Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sarcoidosis Vasc Diffuse Lung Dis ; 32(1): 32-6, 2015 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-26237353

RESUMEN

Recent ATS/ERS/JRS/ALAT guidelines for the diagnosis and management of Idiopathic Pulmonary Fibrosis (IPF) have defined key features and specific high-resolution computerized tomography (HRCT) patterns for the diagnosis of UIP. The aim is the sorting of patients with suspected IPF into three subgroups, confident, possible or inconsistent with UIP patterns, after a multidisciplinary discussion (MDD). Specialists in respiratory diseases, radiologists and pathologists should reach IPF diagnosis based on either patients' clinical, radiological and laboratory data, either submitting patients to surgical biopsy. After ATS/ERS/JRS/ALAT recommendations have been applied, it has been identified a subgroup of patients showing uniform apical-basal distribution of honeycombing and reticular abnormalities that could not be categorized as confident, or possible nor inconsistent with UIP. These patients were subsequently diagnosed with IPF after MDD and lung biopsy. Inclusion of this pattern in the recommendation for IPF diagnosis would be worth considering.


Asunto(s)
Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Comunicación Interdisciplinaria , Guías de Práctica Clínica como Asunto , Tomografía Computarizada por Rayos X/métodos , Anciano , Líquido del Lavado Bronquioalveolar/citología , Broncoscopía/métodos , Estudios de Cohortes , Femenino , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Sensibilidad y Especificidad
2.
Respir Med ; 107(12): 2014-21, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24161677

RESUMEN

INTRODUCTION: Ambulatory oxygen (O2) is prescribed to interstitial lung disease (ILD) patients with mild hypoxemia, breathlessness and dyspnea on exertion. Oxygen titration is generally done with the 6 minute walk test (6MWT) to determine the O2 flow preventing oxygen saturation by pulse oximetry (SpO2) from falling below 88%. His study was designed to generate a 6MWT index predicting the O2 flow allowing completion of the 6MWT without oxygen desaturation. METHODS: Oxygen titration data from a group of 66 ILD patients and 30 controls, were used to generate the algorithm determining an index (O2-GAP) predicting oxygen flow required to complete a 6MWT without desaturation below 88%. This index was validated in a group of 93 ILD patients. RESULTS: The O2-GAP index, as obtained from the derivation population, (r(2) = 0.97, p < 0.001) was shown to correctly predict the oxygen flow required to complete the 6MWT without SpO2 falling below 88% validated in the validation population (r(2) = 0.842; p < 0.001). CONCLUSIONS: The O2-GAP index appears to be a useful tool to titrate ambulatory O2 with a single 6MWT on room air in ILD patients with breathlessness and dyspnea on exertion.


Asunto(s)
Prueba de Esfuerzo/métodos , Ejercicio Físico/fisiología , Oxígeno/sangre , Anciano , Algoritmos , Análisis de Varianza , Estudios de Casos y Controles , Disnea/sangre , Disnea/etiología , Disnea/fisiopatología , Femenino , Humanos , Masculino , Oximetría , Estudios Prospectivos , Pruebas de Función Respiratoria , Caminata/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA