Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Prosthet Dent ; 121(4): 590-597.e3, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30509548

RESUMEN

STATEMENT OF PROBLEM: Different parameters can influence the adaptation of computer-assisted design and computer-assisted manufacturing (CAD-CAM) inlay/onlay restorations. However, systematic reviews to identify and discuss these parameters are lacking. PURPOSE: The purpose of this systematic review was to summarize the scientific literature investigating all parameters that can influence both the marginal and internal adaptation of CAD-CAM inlay/onlay restorations. MATERIAL AND METHODS: An electronic search was conducted by 2 independent reviewers for studies published in English between January 1, 2007 and September 20, 2017 on the PubMed/MEDLINE, Scopus, and Web of Science databases and in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Factors investigated in the selected articles included the type of CAD-CAM system, virtual space parameters, version of the software, type of block, luting procedure, type of restoration, sample size and aging procedure, evaluation method, and number of measurement points per specimen. RESULTS: A total of 162 articles were identified, of which 23 articles met the inclusion criteria. Nine studies investigated adaptation with different restorative materials, 2 evaluated adaptation according to the type of preparation design, 9 compared adaptation before/after thermomechanical loading, and 2 before/after cementation, 1 study investigated marginal adaptation based on whether the optical scan was made intraorally or extraorally, 1 compared adaptation with 5 and 3 axis CAM systems, and 1 assessed adaptation with 4 different intraoral scanners. The risk of bias was high for 7, medium for 15, and low for 1 of the studies reviewed. The high level of heterogeneity across the studies excluded meta-analysis. CONCLUSIONS: Most of the studies reported clinically acceptable values for marginal adaptation. The performance of a CAD-CAM system is influenced by the type of restorative material. A nonretentive cavity preparation exhibited better adaptation than a retentive preparation. Most studies showed that thermomechanical loading affected the quality of marginal adaptation. Cementation increased marginal discrepancies. No statistically significant difference was found for marginal fit of onlays between intraoral and extraoral optical scans using a stone die. The number of milling axes, the type of digital camera, and the region measured were statistically significant in relation to marginal/internal adaptation. Values of adaptation recorded failed to reproduce the preestablished spacer parameters in the software. Clarification is needed concerning adaptation according to the type of preparation design, the type of material, the choice of intrinsic parameters for the CAD process, the type and shape of milling instruments, and the behavior of the material during milling. Adaptation of CAD-CAM inlay/onlays should be evaluated under clinical conditions.


Asunto(s)
Adaptación Marginal Dental , Incrustaciones , Diseño Asistido por Computadora , Coronas , Materiales Dentales , Diseño de Prótesis Dental
2.
Dent Mater ; 34(11): e289-e300, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30301623

RESUMEN

OBJECTIVES: The purpose of this work is a proof of concept to introduce a new quantitative 3D-analysis of dental erosion obtained by focused ion beam (FIB) tomography associated with silver nitrate penetration into porosities in etched enamel. METHODS: One sample selected was sound enamel after removal of the aprismatic surface. The other was studied after applying an additional attack with orthophosphoric acid. Both surfaces were infiltrated with silver nitrate via immersion. After dehydration, samples were observed in a dual column FIB/SEM station. Serial FIB sectioning was conducted with a current of 3nA at 30keV and an increment step of 20nm for the healthy enamel and of 40nm for the etched one. 3D analysis was performed with Fiji software and BoneJ plugin and several parameters were obtained to characterize the tissue: non-mineralized phase content (NMP), connected porosity fraction (CPF) and degree of anisotropy (DA) of the NMP. RESULTS: Healthy enamel showed an NMP content of 0.5vol.%, with a bimodal distribution of non-mineralized regions, inside the prisms and between the prisms. No silver penetration was noticed in the healthy enamel, demonstrating the absence of open porosity. In contrast, silver nitrate penetration after acidic exposure was observed, up to a depth of 12µm, which allowed the calculation of an interconnected porosity volume fraction (CPF) of 3.1vol.%, mostly between the prisms. Values for DA of 0.56 for sound enamel and 0.81 for acid-etched surface were determined, highlighting a higher degree of anisotropy in the latter. SIGNIFICANCE: Quantitative analysis of FIB tomography using NMP, CPF and DA should contribute to a better understanding and follow up of dental erosion, correlation between erosion and attrition or abrasion process, and the ability to develop enamel remineralization procedures.


Asunto(s)
Microscopía Electrónica de Rastreo/métodos , Erosión de los Dientes/diagnóstico por imagen , Grabado Ácido Dental , Humanos , Imagenología Tridimensional , Técnicas In Vitro , Tercer Molar , Ácidos Fosfóricos/química , Porosidad , Prueba de Estudio Conceptual , Nitrato de Plata/química
3.
J Prosthet Dent ; 119(3): 384-389, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28552287

RESUMEN

STATEMENT OF PROBLEM: Recent polymer-based computer-assisted design and computer-assisted manufacturing (CAD-CAM) materials have been commercialized for inlay restorations, a polymer-infiltrated ceramic-network (PICN) and composite resin nanoceramics. Little independent evidence regarding their mechanical properties exists. Internal adaptation is an important factor for the clinical success and longevity of a restoration, and data concerning this parameter for inlays made with these blocks are scarce. PURPOSE: The purpose of this in vitro study was to evaluate and compare the mechanical properties (flexural strength, flexural modulus, Vickers hardness, fracture toughness) and the internal adaptation of these recent polymer-based blocks with a lithium disilicate glass-ceramic block. MATERIAL AND METHODS: The materials tested in this study were a PICN material (Vita Enamic), 2 composite resin nanoceramics (Lava Ultimate; 3M ESPE and Cerasmart; GCDental Products), and a lithium disilicate glass-ceramic (IPS e.max CAD). Mechanical properties were evaluated according to ISO norm DIS 6872:2013. Bar-shaped specimens (18×3×3 mm) were prepared and submitted to a 3-point bend test using a universal testing machine at a cross-head speed of 0.5 mm/min. In addition, identical cavities were prepared in 60 human mandibular extracted molars (n=15) and optically scanned to receive mesioocclusodistal inlays milled with the 4 materials tested in a CEREC Inlab milling machine. The replica technique and a stereomicroscope (×20) were used to measure the internal fit of the inlays at 9 preselected locations. All data were statistically analyzed using 1-way ANOVA and the post hoc Tukey multiple comparison or Games-Howell test (α=.05). RESULTS: The mean flexural strength of the tested blocks ranged from 148.7 ±9.5 MPa (Vita Enamic) to 216.5 ±28.3 MPa (Cerasmart). The mean flexural modulus ranged from 23.3 ±6.4 GPa (Vita Enamic) to 52.8 ±10.5 GPa (IPS e.max CAD). The mean Vickers hardness ranged from 0.66 ±0.02 GPa (Cerasmart) to 5.98 ±0.69 GPa (IPS e.max CAD). The mean fracture toughness ranged from 1.2 ±0.17 MPa.m1/2 (Cerasmart) to 1.8 ±0.29 MPa.m1/2 (IPS e.max CAD). The values for internal discrepancy ranged from 119 ±55 µm to 234 ±51 µm. The mean internal discrepancy was significantly higher for Lava Ultimate (P<.05) than IPS e.max CAD and Cerasmart but not for Vita Enamic. The factor ''material'' was statistically significant in relation to the mechanical properties evaluated in this study (P<.05). The Pearson correlation was negative between the flexural strength results and the internal discrepancy of the materials tested (R2=0.941; P<.05). CONCLUSIONS: The mechanical properties of the CAD-CAM block materials tested were within the acceptable range for fabrication of single restorations according to the ISO standard for ceramics (ISO 6872:2008). IPS e.max CAD and Cerasmart were observed to have superior flexural strength and better internal fit.


Asunto(s)
Cerámica , Resinas Compuestas , Diseño Asistido por Computadora , Porcelana Dental , Estrés Mecánico , Humanos , Ensayo de Materiales , Modelos Estadísticos
4.
Trials ; 17: 404, 2016 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-27527342

RESUMEN

BACKGROUND: Current concepts in conservative dentistry advocate minimally invasive dentistry and pulp vitality preservation. Moreover, complete removal of carious dentin in deep carious lesions often leads to pulp exposure and root canal treatment, despite the absence of irreversible pulp inflammation. For years, partial caries removal has been performed on primary teeth, but little evidence supports its effectiveness for permanent teeth. Furthermore, the recent development of new antibacterial adhesive systems could be interesting in the treatment of such lesions. The objectives of this study are to compare the effectiveness of partial versus complete carious dentin removal in deep lesions (primary objective) and the use of an antibacterial versus a traditional two-step self-etch adhesive system (main secondary objective). METHODS/DESIGN: The DEep CAries Treatment (DECAT) study protocol is a multicenter, randomized, controlled superiority trial comparing partial versus complete caries removal followed by adhesive restoration. The minimum sample size required is 464 patients. Two successive randomizations will be performed (allocation ratio 1:1): the first for the type of excavation (partial versus complete) and the second (if no root canal treatment is required) for the type of adhesive (antibacterial versus traditional). For the two objectives, the outcome is the success of the treatment after 1 year, measured according to a composite outcome of five FDI criteria: material fracture and retention, marginal adaptation, radiographic examination (including apical pathologies), postoperative sensitivity and tooth vitality, and carious lesion recurrence. DISCUSSION: The study will investigate the interest of a conservative approach for the management of deep carious lesions in terms of dentin excavation and bioactive adhesive systems. The results may help practitioners achieve the most efficient restorative procedure to maintain pulp vitality and increase the restoration longevity. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT02286388 . Registered in November 2014.


Asunto(s)
Antibacterianos/uso terapéutico , Recubrimiento Dental Adhesivo/métodos , Caries Dental/terapia , Cementos Dentales/uso terapéutico , Recubrimiento de la Pulpa Dental/métodos , Dentina/efectos de los fármacos , Dentina/cirugía , Materiales de Recubrimiento Pulpar y Pulpectomía/uso terapéutico , Pulpectomía/métodos , Grabado Ácido Dental/efectos adversos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antibacterianos/efectos adversos , Niño , Protocolos Clínicos , Recubrimiento Dental Adhesivo/efectos adversos , Caries Dental/diagnóstico por imagen , Caries Dental/microbiología , Cementos Dentales/efectos adversos , Recubrimiento de la Pulpa Dental/efectos adversos , Dentina/diagnóstico por imagen , Dentina/microbiología , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Materiales de Recubrimiento Pulpar y Pulpectomía/efectos adversos , Pulpectomía/efectos adversos , Radiografía Dental , Tamaño de la Muestra , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
5.
Restor Dent Endod ; 40(4): 262-70, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26587411

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the mechanical and physical properties of a newly developed fiber reinforced dental composite. MATERIALS AND METHODS: Fiber reinforced composite EverX Posterior (EXP, GC EUROPE), and other commercially available bulk fill composites, including Filtek Bulk Fill (FB, 3M ESPE), SonicFill (SF, Kerr Corp.), SureFil (SDR, Dentsply), Venus Bulk Fill (VB, HerausKultzer), Tetric evoceram bulk fill (TECB, Ivoclar Vivadent), and Xtra Base (XB, Voco) were characterized. Composite samples light-cured with a LED device were evaluated in terms of flexural strength, flexural modulus (ISO 4049, n = 6), fracture toughness (n = 6), and Vickers hardness (0, 2, and 4 mm in depth at 24 hr, n = 5). The EXP samples and the fracture surface were observed under a scanning electron microscopy. Data were statistically analyzed using one-way ANOVA and unpaired t-test. RESULTS: EXP, FB, and VB had significantly higher fracture toughness value compared to all the other bulk composite types. SF, EXP, and XB were not statistically different, and had significantly higher flexural strength values compared to other tested composite materials. EXP had the highest flexural modulus, VB had the lowest values. Vickers hardness values revealed SF, EXP, TECB, and XB were not statistically different, and had significantly higher values compared to other tested composite materials. SEM observations show well dispersed fibers working as a reinforcing phase. CONCLUSIONS: The addition of fibers to methacrylate-based matrix results in composites with either comparable or superior mechanical properties compared to the other bulk fill materials tested.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...