Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Knee ; 22(3): 186-91, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25805085

RESUMEN

BACKGROUND: Enhanced wear resistance of ceramics in general and improved mechanical characteristics of composite ceramics in terms of strength and resistance meet the demands for application in TKA. The aim of this prospective international multi-centre study was to evaluate the 5-year clinical and radiological outcomes of an unconstrained TKA with a composite ceramic femoral component. METHODS: A total of 107 patients (109 knees) underwent TKA with the MULTIGEN-PLUS Ceramic Knee at seven centres in three European countries. Clinical and radiological assessments were performed preoperatively and postoperatively at 3, 12, 24 and 60 months, using HSS, WOMAC, SF-36 and standardised radiographs. RESULTS: Mean HSS and WOMAC increased significantly from 55.1±11.5 (21-83) and 48.1±16.6 (3-90) preoperatively to 85.6±9.6 (49-98) and 73.3±20.4 (17-100) at 60 months. Mean SF-36 showed significant improvements in patients' quality of life (49.1±17.6 (12-96) preoperatively versus 67.7±23.1 (12-100) at 60 months). Non-progressive radiolucent lines (<1 mm) were observed around the femoral component in four cases. Neither implant migration nor loosening were registered. Kaplan-Meier survivorship was 96.0% at 60 months (92.1-100%, CI 95%). CONCLUSIONS: Five-year implant survival rate of the ceramic knee is comparable to other metallic and ceramic unconstrained TKA systems. Although the assessment of long-term implant survivorship is still pending, the ceramic implants represent a promising solution for patients with allergies against metallic components and furthermore for the general osteoarthritis population due to enhanced wear resistance.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cerámica , Fémur/cirugía , Prótesis de la Rodilla , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Calidad de Vida , Anciano , Femenino , Fémur/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Factores de Tiempo , Resultado del Tratamiento
2.
Open Orthop J ; 6: 172-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22582104

RESUMEN

BACKGROUND: Total knee arthroplasty can be considered as a reliable surgical procedure with a good long-term clinical result. However, implant failure due to particle induced aseptic loosening as well as the aspect of hypersensitivity to metal ions still remains an emerging issue. METHODS: The purpose of this prospective international multi-centre study was to evaluate the clinical and radiological outcomes and the reliability of the unconstrained Multigen Plus Total Knee System with a new BIOLOX® delta ceramic femoral component. Cemented total knee arthroplasty was performed on 108 patients (110 knees) at seven hospitals in three countries. Clinical and radiological evaluations were performed preoperatively, and after 3, 12 and 24 months postoperatively using the HSS-, WOMAC-, SF-36-score and standardised X-rays. RESULTS: The mean preoperative HSS-Score amounted to 55.5 ± 11.5 points and improved significantly in all postoperative evaluations (85.7 ± 11.7 points at 24 months). Furthermore, improvements in WOMAC- and SF-36-score were evaluated as significant at all points of evaluation. Radiolucent lines around the femoral ceramic component at 24 months were found in four cases. Progression of radiolucent lines was not seen and no implant loosening was observed. During the 24 month follow-up eight patients underwent subsequent surgery due to reasons unrelated to the implant material. CONCLUSIONS: The observed clinical and radiological results are encouraging for a long-term survival of the ceramic femoral component. Therefore, ceramic implants could be a promising solution not only for patients with allergies against metallic implant materials, but also for the osteoarthritic knee joint. Long-term follow-up is necessary to draw conclusions regarding the superiority of the ceramic knee implants concerning in vivo wear and long-term survivorship.

3.
J Pediatr Orthop B ; 13(6): 412-6, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15599236

RESUMEN

PURPOSE: Our aim was to measure antebrachial volar compartment pressure in displaced supracondylar elbow fractures in children. METHODS: We conducted a prospective, observational study of 42 fractures. The mean age was 5.2 years. There was type II displacement in nine cases (21.4%) and type III in 33 (78.6%). A wick catheter (1.5 mm in diameter) was placed perioperatively and compartmental pressure was monitored on a intra-compartmental pressure monitor system (STIC monitor) with a +/- 1 mmHg margin of error. Compartmental, systolic and diastolic pressures were measured every day for the first three postoperative days and then for a 2-week follow-up period. Descriptive statistics, t-test and correlation with a P < 0.05 significance were studied. RESULTS: Mean compartmental pressure before reduction was 8.3 mmHg and 6.7, 4, 2.4, 1.7 and 1 mmHg during the first 3 days and at 1 and 2 weeks post-reduction, respectively. Pressure decreased 40% (P = 0.0005) from the first to the second day and 75% (P = 0.0005) from the first day to the first week. There was no correlation between compartmental pressure and systolic and diastolic pressure. The compartmental pressure decreased significantly by the third postoperative day (P = 0.02). CONCLUSION: Compartmental pressure decreased 60% the first 3 days. In displaced supracondylar fractures with clinical risk factors, it is advisable to monitor compartmental pressure during the first 24-48 h.


Asunto(s)
Síndromes Compartimentales/etiología , Síndromes Compartimentales/prevención & control , Fracturas del Húmero/complicaciones , Monitoreo Fisiológico/instrumentación , Presión Sanguínea/fisiología , Preescolar , Femenino , Humanos , Fracturas del Húmero/cirugía , Masculino , Periodo Posoperatorio , Presión , Estudios Prospectivos , Esfigmomanometros , Transductores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA