Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Sci Rep ; 12(1): 992, 2022 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-35046423

RESUMEN

This study reports the development of prototype swept-source optical coherence tomography (SS-OCT) technology for imaging the anterior eye. Advances in vertical-cavity surface-emitting laser (VCSEL) light sources, signal processing, optics and mechanical designs, enable a unique combination of high speed, long range, and deep penetration that addresses the challenges of anterior eye imaging. We demonstrate SS-OCT with a 325 kHz A-scan rate, 12.2 µm axial resolution (in air), and 15.5 mm depth range (in air) at 1310 nm wavelength. The ultrahigh 325 kHz A-scan rate not only facilitates biometry measurements by minimizing acquisition time and thus reducing motion, but also enables volumetric OCT for comprehensive structural analysis and OCT angiography (OCTA) for visualizing vasculature. The 15.5 mm (~ 11.6 mm in tissue) depth range spans all optical surfaces from the anterior cornea to the posterior lens capsule. The 1310 nm wavelength range enables structural OCT and OCTA deep in the sclera and through the iris. Achieving high speed and long range requires linearizing the VCSEL wavenumber sweep to efficiently utilize analog-to-digital conversion bandwidth. Dual channel recording of the OCT and calibration interferometer fringe signals, as well as sweep to sweep wavenumber compensation, is used to achieve invariant 12.2 µm (~ 9.1 µm in tissue) axial resolution and optimum point spread function throughout the depth range. Dynamic focusing using a tunable liquid lens extends the effective depth of field while preserving the lateral resolution. Improved optical and mechanical design, including parallax "split view" iris cameras and stable, ergonomic patient interface, facilitates accurate instrument positioning, reduces patient motion, and leads to improved imaging data yield and measurement accuracy. We present structural and angiographic OCT images of the anterior eye, demonstrating the unique imaging capabilities using representative scanning protocols which may be relevant to future research and clinical applications.


Asunto(s)
Segmento Anterior del Ojo/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Angiografía/métodos , Segmento Anterior del Ojo/irrigación sanguínea , Biometría/métodos , Humanos , Tomografía de Coherencia Óptica/instrumentación
2.
Biomed Opt Express ; 12(4): 2384-2403, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-33996236

RESUMEN

Swept source optical coherence tomography (SS-OCT) enables volumetric imaging of subsurface structure. However, applications requiring wide fields of view (FOV), rapid imaging, and higher resolutions have been challenging because multi-MHz axial scan (A-scan) rates are needed. We describe a microelectromechanical systems vertical cavity surface-emitting laser (MEMS-VCSEL) SS-OCT technology for A-scan rates of 2.4 and 3.0 MHz. Sweep to sweep calibration and resampling are performed using dual channel acquisition of the OCT signal and a Mach Zehnder interferometer signal, overcoming inherent optical clock limitations and enabling higher performance. We demonstrate ultrahigh speed structural SS-OCT and OCT angiography (OCTA) imaging of the swine gastrointestinal tract using a suite of miniaturized brushless motor probes, including a 3.2 mm diameter micromotor OCT catheter, a 12 mm diameter tethered OCT capsule, and a 12 mm diameter widefield OCTA probe. MEMS-VCSELs promise to enable ultrahigh speed SS-OCT with a scalable, low cost, and manufacturable technology, suitable for a diverse range of imaging applications.

3.
Artículo en Inglés | MEDLINE | ID: mdl-32883714

RESUMEN

OBJECTIVE: Barrett's oesophagus (BE) screening outside the endoscopy suite can identify patients for surveillance and reduce mortality. Tethered capsule optical coherence tomography (OCT) can volumetrically image oesophageal mucosa in unsedated patients and detect features of BE. We investigated ultrahigh-speed tethered capsule swept-source OCT (SS-OCT), improved device design, developed procedural techniques and measured capsule contact, longitudinal pullback non-uniformity and patient toleration. DESIGN: OCT was performed in 16 patients prior to endoscopic surveillance/treatment. Unsedated patients swallowed the capsule with sips of water and the tether was pulled back to image the oesophagus. SS-OCT at 1 000 000 A-scans/s enabled imaging 10 cm oesophageal lengths in 10 s with 30 µm transverse and 8 µm axial resolution. Capsule contact, longitudinal image coverage and patient toleration were assessed. RESULTS: Nine patients had non-dysplastic BE, three had ablative treatment-naïve neoplasia and four had prior ablation for dysplasia. Dry swallows facilitated capsule transit through the lower oesophageal sphincter (LES), and waiting 10 s before pullback reduced swallow induced LES relaxation. Slow nasal inhalation facilitated capsule retrieval and minimised gag reflex. The procedure was well tolerated. Ultrahigh-speed SS-OCT generated cross-sectional and subsurface en face images showing BE features, while subsurface en face images were required to assess the gastro-oesophageal junction. Candidate features of dysplasia were also identified which could inform follow-up endoscopy/biopsy. BE features were seen in all patients with histologically confirmed BE. Mean capsule contact over BE was 75%±27% for all patients and better in short segment BE. Mean longitudinal image coverage over BE was 59%±34% and better for long segment BE. CONCLUSIONS: Ultrahigh-speed tethered capsule SS-OCT can image en face and cross-sectional mucosal features over wide areas. Device and procedure optimisation improved performance. BE features could be identified in all patients, but limited capsule contact and longitudinal coverage could cause sampling errors for focal pathologies.


Asunto(s)
Esófago de Barrett/diagnóstico por imagen , Endoscopía Capsular/métodos , Mucosa Esofágica/patología , Tomografía de Coherencia Óptica/instrumentación , Anciano , Esófago de Barrett/patología , Esófago de Barrett/cirugía , Biopsia/métodos , Endoscopía Capsular/efectos adversos , Sedación Consciente/efectos adversos , Deglución/fisiología , Diseño de Equipo/tendencias , Unión Esofagogástrica/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
Endoscopy ; 51(4): 355-359, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30261534

RESUMEN

BACKGROUND: This study aimed to evaluate the use of ultrahigh-speed volumetric en face and cross-sectional optical coherence tomography (OCT) with micromotor catheters for the in vivo assessment of Barrett's esophagus and dysplasia. METHODS: 74 OCT datasets with correlated biopsy/endoscopic mucosal resection histology (49 nondysplastic Barrett's esophagus [NDBE], 25 neoplasia) were obtained from 14 patients with Barrett's esophagus and a history of dysplasia and 30 with NDBE. The associations between irregular mucosal patterns on en face OCT, absence of mucosal layering, surface signal > subsurface, and > 5 atypical glands on cross-sectional OCT vs. histology and treatment history were assessed by three blinded readers. RESULTS: Atypical glands under irregular mucosal patterns occurred in 75 % of neoplasia (96 % of treatment-naïve neoplasia) vs. 30 % of NDBE datasets (43 % of short- and 18 % of long-segment NDBE). Mucosal layering was absent in 35 % of neoplasia and 50 % of NDBE datasets, and surface signal > subsurface occurred in 29 % of neoplasia and 30 % of NDBE datasets. CONCLUSIONS: Atypical glands under irregular mucosal patterns are strongly associated with neoplasia, suggesting potential markers for dysplasia and a role in pathogenesis.


Asunto(s)
Esófago de Barrett , Mucosa Esofágica , Neoplasias Esofágicas , Lesiones Precancerosas , Tomografía de Coherencia Óptica/métodos , Esófago de Barrett/diagnóstico , Esófago de Barrett/patología , Biopsia/métodos , Mucosa Esofágica/diagnóstico por imagen , Mucosa Esofágica/patología , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/patología , Esofagoscopía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Lesiones Precancerosas/diagnóstico por imagen , Lesiones Precancerosas/patología , Reproducibilidad de los Resultados
5.
Optica ; 5(1): 36-43, 2018 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-29682598

RESUMEN

Devices that perform wide field-of-view (FOV) precision optical scanning are important for endoscopic assessment and diagnosis of luminal organ disease such as in gastroenterology. Optical scanning for in vivo endoscopic imaging has traditionally relied on one or more proximal mechanical actuators, limiting scan accuracy and imaging speed. There is a need for rapid and precise two-dimensional (2D) microscanning technologies to enable the translation of benchtop scanning microscopies to in vivo endoscopic imaging. We demonstrate a new cycloid scanner in a tethered capsule for ultrahigh speed, side-viewing optical coherence tomography (OCT) endomicroscopy in vivo. The cycloid capsule incorporates two scanners: a piezoelectrically actuated resonant fiber scanner to perform a precision, small FOV, fast scan and a micromotor scanner to perform a wide FOV, slow scan. Together these scanners distally scan the beam circumferentially in a 2D cycloid pattern, generating an unwrapped 1 mm × 38 mm strip FOV. Sequential strip volumes can be acquired with proximal pullback to image centimeter-long regions. Using ultrahigh speed 1.3 µm wavelength swept-source OCT at a 1.17 MHz axial scan rate, we imaged the human rectum at 3 volumes/s. Each OCT strip volume had 166 × 2322 axial scans with 8.5 µm axial and 30 µm transverse resolution. We further demonstrate OCT angiography at 0.5 volumes/s, producing volumetric images of vasculature. In addition to OCT applications, cycloid scanning promises to enable precision 2D optical scanning for other imaging modalities, including fluorescence confocal and nonlinear microscopy.

6.
Ophthalmic Surg Lasers Imaging Retina ; 49(2): 94-102, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-29443358

RESUMEN

BACKGROUND AND OBJECTIVE: To demonstrate the feasibility of retinal and anterior segment intraoperative widefield imaging using an ultrahigh-speed, swept-source optical coherence tomography (SS-OCT) surgical microscope attachment. PATIENTS AND METHODS: A prototype post-objective SS-OCT using a 1,050-nm wavelength, 400 kHz A-scan rate, vertical cavity surface-emitting laser (VCSEL) light source was integrated to a commercial ophthalmic surgical microscope after the objective. Each widefield OCT data set was acquired in 3 seconds (1,000 × 1,000 A-scans, 12 × 12 mm2 for retina and 10 × 10 mm2 for anterior segment). RESULTS: Intraoperative SS-OCT was performed in 20 eyes of 20 patients. In six of seven membrane peels and five of seven rhegmatogenous retinal detachment repair surgeries, widefield retinal imaging enabled evaluation pre- and postoperatively. In all seven cataract cases, anterior imaging evaluated the integrity of the posterior lens capsule. CONCLUSIONS: Ultrahigh-speed SS-OCT enables widefield intraoperative viewing in the posterior and anterior eye. Widefield imaging visualizes ocular structures and pathology without requiring OCT realignment. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:94-102.].


Asunto(s)
Segmento Anterior del Ojo/diagnóstico por imagen , Extracción de Catarata/métodos , Microscopía/métodos , Imagen Óptica/métodos , Enfermedades de la Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Vitrectomía/métodos , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Periodo Intraoperatorio , Masculino , Microscopía/instrumentación , Persona de Mediana Edad , Enfermedades de la Retina/cirugía , Tomografía de Coherencia Óptica/instrumentación
8.
Opt Lett ; 42(16): 3193-3196, 2017 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-28809905

RESUMEN

Endoscopic optical coherence tomography (OCT) instruments are mostly side viewing and rely on at least one proximal scan, thus limiting accuracy of volumetric imaging and en face visualization. Previous forward-viewing OCT devices had limited axial scan speeds. We report a forward-viewing fiber scanning 3D-OCT probe with 900 µm field of view and 5 µm transverse resolution, imaging at 1 MHz axial scan rate in the human gastrointestinal tract. The probe is 3.3 mm diameter and 20 mm rigid length, thus enabling passage through the endoscopic channel. The scanner has 1.8 kHz resonant frequency, and each volumetric acquisition takes 0.17 s with 2 volumes/s display. 3D-OCT and angiography imaging of the colon was performed during surveillance colonoscopy.

9.
Gastrointest Endosc ; 86(3): 476-484.e3, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28167119

RESUMEN

BACKGROUND AND AIMS: Angiogenesis is associated with neoplastic progression of Barrett's esophagus (BE). Volumetric optical coherence tomography angiography (OCTA) visualizes subsurface microvasculature without exogenous contrast agents. We investigated the association of OCTA microvascular features with low-grade dysplasia (LGD) and high-grade dysplasia (HGD). METHODS: Fifty-two patients undergoing BE surveillance or endoscopic eradication therapies for dysplasia were imaged using volumetric OCTA and corresponding histologic diagnoses wre obtained to yield 97 data sets (nondysplastic BE [NDBE], 74; LGD, 10; HGD, 13). After evaluating OCTA image quality, 54 datasets (NDBE, 35; LGD, 8; HGD, 11) from 32 patients were used to develop a training and reading protocol. The association of abnormal vessel branching and heterogeneous vessel size with LGD/HGD and a regular honeycomb vessel pattern with NDBE were investigated. RESULTS: Blinded OCTA reading of 41 OCTA datasets (NDBE, 27; LGD, 7; HGD, 7) was performed by readers with various levels of OCT/OCTA experience including 3 OCT trainees, 1 gastroenterologist, and 2 gastroenterology fellows. Among the 6 readers, OCTA features of abnormal vessel branching and heterogeneous vessel size had an overall 94% sensitivity (95% CI, 89-99) and 69% specificity (95% CI, 62-76) for differentiating LGD/HGD versus NDBE with a mean reading time of 45 seconds per data set and moderate (kappa = .58) interobserver agreement. CONCLUSIONS: Volumetric en face OCTA imaging enables rapid examination of depth resolved microvascular features with near-microscopic resolution. OCTA can visualize microvascular features associated with LGD/HGD with high accuracy, which motivates new technologic advances and future studies investigating the diagnostic performance of OCTA.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Esófago de Barrett/diagnóstico por imagen , Neoplasias Esofágicas/diagnóstico por imagen , Microvasos/diagnóstico por imagen , Anciano , Angiografía/métodos , Progresión de la Enfermedad , Esofagoscopía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Tomografía de Coherencia Óptica/métodos
10.
Retina ; 36 Suppl 1: S118-S126, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28005670

RESUMEN

PURPOSE: Currently available optical coherence tomography angiography systems provide information about blood flux but only limited information about blood flow speed. The authors develop a method for mapping the previously proposed variable interscan time analysis (VISTA) algorithm into a color display that encodes relative blood flow speed. METHODS: Optical coherence tomography angiography was performed with a 1,050 nm, 400 kHz A-scan rate, swept source optical coherence tomography system using a 5 repeated B-scan protocol. Variable interscan time analysis was used to compute the optical coherence tomography angiography signal from B-scan pairs having 1.5 millisecond and 3.0 milliseconds interscan times. The resulting VISTA data were then mapped to a color space for display. RESULTS: The authors evaluated the VISTA visualization algorithm in normal eyes (n = 2), nonproliferative diabetic retinopathy eyes (n = 6), proliferative diabetic retinopathy eyes (n = 3), geographic atrophy eyes (n = 4), and exudative age-related macular degeneration eyes (n = 2). All eyes showed blood flow speed variations, and all eyes with pathology showed abnormal blood flow speeds compared with controls. CONCLUSION: The authors developed a novel method for mapping VISTA into a color display, allowing visualization of relative blood flow speeds. The method was found useful, in a small case series, for visualizing blood flow speeds in a variety of ocular diseases and serves as a step toward quantitative optical coherence tomography angiography.


Asunto(s)
Retinopatía Diabética/fisiopatología , Atrofia Geográfica/fisiopatología , Algoritmos , Velocidad del Flujo Sanguíneo/fisiología , Estudios de Casos y Controles , Coroides/irrigación sanguínea , Angiografía por Tomografía Computarizada/métodos , Retinopatía Diabética/diagnóstico por imagen , Atrofia Geográfica/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Imagen Multimodal , Tomografía de Coherencia Óptica/métodos
12.
Biomed Opt Express ; 7(8): 2927-42, 2016 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27570688

RESUMEN

We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 µm axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 frames per second (fps) with a ~30 µm (FWHM) spot size. Volumetric imaging is achieved by proximal pullback of the micromotor assembly within the balloon at 1.5 mm/sec. Volumetric data consisting of 4200 circumferential images of 5,000 A-scans each over a 2.6 cm length, covering a ~13 cm(2) area is acquired in <18 seconds. A non-rigid image registration algorithm is used to suppress motion artifacts from non-uniform rotational distortion (NURD), cardiac motion or respiration. En face OCT images at various depths can be generated. OCT angiography (OCTA) is computed using intensity decorrelation between sequential pairs of circumferential scans and enables three-dimensional visualization of vasculature. Wide area volumetric OCT and OCTA imaging of the swine esophagus in vivo is demonstrated.

13.
Optica ; 3(12): 1496-1503, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28239628

RESUMEN

Optical coherence tomography (OCT) is a powerful three-dimensional (3D) imaging modality with micrometer-scale axial resolution and up to multi-GigaVoxel/s imaging speed. However, the imaging range of high-speed OCT has been limited. Here, we report 3D OCT over cubic meter volumes using a long coherence length, 1310 nm vertical-cavity surface-emitting laser and silicon photonic integrated circuit dual-quadrature receiver technology combined with enhanced signal processing. We achieved 15 µm depth resolution for tomographic imaging at a 100 kHz axial scan rate over a 1.5 m range. We show 3D macroscopic imaging examples of a human mannequin, bicycle, machine shop gauge blocks, and a human skull/brain model. High-bandwidth, meter-range OCT demonstrates new capabilities that promise to enable a wide range of biomedical, scientific, industrial, and research applications.

14.
J Lightwave Technol ; 33(16): 3461-3468, 2015 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-26594089

RESUMEN

In this paper, we present a 1050 nm electrically-pumped micro-electro-mechanically-tunable vertical-cavity-surface-emitting-laser (MEMS-VCSEL) with a record dynamic tuning bandwidth of 63.8 nm, suitable for swept source optical coherence tomography (SS-OCT) imaging. These devices provide reduced cost & complexity relative to previously demonstrated optically pumped devices by obviating the need for a pump laser and associated hardware. We demonstrate ophthalmic SS-OCT imaging with the electrically-pumped MEMS-VCSEL at a 400 kHz axial scan rate for wide field imaging of the in vivo human retina over a 12 mm × 12 mm field and for OCT angiography of the macula over 6 mm × 6 mm & 3 mm × 3 mm fields to show retinal vasculature and capillary structure near the fovea. These results demonstrate the feasibility of electrically pumped MEMS-VCSELs in ophthalmic instrumentation, the largest clinical application of OCT. In addition, we estimate that the 3 dB coherence length in air is 225 meters ± 51 meters, far greater than required for ophthalmic SS-OCT and suggestive of other distance ranging applications.

15.
Biomed Opt Express ; 6(4): 1146-63, 2015 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-25909001

RESUMEN

Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

16.
Opt Lett ; 39(20): 5973-6, 2014 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-25361133

RESUMEN

We demonstrate a computationally efficient method for correcting the nonuniform rotational distortion (NURD) in catheter-based imaging systems to improve endoscopic en face optical coherence tomography (OCT) and OCT angiography. The method performs nonrigid registration using fiducial markers on the catheter to correct rotational speed variations. Algorithm performance is investigated with an ultrahigh-speed endoscopic OCT system and micromotor catheter. Scan nonuniformity is quantitatively characterized, and artifacts from rotational speed variations are significantly reduced. Furthermore, we present endoscopic en face OCT and OCT angiography images of human gastrointestinal tract in vivo to demonstrate the image quality improvement using the correction algorithm.


Asunto(s)
Angiografía/instrumentación , Artefactos , Catéteres , Procesamiento de Imagen Asistido por Computador/métodos , Rotación , Tomografía de Coherencia Óptica/instrumentación , Algoritmos , Angiografía/normas , Marcadores Fiduciales , Tracto Gastrointestinal/diagnóstico por imagen , Humanos , Tomografía de Coherencia Óptica/normas
17.
Artículo en Inglés | MEDLINE | ID: mdl-25423628

RESUMEN

BACKGROUND AND OBJECTIVE: To investigate the potential of ultrahigh-speed swept-source optical coherence tomography angiography (OCTA) to visualize retinal and choroidal vascular changes in patients with exudative age-related macular degeneration (AMD). PATIENTS AND METHODS: Observational, prospective cross-sectional study. An ultrahigh-speed swept-source prototype was used to perform OCTA of the retinal and choriocapillaris microvasculature in 63 eyes of 32 healthy controls and 19 eyes of 15 patients with exudative AMD. MAIN OUTCOME MEASURE: qualitative comparison of the retinal and choriocapillaris microvasculature in the two groups. RESULTS: Choroidal neovascularization (CNV) was clearly visualized in 16 of the 19 eyes with exudative AMD, located above regions of severe choriocapillaris alteration. In 14 of these eyes, the CNV lesions were surrounded by regions of choriocapillaris alteration. CONCLUSION: OCTA may offer noninvasive monitoring of the retinal and choriocapillaris microvasculature in patients with CNV, which may assist in diagnosis and monitoring.


Asunto(s)
Angiografía , Coroides/irrigación sanguínea , Neovascularización Coroidal/diagnóstico , Tomografía de Coherencia Óptica , Degeneración Macular Húmeda/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Arterias Ciliares/diagnóstico por imagen , Arterias Ciliares/patología , Estudios Transversales , Exudados y Transudados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Adulto Joven
18.
Biomed Opt Express ; 5(9): 2931-49, 2014 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-25401008

RESUMEN

Polarization sensitive optical coherence tomography (PS-OCT) is a functional extension of conventional OCT and can assess depth-resolved tissue birefringence in addition to intensity. Most existing PS-OCT systems are relatively complex and their clinical translation remains difficult. We present a simple and robust all-fiber PS-OCT system based on swept source technology and polarization depth-encoding. Polarization multiplexing was achieved using a polarization maintaining fiber. Polarization sensitive signals were detected using fiber based polarization beam splitters and polarization controllers were used to remove the polarization ambiguity. A simplified post-processing algorithm was proposed for speckle noise reduction relaxing the demand for phase stability. We demonstrated systems design for both ophthalmic and catheter-based PS-OCT. For ophthalmic imaging, we used an optical clock frequency doubling method to extend the imaging range of a commercially available short cavity light source to improve polarization depth-encoding. For catheter based imaging, we demonstrated 200 kHz PS-OCT imaging using a MEMS-tunable vertical cavity surface emitting laser (VCSEL) and a high speed micromotor imaging catheter. The system was demonstrated in human retina, finger and lip imaging, as well as ex vivo swine esophagus and cardiovascular imaging. The all-fiber PS-OCT is easier to implement and maintain compared to previous PS-OCT systems and can be more easily translated to clinical applications due to its robust design.

20.
Br J Ophthalmol ; 98(10): 1368-73, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24831719

RESUMEN

AIMS: To investigate swept-source optical coherence tomography (OCT) angiography in the optic nerve head (ONH) and parafoveal regions in patients with multiple sclerosis (MS). METHODS: Fifty-two MS eyes and 21 healthy control (HC) eyes were included. There were two MS subgroups: 38 MS eyes without an optic neuritis (ON) history (MS -ON), and 14 MS eyes with an ON history (MS +ON). The OCT images were captured by high-speed 1050 nm swept-source OCT. The ONH flow index (FI) and parafoveal FI were quantified from OCT angiograms. RESULTS: The mean ONH FI was 0.160 ± 0.010 for the HC group, 0.156 ± 0.017 for the MS-ON group, and 0.140 ± 0.020 for the MS+ON group. The ONH FI of the MS+ON group was reduced by 12.5% compared to HC eyes (p=0.004). A higher percentage of MS+ON eyes had abnormal ONH FI compared to HC patients (43% vs 5%, p=0.01). Mean parafoveal FIs were 0.126 ± 0.007, 0.127 ± 0.010, and 0.129 ± 0.005 for the HC, MS-ON, and MS +ON groups, respectively, and did not differ significantly among them. The coefficient of variation (CV) of intravisit repeatability and intervisit reproducibility were 1.03% and 4.53% for ONH FI, and 1.65% and 3.55% for parafoveal FI. CONCLUSIONS: Based on OCT angiography, the FI measurement is feasible, highly repeatable and reproducible, and it is suitable for clinical measurement of ONH and parafoveal perfusion. The ONH FI may be useful in detecting damage from ON and quantifying its severity.


Asunto(s)
Angiografía con Fluoresceína , Fóvea Central/irrigación sanguínea , Esclerosis Múltiple/fisiopatología , Disco Óptico/irrigación sanguínea , Neuritis Óptica/fisiopatología , Vasos Retinianos/fisiología , Tomografía de Coherencia Óptica , Adolescente , Adulto , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Agudeza Visual/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...