico criptogênico prévio; 2. enxaqueca com aura; e 3. FOP com fluxo direita-esquerda à ecocardiografia transesofágica (ETE). A eficácia do dispositivo foi definida pela ausência de fluxo direita-esquerda à ETE com microbolhas e/ou Doppler transcraniano (DTC) após seis meses e ausência de eventos tromboembólicos recorrentes no período de seguimento. O dispositivo foi considerado seguro na ausência de complicações maiores, durante ou após o procedimento. De março de 2006 a junho de 2007, 15 pacientes com FOP foram submetidos ao procedimento de oclusão percutânea com o dispositivo Intrasept™ (8 pacientes do sexo feminino; idade entre 19 e 64 anos, com mediana de 33), dos quais 3 (20%) apresentavam aneurisma do septo atrial (ASA) e 2 (13%) possuíam valva de Eustáquio proeminente (VEP) associada ao FOP. Resultados: Sucesso técnico no implante foi observado em todos os casos. Não foram observadas complicações maiores durante o procedimento. ETE com microbolhas e/ou DTC foram realizados em 11 (73%) pacientes durante o seguimento tardio, e nenhum apresentou fluxo direita-esquerda residual. Após 9,2 ± 5,8 meses de seguimento total, nenhum paciente apresentou evento tromboembólico recorrente e 2 dos 3 pacientes com enxaqueca apresentaram redução da freqüência e da intensidade das crises. Conclusão: O uso do dispositivo Cardia Intrasept™ para oclusão percutânea de FOP, nesta experiência inicial, foi exeqüível, de simples realização técnica, seguro e eficaz, constituindo-se em nova alternativa no armamentário do intervencionista.


Objective: The purpose of this study was to report the initial experience with the IntraseptTM device (CARDIA, Inc., Burnsville, MN, USA) for percutaneous PFO closure. Methods: Patients with 1. previous cryptogenic thromboembolic event and/or 2. migraine with aura symptoms associated with 3. transesophageal echocardiographic (TEE)evidence of a PFO with right-to-left shunt were included. The device’s efficacy was defined as the absence of rightto-left shunt assessed by TEE and/or transcranial Doppler (TCD) 6 months after the procedure and no evidence of recurrent thromboembolic events during follow-up. The device was considered safe in the absence of peri or post procedural major complications. Since March 2006 until June 2007, 15 patients underwent percutaneous PFO closure with the IntraseptTM device (8 female; age 19 to 64 years, median of 33). Association with an atrial septal aneurysm (ASA) and prominent Eustachian valve was seen in 3 (20%) and 2 (13%) patients, respectively. Results: Implantation of the occluder was technically successful in all patients. No major complications occurred. Eleven patients (73%) were submitted to TEE and/or TCD during late follow-up and no residual shunt was observed. During a mean total follow-up period of 9.2 ± 5.8 months, no recurrent thromboembolic event occurred and 2 of the 3 patients with migraine had improvement in the frequency and severity of migraine symptoms. Conclusion: In this initial experience, percutaneous occlusion of oval patent foramen with the IntraseptTM device was technically simple, safe and effective, constituting a new alternative for the interventionist.


Asunto(s)
Humanos , Femenino , Adulto , Persona de Mediana Edad , Cateterismo Cardíaco , Defectos del Tabique Interatrial , Prótesis e Implantes , Experimentación Humana , Estudios de Seguimiento
8.
In. Meneghelo, Zilda; Ramos, Auristela Isabel de Oliveira; Meneghelo, Zilda. Instituto Dante Pazzanese de Cardiologia. BrasilRamos, Auristela Isabel de Oliveira. Instituto Dante Pazzanese de Cardiologia. Brasil. Lesões das Valvas Cardícas do Diagnóstico ao Tratamento. São Paulo, Atheneu, 2007. p.69-107, ilus.
Monografía en Portugués | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1069849

RESUMEN

As doenças valvares e suas implicações clínicas permanecem, nos dias atuais,um desafio para a prática médica. Apesar dos grandes avanços nas técnicas diagnósticas por imagem, a análise quantitativa da gravidade das lesões valvares ainda é motivo de controvérsia e de difícil uniformização. Com suas diversas modalidades, é o método de escolha na avaliação das doenças valvares, devido ao baixo custo e à facil realização. A ecocardiografia uni e bidimensional permite o estudo da geometria espacial do coração e a interrelação anatômica entre as diversas estruturas intra e extracardíacas, a avaliação do tamanho das cavidades e função ventricular, presença de trombos intracavitários, fornecendo informações importantes para o manejo correto dos portadores de doença valvar...


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Ecocardiografía , Ecocardiografía Doppler , Técnicas de Diagnóstico Cardiovascular
9.
In. Ghorayeb, Nabil; Dioguardi, Giuseppe S. Tratado de Cardiologia do exercício e do esporte. São Paulo, Atheneu, 2007. p.223-236.
Monografía en Portugués | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1070944
10.
Vascular ; 14(3): 149-55, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16956487

RESUMEN

The objective of this study was to evaluate the existence of hemodynamic arterial flow correlation between preoperative duplex scanning (DS) and intraoperative direct outflow resistance (IDOR) measurements in ischemic lower limb revascularization. Sixty-eight ischemic lower limbs were submitted to preoperative DS. Anatomic and hemodynamic arterial characteristics of the outflow system were recorded, and the results were considered in the distal anastomosis placement site decision making. IDOR measurements were obtained at the same arterial segment, and Pearson's correlation coefficient test was performed to study the preoperative DS power in predicting the intraoperative outflow resistance. DS was technically satisfactory and helped define the distal anastomosis site in 93.2% of the cases (supragenicular popliteal artery, 19 [27.9%]; infragenicular popliteal artery, 10 [14.7%]; crural artery, 31 [57.4%]). A positive correlation could be found between preoperative DS and IDOR (0.450; p < .001). This correlation was particularly powerful in the crural artery (0.715; p < .001) when compared with the popliteal arterial segment (0.237; p = .192). Preoperative DS may help define the best distal arterial and outflow segment to be revascularized based on anatomic and hemodynamic parameters. There is a positive flow correlation between preoperative DS and IDOR that seems to be stronger in crural revascularization surgery.


Asunto(s)
Implantación de Prótesis Vascular/métodos , Isquemia/cirugía , Pierna/irrigación sanguínea , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Toma de Decisiones , Femenino , Humanos , Cuidados Intraoperatorios/métodos , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Cuidados Preoperatorios/métodos , Ultrasonografía Doppler en Color , Resistencia Vascular
14.
Arq. bras. cardiol ; 83(n.spe): 64-70, dez. 2004. ilus, tab
Artículo en Portugués | LILACS, Sec. Est. Saúde SP | ID: lil-390725

RESUMEN

OBJETIVO: Identificar variáveis Doppler-ecocardiográficas associadas ao tipo de cirurgia realizada na regurgitação mitral reumática e determinar a relação entre essas variáveis e resultados da plastia em médio prazo. MÉTODOS: Analisaram-se variáveis Doppler-ecocardiográficas em 68 pacientes com regurgitação mitral reumática grave no dia prévio à cirurgia, que foram divididos, segundo a cirurgia realizada, em grupo-plastia e grupo-troca. Grupo-plastia submeteu-se também a Doppler-ecocardiograma antes da alta hospitalar e seis meses após. Compararam-se variáveis Doppler-ecocardiográficas do exame pré-operatório ao tipo de cirurgia e grau de regurgitação detectado seis meses após. RESULTADOS: Os grupos foram iguais nas características demográficas e função ventricular. O grupo-troca apresentou área mitral menor (p = 0.001). Na análise univariada as variáveis associadas à troca foram restrição da mobilidade dos folhetos anterior (p = 0.01) e posterior (p = 0.01), calcificação do folheto anterior (p = 0.01) e fusão de cordoalha (p = 0.018). Restrição da mobilidade do folheto anterior e área permaneceram como determinantes independentes de implante protético pós-análise multivariada. Dos 7 pacientes com regurgitação mitral maior que discreta, detectada 6 meses após plastia, 6 mostraram antes da cirurgia restrição da mobilidade do folheto anterior e 4, fusão de cordoalha. CONCLUSÃO: Probabilidade de troca valvar é 3,8 vezes maior quando presente restrição da mobilidade do folheto anterior da valva mitral e 2,2 vezes maior para cada 0,5 cm² de redução da área mitral. Restrição da mobilidade do folheto anterior e fusão de cordoalha estão associadas à regurgitação maior que discreta, observada 6 meses após plastia.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Ecocardiografía Doppler/métodos , Insuficiencia de la Válvula Mitral/cirugía , Cardiopatía Reumática/complicaciones , Métodos Epidemiológicos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral , Resultado del Tratamiento
15.
Arq. bras. cardiol ; 83(n.spe): 34-42, dez. 2004. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-390720

RESUMEN

OBJETIVO: Determinar a incidência de fístulas arteriovenosas pulmonares (FAVPs) pós-operação de Glenn bidirecional; as possíveis variáveis independentes que poderiam influenciar no seu aparecimento; comprovar o uso do ecocardiograma contrastado com microbolhas na sua detecção; e testar a sensibilidade e especificidade da angiografia pulmonar. MÉTODOS: Operados 59 pacientes, entre março 1990 e dezembro 1995, com idades entre 2 e 132 meses (média 32,7±33,6). Todos submetidos a exames clínico, laboratorial, ecocardiograma contrastado com microbolhas e cateterismo cardíaco. RESULTADOS: Nos 54 pacientes sobreviventes as FAVPs ocorreram em 20 (37,0 por cento). A idade desses pacientes variou de 2 a 132 meses (média 29,6± 29,7). A atresia tricúspide em 10 (50,0 por cento) e o coração univentricular em 8 (40,0 por cento), foram as cardiopatias prevalentes. Em 13 (65 por cento) a operação de Glenn bidirecional foi realizada à direita, em 2 (10, por cento), à esquerda e em 5 (25 por cento) foi bicaval. O tempo de seguimento dos pacientes FAVPs, variou de 4 a 84 meses (média 32,4±21,65), e nos sem fístulas de 1 a 77 meses (média de 23,4±18,8), com valor de p=0,04, com significância estatística. O diagnóstico de FAVPs foi feito pelo ecocardiograma contrastado com microbolhas nos 20 casos, sendo considerado positivo, ao se detectar retorno de microbolhas pelas veias pulmonares. A angiografia pulmonar mostrou alterações compatíveis com FAVPs em 16, demonstrando sensibilidade de 80 por cento. CONCLUSÃO: A incidência de FAVPs pós-operação de Glenn bidirecional foi alta (37 por cento), e o intervalo de tempo decorrido após a operação de Glenn bidirecional, foi a única variável independente que se correlacionou de forma significativa com o aparecimento das FAVPs (p=0,04); o ecocardiograma com microbolhas foi o método padrão de diagnóstico; a angiografia pulmonar se revelou um método com sensibilidade de 80,0 por cento.


Asunto(s)
Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Fístula Arteriovenosa/etiología , Derivación Arteriovenosa Quirúrgica/efectos adversos , Cardiopatías Congénitas/cirugía , Arteria Pulmonar/anomalías , Venas Pulmonares/anomalías , Fístula Arteriovenosa/diagnóstico , Fístula Arteriovenosa/cirugía , Ecocardiografía/métodos , Estudios de Seguimiento , Incidencia , Arteria Pulmonar/cirugía , Venas Pulmonares/cirugía , Sensibilidad y Especificidad
16.
J Am Coll Cardiol ; 43(1): 77-84, 2004 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-14715187

RESUMEN

OBJECTIVES: The goal of this study was to evaluate whether quantitation of thrombus burden with transesophageal echocardiography (TEE) can help risk-stratify patients undergoing thrombolysis of prosthetic valve thrombosis (PVT). BACKGROUND: Thrombolytic therapy of PVT has an unpredictable risk of embolization and complications. METHODS: An international registry of patients with suspected PVT undergoing two-dimensional/Doppler and TEE before thrombolysis was established. All TEE studies were reviewed and quantitated by a single observer blinded to all data. RESULTS: From 1985 to 2001, 107 patients (71 females; age 24 to 86 years) from 14 centers (6 in the U.S.) were identified. The majority of cases involved the mitral valve (79 mitral, 13 aortic, and 15 tricuspid). Hemodynamic success rate was achieved in 85% and was similar across valves. Overall complications were observed in 17.8%, and death in 5.6%. Predictors of complications were: New York Heart Association (NYHA) functional class, presence of shock, sinus tachycardia, hypotension, previous history of stroke, thrombus extension beyond the valve ring, and thrombus area. Multivariate analysis demonstrated that two variables were independent predictors of complications: thrombus area by TEE (odds ratio [OR] 2.41 per 1 cm2 increment, 95% confidence interval [CI] 1.12 to 5.19) and prior history of stroke (OR 4.55, 95% CI 1.35 to 15.38). A thrombus area <0.8 cm2 identified patients at lower risk for complications from thrombolysis, irrespective of NYHA functional class. CONCLUSIONS: In PVT, the thrombus size imaged with TEE is a significant independent predictor of outcome. Transesophageal echocardiography can identify low-risk groups for thrombolysis irrespective of symptom severity and is therefore recommended in the management of prosthetic valve thrombosis.


Asunto(s)
Ecocardiografía Transesofágica , Prótesis Valvulares Cardíacas/efectos adversos , Terapia Trombolítica , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sistema de Registros , Medición de Riesgo , Terapia Trombolítica/efectos adversos , Trombosis/etiología
17.
J. Am. Coll. Cardiol ; 43(1): 77-784, 07012004. ilus
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063723

RESUMEN

The goal of this study was to evaluate whether antitation of thrombus burden with transesophageal echocardiography (TEE) can help risk-stratify patients undergoing thrombolysis of prosthetic valve thrombosis (PVT). BACKGROUND: Thrombolytic therapy of PVT has an unpredictable risk of embolization and complications. METHODS: An international registry of patients with suspected PVT undergoing two-dimensional/Doppler and TEE before thrombolysis was established. All TEE studies were reviewed and quantitated by a single observer blinded to all data. RESULTS: From 1985 to 2001, 107 patients (71 females; age 24 to 86 years) from 14 centers (6 in the U.S.) were identified. The majority of cases involved the mitral valve (79 mitral, 13 aortic, and 15 tricuspid). Hemodynamic success rate was achieved in 85% and was similar across valves. Overall complications were observed in 17.8%, and death in 5.6%.Predictors of complications were: New York Heart Association (NYHA) functional class, presence of shock, sinus tachycardia, hypotension,previous history of stroke, thrombus extension beyond the valve ring, and thrombus area. Multivariate analysis demonstrated that two variables were independent predictors of complications: thrombus area by TEE (odds ratio [OR] 2.41 per 1 cm2 increment, 95% confidence interval [CI] 1.12 to 5.19)and prior history of stroke (OR 4.55, 95% CI 1.35 to 15.38). A thrombus area <0.8 cm2 identified patients at lower risk for complications from thrombolysis, irrespective of NYHA functional class...


Asunto(s)
Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Humanos , Ecocardiografía , Prótesis Valvulares Cardíacas , Terapia Trombolítica , Trombosis
18.
Arq. bras. cardiol ; 81(5): 435-452, nov. 2003. ilus, tab
Artículo en Inglés, Portugués | LILACS, Sec. Est. Saúde SP | ID: lil-351136

RESUMEN

OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 ± 3.3mm, and 15.2 ± 3.8mm, respectively. The Qp/Qs ratio was 1.9 ± 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety


Asunto(s)
Humanos , Preescolar , Niño , Adolescente , Adulto , Cateterismo Cardíaco/instrumentación , Defectos del Tabique Interatrial/terapia , Prótesis e Implantes , Análisis de Varianza , Angiocardiografía , Brasil , Fluoroscopía , Estudios de Seguimiento , Atrios Cardíacos , Cateterismo Cardíaco/métodos , Defectos del Tabique Interatrial
20.
In. Santana, Maria Virgínia Tavares. Cardiopatias congênitas no recém-nascido. São Paulo, Atheneu, 2000. p.38-49, ilus.
Monografía en Portugués | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1069583
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA