Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Mol Diagn ; 24(4): 320-336, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35121140

RESUMEN

Previous studies have described reverse-transcription loop-mediated isothermal amplification (RT-LAMP) for the rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal/oropharyngeal swab and saliva samples. This multisite clinical evaluation describes the validation of an improved sample preparation method for extraction-free RT-LAMP and reports clinical performance of four RT-LAMP assay formats for SARS-CoV-2 detection. Direct RT-LAMP was performed on 559 swabs and 86,760 saliva samples and RNA RT-LAMP on extracted RNA from 12,619 swabs and 12,521 saliva samples from asymptomatic and symptomatic individuals across health care and community settings. For direct RT-LAMP, overall diagnostic sensitivity (DSe) was 70.35% (95% CI, 63.48%-76.60%) on swabs and 84.62% (95% CI, 79.50%-88.88%) on saliva, with diagnostic specificity of 100% (95% CI, 98.98%-100.00%) on swabs and 100% (95% CI, 99.72%-100.00%) on saliva, compared with quantitative RT-PCR (RT-qPCR); analyzing samples with RT-qPCR ORF1ab CT values of ≤25 and ≤33, DSe values were 100% (95% CI, 96.34%-100%) and 77.78% (95% CI, 70.99%-83.62%) for swabs, and 99.01% (95% CI, 94.61%-99.97%) and 87.61% (95% CI, 82.69%-91.54%) for saliva, respectively. For RNA RT-LAMP, overall DSe and diagnostic specificity were 96.06% (95% CI, 92.88%-98.12%) and 99.99% (95% CI, 99.95%-100%) for swabs, and 80.65% (95% CI, 73.54%-86.54%) and 99.99% (95% CI, 99.95%-100%) for saliva, respectively. These findings demonstrate that RT-LAMP is applicable to a variety of use cases, including frequent, interval-based direct RT-LAMP of saliva from asymptomatic individuals who may otherwise be missed using symptomatic testing alone.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/análisis , ARN Viral/genética , SARS-CoV-2/genética , Saliva , Sensibilidad y Especificidad
2.
Clin Microbiol Infect ; 27(9): 1348.e1-1348.e7, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33901668

RESUMEN

OBJECTIVES: Rapid, high throughput diagnostics are a valuable tool, allowing the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in populations so as to identify and isolate people with asymptomatic and symptomatic infections. Reagent shortages and restricted access to high throughput testing solutions have limited the effectiveness of conventional assays such as quantitative RT-PCR (RT-qPCR), particularly throughout the first months of the coronavirus disease 2019 pandemic. We investigated the use of LamPORE, where loop-mediated isothermal amplification (LAMP) is coupled to nanopore sequencing technology, for the detection of SARS-CoV-2 in symptomatic and asymptomatic populations. METHODS: In an asymptomatic prospective cohort, for 3 weeks in September 2020, health-care workers across four sites (Birmingham, Southampton, Basingstoke and Manchester) self-swabbed with nasopharyngeal swabs weekly and supplied a saliva specimen daily. These samples were tested for SARS-CoV-2 RNA using the Oxford Nanopore LamPORE system and a reference RT-qPCR assay on extracted sample RNA. A second retrospective cohort of 848 patients with influenza-like illness from March 2020 to June 2020 were similarly tested from nasopharyngeal swabs. RESULTS: In the asymptomatic cohort a total of 1200 participants supplied 23 427 samples (3966 swab, 19 461 saliva) over a 3-week period. The incidence of SARS-CoV-2 detection using LamPORE was 0.95%. Diagnostic sensitivity and specificity of LamPORE was >99.5% (decreasing to approximately 98% when clustered estimation was used) in both swab and saliva asymptomatic samples when compared with the reference RT-qPCR test. In the retrospective symptomatic cohort, the incidence was 13.4% and the sensitivity and specificity were 100%. CONCLUSIONS: LamPORE is a highly accurate methodology for the detection of SARS-CoV-2 in both symptomatic and asymptomatic population settings and can be used as an alternative to RT-qPCR.


Asunto(s)
COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Pandemias , SARS-CoV-2/aislamiento & purificación , COVID-19/virología , Estudios de Cohortes , Proteínas de la Nucleocápside de Coronavirus/genética , Humanos , Límite de Detección , Secuenciación de Nanoporos , Nasofaringe/virología , Poliproteínas/genética , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos , SARS-CoV-2/genética , Saliva/virología , Sensibilidad y Especificidad , Proteínas Virales/genética
3.
Crit Care Resusc ; 11(2): 122-8, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19485876

RESUMEN

OBJECTIVE: Despite government encouragement for patients to make advance plans for medical treatment, and the increasing numbers of patients who have done this, there is little research that examines how doctors regard these plans. DESIGN: We surveyed Australian intensive care doctors, using a hypothetical clinical scenario, to evaluate how potential end-of-life treatment decisions might be influenced by advance planning - the appointment of a medical enduring power of attorney (MEPA) or an advance care plan (ACP). Using open-ended questions we sought to explore the reasoning behind the doctors' decisions. RESULTS: 275 surveys were returned (18.3% response rate). We found that opinions expressed by an MEPA and ACP have some influence on treatment decisions, but that intensive care doctors had major reservations. Most did not follow the request for palliation made by the MEPA in the hypothetical scenario. CONCLUSIONS: Many intensive care doctors believe end-oflife decisions remain medical decisions, and MEPAs and ACPs need only be respected when they accord with the doctor's treatment decision. This study suggests a need for further education of doctors, particularly those working in intensive care, who are responsible for initiating and maintaining life support treatment.


Asunto(s)
Directivas Anticipadas , Cuidados Críticos , Toma de Decisiones , Pautas de la Práctica en Medicina , Actitud del Personal de Salud , Australia , Humanos , Cuidados Paliativos , Encuestas y Cuestionarios
4.
J Law Med ; 13(2): 256-70, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16304765

RESUMEN

With advances in medical technology, it is now possible to sustain the life of a person in a persistent vegetative state (PVS) until a decision is made to withhold or withdraw life-sustaining treatment. Who makes that decision? Under the Medical Treatment Act 1988 (Vic) there is no legally enforceable right for a person to choose, in advance, what intervention that person will and will not accept if he or she ends up in a PVS. The best that can be achieved is that a person can appoint an agent who is empowered to refuse medical treatment on the person's behalf in the event of incompetence. It is suggested that this mechanism ignores two fundamental human rights: self-determination and the inherent right to dignity. This article proposes the development of an advance directive mechanism that provides for a person to refuse, in advance, specified intervention, thereby respecting fundamental human rights and alleviating the existing need for an agent to second-guess a person's desires and best interests.


Asunto(s)
Directivas Anticipadas/legislación & jurisprudencia , Derechos Civiles/legislación & jurisprudencia , Toma de Decisiones , Cuidados para Prolongación de la Vida/legislación & jurisprudencia , Estado Vegetativo Persistente/diagnóstico , Autonomía Personal , Derecho a Morir/legislación & jurisprudencia , Humanos , Tutores Legales/legislación & jurisprudencia , Victoria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...