Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Neural Eng ; 17(2): 026036, 2020 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-32217819

RESUMEN

OBJECTIVE: The analysis of interactions among local populations of neurons in the cerebral cortex (e.g. within cortical microcolumns) requires high resolution and high channel count recordings from chronically implanted laminar microelectrode arrays. The request for high-density recordings of a large number of recording sites can presently only be accomplished by probes realized using complementary metal-oxide-semiconductor (CMOS) technology. In preparation for their use in non-human primates, we aimed for neural probe validation in a head-fixed approach analyzing the long-term recording capability. APPROACH: We examined chronically implanted silicon-based laminar probes, realized using a CMOS technology in combination with micromachining, to record from the primary visual cortex (V1) of a monkey. We used a passive CMOS probe that had 128 electrodes arranged at a pitch of 22.5 µm in four columns and 32 rows on a slender shank. In order to validate the performance of a dedicated microdrive, the overall dimensions of probe and interface boards were chosen to be compatible with the final active CMOS probe comprising integrated circuitry. MAIN RESULTS: Using the passive probe, we recorded simultaneously local field potentials (LFP) and spiking multiunit activity (MUA) in V1 of an awake behaving macaque monkey. We found that an insertion through the dura and subsequent readjustments of the chronically implanted neural probe was possible and allowed us to record stable LFPs for more than five months. The quality of MUA degraded within the first month but remained sufficiently high to permit mapping of receptive fields during the full recording period. SIGNIFICANCE: We conclude that the passive silicon probe enables semi-chronic recordings of high quality of LFP and MUA for a time span exceeding five months. The new microdrive compatible with a commercial recording chamber successfully demonstrated the readjustment of the probe position while the implemented plug structure effectively reduced brain tissue movement relative to the probe.


Asunto(s)
Macaca , Silicio , Animales , Electrodos Implantados , Fenómenos Electrofisiológicos , Microelectrodos , Neuronas
2.
Front Neurosci ; 13: 464, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31164800

RESUMEN

Throughout the past decade, silicon-based neural probes have become a driving force in neural engineering. Such probes comprise sophisticated, integrated CMOS electronics which provide a large number of recording sites along slender probe shanks. Using such neural probes in a chronic setting often requires them to be mechanically anchored with respect to the skull. However, any relative motion between brain and implant causes recording instabilities and tissue responses such as glial scarring, thereby shielding recordable neurons from the recording sites integrated on the probe and thus decreasing the signal quality. In the current work, we present a comparison of results obtained using mechanically fixed and floating silicon neural probes chronically implanted into the cortex of a non-human primate. We demonstrate that the neural signal quality estimated by the quality of the spiking and local field potential (LFP) recordings over time is initially superior for the floating probe compared to the fixed device. Nonetheless, the skull-fixed probe also allowed long-term recording of multi-unit activity (MUA) and low frequency signals over several months, especially once pulsations of the brain were properly controlled.

3.
Micromachines (Basel) ; 9(9)2018 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-30424357

RESUMEN

The development of innovative tools for neuroscientific research is based on in vivo tests typically applied to small animals. Most often, the interfacing of neural probes relies on commercially available connector systems which are difficult to handle during connection, particularly when freely behaving animals are involved. Furthermore, the connectors often exert high mechanical forces during plugging and unplugging, potentially damaging the fragile bone structure. In order to facilitate connector usage and increase the safety of laboratory animals, we developed a new magnetic connector system circumventing the drawbacks of existing tools. The connector system uses multiple magnet pairs and spring-suspended electrical contact pads realized using micro-electromechanical systems (MEMS) technologies. While the contact pad suspension increases the system tolerance in view of geometrical variations, we achieved a reliable self-alignment of the connector parts at ±50 µm provided by the specifically oriented magnet pairs and without the need of alignment pins. While connection forces are negligible, we can adjust the forces during connector release by modifying the magnet distance. With the connector test structures developed here, we achieved an electrical connection yield of 100%. Based on these findings, we expect that in vivo experiments with freely behaving animals will be facilitated with improved animal safety.

4.
Biomed Tech (Berl) ; 63(3): 301-315, 2018 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-29478038

RESUMEN

Stereo-electroencephalography depth electrodes, regularly implanted into drug-resistant patients with focal epilepsy to localize the epileptic focus, have a low channel count (6-12 macro- or microelectrodes), limited spatial resolution (0.5-1 cm) and large contact area of the recording sites (~mm2). Thus, they are not suited for high-density local field potential and multiunit recordings. In this paper, we evaluated the long-term electrophysiological recording performance and histocompatibility of a neural interface consisting of 32 microelectrodes providing a physical shape similar to clinical devices. The cylindrically-shaped depth probes made of polyimide (PI) were chronically implanted for 13 weeks into the brain of rats, while cortical or thalamic activity (local field potentials, single-unit and multi-unit activity) was recorded regularly to monitor the temporal change of several features of the electrophysiological performance. To examine the tissue reaction around the probe, neuron-selective and astroglia-selective immunostaining methods were applied. Stable single-unit and multi-unit activity were recorded for several weeks with the implanted depth probes and a weak or moderate tissue reaction was found around the probe track. Our data on biocompatibility presented here and in vivo experiments in non-human primates provide a strong indication that this type of neural probe can be applied in stereo-electroencephalography recordings of up to 2 weeks in humans targeting the localization of epileptic foci providing an increased spatial resolution and the ability to monitor local field potentials and neuronal spiking activity.


Asunto(s)
Encéfalo/fisiología , Electroencefalografía/métodos , Neuronas/fisiología , Polímeros/química , Animales , Materiales Biocompatibles , Humanos , Microelectrodos , Ratas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...