Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ann Surg Oncol ; 23(10): 3168-74, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27469121

RESUMEN

OBJECTIVES: This study was a multicenter evaluation of the SAVI SCOUT(®) breast localization and surgical guidance system using micro-impulse radar technology for the removal of nonpalpable breast lesions. The study was designed to validate the results of a recent 50-patient pilot study in a larger multi-institution trial. The primary endpoints were the rates of successful reflector placement, localization, and removal. METHODS: This multicenter, prospective trial enrolled patients scheduled to have excisional biopsy or breast-conserving surgery of a nonpalpable breast lesion. From March to November 2015, 154 patients were consented and evaluated by 20 radiologists and 16 surgeons at 11 participating centers. Patients had SCOUT(®) reflectors placed up to 7 days before surgery, and placement was confirmed by mammography or ultrasonography. Implanted reflectors were detected by the SCOUT(®) handpiece and console. Presence of the reflector in the excised surgical specimen was confirmed radiographically, and specimens were sent for routine pathology. RESULTS: SCOUT(®) reflectors were successfully placed in 153 of 154 patients. In one case, the reflector was placed at a distance from the target that required a wire to be placed. All 154 lesions and reflectors were successfully removed during surgery. For 101 patients with a preoperative diagnosis of cancer, 86 (85.1 %) had clear margins, and 17 (16.8 %) patients required margin reexcision. CONCLUSIONS: SCOUT(®) provides a reliable and effective alternative method for the localization and surgical excision of nonpalpable breast lesions using no wires or radioactive materials, with excellent patient, radiologist, and surgeon acceptance.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Radar , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Mamografía , Márgenes de Escisión , Persona de Mediana Edad , Neoplasia Residual , Palpación , Estudios Prospectivos , Reoperación , Cirugía Asistida por Computador/instrumentación , Ultrasonografía Mamaria
2.
Ann Surg Oncol ; 23(6): 1824-30, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26847680

RESUMEN

BACKGROUND: The current technique for locating nonpalpable breast lesions is wire localization (WL). Radioactive seed localization and intraoperative ultrasound were developed to improve difficulties with WL. The SAVI SCOUT surgical guidance system was developed to improve these methods. The SCOUT system is a non-radioactive, FDA-cleared medical device that uses electromagnetic wave technology to provide real-time guidance during excisional breast procedures. METHODS: Consenting patients underwent localization and excision using an implantable electromagnetic wave reflective device (reflector) and a detector handpiece with a console. Using image guidance, the reflector was placed up to 7 days before the surgical procedure. The primary end points of the study were successful reflector placement, localization, and retrieval. The secondary end points were percentage of clear margins, reexcision rates, days of placement before excision, and physician comparison with WL. RESULTS: This study analyzed 50 patients. The reflectors were placed under mammographic guidance (n = 18, 36 %) or ultrasound guidance (n = 32, 64 %). Of the 50 patients, 10 (20 %) underwent excisional biopsy and 40 (80 %) had a lumpectomy. The lesion and reflector were successfully removed in all 50 patients, and no adverse events occurred. Of the 41 patients who had in situ and/or invasive carcinoma identified, 38 (93 %) had clear margins and 3 (7 %) were recommended for reexcision. CONCLUSIONS: These data suggest that the SCOUT system is safe and effective for guiding the excision of nonpalpable breast lesions and a viable alternative to standard localization options. A larger prospective, multi-institution trial of SCOUT currently is underway to validate these findings.


Asunto(s)
Neoplasias de la Mama/patología , Carcinoma Intraductal no Infiltrante/patología , Radiación Electromagnética , Siembra Neoplásica , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Carcinoma Intraductal no Infiltrante/diagnóstico por imagen , Carcinoma Intraductal no Infiltrante/cirugía , Femenino , Estudios de Seguimiento , Humanos , Mamografía , Mastectomía Segmentaria , Persona de Mediana Edad , Invasividad Neoplásica , Proyectos Piloto , Pronóstico , Ultrasonografía Mamaria , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...