Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Clin Microbiol ; 58(1)2019 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-31619529

RESUMEN

Despite the adaptation of international standards, quantitative viral load testing of transplant-associated viruses continues to be limited by interlaboratory disagreement. Studies have suggested that this disagreement and the poor commutability of standards may, in some cases, be linked to amplicon size and the fragmentation of circulating viral DNA. We evaluated target fragmentation as a cause of noncommutability and pretest fragmentation of quantitative standards as a potential means of increasing commutability and interassay agreement. Forty-two cytomegalovirus (CMV)-positive and 41 Epstein-Barr virus (EBV)-positive plasma samples, together with two different quantitative standards for each virus, were tested as unknowns using 10 different quantitative PCR assays at 5 different laboratories. Standards were tested both intact and after intentional fragmentation by ultrasonication. Quantitative agreement between methods was assessed, together with commutability, using multiple statistical approaches. Most assays yielded results within 0.5 log10 IU/ml of the mean for CMV, while for EBV a greater variability of up to 1.5 log10 IU/ml of the mean was shown. Commutability showed marked improvement following fragmentation of both CMV standards but not after fragmentation of the EBV standards. These findings confirm the impact of amplicon size and target fragmentation on commutability for CMV and suggest that for some (but not all) viruses, interlaboratory harmonization can be improved through the use of fragmented quantitative standards.


Asunto(s)
Infecciones por Citomegalovirus/diagnóstico , Infecciones por Citomegalovirus/virología , Citomegalovirus/genética , Infecciones por Virus de Epstein-Barr/diagnóstico , Infecciones por Virus de Epstein-Barr/virología , Herpesvirus Humano 4/genética , Carga Viral/métodos , ADN Viral , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Viral/normas
2.
J Clin Microbiol ; 57(1)2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30381420

RESUMEN

Despite advances in the standardization of quantitative DNAemia tests and efforts to better understand and characterize the performance of reference materials in different assays, it remains unclear how the commutability performance of reference materials is related to intra- and interassay agreement. Building upon previous work, we describe a comprehensive framework to determine the relationship of commutability with assay accuracy and agreement. The use of this framework is illustrated using previously generated data regarding the performance of four quantitative Epstein-Bar virus (EBV) PCR assays with the WHO and ABI standards as examples. The use of these statistical tools can link the performance characteristics of one or more assays with predetermined clinical decision limits and may help improve the development, validation, and clinical utility of such DNAemia tests.


Asunto(s)
Técnicas de Laboratorio Clínico/métodos , ADN Viral/sangre , Pruebas Diagnósticas de Rutina/normas , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Carga Viral/normas , Técnicas de Laboratorio Clínico/normas , ADN Viral/genética , Interpretación Estadística de Datos , Infecciones por Virus de Epstein-Barr/diagnóstico , Infecciones por Virus de Epstein-Barr/virología , Herpesvirus Humano 4/genética , Herpesvirus Humano 4/aislamiento & purificación , Humanos , Estándares de Referencia , Carga Viral/métodos
4.
J Clin Microbiol ; 54(10): 2602-8, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27535685

RESUMEN

A potential benefit of digital PCR is a reduction in result variability across assays and platforms. Three sets of PCR reagents were tested on two digital PCR systems (Bio-Rad and RainDance), using three different sets of PCR reagents for quantitation of cytomegalovirus (CMV). Both commercial quantitative viral standards and 16 patient samples (n = 16) were tested. Quantitative accuracy (compared to nominal values) and variability were determined based on viral standard testing results. Quantitative correlation and variability were assessed with pairwise comparisons across all reagent-platform combinations for clinical plasma sample results. The three reagent sets, when used to assay quantitative standards on the Bio-Rad system, all showed a high degree of accuracy, low variability, and close agreement with one another. When used on the RainDance system, one of the three reagent sets appeared to have a much better correlation to nominal values than did the other two. Quantitative results for patient samples showed good correlation in most pairwise comparisons, with some showing poorer correlations when testing samples with low viral loads. Digital PCR is a robust method for measuring CMV viral load. Some degree of result variation may be seen, depending on platform and reagents used; this variation appears to be greater in samples with low viral load values.


Asunto(s)
Infecciones por Citomegalovirus/virología , Citomegalovirus/aislamiento & purificación , ADN Viral/análisis , Indicadores y Reactivos , Reacción en Cadena de la Polimerasa/métodos , Carga Viral/métodos , Citomegalovirus/genética , ADN Viral/genética , Humanos , Reproducibilidad de los Resultados
5.
J Clin Microbiol ; 54(6): 1616-1623, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27076654

RESUMEN

Given recent advances in the development of quantitative standards, particularly WHO international standards, efforts to better understand the commutability of reference materials have been made. Existing approaches in evaluating commutability include prediction intervals and correspondence analysis; however, the results obtained from existing approaches may be ambiguous. We have developed a "deviation-from-ideal" (DFI) approach to evaluate commutability of standards and applied it to the assessment of Epstein-Bar virus (EBV) load testing in four quantitative PCR assays, treating digital PCR as a reference assay. We then discuss advantages and limitations of the DFI approach as well as experimental design to best evaluate the commutability of an assay in practice.


Asunto(s)
Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Estándares de Referencia , Carga Viral/métodos , Carga Viral/normas , Herpesvirus Humano 4/genética , Herpesvirus Humano 4/aislamiento & purificación , Humanos
6.
Clin Pharmacol Ther ; 99(6): 651-60, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26663398

RESUMEN

Using broad interrogation of clinically relevant drug absorption, distribution, metabolism, and excretion (ADME) genes on the DMET platform, we identified a genetic variant in SLCO1B1 (rs2291075; c.597C>T), encoding the transporter OATP1B1, associated with event-free (P = 0.006, hazard ratio = 1.74) and overall survival (P = 0.012, hazard ratio = 1.85) in children with de novo acute myeloid leukemia (AML). Lack of SLCO1B1 expression in leukemic blasts suggested the association might be due to an inherited rather than a somatic effect. rs2291075 was in strong linkage with known functional variants rs2306283 (c.388A>G) and rs4149056 (c.521T>C). Functional studies in vitro determined that four AML-directed chemotherapeutics (cytarabine, daunorubicin, etoposide, and mitoxantrone) are substrates for OATP1B1 and the mouse ortholog Oatp1b2. In vivo pharmacokinetic studies using Oatp1b2-deficient mice further confirmed our results. Collectively, these findings demonstrate an important role for OATP1B1 in the systemic pharmacokinetics of multiple drugs used in the treatment of AML and suggest that inherited variability in host transporter function influences the effectiveness of therapy.


Asunto(s)
Leucemia Mieloide Aguda/tratamiento farmacológico , Leucemia Mieloide Aguda/genética , Transportador 1 de Anión Orgánico Específico del Hígado/genética , Animales , Antineoplásicos/metabolismo , Protocolos de Quimioterapia Combinada Antineoplásica/metabolismo , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Niño , Estudios de Cohortes , Citarabina/farmacocinética , ADN/genética , ADN/aislamiento & purificación , Femenino , Ligamiento Genético , Variación Genética , Humanos , Masculino , Ratones , Ratones Noqueados , Polimorfismo de Nucleótido Simple , Análisis de Supervivencia , Resultado del Tratamiento
7.
J Clin Microbiol ; 53(10): 3325-33, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26269622

RESUMEN

Quantitative detection of cytomegalovirus (CMV) DNA has become a standard part of care for many groups of immunocompromised patients; recent development of the first WHO international standard for human CMV DNA has raised hopes of reducing interlaboratory variability of results. Commutability of reference material has been shown to be necessary if such material is to reduce variability among laboratories. Here we evaluated the commutability of the WHO standard using 10 different real-time quantitative CMV PCR assays run by eight different laboratories. Test panels, including aliquots of 50 patient samples (40 positive samples and 10 negative samples) and lyophilized CMV standard, were run, with each testing center using its own quantitative calibrators, reagents, and nucleic acid extraction methods. Commutability was assessed both on a pairwise basis and over the entire group of assays, using linear regression and correspondence analyses. Commutability of the WHO material differed among the tests that were evaluated, and these differences appeared to vary depending on the method of statistical analysis used and the cohort of assays included in the analysis. Depending on the methodology used, the WHO material showed poor or absent commutability with up to 50% of assays. Determination of commutability may require a multifaceted approach; the lack of commutability seen when using the WHO standard with several of the assays here suggests that further work is needed to bring us toward true consensus.


Asunto(s)
Infecciones por Citomegalovirus/diagnóstico , Citomegalovirus/aislamiento & purificación , Estándares de Referencia , Carga Viral/métodos , Carga Viral/normas , Infecciones por Citomegalovirus/virología , Humanos , Reproducibilidad de los Resultados , Organización Mundial de la Salud
8.
J Clin Microbiol ; 53(5): 1500-5, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25694529

RESUMEN

The recent development of the 1st WHO International Standard for human cytomegalovirus (CMV) and the introduction of commercially produced secondary standards have raised hopes of improved agreement among laboratories performing quantitative PCR for CMV. However, data to evaluate the trueness and uniformity of secondary standards and the consistency of results achieved when these materials are run on various assays are lacking. Three concentrations of each of the three commercially prepared secondary CMV standards were tested in quadruplicate by three real-time and two digital PCR methods. The mean results were compared in a pairwise fashion with nominal values provided by each manufacturer. The agreement of results among all methods for each sample and for like concentrations of each standard was also assessed. The relationship between the nominal values of standards and the measured values varied, depending upon the assay used and the manufacturer of the standards, with the degree of bias ranging from +0.6 to -1.0 log10 IU/ml. The mean digital PCR result differed significantly among the secondary standards, as did the results of the real-time PCRs, particularly when plotted against nominal log10 IU values. Commercially available quantitative secondary CMV standards produce variable results when tested by different real-time and digital PCR assays, with various magnitudes of bias compared to nominal values. These findings suggest that the use of such materials may not achieve the intended uniformity among laboratories measuring CMV viral load, as envisioned by adaptation of the WHO standard.


Asunto(s)
Infecciones por Citomegalovirus/virología , Citomegalovirus/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Estándares de Referencia , Carga Viral/métodos , Citomegalovirus/genética , Infecciones por Citomegalovirus/diagnóstico , Humanos , Técnicas de Diagnóstico Molecular/normas , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Carga Viral/normas
9.
J Clin Microbiol ; 51(2): 540-6, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23224089

RESUMEN

Quantitative real-time PCR (QRT-PCR) has been widely implemented for clinical viral load testing, but a lack of standardization and relatively poor precision have hindered its usefulness. Digital PCR offers highly precise, direct quantification without requiring a calibration curve. Performance characteristics of real-time PCR were compared to those of droplet digital PCR (ddPCR) for cytomegalovirus (CMV) load testing. Tenfold serial dilutions of the World Health Organization (WHO) and the National Institute of Standards and Technology (NIST) CMV quantitative standards were tested, together with the AcroMetrix CMV tc panel (Life Technologies, Carlsbad, CA) and 50 human plasma specimens. Each method was evaluated using all three standards for quantitative linearity, lower limit of detection (LOD), and accuracy. Quantitative correlation, mean viral load, and variability were compared. Real-time PCR showed somewhat higher sensitivity than ddPCR (LODs, 3 log(10) versus 4 log(10) copies/ml and IU/ml for NIST and WHO standards, respectively). Both methods showed a high degree of linearity and quantitative correlation for standards (R(2) ≥ 0.98 in each of 6 regression models) and clinical samples (R(2) = 0.93) across their detectable ranges. For higher concentrations, ddPCR showed less variability than QRT-PCR for the WHO standards and AcroMetrix standards (P < 0.05). QRT-PCR showed less variability and greater sensitivity than did ddPCR in clinical samples. Both digital and real-time PCR provide accurate CMV load data over a wide linear dynamic range. Digital PCR may provide an opportunity to reduce the quantitative variability currently seen using real-time PCR, but methods need to be further optimized to match the sensitivity of real-time PCR.


Asunto(s)
Infecciones por Citomegalovirus/diagnóstico , Infecciones por Citomegalovirus/virología , Citomegalovirus/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Estándares de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Viral
11.
Leukemia ; 25(10): 1570-7, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21647154

RESUMEN

To investigate the frequency of isocitrate dehydrogenase 1 (IDH1) and 2 (IDH2) mutations in pediatric acute myeloid leukemia (AML) and acute lymphoid leukemia (ALL), we sequenced these genes in diagnostic samples from 515 patients (227 AMLs and 288 ALLs). Somatic IDH1/IDH2 mutations were rare in ALL (N=1), but were more common in AML, occurring in 3.5% (IDH1 N=3 and IDH2 N=5), with the frequency higher in AMLs with a normal karyotype (9.8%). The identified IDH1 mutations occurred in codon 132 resulting in replacement of arginine with either cysteine (N=3) or histidine (N=1). By contrast, mutations in IDH2 did not affect the homologous residue but instead altered codon 140, resulting in replacement of arginine with either glutamine (N=4) or tryptophan (N=1). Structural modeling of IDH2 suggested that codon 140 mutations disrupt the enzyme's ability to bind its substrate isocitrate. Accordingly, recombinant IDH2 R140Q/W were unable to carry out the decarboxylation of isocitrate to α-ketoglutarate (α-KG), but instead gained the neomorphic activity to reduce α-KG to R(-)-2-hydroxyglutarete (2-HG). Analysis of primary leukemic blasts confirmed high levels of 2-HG in AMLs with IDH1/IDH2 mutations. Interestingly, 3/5 AMLs with IDH2 mutations had FLT3-activating mutations, raising the possibility that these mutations cooperate in leukemogenesis.


Asunto(s)
Isocitrato Deshidrogenasa/genética , Leucemia Mieloide Aguda/genética , Mutación , Leucemia-Linfoma Linfoblástico de Células Precursoras/genética , Secuencia de Bases , Niño , Cromatografía por Intercambio Iónico , Cartilla de ADN , Humanos , Hibridación Fluorescente in Situ , Leucemia Mieloide Aguda/enzimología , Mutagénesis Sitio-Dirigida , Reacción en Cadena de la Polimerasa , Leucemia-Linfoma Linfoblástico de Células Precursoras/enzimología , Espectrometría de Masas en Tándem
13.
Leukemia ; 23(8): 1410-6, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19242495

RESUMEN

Because cladribine can increase cytarabine triphosphate levels, we tested a cladribine-cytarabine combination in the St Jude AML97, trial in which this combination was administered before standard chemotherapy to 96 children with acute myeloid leukemia (AML) or myelodysplastic syndrome. Patients received a 5-day course of cladribine (9 mg/m(2) per dose) and cytarabine either as daily 2-h infusions (500 mg/m(2) per dose) (arm A) or a continuous infusion (500 mg/m(2) per day) (arm B). Ara-CTP levels and inhibition of DNA synthesis increased from day 1 to day 2, but were not different between the two arms. In addition, the median blast percentages at day 15 did not differ between arms A and B, but patients treated in arm A had shorter intervals between the initiation of the first and second courses of therapy. Thus, although there were trends toward better complete remission rates and overall survival for patients treated in arm B, the reduced efficacy of arm A may have been partially compensated by more intense timing of therapy for that group. For all patients, 5-year event-free survival and overall survival estimates were 44.1+/-5.4 and 50.0+/-5.5%. Our results suggest that cladribine in combination with continuous-infusion cytarabine is effective therapy for childhood AML.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Leucemia Mieloide/tratamiento farmacológico , Síndromes Mielodisplásicos/tratamiento farmacológico , Enfermedad Aguda , Adolescente , Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Asparaginasa/administración & dosificación , Niño , Preescolar , Cladribina/administración & dosificación , Terapia Combinada , Citarabina/administración & dosificación , Daunorrubicina/administración & dosificación , Síndrome de Down/complicaciones , Esquema de Medicación , Etopósido/administración & dosificación , Trasplante de Células Madre Hematopoyéticas , Humanos , Lactante , Estimación de Kaplan-Meier , Leucemia Mieloide/genética , Leucemia Mieloide/cirugía , Pronóstico , Modelos de Riesgos Proporcionales , Inducción de Remisión , Adulto Joven
15.
J Clin Microbiol ; 46(1): 157-63, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17989187

RESUMEN

Quantification of Epstein-Barr virus (EBV) in peripheral blood is important for the diagnosis and management of serious EBV diseases, including posttransplant lymphoproliferative disorder. A variety of PCR-based methods are currently in use; however, there is little information on their comparability. This study assessed the relative performance of different quantitative assays. A multicenter comparative study was performed at eight sites using three panels consisting of serial dilutions of quantified EBV DNA and extracts from a total of 19 whole-blood specimens. Samples were distributed and tested blindly. Instrumentation, probe chemistries, amplification targets, and other test-related aspects varied considerably between laboratories. Each laboratory's calibration curve indicated strong evidence of a consistent log-linear relationship between viral load and cycle threshold, suggesting that intralaboratory tracking of a given patient would yield similar relative quantitative trends among the participating test sites. There was strong concordance among laboratories with respect to qualitative test results; however, marked quantitative discordance was seen. For most samples, the across-laboratory interquartile range of the reported viral load (in copies/microl) was roughly 0.6 log-units, and for one sample the overall range was approximately 4.2 log-units. While intralaboratory tracking of patients may yield similar results, these data indicate a need for caution when attempting to compare clinical results obtained at different institutions and suggest the potential value to be gained by more standardized testing methodology.


Asunto(s)
ADN Viral/sangre , Infecciones por Virus de Epstein-Barr/virología , Herpesvirus Humano 4/aislamiento & purificación , Reacción en Cadena de la Polimerasa/métodos , Carga Viral/métodos , Calibración/normas , Humanos , Reproducibilidad de los Resultados , Carga Viral/normas
16.
J Clin Virol ; 40(4): 295-300, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17959413

RESUMEN

BACKGROUND: Detection and quantification of adenovirus (ADV) in peripheral blood specimens has become an increasingly important tool in the management of immunosuppressed patients. Investigators have described the use of whole blood (WB), peripheral blood mononuclear cells (PBMC), serum and plasma but no studies have compared the utility of these different sample types for use in a clinical diagnostic assay. OBJECTIVES: To determine the optimal blood compartment for quantitative real-time measurement of adenovirus in peripheral blood specimens. STUDY DESIGN: WB, PBMC, and plasma representing 338 samples from 148 patients were tested for ADV by quantitative real-time PCR (qrt-PCR) and the results compared for concordance of both qualitative sensitivity and viral load among positive specimens. RESULTS: There was no significant difference in qualitative sensitivity among the three tested specimen types. Quantitative values of WB and plasma were similar and tended to be greater than those found in PBMC samples. Comparison of consecutive positive samples within individual patients showed that viral loads tracked similarly over time, irrespective of the sample type tested. CONCLUSION: While WB and plasma do not offer a significant increase in sensitivity over PBMC, they may offer benefits in terms of reduced processing costs and laboratory turn around time.


Asunto(s)
Infecciones por Adenoviridae/sangre , Infecciones por Adenoviridae/virología , Adenoviridae/aislamiento & purificación , Leucocitos Mononucleares/virología , Reacción en Cadena de la Polimerasa/métodos , Infecciones por Adenoviridae/inmunología , Humanos , Huésped Inmunocomprometido , Sensibilidad y Especificidad , Carga Viral/métodos
17.
Leukemia ; 21(10): 2128-36, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17673902

RESUMEN

The genetic risk factors for etoposide-induced leukemia with MLL translocations remain largely unknown. To identify genetic risk factors for and novel characteristics of secondary leukemia, we profiled 116,204 single nucleotide polymorphisms (SNPs) in germline and paired leukemic cell DNA from 13 secondary leukemia/myelodysplasia cases and germline DNA from 13 matched and 156 unmatched controls, all with acute lymphoblastic leukemia treated with etoposide. We analyzed global gene expression from a partially overlapping cohort. No single locus was altered in most cases. We discovered 81 regions of loss of heterozygosity (LOH) in leukemic blasts and 309 SNPs whose allele frequencies differed in cases vs controls. Candidate genes were prioritized on the basis of genes whose SNPs or expression differentiated cases from controls or showed LOH or copy number change in germline vs paired blast DNA from the 13 cases. Three biological pathways were altered: adhesion, Wnt signaling and regulation of actin. Validation experiments using a genome scan for etoposide-induced leukemogenic MLL chimeric fusions in 15 HapMap cell lines also implicated genes involved in adhesion, a process linked to de novo leukemogenesis. Independent clinical epidemiologic and in vitro genome-wide approaches converged to identify novel pathways that may contribute to therapy-induced leukemia.


Asunto(s)
Genoma Humano , Leucemia/inducido químicamente , Leucemia/genética , Leucemia/patología , Adolescente , Estudios de Casos y Controles , Adhesión Celular , Niño , Preescolar , Estudios de Cohortes , Etopósido/efectos adversos , Etopósido/farmacología , Femenino , Frecuencia de los Genes , Humanos , Lactante , Pérdida de Heterocigocidad , Masculino , Polimorfismo de Nucleótido Simple , Translocación Genética
18.
Leukemia ; 19(12): 2125-9, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16281077

RESUMEN

Despite substantial progress in the management of childhood acute myeloid leukemia (AML), only about 50% of patients are cured by intensive chemotherapy. The long-term results of clinical trials may reveal principles that can guide the development of future therapy. From 1980 to 2000, 251 patients <15 years of age with newly diagnosed AML were enrolled on one of the five consecutive St Jude AML studies. The median age of the 128 boys and 123 girls was 6.2 years; 193 were white, 45 black, and 13 of other racial groups. With the exception of one protocol (AML-83), outcomes improved in general over the two decades. The estimated 5-year event-free survival (+/-s.e.) was 30.8+/-5.6% for AML-80; 11.1+/-4.3% for AML-83; 35.9+/-7.4% for AML-87; 43.5+/-6.2% for AML-91; and 45.0+/-11.1% for AML-97. Resistant or relapsed AML caused the great majority of treatment failures. Increasing the intensity of chemotherapy (AML-87) did not improve outcome, partially because of toxicity, nor did prolonging postremission therapy by adding sequential myeloablative (AML-80) or nonmyeloablative (AML-83) chemotherapy cycles. We conclude that subtype-specific therapies are needed to replace the 'one size fits all' strategy of the past two decades.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Protocolos Antineoplásicos/normas , Leucemia Mieloide/terapia , Enfermedad Aguda , Adolescente , Protocolos de Quimioterapia Combinada Antineoplásica/toxicidad , Niño , Preescolar , Relación Dosis-Respuesta a Droga , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Leucemia Mieloide/mortalidad , Masculino , Inducción de Remisión/métodos , Análisis de Supervivencia , Insuficiencia del Tratamiento , Resultado del Tratamiento
19.
Bull Math Biol ; 63(5): 995-1002, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11565413

RESUMEN

Tang and Waterman (1990, Bulletin of Mathematical Biology, 52, 455-475) give an estimate of the fraction of clonable genomic DNA by complete digestion with a single restriction enzyme. However, their argument neglects the 'end effects' of restriction enzyme digestion. This effectively assumes that the DNA is of infinite length. However, neglecting the end effects is not necessary to obtain useful estimates of the fraction of clonable DNA. An alternative approach is taken to estimating the fraction of clonable DNA that accounts for the finite nature of the DNA strand. This approach yields the Tang and Waterman estimate by allowing the genome length to go to infinity. Comparisons based on simulation studies show the finite approach to be more accurate than Tang and Waterman's estimate, especially for shorter genomes. Sequence-based studies also show that the proposed method is often superior to the Tang-Waterman estimate.


Asunto(s)
Clonación Molecular/métodos , ADN/genética , Biblioteca de Genes , Modelos Genéticos , Animales , Simulación por Computador , ADN/metabolismo , Genoma , Humanos , Polimorfismo de Longitud del Fragmento de Restricción
20.
Eur J Pharmacol ; 367(1): 139-42, 1999 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-10082277

RESUMEN

Radiolabeled dopamine D4 receptor-selective agents ([3H]1-benzyl-4-[ N-(3-isopropoxy-2-pyridinyl)-N-methyl]-aminopiperidine maleate; [3 H]PNU-101958. and [125I]1-[4-iodobenzyl]-4-[ N-(3-isopropoxy-2-pyridinyl)-N-methyl]-aminopiperidine; [125I]RBI-257) were prepared and characterized. With D4.2- and D2L receptor-transfected cell membranes, [3H]PNU-101958 showed high dopamine D4 receptor affinity and selectivity, and potent inhibition by dopamine D4 receptor-selective compounds. However, its binding with rat brain homogenates showed little regional selectivity, and pharmacology inconsistent with selective dopamine D4 receptor labeling. Autoradiography indicated partial displacement of [3H]PNU-101958 by unlabeled dopamine D4 receptor ligands without regional selectivity, and lack of selective labeling with [125I]RBI-257. The results encourage further efforts to develop better dopamine D4 receptor-selective radioligands.


Asunto(s)
Aminopiridinas/farmacología , Piperidinas/farmacología , Receptores de Dopamina D2/efectos de los fármacos , Aminopiridinas/metabolismo , Animales , Unión Competitiva/efectos de los fármacos , Células CHO , Membrana Celular/efectos de los fármacos , Membrana Celular/metabolismo , Cricetinae , Dopaminérgicos/metabolismo , Dopaminérgicos/farmacología , Antagonistas de Dopamina/farmacología , Haloperidol/farmacología , Humanos , Técnicas In Vitro , Ligandos , Masculino , Piperidinas/metabolismo , Prosencéfalo/efectos de los fármacos , Prosencéfalo/metabolismo , Ensayo de Unión Radioligante , Ratas , Ratas Sprague-Dawley , Receptores de Dopamina D2/metabolismo , Receptores de Dopamina D4 , Espiperona/farmacología , Tritio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...